Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: A systematic review.
Mühlemann, Sven; Hjerppe, Jenni; Hämmerle, Christoph H F; Thoma, Daniel S.
Afiliação
  • Mühlemann S; Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
  • Hjerppe J; Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
  • Hämmerle CHF; Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
  • Thoma DS; Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
Clin Oral Implants Res ; 32 Suppl 21: 289-302, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34642980
ABSTRACT

OBJECTIVE:

To systematically review the dental literature for clinical studies reporting on production time, effectiveness and/or costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses. MATERIALS AND

METHODS:

A systematic electronic search for clinical studies from 1990 until June 2020 was performed using the online databases Medline, Embase and Cochrane. Time required for the computer-aided design (CAD) process, the CAM process, and the delivery of the CAD-CAM prostheses were extracted. In addition, articles reporting on the effectiveness and the costs of both manufacturing technologies were included.

RESULTS:

Nine clinical studies were included reporting on subtractive CAM (s-CAM; 8 studies) and additive CAM (a-CAM; 1 study). Eight studies reported on the s-CAM of prosthetic and auxiliary components for single implant crowns. One study applied a-CAM for the fabrication of an implant bar prototype. Time was provided for the CAD process of implant models (range 4.9-11.8 min), abutments (range 19.7-32.7 min) and crowns (range 11.1-37.6 min). The time for s-CAM of single implant crown components (abutment/crown) ranged between 8.2 and 25 min. Post-processing (e.g. sintering) was a time-consuming process (up to 530 min). At delivery, monolithic/veneered CAD-CAM implant crowns resulted in additional adjustments chairside (51%/93%) or labside (11%/19%).

CONCLUSIONS:

No scientific evidence exists on production time, effectiveness and costs of digital workflows comparing s-CAM and a-CAM. For both technologies, post-processing may substantially contribute to the production time. Considering effectiveness, monolithic CAD-CAM implant crowns may be preferred compared to veneered CAD-CAM crowns.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Planejamento de Prótese Dentária / Desenho Assistido por Computador Tipo de estudo: Health_economic_evaluation / Systematic_reviews Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Planejamento de Prótese Dentária / Desenho Assistido por Computador Tipo de estudo: Health_economic_evaluation / Systematic_reviews Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Suíça