Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Evid Based Dent Pract ; 24(2): 101987, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38821664

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Clinical outcomes of digital scans versus conventional impressions for implant-supported fixed complete arch prostheses: A systematic review and meta-analysis. I. A., Spin-Neto, R., Sesma, N., & da Silva, E. V. F. The Journal of Prosthetic Dentistry (2023). SOURCE OF FUNDING: Not reported. TYPE OF STUDY/DESIGN: Systematic review with network meta-analysis of data.


Assuntos
Perda do Osso Alveolar , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Perda do Osso Alveolar/diagnóstico por imagem , Desenho Assistido por Computador , Revisões Sistemáticas como Assunto , Metanálise como Assunto
2.
Clin Exp Dent Res ; 10(1): e858, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38345362

RESUMO

OBJECTIVE: The purpose of this study is to investigate the type of ridge (degree of angulation of the lingual concavity) and the buccolingual dimensions in the area of the first and second molars in both genders of different ages and how this will affect implant placement in the posterior mandible. MATERIALS AND METHODS: This retrospective cross-sectional study comprised cone beam computed tomography images of 150 dental patients (75 males and 71 aged ≥30). The following were measured/reported: type (morphology) of the ridge (convex [C], parallel [P], or undercut [U]), buccolingual width at the base and the crest of the ridge, and ridge height. The concavity angle, depth, and length of the U-shaped ridge were measured too. RESULTS: The prevalence of type U ridge ranged from 32.7% in the first molar region to 62.7% in the second molar region. Almost all measurements and ridge type distributions were comparable amongst the age groups (p > .05). Very few significant differences were found when comparing #36 versus #37 and #46 versus #47 teeth, with no differences in the distribution of the ridge types (p > .05). Quite the inverse, all measurements were statistically different when comparing #36 versus #37 and #46 versus #47 teeth, and type U ridge was more frequent in second molar compared to the first molar regions, respectively (p < .05). Many measurements were statistically higher in females; the inverse was true for a few measurements (p < .05). Type U ridge in #36 and #37 was found more frequently among males (p < .001). In contrast, the ridge types in #37 and #47 were not statistically different gender-wise. CONCLUSIONS: The U type of ridge was more prevalent in the investigated population, encountered more frequently in the second molars generally and in the first molars of males than females. Most posterior mandibular measurements are similar age- and side-wise but seem different gender- and tooth-wise.


Assuntos
Implantes Dentários , Humanos , Masculino , Feminino , Estudos Retrospectivos , Estudos Transversais , Implantação Dentária Endóssea/métodos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia
3.
Biomolecules ; 13(10)2023 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-37892210

RESUMO

BACKGROUND: The emergence of dental implants has revolutionized the management of tooth loss. However, the placement of clinical implants exposes them to complex oral environment and numerous microscopic entities, such as bacteria. Cold atmospheric plasma (CAP) is often used to treat the surfaces of dental implants, which alters morphological features and effectively reduces bacterial load. PURPOSE: This systematic review aims to assess the existing literature on the bactericidal properties of CAP when used on various kinds of dental implant surfaces. REVIEW METHOD: An in-depth examination of MEDLINE/PubMed and EMBASE was performed to identify relevant studies, with the most recent search conducted in May 2023. Studies were selected based on their exploration of CAP's effects on dental implants compared to control groups, focusing on CAP's bactericidal efficacy. However, studies that lacked a control group or that failed to measure bactericidal effects were excluded. RESULTS: After applying the selection criteria, 15 studies were ultimately included in the systematic review. The collected data suggest that CAP can effectively reduce bacterial loads on dental implant surfaces, including pathogens like Streptococcus mitis and Staphylococcus aureus. Furthermore, CAP appears to combat biofilms and plaques that are key contributors to periimplantitis. CONCLUSION: CAP emerges as a promising treatment option, exhibiting significant bactericidal activity on dental implant surfaces. CAP can decrease the rates of bacterial biofilm and plaque formation, leading to improved outcomes for dental implant patients.


Assuntos
Implantes Dentários , Gases em Plasma , Humanos , Gases em Plasma/farmacologia , Bactérias , Biofilmes , Carga Bacteriana , Antibacterianos
4.
Polymers (Basel) ; 15(15)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37571151

RESUMO

An ideal denture base must have good physical and mechanical properties, biocompatibility, and esthetic properties. Various polymeric materials have been used to construct denture bases. Polymethyl methacrylate (PMMA) is the most used biomaterial for dentures fabrication due to its favorable properties, which include ease of processing and pigmenting, sufficient mechanical properties, economy, and low toxicity. This article aimed to comprehensively review the current knowledge about denture base materials (DBMs) types, properties, modifications, applications, and construction methods. We searched for articles about denture base materials in PubMed, Scopus, and Embase. Journals covering topics including dental materials, prosthodontics, and restorative dentistry were also combed through. Denture base material variations, types, qualities, applications, and fabrication research published in English were considered. Although PMMA has several benefits and gained popularity as a denture base material, it has certain limitations and cannot be classified as an ideal biomaterial for fabricating dental prostheses. Accordingly, several studies have been performed to enhance the physical and mechanical properties of PMMA by chemical modifications and mechanical reinforcement using fibers, nanofillers, and hybrid materials. This review aimed to update the current knowledge about DBMs' types, properties, applications, and recent developments. There is a need for specific research to improve their biological properties due to patient and dental staff adverse reactions to possibly harmful substances produced during their manufacturing and use.

5.
J Evid Based Dent Pract ; 23(1): 101837, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36914305

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Artificial intelligence applications in restorative dentistry: A systematic review. Revilla-León, M., Gómez-Polo, M., Vyas, S., Barmak, A. B., Özcan, M., Att, W., & Krishnamurthy, V. R. J Prosthet Dent 2021 SOURCE OF FUNDING: Not reported. TYPE OF STUDY/DESIGN: Systematic review.


Assuntos
Inteligência Artificial , Odontologia , Humanos
6.
Saudi Dent J ; 33(8): 1004-1011, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34938043

RESUMO

BACKGROUND: The available treatment options fail to provide definitive or curative management for bruxer patients rehabilitated with implant overdentures (OD). The data regarding Botulinum toxin (BTX) injection as a management strategy for bruxism remains unclear. This randomized, single-blinded, control-group, pretest-posttest prospective trial evaluated the occlusal guard and Botox injections (BTX) effectiveness in managing sleep bruxism (SB) in subjects whose one of the edentulous arches had been restored with the implant-supported OD. METHODS: Forty-two patients diagnosed with definite bruxism were selected, all of which had implant-retained ODs opposing natural dentition. The participants were allocated randomly to three equal groups. Participants in group I (control group) were instructed to remove the OD at night; group II was managed with conventional occlusal stents. Those in group III were given BTX injections. New ODs were constructed for all groups, and all ball attachments were replaced with a new nylon cap. A baseline assessment (one month of OD insertion) of patient satisfaction and sleep quality was conducted, and then again at 3, 6, 9, and 12 months of treatment. Subjective sleep quality was evaluated using Pittsburgh Sleep Quality Index (PSQI). Patients' satisfaction was evaluated using Temporomandibular disorders/numeric scales (TMD/NS). Prosthodontic (mechanical) complications were recorded during the follow-up period. RESULTS: Group III showed a statistically significant improvement in patient satisfaction and sleep quality compared to the other two groups at 3, 6, 9, and 12 months follow-up period ( P  = 0 0.001, 0.0001, 0.0013, and 0.0001 respectively). Regarding prosthodontic (mechanical) complications, the highest number of events was revealed in the control group. CONCLUSIONS: BTX and occlusal appliances effectively improve patient satisfaction and sleep quality of Bruxer patients rehabilitated with single arch implant overdentures.

7.
J Evid Based Dent Pract ; 21(1): 101530, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-34051952

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Saliva in the Diagnosis of COVID-19: A Review and New Research Directions. Fernandes LL, Pacheco VB, Borges L et al. Journal of Dental Research. 2020. https://doi.org/10.1177/0022034520960070. SOURCE OF FUNDING: Hospital Israelita Albert Einstein and Universidade Cruzeiro do Sul, São Paulo, Brazil. The authors have no actual or potential conflicts of interest. TYPE OF STUDY/DESIGN: Systematic review.


Assuntos
COVID-19 , Saliva , Brasil , Humanos , Nasofaringe , Faringe , SARS-CoV-2
8.
J Prosthet Dent ; 126(3): 369-376, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32891403

RESUMO

STATEMENT OF PROBLEM: Evidence relating to the choice of materials for single implant-supported crowns is sparse. PURPOSE: The purpose of this systematic review and meta-analysis was to assess articles that compared the clinical performance of ceramic and metal-ceramic (MC) implant-supported single crowns with regard to prosthesis failure, complication rate, and patient satisfaction. MATERIAL AND METHODS: A comprehensive search of databases (PubMed/MEDLINE, Scopus, and Cochrane Library) was performed. The last search was conducted in December 2019. Randomized clinical trials comparing ceramic and MC implant-supported single crowns with at least a 12-month follow-up were included, all of which were published in English. The pooled effects were presented as both a risk difference (RD) and mean difference according to the type of data with 95% confidence intervals (CIs). RESULTS: Seven randomized clinical trials fulfilled the eligibility criteria and were included in the meta-analysis. The pooled data did not show any statistically significant differences concerning prosthesis failure (RD: 0.000, 95% CI: -0.05 to 0.06), marginal bone loss (mean difference [MD]: -0.02, 95% CI: -0.75 to 0.35), mechanical complications (RD: -0.06, 95% CI: -0.18 to 0.07), biological complications (RD: 0.02, 95% CI: -0.07 to 0.11), or patient satisfaction (MD: 4.86, 95% CI: -2.86 to 12.58). CONCLUSIONS: Ceramic and MC crowns had similar outcomes with regard to prosthesis failure, mechanical and biological complication rates, and patient satisfaction. As a result, the selection of single implant crown material depends on the preference of the dentist and patient.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Cerâmica , Coroas , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
9.
J Prosthet Dent ; 126(4): 569-574, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32994033

RESUMO

STATEMENT OF PROBLEM: Data on the oral cancer screening skills and beliefs of prosthodontists practicing in Saudi Arabia are lacking. PURPOSE: The purpose of this survey was to assess the beliefs, experiences, and practices of prosthodontists practicing in Saudi Arabia regarding the early detection of oral cancer and potentially malignant disorders. MATERIAL AND METHODS: A cross-sectional, questionnaire-based survey was conducted on prosthodontists practicing in Saudi Arabia. A 26-item questionnaire was sent to all eligible prosthodontists (N=250). The collected data were analyzed with a statistical software program. RESULTS: The response rate was 57.2% (N=143). The majority of participants (79%) reported that they routinely examined all new patients for mucosal pathologies. However, only 58% reported that they examine their patients at recall visits, and only 61.5% stated that they provide tobacco use or smoking cessation advice. With regard to the respondents' experiences with suspicious mucosal lesions, the majority said that they had detected a suspicious lesion (79.7%) and had referred affected patients (83.2%) during their career. Most prosthodontists (65%) believed that they were able to detect oral cancer on their own, and 40% believed that they could influence their patients to stop smoking. A lack of training, confidence, time, and financial incentives were reported as barriers to oral cancer screening. CONCLUSIONS: Most of the prosthodontists surveyed in this study appeared motivated to perform routine oral mucosal screening. However, more efforts are needed to help improve the attitudes, confidence, and skills of prosthodontists when it comes to identifying and referring suspicious oral mucosal lesions.


Assuntos
Odontólogos , Neoplasias Bucais , Estudos Transversais , Humanos , Neoplasias Bucais/diagnóstico , Arábia Saudita , Fumar , Inquéritos e Questionários
10.
J Evid Based Dent Pract ; 18(2): 171-172, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29747801

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Influences of micro-gap and micromotion of the implant-abutment interface on marginal bone loss around implant neck. Liu Y, Wang J. Arch Oral Biol 2017;83:153-60. SOURCE OF FUNDING: This study was financially supported by grants from the National Natural Science Foundation of China (81570956) and the Bureau of Science and Technology of Wuhan ([2014]160, 2015060101010051) TYPE OF STUDY/DESIGN: Comprehensive literature review.


Assuntos
Implantes Dentários , China , Dente Suporte , Planejamento de Prótese Dentária , Humanos
11.
J Evid Based Dent Pract ; 17(4): 402-404, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29197442

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Survival and Complications of Zygomatic Implants: An Updated Systematic Review. Chrcanovic BR, Albrektsson T, Wennerberg A. J Oral Maxillofac Surg 2016;74(10):1949-64. SOURCE OF FUNDING: Self-funding TYPE OF STUDY/DESIGN: Systematic review and meta-analysis.


Assuntos
Maxila , Zigoma , Atrofia , Prótese Dentária Fixada por Implante , Humanos
12.
J Evid Based Dent Pract ; 16(3): 184-186, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27855836

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: What is the optimal number of implants for removable reconstructions? A systematic review on implant-supported overdentures. Roccuzzo M, Bonino F, Gaudioso L, Zwahlen M, Meijer HJ. Clin Oral Implant Res 2012;23.s6:229-37. TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data.


Assuntos
Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Implantes Dentários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA