Your browser doesn't support javascript.
loading
Enhanced Channel Calibration for the Image Sensor of the TuMag Instrument.
Magdaleno, Eduardo; Rodríguez Valido, Manuel; Hernández, David; Balaguer, María; Ruiz Cobo, Basilio; Orozco Suárez, David; Álvarez García, Daniel; González, Argelio Mauro.
Afiliação
  • Magdaleno E; Department of Industrial Engineering, University of La Laguna, 38200 San Cristóbal de La Laguna, Spain.
  • Rodríguez Valido M; Department of Industrial Engineering, University of La Laguna, 38200 San Cristóbal de La Laguna, Spain.
  • Hernández D; Institute of Astrophysics of Canary Islands, 38205 San Cristóbal de La Laguna, Spain.
  • Balaguer M; Department of Astrophysics, University of La Laguna, 38200 San Cristóbal de La Laguna, Spain.
  • Ruiz Cobo B; Institute of Astrophysics of Andalusia, 18008 Granada, Spain.
  • Orozco Suárez D; Institute of Astrophysics of Canary Islands, 38205 San Cristóbal de La Laguna, Spain.
  • Álvarez García D; Department of Astrophysics, University of La Laguna, 38200 San Cristóbal de La Laguna, Spain.
  • González AM; Institute of Astrophysics of Andalusia, 18008 Granada, Spain.
Sensors (Basel) ; 22(6)2022 Mar 08.
Article em En | MEDLINE | ID: mdl-35336249
ABSTRACT
The Sunrise missions consist of observing the magnetic field of the sun continuously for a few days from the stratosphere. In these missions, a balloon supporting a telescope and associated instrumentation, including a Tunable Magnetograph (TuMag), is lifted into the stratosphere. In the camera of this instrument, the image sensor sends its data to a Field Programmable Gate Array (FPGA) using eight transmission channels. These channels must be previously calibrated for a correct delivery of the image. For this mission, the FPGA has been exchanged for a newer and larger one, so the firmware has been adapted to the new device. In addition, the calibration algorithm has been parallelized as the main innovation of this work, taking advantage of the increase in logic resources of the new FPGA, in order to minimize the calibration time of the channels. The algorithm has been implemented specifically for this instrument without using the Input Serial Deserializer (ISERDES) Intellectual Property (IP), since this IP does not support the deserialization of the data sent by the image sensor to the FPGA.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Campos Magnéticos Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Espanha