Your browser doesn't support javascript.
loading
Contact allergy to corticosteroids: Is the European baseline series sufficient?
Svendsen, Sebastian Vigand; Bindslev-Jensen, Carsten; Mortz, Charlotte G.
Afiliação
  • Svendsen SV; Department of Dermatology and Allergy Centre, Odense University Hospital, University of Southern Denmark, Odense C, Denmark.
  • Bindslev-Jensen C; Department of Dermatology and Allergy Centre, Odense University Hospital, University of Southern Denmark, Odense C, Denmark.
  • Mortz CG; Department of Dermatology and Allergy Centre, Odense University Hospital, University of Southern Denmark, Odense C, Denmark.
Contact Dermatitis ; 89(4): 277-283, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37321366
ABSTRACT

BACKGROUND:

Patients are consecutively screened for contact allergy to corticosteroids with budesonide and tixocortol-21-pivalate in the European baseline series. Centres using TRUE Test also include hydrocortisone-17-butyrate. A supplementary corticosteroid patch test series is used in case of suspicion of corticosteroid contact allergy or when a marker of corticosteroid contact allergy is positive.

OBJECTIVE:

The aims were to evaluate (1) the efficacy of corticosteroids in the TRUE Test and (2) co-sensitization patterns.

METHODS:

This retrospective study analysed patients patch tested with TRUE Test corticosteroids plus supplementary corticosteroid series in the period 2006-2020 at the Department of Dermatology and Allergy Centre, Odense University Hospital.

RESULTS:

Of 1852 patients tested, 119 were sensitised to TRUE Test corticosteroids and supplementary testing found additional reactions to other corticosteroids in 19 of 119 patients. TRUE Test corticosteroids gave more positive and stronger reactions compared to allergens in petrolatum/ethanol. Fourteen percent of sensitised patients were co-sensitised to multiple corticosteroid groups. Baeck group 3 corticosteroids accounted for 9 of 16 patients not identified by TRUE Test.

CONCLUSIONS:

Budesonide, hydrocortisone-17-butyrate, and tixocortol-21-pivalate in combination are sensitive corticosteroid markers. In case of clinical suspicion of corticosteroid contact allergy, patch testing with supplementary corticosteroids is highly recommended.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dermatite Alérgica de Contato Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Contact Dermatitis Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dermatite Alérgica de Contato Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Contact Dermatitis Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Dinamarca