Doppler ultrasound to assess the pharmacodynamic effects of splanchnic vasoactive compounds.
Marynissen, Heleen; Lodeweyckx, Thomas; Bielen, Didier; de Hoon, Jan.
Afiliação
  • Marynissen H; Center for Clinical Pharmacology, University Hospitals Leuven, Leuven, Belgium.
  • Lodeweyckx T; Center for Clinical Pharmacology, University Hospitals Leuven, Leuven, Belgium.
  • Bielen D; Department of Radiology, University Hospitals Leuven, Leuven, Belgium.
  • de Hoon J; Center for Clinical Pharmacology, University Hospitals Leuven, Leuven, Belgium.
Br J Clin Pharmacol ; 88(4): 1785-1794, 2022 02.
Article em En | MEDLINE | ID: mdl-34558102
AIMS: In search of noninvasive biomarkers to assess the pharmacodynamic effects of portal pressure-lowering drugs, the reproducibility of flow measurements in the superior mesenteric artery was evaluated using Doppler ultrasound. METHODS: A reproducibility study was conducted in 15 healthy male volunteers (18-50 y). Eight ultrasound measurements were performed for each subject: 2 observers each conducted 2 measurements during 2 separate visits. The following flow parameters were captured: peak systolic velocity (PSV), end diastolic velocity (EDV), pulsatility index (PI), volume flow (VF) and vessel diameter. Reproducibility was assessed by the intraclass correlation coefficient. RESULTS: Results are presented as intraclass correlation coefficient [95% confidence interval]. The flow parameters PSV, EDV, PI and VF correlated excellently within observer during visit 1 (0.888 [0.748-0.953], 0.910 [0.793-0.962], 0.844 [0.656-0.933] and 0.916 [0.857-0.951], respectively) and visit 2 (0.925 [0.829-0.968], 0.942 [0.863-0.976], 0.883 [0.719-0.954] and 0.915 [0.855-0.951], respectively). Measurements conducted during 2 separate visits by 1 observer correlated well to excellently for PSV, EDV, PI and VF (0.756 [0.552-0.875], 0.836 [0.694-0.916], 0.807 [0.631-0.904] and 0.839 [0.783-0.882], respectively). Measurements conducted by 2 distinct observers correlated well to excellently for PSV, EDV and VF during visit 1 (0.813 [0.584-0.922], 0.884 [0.597-0.945] and 0.786 [0.575-0.899], respectively) and visit 2 (0.779 [0.498-0.912], 0.861 [0.672-0.945], 0.810 [0.553-0.926], respectively). Vessel diameter measurements were poorly reproducible. CONCLUSION: Doppler ultrasound is a reproducible method for flow measurements in the superior mesenteric artery in a standardized group of healthy volunteers. Therefore, it is a promising technique to assess pharmacodynamic effects of splanchnic vasoactive compounds in early clinical drug development.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrassonografia Doppler Tipo de estudo: Diagnostic_studies Limite: Humans / Male Idioma: En Revista: Br J Clin Pharmacol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrassonografia Doppler Tipo de estudo: Diagnostic_studies Limite: Humans / Male Idioma: En Revista: Br J Clin Pharmacol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Bélgica