Your browser doesn't support javascript.
loading
Noninvasive Visualization of the Atrioventricular Conduction System Using Cardiac Computed Tomography.
Khoshknab, Mirmilad; Zghaib, Tarek; Xu, Lingyu; Markman, Timothy; Mavroudis, Constantine; Desjardins, Benoit; Nazarian, Saman.
Afiliação
  • Khoshknab M; Division of Medicine, Section of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, Philadelphia.
  • Zghaib T; Division of Medicine, Section of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, Philadelphia.
  • Xu L; Division of Medicine, Section of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, Philadelphia.
  • Markman T; Division of Medicine, Section of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, Philadelphia.
  • Mavroudis C; Department of Surgery, Division of Cardiac Surgery, Hospital of the University of Pennsylvania, Philadelphia.
  • Desjardins B; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia.
  • Nazarian S; Division of Medicine, Section of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, Philadelphia.
JAMA Cardiol ; 2024 Jul 24.
Article em En | MEDLINE | ID: mdl-39046719
ABSTRACT
Importance Noninvasive localization of the compact atrioventricular node and the proximal specialized conduction system (AVCS) would enhance planning for transcatheter aortic valve and complex or congenital heart disease surgical procedures.

Objective:

To test the hypothesis that preprocedure contrast-enhanced cardiac computed tomography (CECT) can accurately localize the AVCS by identification of the fat that insulates the conductive myocardium. Design, Setting, and

Participants:

This was a prospective cohort study that took place at an academic tertiary care center. Included in the study were patients with CECT acquired less than 1 month before atrial fibrillation ablation and electroanatomic localization of the His electrogram signal on electroanatomic mapping (EAM) between January 2022 and January 2023. Exposures Preprocedure CECT. Main Outcomes and

Measures:

The distance from the His electrogram signal to the fat segmentation encompassing the AVCS on CECT, after registration of the images to EAM.

Results:

Among 20 patients (mean [SD] age, 66 [10] years; 15 male [75%]) in the cohort, the mean (SD) attenuation of the AVCS fat segmentation was 2.9 (21.5) Hounsfield units. The mean (SD) distance from the His electrogram to the closest AVCS fat voxel was 3.3 (1.6) mm. Conclusions and Relevance Results of this cohort study suggest that CECT could accurately localize the fatty tissue that insulates the AVCS from surrounding atrial and ventricular myocardium and may enhance the efficacy and safety of procedures targeting the conduction system and structures in its proximity.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: JAMA Cardiol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: JAMA Cardiol Ano de publicação: 2024 Tipo de documento: Article