Your browser doesn't support javascript.
loading
Determining nonesterified and total docosahexaenoic acid and eicosapenaenoic acid concentrations by LC-MS/MS in the plasma of patients with schizophrenia.
Sun, Yufei; Liu, Wenrong; Qiu, Yifan; Wang, Wenyan; Kang, Yimin; Wang, Fan.
Afiliação
  • Sun Y; School of Pharmacy, Key Laboratory of Molecular Pharmacology & Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System & Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, 264005, China.
  • Liu W; School of Pharmacy, Key Laboratory of Molecular Pharmacology & Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System & Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, 264005, China.
  • Qiu Y; School of Pharmacy, Key Laboratory of Molecular Pharmacology & Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System & Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, 264005, China.
  • Wang W; School of Pharmacy, Key Laboratory of Molecular Pharmacology & Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System & Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, 264005, China.
  • Kang Y; Psychosomatic Medicine Research Division, Inner Mongolia Medical University, Huhhot, 010110, China.
  • Wang F; Beijing Hui-Long-Guan Hospital, Peking University, Beijing, 100096, China.
Bioanalysis ; 14(8): 467-477, 2022 Apr.
Article em En | MEDLINE | ID: mdl-35469438
ABSTRACT

Background:

Nonesterified, total docosahexaenoic acid (DHA) and eicosapenaenoic acid (EPA) plasma levels were evaluated in patients with schizophrenia on different medications compared with healthy individuals using validated LC-MS/MS methods.

Methods:

Samples for nonesterified DHA and EPA assay were extracted in n-hexane-dichloromethane-isopropyl alcohol (210.1, V/V/V) and hydrolyzed at 90°C for 2 h before total DHA and EPA determination. Methods were validated in surrogate matrix and plasma.

Results:

These methods generated similar recovery for plasma (>89%) and surrogate matrix (>87%) and negligible matrix effects. Linearity, lower limit of quantification, accuracy, precision and stability were also validated.

Conclusions:

This study successfully determined DHA and EPA plasma levels in patients with schizophrenia and healthy individuals using validated LC-MS/MS methods. Therefore, nonesterified DHA and total EPA levels could be used as schizophrenia biomarkers.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Esquizofrenia / Ácidos Docosa-Hexaenoicos Limite: Humans Idioma: En Revista: Bioanalysis Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Esquizofrenia / Ácidos Docosa-Hexaenoicos Limite: Humans Idioma: En Revista: Bioanalysis Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China