Your browser doesn't support javascript.
loading
Ion-Ion Charge Reduction Addresses Multiple Challenges Common to Denaturing Intact Mass Analysis.
Bailey, Aaron O; Huguet, Romain; Mullen, Christopher; Syka, John E P; Russell, William K.
Afiliação
  • Bailey AO; University of Texas Medical Branch, 301 University Drive, Galveston, Texas 77551, United States.
  • Huguet R; Thermo Fisher Scientific, 355 River Oaks Pkwy, San Jose, California 95134, United States.
  • Mullen C; Thermo Fisher Scientific, 355 River Oaks Pkwy, San Jose, California 95134, United States.
  • Syka JEP; Thermo Fisher Scientific, 355 River Oaks Pkwy, San Jose, California 95134, United States.
  • Russell WK; University of Texas Medical Branch, 301 University Drive, Galveston, Texas 77551, United States.
Anal Chem ; 94(9): 3930-3938, 2022 03 08.
Article em En | MEDLINE | ID: mdl-35189062
Complete LC-MS-based protein primary sequence characterization requires measurement of intact protein profiles under denaturing and/or reducing conditions. To address issues of protein overcharging of unstructured proteins under acidic, denaturing conditions and sample heterogeneity (macro- and micro-scales) which often confound denaturing intact mass analysis of a wide variety of protein samples, we propose the use of broadband isolation of entire charge state distributions of intact proteins followed by ion-ion proton transfer charge reduction, which we have termed "full scan PTCR" (fsPTCR). Using rapid denaturing size exclusion chromatography coupled to fsPTCR-Orbitrap MS and time-resolved deconvolution data analysis, we demonstrate a strategy for method optimization, leading to significant analytical advantages over conventional MS1. Denaturing analysis of the flexible bacterial translation initiation factor 2 (91 kDa) using fsPTCR reduced overcharging and showed an 11-fold gain in S/N compared to conventional MS1. Analysis by fsPTCR-MS of the microheterogeneous glycoprotein fetuin revealed twice as many proteoforms as MS1 (112 vs 56). In a macroheterogeneous mixture of proteins ranging from 14 to 148 kDa, fsPTCR provided more than 10-fold increased sensitivity and quantitative accuracy for diluted bovine serum albumin (66 kDa). Finally, our analysis shows that collisional gas pressure is a key parameter which can be utilized during fsPTCR to retain or remove larger proteins from acquired spectra.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prótons / Soroalbumina Bovina Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prótons / Soroalbumina Bovina Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos