Your browser doesn't support javascript.
loading
A dual-stage partially interpretable neural network for joint suppression of bSSFP banding and flow artifacts in non-phase-cycled cine imaging.
Chen, Zhuo; Hua, Sha; Gao, Juan; Chen, Yanjia; Gong, Yiwen; Shen, Yiwen; Tang, Xin; Emu, Yixin; Jin, Wei; Hu, Chenxi.
Afiliação
  • Chen Z; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, 415 S Med-X Center, 1954 Huashan Road, Shanghai, 200030, China.
  • Hua S; Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Gao J; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, 415 S Med-X Center, 1954 Huashan Road, Shanghai, 200030, China.
  • Chen Y; Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Gong Y; Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Shen Y; Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Tang X; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, 415 S Med-X Center, 1954 Huashan Road, Shanghai, 200030, China.
  • Emu Y; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, 415 S Med-X Center, 1954 Huashan Road, Shanghai, 200030, China.
  • Jin W; Department of Cardiovascular Medicine, Heart Failure Center, Ruijin Hospital Lu Wan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Hu C; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, 415 S Med-X Center, 1954 Huashan Road, Shanghai, 200030, China. chenxi.hu@sjtu.edu.cn.
J Cardiovasc Magn Reson ; 25(1): 68, 2023 Nov 23.
Article em En | MEDLINE | ID: mdl-37993824

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Artefatos Limite: Humans Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Artefatos Limite: Humans Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China