Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta Pharm ; 72(2): 259-274, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36651507

RESUMO

The novelty of this work is the simultaneous analysis of sulbactam (SUL), ampicillin (AMP), and paracetamol (PARA) in human urine samples, using the environmentally benign RP-HPLC method. A C18 column was used in chromatographic separation using potassium dihydrogen phosphate (10 mmol L-1, pH 5)/ethanol (90 %, V/V) as the mobile phase; flow rate was 1.00 mL min-1. UV detection at 220 nm was used for quantification. The proposed method showed good linearity in the concentration ranges of 2.20-250.00 µg mL-1 for SUL, 2.50-250.00 µg mL-1 for PARA, and 14.50-250.00 µg mL-1 for AMP. Direct injection of urine samples with no prior extraction was performed. This method was found successful in moving towards greener studies of drugs' urinary excretion, by decreasing hazardous solvent consumption and waste. Moreover, the method was applied to investigate the urinary excretion of the drugs and possible interaction between ampicillin and paracetamol.


Assuntos
Acetaminofen , Sulbactam , Humanos , Sulbactam/análise , Ampicilina/análise , Cromatografia Líquida de Alta Pressão/métodos
2.
J Sep Sci ; 43(8): 1398-1405, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31991050

RESUMO

In this study, a sensitive high-performance liquid chromatography method was developed and validated for the simultaneous determination of seven angiotensin II receptor blockers, namely, hydrochlorothiazide, chlorthalidone, eprosartan mesylate, valsartan, losartan potassium, irbesartan, and candesartan cilexetil. Different chromatographic parameters were tested and fully optimized. Best chromatographic separation was accomplished on a reversed-phase octadecylsilyl column (250 × 4.6 mm id; 5 µm) under gradient elution using methanol/sodium phosphate monobasic buffer (0.01 M, pH 6.5) as mobile phase. The detection of target analytes was obtained at 254 nm. The pH of the buffer has been selected according to Marvin® sketch software. The proposed method was validated according to ICH guidelines and showed good precision (relative standard deviation < 1), good linearity (square of correlation coefficient ≥ 0.999), and high accuracy (between 98 and 102%) with detection limit and quantitation limit (40 and 160 ng/mL, respectively) for all the detected analytes.


Assuntos
Antagonistas de Receptores de Angiotensina/análise , Acrilatos/análise , Benzimidazóis/análise , Compostos de Bifenilo/análise , Clortalidona/análise , Cromatografia Líquida de Alta Pressão , Hidroclorotiazida/análise , Imidazóis/análise , Irbesartana/análise , Losartan/análise , Estrutura Molecular , Software , Comprimidos/análise , Tetrazóis/análise , Tiofenos/análise , Valsartana/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA