Your browser doesn't support javascript.
loading
Extensive misalignment of plate-haptic rotationally asymmetric multifocal toric intraocular lens.
Oshika, Tetsuro; Nakano, Shinichiro; Inamura, Mikio; Ikai, Nakako; Kato, Yuji; Izumi, Iori; Shimokawabe, Kazuhito.
Afiliação
  • Oshika T; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba, Ibaraki, 305-8575, Japan. oshika@eye.ac.
  • Nakano S; Division of Ophthalmology, Ryugaski Saiseikai Hospital, Ryugasaki, Ibaraki, Japan.
  • Inamura M; Inamura Eye Clinic, Yokoham, Kanagawa, Japan.
  • Ikai N; Inamura Eye Clinic, Yokoham, Kanagawa, Japan.
  • Kato Y; Sapporo Kato Eye Clinic, Sapporo, Hokkaido, Japan.
  • Izumi I; Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba, Ibaraki, 305-8575, Japan.
  • Shimokawabe K; Shimokawabe Eye Clinic, Saga, Japan.
Jpn J Ophthalmol ; 67(5): 560-564, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37289297
ABSTRACT

PURPOSE:

Plate-haptic rotationally asymmetric multifocal toric intraocular lenses (IOL) (Lentis Comfort Toric) occasionally rotate extensively after surgery. We conducted the current study to investigate the incidence of extensive misalignment of this IOL and its association with clinical parameters. STUDY

DESIGN:

Retrospective case series. SUBJECTS AND

METHODS:

Data were collected from patients who had undergone phacoemulsification and implantation of a plate-haptic multifocal toric IOL.

RESULTS:

Among 332 eyes, extensive misalignment of toric IOLs ≥ 45º occurred in 3.3% (11 eyes). The amount of misalignment in eyes with extensive misalignment was 81.6 ± 22.9º, while in those without extensive misalignment, it was 3.0 ± 2.7º. The eyes with extensive misalignment showed significantly greater axial length (p < 0.001), larger corneal diameter (p = 0.034), and flatter corneas (p = 0.044) than those without extensive misalignment. Repositioning surgery to correct toric IOL misorientation was conducted in 9 eyes between 7 and 28 days after cataract surgery. In 2 eyes, repositioning surgery was carried out twice.

CONCLUSIONS:

In majority of cases plate-haptic multifocal toric IOLs showed satisfactory rotational stability, but extensive misalignment ≥ 45º occurred in 3.3% of cases.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Astigmatismo / Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Jpn J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Astigmatismo / Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Jpn J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão