Your browser doesn't support javascript.
loading
Wearables for Monitoring and Postural Feedback in the Work Context: A Scoping Review.
Figueira, Vânia; Silva, Sandra; Costa, Inês; Campos, Bruna; Salgado, João; Pinho, Liliana; Freitas, Marta; Carvalho, Paulo; Marques, João; Pinho, Francisco.
Afiliação
  • Figueira V; Escola Superior de Saúde do Vale do Ave, Cooperativa de Ensino Superior Politécnico e Universitário, Rua José António Vidal, 81, 4760-409 Vila Nova de Famalicão, Portugal.
  • Silva S; H2M-Health and Human Movement Unit, Polytechnic University of Health, Cooperativa de Ensino Superior Politécnico e Universitário, CRL 4760-409 Vila Nova de Famalicão, Portugal.
  • Costa I; Research Centre in Physical Activity, Health and Leisure, Faculty of Sport, University of Porto, Rua Dr. Plácido da Costa, 91, 4200-450 Porto, Portugal.
  • Campos B; Escola Superior de Saúde do Vale do Ave, Cooperativa de Ensino Superior Politécnico e Universitário, Rua José António Vidal, 81, 4760-409 Vila Nova de Famalicão, Portugal.
  • Salgado J; H2M-Health and Human Movement Unit, Polytechnic University of Health, Cooperativa de Ensino Superior Politécnico e Universitário, CRL 4760-409 Vila Nova de Famalicão, Portugal.
  • Pinho L; School of Health Sciences, University of Aveiro, 3810-193 Aveiro, Portugal.
  • Freitas M; Department of Medical Sciences, University of Aveiro, 3810-193 Aveiro, Portugal.
  • Carvalho P; Escola Superior de Saúde do Vale do Ave, Cooperativa de Ensino Superior Politécnico e Universitário, Rua José António Vidal, 81, 4760-409 Vila Nova de Famalicão, Portugal.
  • Marques J; Escola Superior de Saúde do Vale do Ave, Cooperativa de Ensino Superior Politécnico e Universitário, Rua José António Vidal, 81, 4760-409 Vila Nova de Famalicão, Portugal.
  • Pinho F; Escola Superior de Saúde do Vale do Ave, Cooperativa de Ensino Superior Politécnico e Universitário, Rua José António Vidal, 81, 4760-409 Vila Nova de Famalicão, Portugal.
Sensors (Basel) ; 24(4)2024 Feb 19.
Article em En | MEDLINE | ID: mdl-38400498
ABSTRACT
Wearables offer a promising solution for simultaneous posture monitoring and/or corrective feedback. The main objective was to identify, synthesise, and characterise the wearables used in the workplace to monitor and postural feedback to workers. The PRISMA-ScR guidelines were followed. Studies were included between 1 January 2000 and 22 March 2023 in Spanish, French, English, and Portuguese without geographical restriction. The databases selected for the research were PubMed®, Web of Science®, Scopus®, and Google Scholar®. Qualitative studies, theses, reviews, and meta-analyses were excluded. Twelve studies were included, involving a total of 304 workers, mostly health professionals (n = 8). The remaining studies covered workers in the industry (n = 2), in the construction (n = 1), and welders (n = 1). For assessment purposes, most studies used one (n = 5) or two sensors (n = 5) characterised as accelerometers (n = 7), sixaxial (n = 2) or nonaxialinertial measurement units (n = 3). The most common source of feedback was the sensor itself (n = 6) or smartphones (n = 4). Haptic feedback was the most prevalent (n = 6), followed by auditory (n = 5) and visual (n = 3). Most studies employed prototype wearables emphasising kinematic variables of human movement. Healthcare professionals were the primary focus of the study along with haptic feedback that proved to be the most common and effective method for correcting posture during work activities.