1.
Otol Neurotol ; 45(6): 696-702, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38769078

RESUMO

OBJECTIVE: To investigate the microbial changes of long-term hearing aid use culture independently. STUDY DESIGN: Cross-sectional study. PATIENTS: Fifty long-term hearing aid users and 80 volunteer controls with asymptomatic ears. INTERVENTION: External auditory canal (EAC) sampling with DNA-free swabs. MAIN OUTCOME MEASURES: Microbial communities in the samples were investigated with amplicon sequencing of the 16S rRNA gene. RESULTS: The final analysis contained 48 hearing aid users, 59 controls. Twenty-four samples were excluded because of low sequence count, recent use of antimicrobials and/or corticosteroids, recent cold, or missing health status. The groups showed significant differences in bacterial diversity (beta div., p = 0.011), and hearing aid users showed lower species richness than the control group (alpha div., p < 0.01). The most frequent findings in both groups were Staphylococcus auricularis , Alloiococcus otitis , Cutibacterium acnes , Corynebacterium otitidis , and Staphylococcus unclassified sp. Hearing aid users' samples presented more Corynebacterium tuberculostearicum than the control samples. Common EAC pathogens, such as Staphylococcus aureus or Pseudomonas aeruginosa were rare. CONCLUSION: Long-term hearing aid use lowers bacterial diversity and modulates the EAC microbiome. The changes mostly affect commensals. Lowered diversity may predispose individuals to EAC conditions and needs more research.


Assuntos
Meato Acústico Externo , Auxiliares de Audição , Microbiota , Humanos , Masculino , Meato Acústico Externo/microbiologia , Idoso , Feminino , Pessoa de Meia-Idade , Estudos Transversais , RNA Ribossômico 16S/genética , Idoso de 80 Anos ou mais , Adulto , Bactérias/genética , Bactérias/isolamento & purificação
2.
Int J Bioprint ; 9(4): 727, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37323487

RESUMO

Despite advances in prosthesis materials, operating microscopes and surgical techniques during the last 50 years, long-lasting hearing improvement remains a challenge in ossicular chain reconstruction. Failures in the reconstruction are mainly due to inadequate length or shape of the prosthesis, or defects in the surgical procedure. 3D-printed middle ear prosthesis might offer a solution to individualize treatment and obtain better results. The aim of the study was to study the possibilities and limitations of 3D-printed middle ear prostheses. Design of the 3D-printed prosthesis was inspired by a commercial titanium partial ossicular replacement prosthesis. 3D models of different lengths (1.5-3.0 mm) were created with Solidworks 2019-2021 software. The prostheses were 3D-printed with vat photopolymerization using liquid photopolymer Clear V4. Accuracy and reproducibility of 3D printing were evaluated with micro-CT imaging. The acoustical performance of the prostheses was determined in cadaver temporal bones with laser Doppler vibrometry. In this paper, we present an outline of individualized middle ear prosthesis manufacturing. 3D printing accuracy was excellent when comparing dimensions of the 3D-printed prostheses and their 3D models. Reproducibility of 3D printing was good if the diameter of the prosthesis shaft was 0.6 mm. 3D-printed partial ossicular replacement prostheses were easy to manipulate during surgery even though they were a bit stiffer and less flexible than conventional titanium prostheses. Their acoustical performance was similar to that of a commercial titanium partial ossicular replacement prosthesis. It is possible to 3D print functional individualized middle ear prostheses made of liquid photopolymer with good accuracy and reproducibility. These prostheses are currently suitable for otosurgical training. Further research is needed to explore their usability in a clinical setting. In the future, 3D printing of individualized middle ear prostheses may provide better audiological outcomes for patients.

4.
Hear Res ; 434: 108790, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37196460

RESUMO

The electrode-generated intracochlear electrical field (EF) spreads widely along the scala tympani surrounded by poorly-conducting tissue and it can be measured with monopolar transimpedance matrix (TIMmp). Bipolar TIM (TIMbp) allows estimations of local potential differences. With TIMmp, the correct alignment of the electrode array can be assessed, and TIMbp may be useful in more subtle evaluations of the electrode array's intracochlear location. In this temporal bone study, we investigated the effect of the cross-sectional scala area (SA) and the electrode-medial-wall distance (EMWD) on both TIMmp and TIMbp using three types of electrode arrays. Also, multiple linear regressions based on the TIMmp and TIMbp measurements were used to estimate the SA and EMWD. Six cadaver temporal bones were consecutively implanted with a lateral-wall electrode array (Slim Straight) and with two different precurved perimodiolar electrode arrays (Contour Advance and Slim Modiolar) for variation in EMWD. The bones were imaged with cone-beam computed tomography with simultaneous TIMmp and TIMbp measurements. The results from imaging and EF measurements were compared. SA increased from apical to basal direction (r = 0.96, p < 0.001). Intracochlear EF peak negatively correlated with SA (r = -0.55, p < 0.001) irrespective of the EMWD. The rate of the EF decay did not correlate with SA but it was faster in the proximity of the medial wall than in more lateral positions (r = 0.35, p < 0.001). For a linear comparison between the EF decaying proportionally to squared distance and anatomic dimensions, a square root of inverse TIMbp was applied and found to be affected by both SA and EMWD (r = 0.44 and r = 0.49, p < 0.001 for both). A regression model confirmed that together TIMmp and TIMbp can be used to estimate both SA and EMWD (R2 = 0.47 and R2 = 0.44, respectively, p < 0.001 for both). In TIMmp, EF peaks grow from basal to apical direction and EF decay is steeper in the proximity of the medial wall than in more lateral positions. Local potentials measured via TIMbp correlate with both SA and EMWD. Altogether, TIMmp and TIMbp can be used to assess the intracochlear and intrascalar position of the electrode array, and they may reduce the need for intra- and postoperative imaging in the future.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Transversais , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Rampa do Tímpano/cirurgia , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Eletrodos Implantados
5.
J Clin Med ; 12(8)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37109179

RESUMO

Survivors of childhood bacterial meningitis (BM) often develop hearing impairment (HI). In low- and middle-income countries (LMICs), BM continues to be a significant cause of hearing disability. We assessed hearing among BM survivors using auditory steady-state responses (ASSR), providing frequency-specific estimated audiograms, and examined whether ASSR would provide a greater understanding of BM-induced HI. Survivors from two prospective BM trials (ISRCTN62824827; NCT01540838) from Luanda Children's Hospital were examined in a follow-up visit with a median duration of 26 months after BM. The hearing of 50 BM survivors and 19 control children was evaluated using ASSR and auditory brainstem response (ABR) after interview and neurological and otorhinolaryngological examinations. The median age of survivors was 80 (IQR 86) months. We diagnosed HI (better ear hearing ≥ 26 dB) in 9/50 (18%) children. Five of the fifty survivors (10%) and 14/100 ears (14%) had profound HI (>80 dB). Severe-to-profound HI affected all frequencies steadily, affecting only the ears of BM survivors (18/100 vs. 0/38, p = 0.003). When looking only at the severely or profoundly affected ears, young age, low Glascow coma score, pneumococcal aetiology, and ataxia were associated with a worse hearing outcome.

6.
BMC Med Imaging ; 23(1): 51, 2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-37038130

RESUMO

BACKGROUND: Multi slice computed tomography (MSCT) is the most common used method in middle ear imaging. However, MSCT lacks the ability to distinguish the ossicular chain microstructures in detail resulting in poorer diagnostic outcomes. Novel cone beam computed tomography (CBCT) devices' image resolution is, on the other hand, better than MSCT resolution. The aim of this study was to optimize imaging parameters of a novel full body CBCT device to obtain optimal contrast to noise ratio (CNR) with low effective dose, and to optimize its clinical usability. METHODS: Imaging of five anonymous excised human cadaver temporal bones, the acquisition of the effective doses and the CNR measurements were performed for images acquired on using Planmed XFI® full body CBCT device (Planmed Oy, Helsinki, Finland) with a voxel size of 75 µm. All images acquired from the specimens using 10 different imaging protocols varying from their tube current exposure time product (mAs) and tube voltage (kVp) were analyzed for eight anatomical landmarks and evaluated by three evaluators. RESULTS: With the exception of protocol with 90 kVp 100 mAs, all other protocols used are competent to image the finest structures. With a moderate effective dose (86.5 µSv), protocol with 90 kV 450 mAs was chosen the best protocol used in this study. A significant correlation between CNR and clinical image quality of the protocols was observed in linear regression model. Using the optimized imaging parameters, we were able to distinguish even the most delicate middle ear structures in 2D images and produce accurate 3D reconstructions. CONCLUSIONS: In this ex vivo experiment, the new Planmed XFI® full body CBCT device produced excellent 2D resolution and easily created 3D reconstructions in middle ear imaging with moderate effective doses. This device would be suitable for middle ear diagnostics and for e.g., preoperative planning. Furthermore, the results of this study can be used to optimize the effective dose by selecting appropriate exposure parameters depending on the diagnostic task.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada por Raios X/métodos , Orelha Média/diagnóstico por imagem
7.
Artigo em Inglês | MEDLINE | ID: mdl-36834060

RESUMO

Conscripts are exposed to various sources of impulse noise despite hearing protection recommendations. The aim of this study was to investigate the frequency of acute acoustic trauma (AAT) among conscripts after exposure to assault rifle noise in the Finnish Defence Forces (FDF). This nationwide population-based cohort comprised all conscripts (>220,000) in the FDF during the years 1997-2003 and 2008-2010. We included those who claimed to have AAT symptoms from assault rifle noise during the study periods. During the investigated 10 years, 1617 conscripts (annual variation, 75-276) experienced a new hearing loss due to AAT. Altogether, 1456 (90%) of all AAT-induced hearing losses were caused by rifle-caliber weapons and 1304 (90%) of them when firing a blank cartridge. There was no clear diminishing trend in the annual numbers of AATs. In 1277 (88%) incidents, no hearing protector was used. Tinnitus was the most prominent symptom. Hearing losses after AAT were typically mild, but serious deficits also occurred. In conclusion, we found that 0.7-1.5% of the conscripts experienced an AAT during their service in the FDF. Most incidents occurred when firing a blank cartridge with a rifle-caliber weapon and with no hearing protector in use.


Assuntos
Surdez , Perda Auditiva Provocada por Ruído , Perda Auditiva Súbita , Militares , Humanos , Perda Auditiva Provocada por Ruído/prevenção & controle , Finlândia , Dispositivos de Proteção das Orelhas , Ruído , Surdez/complicações , Perda Auditiva Súbita/complicações
8.
Radiat Prot Dosimetry ; 199(5): 462-470, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-36789742

RESUMO

With computed tomography (CT), the delicate structures of the inner ear may be hard to visualise, which a cochlear implant (CI) electrode array can further complicate. The usefulness of a novel cone-beam CT device in CI recipient's inner ear imaging was evaluated and the exposure parameters were optimised to attain adequate clinical image quality at the lowest effective dose (ED). Six temporal bones were implanted with a Cochlear Slim Straight electrode array and imaged with six different imaging protocols. Contrast-to-noise ratio was calculated for each imaging protocol, and three observers evaluated independently the image quality of each imaging protocol and temporal bone. The overall image quality of the inner ear structures did not differ between the imaging protocols and the most relevant inner ear structures of CI recipient's inner ear can be visualised with a low ED. To visualise the most delicate structures in the inner ear, imaging protocols with higher radiation exposure may be required.


Assuntos
Implante Coclear , Implantes Cocleares , Implante Coclear/métodos , Cóclea/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada por Raios X/métodos
9.
Int J Audiol ; 62(9): 877-885, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35994622

RESUMO

OBJECTIVE: To study patient-reported hearing aid (HA) rehabilitation outcomes, social-communicative functioning, and expectations/experiences during eight months of HA use. DESIGN: Three self-reporting instruments, the International Outcome Inventory for Hearing Aids (IOI-HA), the Quantified Denver Scale of Communicative Function (QDS), and questionnaires tapping pre-rehabilitation expectations (HA-EXP-Q1) and post-rehabilitation experiences (HA-EXP-Q2) were administered. STUDY SAMPLE: 144 patients ages 23-66 with gradually acquired, adult-onset, mild-to-moderate sensorineural hearing loss affecting both ears who acquired their first HAs. RESULTS: According to self-reports, HA rehabilitation outcomes were good, and everyday social-communicative functioning improved after one month and after eight months of HA use. When the effects from demographic and audiological variables were analysed, younger age and positive expectations of HAs were associated with better outcomes and social-communicative functioning. The form or hearing loss severity, and the type or number of HAs did not affect outcomes. CONCLUSION: Working-age HA users reported better HA outcomes than older adults in previous studies. Coping in work life may be a strong motivator for active HA use. Considering that younger age and positive expectations resulted in better outcomes, early rehabilitation that supports positive and realistic expectations of HA performance is essential.


Assuntos
Auxiliares de Audição , Perda Auditiva , Humanos , Idoso , Resultado do Tratamento , Autorrelato , Inquéritos e Questionários
10.
Otol Neurotol ; 43(8): 924-930, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35900917

RESUMO

OBJECTIVE: To assess whether aerosol generation occurs during otologic surgery, to define which instruments are aerosol generating, and to identify factors that enhance safety in protection against airborne pathogens, such as severe acute respiratory syndrome coronavirus 2. STUDY DESIGN: An observational prospective study on aerosol measurements during otologic operations recorded between August and December 2020. SETTING: Aerosol generation was measured with an Optical Particle Sizer as part of otologic operations with anesthesia. Particles with a size range of 0.3 to 10 µm were quantified. Aerosol generation was measured during otologic operations to analyze aerosols during drilling in transcanal and transmastoid operations and when using the following instruments: bipolar electrocautery, laser, suction, and cold instruments. Coughing is known to produce significant concentration of aerosols and is commonly used as a reference for high-risk aerosol generation. Thus, the operating room background concentration and coughing were chosen as reference values. PATIENTS: Thirteen otologic operations were included. The average drilling time per surgery was 27.00 minutes (range, 2.00-71.80 min). INTERVENTION: Different rotation speeds during drilling and other instruments were used. MAIN OUTCOME MEASURES: Aerosol concentrations during operations were recorded and compared with background and cough aerosol concentrations. RESULTS: Total aerosol concentrations during drilling were significantly higher than background ( p < 0.0001, d = 2.02) or coughing ( p < 0.0001, d = 0.50). A higher drilling rotation speed was associated with higher particle concentration ( p = 0.037, η2 = 0.01). Aerosol generation during bipolar electrocautery, drilling, and laser was significantly higher than with cold instruments or suction ( p < 0.0001, η2 = 0.04). CONCLUSION: High aerosol generation is observed during otologic surgery when drill, laser, or bipolar electrocautery is used. Aerosol generation can be reduced by using cold instruments instead of electric and keeping the suction on during aerosol-generating procedures. If drilling is required, lower rotation speeds are recommended. These measures may help reduce the spread of airborne pathogens during otologic surgery.


Assuntos
COVID-19 , Tosse , Humanos , Estudos Prospectivos , Aerossóis e Gotículas Respiratórios , SARS-CoV-2
11.
Acta Paediatr ; 111(8): 1585-1593, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35500132

RESUMO

AIM: Bacterial meningitis (BM) is a common cause of hearing loss in childhood. Our aim was to investigate bacterial aetiology, hearing impairment and outcome in childhood BM with vs. without otitis media (OM) in Angola. METHODS: Hearing was tested by auditory brainstem response in 391 (76%) children with confirmed BM. The bacteria identified from the ear discharge were compared to those from cerebrospinal fluid (CSF). The hearing findings were compared among children with vs. without OM on days 1 and 7 of hospitalization, and at follow-ups of 1, 3 and 6 month(s). RESULTS: No correlation was found in bacteriology between the ear discharge and CSF. On day 7 in hospital, hearing impairment (>40 dB) was common, regardless of whether concomitant OM or not (in 27% vs. 30%, respectively). Any hearing deficit on day 7 was associated with a higher risk of complicated or fatal clinical course (OR 2.76, CI95% 1.43-5.29, p = 0.002). CONCLUSION: No significant difference prevailed in hearing thresholds between children with or without OM in hospital on day 7 or at later follow-ups. Any hearing impairment during hospital stay associated with a higher risk for complicated clinical course or death.


Assuntos
Perda Auditiva , Meningites Bacterianas , Otite Média , Criança , Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/etiologia , Testes Auditivos/efeitos adversos , Humanos , Meningites Bacterianas/complicações , Otite Média/complicações
12.
Ear Hear ; 43(1): 220-233, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34260435

RESUMO

OBJECTIVES: Early hearing aid (HA) fitting and cochlear implants (CIs) aim to reduce the effects of hearing loss (HL) on spoken language development. The goals of this study were (1) to examine spoken language skills of children with bilateral HAs and children with bilateral CIs; (2) to compare their language skills to the age-norms of peers with normal hearing (NH); and (3) to investigate factors associated with spoken language outcomes. DESIGN: Spoken language results of 56 Finnish children with HL were obtained from a nationwide prospective multicenter study. Children with HL comprised two groups: children with mild-to-severe HL who used bilateral HAs (BiHA group, n = 28) and children with profound HL who used bilateral CIs (BiCI group, n = 28). Children's spoken language comprehension, expressive and receptive vocabulary, and phonological skills were compared with normative values of children with NH at the age of three years. Odds ratio (OR) was calculated to compare proportions of children below age-norms in BiHA and BiCI groups. Factors associated with spoken language outcomes were modeled with analysis of covariance. RESULTS: At the age of 3 years, 50%-96% of children with HL performed 1 SD or more below the mean of the normative sample of age-peers with NH in spoken language skills, depending on the language domain. Receptive vocabulary and phonological skills were the most vulnerable language domains. In receptive vocabulary, 82% of the children in the BiHA group and 50% of the children in the BiCI group scored 1 SD or more below the normative mean. The BiHA group was 4.4 times more likely to have poorer receptive vocabulary than the BiCI group. In phonological skills, 96% of children in the BiHA group and 60% of the children in the BiCI group scored 1 SD or more below the normative mean. The BiHA group was 18.0 times more likely to have poorer phonological skills than the BiCI group. The analysis of covariance models showed that unaided pure-tone average, PTA0.5-4 kHz, had a significant effect on spoken language comprehension in the BiHA group. For the BiCI group, age at HL diagnosis and age at CI activation had a significant effect on expressive vocabulary. High maternal level of education had a significant effect on language comprehension and expressive vocabulary and female gender on phonological skills. CONCLUSIONS: At the age of 3 years, especially receptive vocabulary and phonological skills caused difficulties for children with HL showing also considerable individual variation. Children with bilateral HAs seemed to be more likely to have poorer receptive vocabulary and phonological skills than children with bilateral CIs. A variety of factors was associated with outcomes in both groups. Close monitoring of spoken language skills of children with HL is important for ensuring similar opportunities for all children with HL and timely intervention, when needed.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Auxiliares de Audição , Perda Auditiva , Criança , Pré-Escolar , Implante Coclear/métodos , Surdez/cirurgia , Feminino , Humanos , Desenvolvimento da Linguagem , Masculino , Estudos Prospectivos , Vocabulário
13.
Life Sci Alliance ; 5(2)2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34815294

RESUMO

Failure in the structural maintenance of the hair cell stereocilia bundle and ribbon synapse causes hearing loss. Here, we have studied how ER stress elicits hair cell pathology, using mouse models with inactivation of Manf (mesencephalic astrocyte-derived neurotrophic factor), encoding an ER-homeostasis-promoting protein. From hearing onset, Manf deficiency caused disarray of the outer hair cell stereocilia bundle and reduced cochlear sound amplification capability throughout the tonotopic axis. In high-frequency outer hair cells, the pathology ended in molecular changes in the stereocilia taper region and in strong stereocilia fusion. In high-frequency inner hair cells, Manf deficiency degraded ribbon synapses. The altered phenotype strongly depended on the mouse genetic background. Altogether, the failure in the ER homeostasis maintenance induced early-onset stereociliopathy and synaptopathy and accelerated the effect of genetic causes driving age-related hearing loss. Correspondingly, MANF mutation in a human patient induced severe sensorineural hearing loss from a young age onward. Thus, we present MANF as a novel protein and ER stress as a mechanism that regulate auditory hair cell maintenance in both mice and humans.


Assuntos
Cóclea/metabolismo , Células Ciliadas Auditivas Internas/metabolismo , Células Ciliadas Auditivas Externas/metabolismo , Fatores de Crescimento Neural/genética , Estereocílios/metabolismo , Sinapses/metabolismo , Suscetibilidade a Doenças , Homeostase , Fatores de Crescimento Neural/metabolismo
14.
J Otol ; 16(3): 138-143, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34220982

RESUMO

The objective was to evaluate the pure-tone audiogram-based screening protocols in VS diagnostics. We retrospectively analyzed presenting symptoms, pure tone audiometry and MRI finding from 246 VS patients and 442 controls were collected to test screening protocols (AAO-HNS, AMCLASS-A/B, Charing Cross, Cueva, DOH, Nashville, Oxford, Rule3000, Schlauch, Seattle, Sunderland) for sensitivity and specificity. Results were pooled with data from five other studies, and analysis of sensitivity, specificity and positive likelihood ratio (LR+) for each protocol was performed. Our results show that protocols with significantly higher sensitivity (AMCLASS-A/B, Nashville) show also significantly lowest specificity, and tend to have low association (positive likelihood ratio, LR+) to the VS. The highest LR+ was found for protocols AAO-HNS, Rule3000 and Seattle. In conclusions, knowing their properties, screening protocols are simple decision-making tools in VS diagnostic. To use the advantage of the highest sensitivity, protocols AMCLASS-A + B or Nashville can be of choice. For more reasonable approach, applying the protocols with high LR+ (AAO-HNS, Rule3000, Seattle) may reduce the overall number of MRI scans at expense of only few primarily undiagnosed VS.

15.
J Otol ; 16(3): 150-157, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34220984

RESUMO

PURPOSE: An important outcome measure of patient care is the impact on the patient's health-related quality of life (HRQoL). Current ear-specific HRQoL instruments are designed for one diagnosis and emphasize different subdivisions such as symptoms, hearing problems, psychosocial impact, and the need for care. The optimal length of the recall period has not been studied. For these reasons, a new survey is needed that would cover most chronic ear diseases. METHODS: A preliminary 24-item survey (EOS-24) was created. Untreated adult patients (included n = 186) with one of seven different chronic otologic conditions from all university hospitals in Finland were recruited to respond to EOS-24 and the 15D general HRQoL instrument. The recruiting otologists evaluated the severity of the disease and the disability caused by it. A control group was recruited. Based on the patients' responses in different diagnosis groups, the items were reduced according to pre-defined criteria. The resulting survey was validated using a thorough statistical analysis. RESULTS: The relevance and necessity of the original 24 items were thoroughly investigated, leading to the exclusion of 8 items and the modification of 1. The remaining 16 items were well-balanced between subdivisions and were useful in all seven diagnosis groups, thus constituting the final instrument, EOS-16. The most suitable recall period was three months. CONCLUSIONS: EOS-16 has been created according to the HRQoL survey guidelines with a versatile nationwide patient population. The survey has been validated and can be used for a wide range of chronic ear diseases as a HRQoL instrument.

16.
J Clin Med ; 10(11)2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34071662

RESUMO

Bilateral cochlear implantation is increasing worldwide. In adults, bilateral cochlear implants (BICI) are often performed sequentially with a time delay between the first (CI1) and the second (CI2) implant. The benefits of BICI have been reported for well over a decade. This study aimed at investigating these benefits for a consecutive sample of adult patients. Improvements in speech-in-noise recognition after CI2 were followed up longitudinally for 12 months with the internationally comparable Finnish matrix sentence test. The test scores were statistically significantly better for BICI than for either CI alone in all assessments during the 12-month period. At the end of the follow-up period, the bilateral benefit for co-located speech and noise was 1.4 dB over CI1 and 1.7 dB over CI2, and when the noise was moved from the front to 90 degrees on the side, spatial release from masking amounted to an improvement of 2.5 dB in signal-to-noise ratio. To assess subjective improvements in hearing and in quality of life, two questionnaires were used. Both questionnaires revealed statistically significant improvements due to CI2 and BICI. The association between speech recognition in noise and background factors (duration of hearing loss/deafness, time between implants) or subjective improvements was markedly smaller than what has been previously reported on sequential BICI in adults. Despite the relatively heterogeneous sample, BICI improved hearing and quality of life.

17.
Prog Brain Res ; 262: 93-113, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33931196

RESUMO

Characterizations of the tinnitus sound percept are always based on a subjective description by the person affected. Since the experimenter cannot have access to the tinnitus percept, it is not possible to verify whether individuals use the adjectives describing the sound in the expected way, i.e., whether a label given to the tinnitus percept corresponds to the label that the experimenter or another individual would give to the same sound percept. However, if it is assumed that tinnitus patients can reliably describe their own tinnitus, then they should also be able to reliably describe tinnitus-like sounds, presented acoustically. In this study, 26 tinnitus patients used a tablet computer to rate 18 pre-defined adjectives on their level of descriptiveness for their own tinnitus percept as well as 17 tinnitus-like sounds presented via headphones. The main interest of the current study was to calculate intraclass correlation (ICC) and Krippendorff's alpha coefficients for the rating profiles of the acoustically-presented sounds, in order to quantify how well the individuals agreed on the ratings of known sounds, i.e., whether the adjectives would receive similar ratings from all participants for a specific tinnitus-like sound. The results show that the level of agreement was low for all adjectives and sounds, meaning that the different individuals did not use the adjectives in a consistent manner. The conclusion is that subjective tinnitus descriptions should be interpreted with great caution, and that the inherent variability involved in the characterization of sounds by naïve listeners can contribute to the observed heterogeneity in tinnitus symptoms and treatment outcomes.


Assuntos
Zumbido , Humanos , Semântica , Som , Zumbido/complicações , Resultado do Tratamento
18.
Hear Res ; 405: 108235, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33901994

RESUMO

A limiting factor of cochlear implant technology is the spread of electrode-generated intracochlear electrical field (EF) leading to spread of neural excitation (SOE). In this study, we investigated the relation of the spread of the intracochlear EF, assessed via transimpedance matrix (TIM), and SOE. A total of 43 consecutive patients (ages 0.7-82 years; 31.0 ± 25.7 years, mean ± SD) implanted with a Cochlear Nucleus CI522 or CI622 cochlear implant with Slim Straight electrode array (altogether 51 ears) were included in the study. Cochlear nerve was visualized for all patients in preoperative imaging and there were no cochlear anomalies in the study sample. The stimulated electrodes were in the basal, middle, and apical parts of the electrode array (electrode numbers 6, 11, and 19, respectively). The stimulation level was 210 CL on average for the TIM measurement and always 230 CL for the SOE measurement. Approximately 90% of the individual TIM and SOE profiles correlated with each other (p < .05; r = 0.61-0.99). Also, the widths of the TIM and SOE peaks, computed at 50% of the maximum height, exhibited a weak correlation (r = 0.39, p = .007). The 50% widths of TIM and SOE were the same only in the apical part of the electrode array; in the basal part SOE was wider than TIM, and in the middle part TIM was wider than SOE (p < .01 and p = .048, respectively). Within each measurement, TIM 50% widths were different between all three parts of the electrode array, while for SOE, only the basal electrode differed from the middle electrode. Finally, the size of the cochlea and the 50% widths of TIM and SOE had the strongest correlation in the middle part of the electrode array (r = -0.63, and -0.37, respectively). Our results suggest that there is a correlation between the spread of intracochlear EF and neural SOE at least in the apical part of the electrode array used in this study, and that larger cochleae are associated with more focused TIM and SOE.


Assuntos
Implante Coclear , Implantes Cocleares , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Cóclea/cirurgia , Nervo Coclear , Eletrodos Implantados , Humanos , Lactente , Pessoa de Meia-Idade , Adulto Jovem
19.
Otol Neurotol ; 42(5): e609-e614, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347052

RESUMO

OBJECTIVE: To investigate the microbiota of the healthy external auditory canal (EAC) culture-independently and to evaluate the usefulness of the swabbing method in collecting EAC microbiota samples. STUDY DESIGN: Cohort study. PATIENTS: Fifty healthy asymptomatic working-age volunteers. INTERVENTION: Samples were harvested with DNA-free swabs from the volunteers' EACs. MAIN OUTCOME MEASURES: Amplicon sequencing of the 16S rRNA gene was used to characterize the microbial communities in the samples. RESULTS: The swabbing method is feasible for EAC microbiota sample collection. The analyzed 41 samples came from 27 female and 14 male subjects; 4 samples were excluded due to recent antimicrobial treatment and 5 because of low sequence count or suspected contaminant microbes. The four most frequent amplicon sequence variants in the microbiota data were Staphylococcus auricularis, Propionibacterium acnes, Alloiococcus otitis, and Turicella otitidis. Typically, the dominant amplicon sequence variant in a sample was one of the most frequent bacteria, but there were also subjects where the dominant species was not among the most frequent ones. The genus Alloiococcus was least common in females who reported cleaning their ears. Subjects with a high relative abundance of Alloiococcus typically had a low abundance of Staphylococcus, which may be a sign of the two being competing members of the microbial community. CONCLUSIONS: The most common bacteria in the microbiome of the healthy EAC were Staphylococcus auricularis, Propionibacterium acnes, Alloiococcus otitis, and Turicella otitidis. The EAC microbiota seems more diverse and individualized than previously thought. Also, ear cleaning habits seem to alter the EAC microbiome.


Assuntos
Microbiota , Otite Média com Derrame , Carnobacteriaceae , Estudos de Coortes , Corynebacterium , Meato Acústico Externo , Orelha Média , Feminino , Humanos , Masculino , RNA Ribossômico 16S/genética , Staphylococcus
20.
Int J Audiol ; 60(3): 210-219, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32964762

RESUMO

OBJECTIVE: Speech-in-noise tests are widely used in hearing diagnostics but typically without reverberation, although reverberation is an inextricable part of everyday listening conditions. To support the development of more real-life-like test paradigms, the objective of this study was to explore how spatially reproduced reverberation affects speech recognition thresholds in normal-hearing and hearing-impaired listeners. DESIGN: Thresholds were measured with a Finnish speech-in-noise test without reverberation and with two test conditions with reverberation times of ∼0.9 and 1.8 s. Reverberant conditions were produced with a multichannel auralisation technique not used before in this context. STUDY SAMPLE: Thirty-four normal-hearing and 14 hearing-impaired listeners participated in this study. Five people were tested with and without hearing aids. RESULTS: No significant differences between test conditions were found for the normal-hearing listeners. Results for the hearing-impaired listeners indicated better performance for the 0.9 s reverberation time compared to the reference and the 1.8 s conditions. Benefit from hearing aid use varied between individuals; for one person, an advantage was observed only with reverberation. CONCLUSIONS: Auralisations may offer information on speech recognition performance that is not obtained with a test without reverberation. However, more complex stimuli and/or higher signal-to-noise ratios should be used in the future.


Assuntos
Auxiliares de Audição , Percepção da Fala , Audição , Humanos , Ruído/efeitos adversos , Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA