Your browser doesn't support javascript.
loading
A novel lung-avoidance planning strategy based on 4DCT ventilation imaging and CT density characteristics for stage III non-small-cell lung cancer patients.
Feng, AiHui; Shao, Yan; Wang, Hao; Chen, Hua; Gu, HengLe; Duan, YanHua; Gan, WuTian; Xu, ZhiYong.
Afiliação
  • Feng A; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China.
  • Shao Y; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China.
  • Wang H; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China.
  • Chen H; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China.
  • Gu H; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China.
  • Duan Y; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China.
  • Gan W; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China.
  • Xu Z; Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, NO.241 West Huaihai Road, Xuhui District, 20030, Shanghai, China. xzyong12vip@sina.com.
Strahlenther Onkol ; 197(12): 1084-1092, 2021 Dec.
Article em En | MEDLINE | ID: mdl-34351454
BACKGROUND: Functional planning based merely on 4DCT ventilation imaging has limitations. In this study, we proposed a radiotherapy planning strategy based on 4DCT ventilation imaging and CT density characteristics. MATERIALS AND METHODS: For 20 stage III non-small-cell lung cancer (NSCLC) patients, clinical plans and lung-avoidance plans were generated. Through deformable image registration (DIR) and quantitative image analysis, a 4DCT ventilation map was calculated. High-, medium-, and low-ventilation regions of the lung were defined based on the ventilation value. In addition, the total lung was also divided into high-, medium-, and low-density areas according to the HU threshold. The lung-avoidance plan aimed to reduce the dose to functional and high-density lungs while meeting standard target and critical structure constraints. Standard and dose-function metrics were compared between the clinical and lung-avoidance plans. RESULTS: Lung avoidance plans led to significant reductions in high-function and high-density lung doses, without significantly increasing other organ at risk (OAR) doses, but at the expense of a significantly degraded homogeneity index (HI) and conformity index (CI; p < 0.05) of the planning target volume (PTV) and a slight increase in monitor units (MU) as well as in the number of segments (p > 0.05). Compared with the clinical plan, the mean lung dose (MLD) in the high-function and high-density areas was reduced by 0.59 Gy and 0.57 Gy, respectively. CONCLUSION: A lung-avoidance plan based on 4DCT ventilation imaging and CT density characteristics is feasible and implementable, with potential clinical benefits. Clinical trials will be crucial to show the clinical relevance of this lung-avoidance planning strategy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: Strahlenther Onkol Assunto da revista: NEOPLASIAS / RADIOTERAPIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: Strahlenther Onkol Assunto da revista: NEOPLASIAS / RADIOTERAPIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China