Your browser doesn't support javascript.
loading
Modality redundancy for MRI-based glioblastoma segmentation.
De Sutter, Selene; Wuts, Joris; Geens, Wietse; Vanbinst, Anne-Marie; Duerinck, Johnny; Vandemeulebroucke, Jef.
Afiliação
  • De Sutter S; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Brussels, Belgium. selene.de.sutter@vub.be.
  • Wuts J; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Brussels, Belgium.
  • Geens W; Department of Radiology and Medical Imaging, Cliniques Universitaires Saint Luc, Université Catholique de Louvain (UCLouvain), Brussels, Belgium.
  • Vanbinst AM; Department of Neurosurgery, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Brussels, Belgium.
  • Duerinck J; Department of Radiology, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Brussels, Belgium.
  • Vandemeulebroucke J; Department of Neurosurgery, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Brussels, Belgium.
Int J Comput Assist Radiol Surg ; 19(10): 2101-2109, 2024 Oct.
Article em En | MEDLINE | ID: mdl-39093499
ABSTRACT

PURPOSE:

Automated glioblastoma segmentation from magnetic resonance imaging is generally performed on a four-modality input, including T1, contrast T1, T2 and FLAIR. We hypothesize that information redundancy is present within these image combinations, which can possibly reduce a model's performance. Moreover, for clinical applications, the risk of encountering missing data rises as the number of required input modalities increases. Therefore, this study aimed to explore the relevance and influence of the different modalities used for MRI-based glioblastoma segmentation.

METHODS:

After the training of multiple segmentation models based on nnU-Net and SwinUNETR architectures, differing only in their amount and combinations of input modalities, each model was evaluated with regard to segmentation accuracy and epistemic uncertainty.

RESULTS:

Results show that T1CE-based segmentation (for enhanced tumor and tumor core) and T1CE-FLAIR-based segmentation (for whole tumor and overall segmentation) can reach segmentation accuracies comparable to the full-input version. Notably, the highest segmentation accuracy for nnU-Net was found for a three-input configuration of T1CE-FLAIR-T1, suggesting the confounding effect of redundant input modalities. The SwinUNETR architecture appears to suffer less from this, where said three-input and the full-input model yielded statistically equal results.

CONCLUSION:

The T1CE-FLAIR-based model can therefore be considered as a minimal-input alternative to the full-input configuration. Addition of modalities beyond this does not statistically improve and can even deteriorate accuracy, but does lower the segmentation uncertainty.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Imageamento por Ressonância Magnética / Glioblastoma Limite: Humans Idioma: En Revista: Int J Comput Assist Radiol Surg Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Imageamento por Ressonância Magnética / Glioblastoma Limite: Humans Idioma: En Revista: Int J Comput Assist Radiol Surg Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Bélgica