Bilateral inferior petrosal sinus sampling: Procedural data from a German single-center study.
Rofo
; 195(11): 1009-1017, 2023 11.
Article
em En
| MEDLINE
| ID: mdl-37224864
PURPOSE: To assess radiation exposure and diagnostic performance of bilateral inferior petrosal sinus sampling for the distinction of pituitary and ectopic adrenocorticotropin-dependent Cushing's syndrome. MATERIALS AND METHODS: Procedural data of bilateral inferior petrosal sinus procedures were retrospectively evaluated. The analysis included the patients' clinical and demographic data, procedural radiation exposure, and complication rates, sampling results, clinical course of the patients, and calculation of diagnostic performance data. RESULTS: The cases of 46 patients diagnosed with adrenocorticotropin-dependent Cushing's syndrome were evaluated. Bilateral inferior petrosal sinus sampling was successfully performed in 97.8â% of the cases. The overall median procedure-related fluoroscopy time was 7.8âmin. (range 3.2-36.2âmin.), and the median procedural dose area product was 11.9 Gy*cm2 (range 2.1-73.7 Gy*cm2). Radiation doses due to digital subtraction angiography series for visualization of the inferior petrosal sinus were 3.6 Gy*cm2 (range 1.0-18.1 Gy*cm2). Radiation doses due to fluoroscopy had a higher impact on the overall radiation exposure and were significantly influenced by the patients' habitus. The sensitivity, specificity, and positive and negative predictive values were 84â%, 100â%, 100â%, and 72â% before stimulation with corticotropin-releasing hormone, and 97â%, 100â%, 100â%, and 93â% after stimulation. Concordance between magnetic resonance imaging studies and bilateral inferior petrosal sinus sampling results was only found in 35.6â% of the cases. The periprocedural complication rate was 2.2â%, with one patient experiencing vasovagal syncope during catheterization. CONCLUSION: Bilateral inferior petrosal sinus sampling is a safe procedure with high technical success rates und excellent diagnostic performance. The procedure-related radiation exposure shows large variations and depends on the complexity of cannulation as well as the patients' habitus. Fluoroscopy accounted for the largest proportion of radiation exposure. Acquisition of digital subtraction angiography series for the verification of correct catheter placement appears justified. KEY POINTS: · Bilateral inferior petrosal sinus sampling with CRH stimulation provides high diagnostic performance in the distinction of pituitary and ectopic Cushing's syndrome.. · The associated radiation exposure is not negligible and is significantly influenced by the use of fluoroscopy and the patients' habitus.. · Digital subtraction angiography contributes less to the overall radiation dose and appears justified for the verification of correct catheter placement.. CITATION FORMAT: · Augustin A, Detomas M, Hartung V etâal. Bilateral inferior petrosal sinus sampling: Procedural data from a German single-center study. Fortschr Röntgenstr 2023; 195: 1009â-â1017.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Síndrome de ACTH Ectópico
/
Síndrome de Cushing
Limite:
Humans
Idioma:
En
Revista:
Rofo
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
Alemanha