Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 533
Filtrar
1.
Cardiorenal Med ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38934137

RESUMO

BACKGROUND: Cardiac implantable electrical devices are able to affect kidney function through hemodynamic improvements. The Cardiac Contractility Modulation (CCM) is a device-based therapy option for patients with symptomatic chronic heart failure (HF) despite optimized medical treatment. The long-term cardiorenal interactions for CCM treated patients are yet to be described. METHODS: CCM recipients (n=187) from the Mannheim Cardiac Contractility Modulation Observational Study (MAINTAINED) were evaluated in the long-term (up to 60 months) for changes in serum creatinine, estimated glomerular filtration rate (eGFR), other surrogate markers of kidney function, and the chronic kidney disease (CKD) stage-distribution. With regard to kidney function at baseline, the patients were furthermore grouped to either advanced CKD (aCKD, CKD-stage ≥3, eGFR≤59mL/min/1.73 m2, n=107) or preserved kidney function and mild CKD (pCKD, CKD stages 1-2, eGFR≥60mL/min/1.73 m2, n=80). The groups were compared for differences regarding kidney function, New York Heart Association classification (NYHA), biventricular systolic function, HF hospitalizations and other parameters in the long-term (60 months). RESULTS: CKD stage distribution remained stable during the entire follow-up (p=0.65). An increase in serum creatinine (1.47±1 vs. 1.6±1mg/dL) with a corresponding decline of eGFR (58.2±23.4 vs. 54.2±24.4mL/min/1.73 m2, both p<.05) were seen after 60 months but not before for the total cohort, which was only significant in pCKD patients in terms of group comparison. Mean survival (54.3±1.3 vs. 55.3±1.2months, p=0.53) was comparable in both groups. Improvements in NYHA (3.11±0.46 vs. 2.94±0.41 to 2.28±0.8 vs. 1.94±0.6) and LVEF (24.8±7.1 vs. 22.9±6.6 to 31.1±11.4 vs. 35.5±11.1%) were likewise similar after 60 months (both p <.05). The aCKD patients suffered from more HF-hospitalizations and ventricular tachycardias during the entire follow-up period (both p<.05). CONCLUSIONS: The kidney function parameters and CKD stage distribution might remain stable in CCM treated HF patients in the long-term, who experience improvements in LVEF and functional status, regardless of their kidney function before. An impaired kidney function might be associated with further cardiovascular comorbidities and more advanced HF before CCM, and could be an additional risk factor of HF complications afterwards.

2.
Circ Cardiovasc Qual Outcomes ; : e010637, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38887950

RESUMO

BACKGROUND: Cardiogenic shock is a morbid complication of heart disease that claims the lives of more than 1 in 3 patients presenting with this syndrome. Supporting a unique collaboration across clinical specialties, federal regulators, payors, and industry, the American Heart Association volunteers and staff have launched a quality improvement registry to better understand the clinical manifestations of shock phenotypes, and to benchmark the management patterns, and outcomes of patients presenting with cardiogenic shock to hospitals across the United States. METHODS: Participating hospitals will enroll consecutive hospitalized patients with cardiogenic shock, regardless of etiology or severity. Data are collected through individual reviews of medical records of sequential adult patients with cardiogenic shock. The electronic case record form was collaboratively designed with a core minimum data structure and aligned with Shock Academic Research Consortium definitions. This registry will allow participating health systems to evaluate patient-level data including diagnostic approaches, therapeutics, use of advanced monitoring and circulatory support, processes of care, complications, and in-hospital survival. Participating sites can leverage these data for onsite monitoring of outcomes and benchmarking versus other institutions. The registry was concomitantly designed to provide a high-quality longitudinal research infrastructure for pragmatic randomized trials as well as translational, clinical, and implementation research. An aggregate deidentified data set will be made available to the research community on the American Heart Association's Precision Medicine Platform. On March 31, 2022, the American Heart Association Cardiogenic Shock Registry received its first clinical records. At the time of this submission, 100 centers are participating. CONCLUSIONS: The American Heart Association Cardiogenic Shock Registry will serve as a resource using consistent data structure and definitions for the medical and research community to accelerate scientific advancement through shared learning and research resulting in improved quality of care and outcomes of shock patients.

3.
Eur J Heart Fail ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38847420

RESUMO

AIM: The RESHAPE-HF2 trial is designed to assess the efficacy and safety of the MitraClip device system for the treatment of clinically important functional mitral regurgitation (FMR) in patients with heart failure (HF). This report describes the baseline characteristics of patients enrolled in the RESHAPE-HF2 trial compared to those enrolled in the COAPT and MITRA-FR trials. METHODS AND RESULTS: The RESHAPE-HF2 study is an investigator-initiated, prospective, randomized, multicentre trial including patients with symptomatic HF, a left ventricular ejection fraction (LVEF) between 20% and 50% with moderate-to-severe or severe FMR, for whom isolated mitral valve surgery was not recommended. Patients were randomized 1:1 to a strategy of delivering or withholding MitraClip. Of 506 patients randomized, the mean age of the patients was 70 ± 10 years, and 99 of them (20%) were women. The median EuroSCORE II was 5.3 (2.8-9.0) and median plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) was 2745 (1407-5385) pg/ml. Most patients were prescribed beta-blockers (96%), diuretics (96%), angiotensin-converting enzyme inhibitors/angiotensin receptor blockers/angiotensin receptor-neprilysin inhibitors (82%) and mineralocorticoid receptor antagonists (82%). The use of sodium-glucose cotransporter 2 inhibitors was rare (7%). Cardiac resynchronization therapy (CRT) devices had been previously implanted in 29% of patients. Mean LVEF, left ventricular end-diastolic volume and effective regurgitant orifice area (EROA) were 31 ± 8%, 211 ± 76 ml and 0.25 ± 0.08 cm2, respectively, whereas 44% of patients had mitral regurgitation severity of grade 4+. Compared to patients enrolled in COAPT and MITRA-FR, those enrolled in RESHAPE-HF2 were less likely to have mitral regurgitation grade 4+ and, on average, HAD lower EROA, and plasma NT-proBNP and higher estimated glomerular filtration rate, but otherwise had similar age, comorbidities, CRT therapy and LVEF. CONCLUSION: Patients enrolled in RESHAPE-HF2 represent a third distinct population where MitraClip was tested in, that is one mainly comprising of patients with moderate-to-severe FMR instead of only severe FMR, as enrolled in the COAPT and MITRA-FR trials. The results of RESHAPE-HF2 will provide crucial insights regarding broader application of the transcatheter edge-to-edge repair procedure in clinical practice.

4.
Eur J Heart Fail ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38899626

RESUMO

AIMS: Haemodynamic monitoring using implantable pressure sensors reduces the risk of heart failure (HF) hospitalizations. Patient self-management (PSM) of haemodynamics in HF has the potential to personalize treatment, increase adherence, and reduce the risk of worsening HF, while lowering clinicians' burden. METHODS AND RESULTS: The VECTOR-HF I and IIa studies are prospective, single-arm, open-label clinical trials assessing safety, usability and performance of left atrial pressure (LAP)-guided HF management using PSM in New York Heart Association class II and III HF patients. Physician-prescribed LAP thresholds trigger patient self-adjustment of diuretics. Primary endpoints include the ability to perform LAP measurements and transmit data to the healthcare provider (HCP) interface and the patient guidance application, and safety outcomes. This is an interim analysis of 13 patients using the PSM approach. Over 12 months, no procedure- or device-related major adverse cardiovascular or neurological events were observed, and there were no failures to obtain measurements from the sensor and transmit the data to the HCP interface and the patient guidance application. Patient adherence was 91.4%. Using PSM, annualized HF hospitalization rate significantly decreased compared to a similar period prior to PSM utilization (0 admissions vs. 0.69 admissions over 11.84 months, p = 0.004). At 6 months, 6-min walk test distance and the Kansas City Cardiomyopathy Questionnaire overall summary score demonstrated significant improvement. CONCLUSIONS: Interim findings suggest that PSM using a LAP monitoring system is feasible and safe. PSM is associated with high patient adherence, potentially improving HF patients' functional status, quality of life, and limiting HF hospitalizations.

5.
Am J Cardiol ; 223: 7-14, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38788821

RESUMO

The frequency and effectiveness of repeat mitral valve interventions (RMVI) after transcatheter edge-to-edge repair (TEER) for secondary mitral regurgitation (MR) are unknown. We aimed to examine the rate of and outcomes after RMVI after TEER in the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) trial. Only 3.9% of COAPT trial patients required a repeat mitral valve intervention during 4-year follow-up which was successful in 90% of cases but was associated with an increased rate of heart failure (HF) hospitalizations (HFH). The COAPT trial randomized HF patients with severe secondary MR to TEER with the MitraClip device plus guideline-directed medical therapy (GDMT) versus GDMT alone. We evaluated the characteristics and outcomes of patients who had an RMVI during 4-year follow-up. A MitraClip implant was attempted in 293 patients randomized to TEER+GDMT, 10 of whom underwent an RMVI procedure (9 repeat TEER and 1 surgical mitral valve replacement) after 4 years of follow-up (cumulative incidence 3.90%, 95% confidence interval [CI] 2.08 to 7.08; median 182 days after the initial procedure). Patients with RMVI had larger mitral annular diameters, fewer clips implanted, and were more likely to have ≥3+MR at discharge compared with those without RMVI. Reasons for RMVI included failed index procedure because of difficult transseptal puncture (n = 2) or tamponade (n = 1); residual or recurrent severe MR after an initially successful procedure (n = 5); partial clip detachment (n = 1); and site-assessed mitral stenosis (n = 1). RMVI was successful in 8/10 (80%) patients. Patients who underwent RMVI had higher 4-year rates of HFH but similar mortality compared with those without RMVI. The annualized incidence rates of all HFH in patients who underwent RMVI were 234 events per 100 person-years (95% CI 139 to 395) pre-RMVI and 46 per 100 person-years (95% CI 25 to 86) post-RMVI as compared with 32 events per 100 patient-years (95% CI 28 to 36) in patients without RMVI. The rate ratio of HFH was reduced after RMVI in patients who underwent RMVI (0.20, 95% CI 0.09 to 0.45). In conclusion, the cumulative incidence of RMVI after 4 years was 3.9% in patients who underwent TEER for severe secondary MR in the COAPT trial. Patients who underwent RMVI were at increased risk of HFH which was reduced after the RMVI procedure. Clinical Trial Registration: Clinical Trial Name: Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) (COAPT) ClinicalTrial.gov Identifier: NCT01626079 URL:https://clinicaltrials.gov/ct2/show/NCT01626079.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Masculino , Feminino , Idoso , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Seguimentos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Reoperação , Insuficiência Cardíaca/terapia
6.
ESC Heart Fail ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38773938

RESUMO

AIMS: Interatrial shunts are under evaluation as a treatment for heart failure (HF); however, their in vivo flow performance has not been quantitatively studied. We aimed to investigate the fluid dynamics properties of the 0.51 cm orifice diameter Ventura shunt and assess its lumen integrity with serial transesophageal echocardiography (TEE). METHODS AND RESULTS: Computational fluid dynamics (CFD) and bench flow tests were used to establish the flow-pressure relationship of the shunt. Open-label patients from the RELIEVE-HF trial underwent TEE at shunt implant and at 6 and 12 month follow-up. Shunt effective diameter (Deff) was derived from the vena contracta, and flow was determined by the continuity equation. CFD and bench studies independently validated that the shunt's discharge coefficient was 0.88 to 0.89. The device was successfully implanted in all 97 enrolled patients; mean age was 70 ± 11 years, 97% were NYHA class III, and 51% had LVEF ≤40%. Patency was confirmed in all instances, except for one stenotic shunt at 6 months. Deff remained unchanged from baseline at 12 months (0.47 ± 0.01 cm, P = 0.376), as did the trans-shunt mean pressure gradient (5.1 ± 3.9 mmHg, P = 0.316) and flow (1137 ± 463 mL/min, P = 0.384). TEE measured flow versus pressure closely correlated (R2 ≥ 0.98) with a fluid dynamics model. At 12 months, the pulmonary/systemic flow Qp/Qs ratio was 1.22 ± 0.12. CONCLUSIONS: When implanted in patients with advanced HF, this small interatrial shunt demonstrated predictable and durable patency and performance.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38795108

RESUMO

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6 and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).

8.
Eur J Heart Fail ; 26(4): 1078-1089, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38561314

RESUMO

AIMS: Heart failure (HF) outcomes remain poor despite optimal guideline-directed medical therapy (GDMT). We assessed safety, effectiveness, and transthoracic echocardiographic (TTE) outcomes during the 12 months after Ventura shunt implantation in the RELIEVE-HF open-label roll-in cohort. METHODS AND RESULTS: Eligibility required symptomatic HF despite optimal GDMT with ≥1 HF hospitalization in the prior year or elevated natriuretic peptides. The safety endpoint was device-related major adverse cardiovascular or neurological events at 30 days, compared to a prespecified performance goal. Effectiveness evaluations included the Kansas City Cardiomyopathy Questionnaire (KCCQ) at baseline, 1, 3, 6, and 12 months and TTE at baseline and 12 months. Overall, 97 patients were enrolled and implanted at 64 sites. Average age was 70 ± 11 years, 97% were in New York Heart Association class III, and half had left ventricular ejection fraction (LVEF) ≤40%. The safety endpoint was achieved (event rate 0%, p < 0.001). KCCQ overall summary score was improved by 12-16 points at all follow-up timepoints (all p < 0.004), with similar outcomes in patients with reduced and preserved LVEF. At 12 months, left ventricular end-systolic and end-diastolic volumes were reduced (p = 0.020 and p = 0.038, respectively), LVEF improved (p = 0.009), right ventricular end-systolic and end-diastolic areas were reduced (p = 0.001 and p = 0.030, respectively), and right ventricular fractional area change (p < 0.001) and tricuspid annular plane systolic excursion (p < 0.001) improved. CONCLUSION: Interatrial shunting with the Ventura device was safe and resulted in favourable clinical effects in patients with HF, regardless of LVEF. Improvements of left and right ventricular structure and function were consistent with reverse myocardial remodelling. These results would support the potential of this shunt device as a treatment for HF.


Assuntos
Ecocardiografia , Insuficiência Cardíaca , Volume Sistólico , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Feminino , Masculino , Idoso , Volume Sistólico/fisiologia , Ecocardiografia/métodos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade
9.
Eur J Heart Fail ; 26(4): 1051-1061, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606555

RESUMO

AIMS: Carotid baroreflex activation therapy (BAT) restores baroreflex sensitivity and modulates the imbalance in cardiac autonomic function in patients with heart failure with reduced ejection fraction (HFrEF). We tested the hypothesis that treatment with BAT significantly reduces cardiovascular mortality and heart failure morbidity and provides long-term safety and sustainable symptomatic improvement. METHODS AND RESULTS: BeAT-HF was a prospective, multicentre, randomized, two-arm, parallel-group, open-label, non-implanted control trial. New York Heart Association (NYHA) class III subjects, ejection fraction ≤35%, previous heart failure hospitalization or N-terminal pro-B-type natriuretic peptide (NT-proBNP) >400 pg/ml, no class I indication for cardiac resynchronization therapy and NT-proBNP <1600 pg/ml were randomized to BAT plus optimal medical management (BAT group) or optimal medical management alone (control). The primary endpoint was cardiovascular mortality and HF morbidity; additional pre-specified endpoints included durability of safety, quality of life (QOL), exercise capacity (6-min hall walk distance [6MHWD]), functional status (NYHA class), hierarchical composite win ratio, freedom from all-cause death, left ventricular assists device (LVAD) implantation, heart transplant. Overall, 323 patients had 332 primary events, median follow-up was 3.6 years/patient. Both primary endpoint (rate ratio 0.94, 95% confidence interval [CI] 0.57-1.57; p = 0.82) and components of the primary endpoints were not significantly different between BAT and control. The system- and procedure-related major adverse neurological and cardiovascular event-free rate remained 97% throughout the trial. Symptom improvement (QOL, 6MHWD, NYHA class, all nominal p < 0.001) in the BAT group was durable in time, sustainable in extent. Win ratio (1.26, 95% CI 1.02-1.58) and freedom from all-cause death, LVAD implantation, heart transplant (hazard ratio 0.66, 95% CI 0.43-1.01) favoured the BAT group but did not reach statistical significance. CONCLUSION: The BeAT-HF primary endpoint was neutral; however, BAT provided safe, effective, and sustainable improvements in HFrEF patient's functional status, 6MHWD and QOL.


Assuntos
Barorreflexo , Insuficiência Cardíaca , Qualidade de Vida , Volume Sistólico , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Masculino , Feminino , Volume Sistólico/fisiologia , Barorreflexo/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Resultado do Tratamento , Peptídeo Natriurético Encefálico/sangue , Terapia por Estimulação Elétrica/métodos , Tolerância ao Exercício/fisiologia , Seguimentos
10.
JACC Heart Fail ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38530702

RESUMO

BACKGROUND: Inadequate inclusion in clinical trial enrollment may contribute to health inequities by evaluating interventions in cohorts that do not fully represent target populations. OBJECTIVES: The aim of this study was to determine if characteristics of patients with heart failure (HF) enrolled in a pivotal trial are associated with who receives an intervention after approval. METHODS: Demographics from 2,017,107 Medicare patients hospitalized for HF were compared with those of the first 10,631 Medicare beneficiaries who received implantable pulmonary artery pressure sensors. Characteristics of the population studied in the pivotal CHAMPION (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients) clinical trial (n = 550) were compared with those of both groups. All demographic data were analyzed nationally and in 4 U.S. regions. RESULTS: The Medicare HF cohort included 80.9% White, 13.3% African American, 1.9% Hispanic, 1.3% Asian, and 51.5% female patients. Medicare patients <65 years of age were more likely to be African American (33%) and male (58%), whereas older patients were mostly White (84%) and female (53%). Forty-one percent of U.S. HF hospitalizations occurred in the South; demographic characteristics varied significantly across all U.S. regions. The CHAMPION trial adequately represented African Americans (23% overall, 35% <65 years of age), Hispanic Americans (2%), and Asian Americans (1%) but underrepresented women (27%). The trial's population characteristics were similar to those of the first patients who received pulmonary artery sensors (82% White, 13% African American, 1% Asian, 1% Hispanic, and 29% female). CONCLUSIONS: Demographics of Centers for Medicare and Medicaid Services beneficiaries hospitalized with HF vary regionally and by age, which should be considered when defining "adequate" representation in clinical studies. Enrollment diversity in clinical trials may affect who receives early application of recently approved innovations.

11.
JACC Heart Fail ; 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38530701

RESUMO

Clinical trials are vital for assessing therapeutic interventions. The associated data monitoring committees (DMCs) safeguard patient interests and enhance trial integrity, thus promoting timely, reliable evaluations of those interventions. We face an urgent need to recruit and train new DMC members. The Heart Failure Collaboratory (HFC), a multidisciplinary public-private consortium of academics, trialists, patients, industry representatives, and government agencies, is working to improve the clinical trial ecosystem. The HFC aims to improve clinical trial efficiency and quality by standardizing concepts, and to help meet the demand for experienced individuals on DMCs by creating a standardized approach to training new members. This paper discusses the HFC's training workshop, and an apprenticeship model for new DMC members. It describes opportunities and challenges DMCs face, along with common myths and best practices learned through previous experiences, with an emphasis on data confidentiality and need for quality independent statistical reporting groups.

12.
Heart Rhythm ; 21(6): 845-854, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38360252

RESUMO

BACKGROUND: Women might benefit more than men from cardiac resynchronization therapy (CRT) and do so at shorter QRS durations. OBJECTIVE: This meta-analysis was performed to determine whether sex-based differences in CRT effects are better accounted for by height, body surface area (BSA), or left ventricular end-diastolic dimension (LVEDD). METHODS: We analyzed patient-level data from CRT trials (MIRACLE, MIRACLE ICD, MIRACLE ICD II, REVERSE, RAFT, COMPANION, and MADIT-CRT) using bayesian hierarchical Weibull regression models. Relationships between QRS duration and CRT effects were examined overall and in sex-stratified cohorts; additional analyses indexed QRS duration by height, BSA, or LVEDD. End points were heart failure hospitalization (HFH) or death and all-cause mortality. RESULTS: Compared with men (n = 5628), women (n = 1439) were shorter (1.62 [interquartile range, 1.57-1.65] m vs 1.75 [1.70-1.80] m; P < .001), with smaller BSAs (1.76 [1.62-1.90] m2 vs 2.02 [1.89-2.16] m2; P < .001). In adjusted sex-stratified analyses, the reduction in HFH or death was greater for women (hazard ratio, 0.54; credible interval, 0.42-0.70) than for men (hazard ratio, 0.77; credible interval, 0.66-0.89; Pinteraction = .009); results were similar for all-cause mortality even after adjustment for height, BSA, and LVEDD. Sex-specific differences were observed only in nonischemic cardiomyopathy. The effect of CRT on HFH or death was observed at a shorter QRS duration for women (126 ms) than for men (145 ms). Indexing QRS duration by height, BSA, or LVEDD attenuated sex-specific QRS duration thresholds for the effects of CRT on HFH or death but not on mortality. CONCLUSION: Although body size partially explains sex-specific QRS duration thresholds for CRT benefit, it is not associated with the magnitude of CRT benefit. Indexing QRS duration for body size might improve selection of patients for CRT, particularly with a "borderline" QRS duration.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Feminino , Fatores Sexuais , Masculino , Tamanho Corporal
13.
J Am Coll Cardiol ; 83(6): 682-694, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38325994

RESUMO

BACKGROUND: Trials evaluating implantable hemodynamic monitors to manage patients with heart failure (HF) have shown reductions in HF hospitalizations but not mortality. Prior meta-analyses assessing mortality have been limited in construct because of an absence of patient-level data, short-term follow-up duration, and evaluation across the combined spectrum of ejection fractions. OBJECTIVES: The purpose of this meta-analysis was to determine whether management with implantable hemodynamic monitors reduces mortality in patients with heart failure and reduced ejection fraction (HFrEF) and to confirm the effect of hemodynamic-monitoring guided management on HF hospitalization reduction reported in previous studies. METHODS: The patient-level pooled meta-analysis used 3 randomized studies (GUIDE-HF [Hemodynamic-Guided Management of Heart Failure], CHAMPION [CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients], and LAPTOP-HF [Left Atrial Pressure Monitoring to Optimize Heart Failure Therapy]) of implantable hemodynamic monitors (2 measuring pulmonary artery pressures and 1 measuring left atrial pressure) to assess the effect on all-cause mortality and HF hospitalizations. RESULTS: A total of 1,350 patients with HFrEF were included. Hemodynamic-monitoring guided management significantly reduced overall mortality with an HR of 0.75 (95% CI: 0.57-0.99); P = 0.043. HF hospitalizations were significantly reduced with an HR of 0.64 (95% CI: 0.55-0.76); P < 0.0001. CONCLUSIONS: Management of patients with HFrEF using an implantable hemodynamic monitor significantly reduces both mortality and HF hospitalizations. The reduction in HF hospitalizations is seen early in the first year of monitoring and mortality benefits occur after the first year.


Assuntos
Insuficiência Cardíaca , Monitorização Hemodinâmica , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Próteses e Implantes , Hemodinâmica , Diuréticos , Hospitalização
14.
Eur J Heart Fail ; 26(2): 502-510, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38247193

RESUMO

Despite remarkable improvements in the management of heart failure (HF), HF remains one of the most rapidly growing cardiovascular condition resulting in a substantial burden on healthcare systems worldwide. In clinical practice, however, a relevant proportion of patients are treated with suboptimal combinations and doses lower than those recommended in the current guidelines. Against this background, it remains important to identify new targets and investigate additional therapeutic options to alleviate symptoms and potentially improve prognosis in HF. Therefore, non-pharmacological interventions targeting autonomic imbalance in HF have been evaluated. This paper aims to review the physiology, available clinical data, and potential therapeutic role of device-based neuromodulation in HF.


Assuntos
Doenças Cardiovasculares , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Prognóstico
15.
J Am Heart Assoc ; 13(3): e033255, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38258663

RESUMO

BACKGROUND: The Breakthrough Devices Program of the US Food and Drug Administration has accelerated the development and evaluation of medical devices for patients with heart failure. One such device is the Optimizer Smart System, which the US Food and Drug Administration approved in 2019. METHODS AND RESULTS: The Optimizer device was evaluated in a pivotal randomized clinical trial (FIX-HF-5C [Confirmatory Randomized Trial Evaluating the Optimizer System]) that leveraged Bayesian borrowing of external data to reduce the sample size and determine therapeutic device benefit versus continued medical therapy. Bayesian borrowing is explained in the context of the FIX-HF-5C trial, including an overview of the statistical methodologies, regulatory considerations, and interpretations of trial results. CONCLUSIONS: The US Food and Drug Administration Breakthrough Devices Program and novel Bayesian statistical methodology accelerated the path to regulatory approval and patient access to a potentially lifesaving device and may serve as a model for future clinical trials.


Assuntos
Insuficiência Cardíaca , Humanos , Teorema de Bayes , Ensaios Clínicos Controlados Aleatórios como Assunto , Insuficiência Cardíaca/terapia
16.
JACC Heart Fail ; 12(1): 1-15, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38069997

RESUMO

Acute decompensated heart failure (ADHF) is one of the most common reasons for hospitalizations or urgent care and is associated with poor outcomes. Therapies shown to improve outcomes are limited, however, and innovation in pharmacologic and device-based therapeutics are therefore actively being sought. Standardizing definitions for ADHF and its trajectory is complex, limiting the generalizability and translation of clinical trials to effect clinical care and policy change. The Heart Failure Collaboratory is a multistakeholder organization comprising clinical investigators, clinicians, patients, government representatives (including U.S. Food and Drug Administration and National Institutes of Health participants), payors, and industry collaborators. The following expert consensus document is the product of the Heart Failure Collaboratory convening with the Academic Research Consortium, including members from academia, the U.S. Food and Drug Administration, and industry, for the purposes of proposing standardized definitions for ADHF and highlighting important endpoint considerations to inform the design and conduct of clinical trials for drugs and devices in this clinical arena.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Hospitalização
17.
Am Heart J ; 267: 81-90, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37984672

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces heart failure hospitalizations (HFH) and mortality for guideline-indicated patients with heart failure (HF). Most patients with HF are aged ≥70 years but such patients are often under-represented in randomized trials. METHODS: Patient-level data were combined from 8 randomized trials published 2002-2013 comparing CRT to no CRT (n = 6,369). The effect of CRT was estimated using an adjusted Bayesian survival model. Using age as a categorical (<70 vs ≥70 years) or continuous variable, the interaction between age and CRT on the composite end point of HFH or all-cause mortality or all-cause mortality alone was assessed. RESULTS: The median age was 67 years with 2436 (38%) being 70+; 1,554 (24%) were women; 2,586 (41%) had nonischemic cardiomyopathy and median QRS duration was 160 ms. Overall, CRT was associated with a delay in time to the composite end point (adjusted hazard ratio [aHR] 0.75, 95% credible interval [CI] 0.66-0.85, P = .002) and all-cause mortality alone (aHR of 0.80, 95% CI 0.69-0.96, P = .017). When age was treated as a categorical variable, there was no interaction between age and the effect of CRT for either end point (P > .1). When age was treated as a continuous variable, older patients appeared to obtain greater benefit with CRT for the composite end point (P for interaction = .027) with a similar but nonsignificant trend for mortality (P for interaction = .35). CONCLUSION: Reductions in HFH and mortality with CRT are as great or greater in appropriately indicated older patients. Age should not be a limiting factor for the provision of CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Feminino , Idoso , Masculino , Teorema de Bayes , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Modelos de Riscos Proporcionais
18.
JACC Heart Fail ; 12(3): 451-460, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38099892

RESUMO

Heart failure (HF) is a complex syndrome traditionally classified by left ventricular ejection fraction (LVEF) cutpoints. Although LVEF is prognostic for risk of events and predictive of response to some HF therapies, LVEF is a continuous variable and cutpoints are arbitrary, often based on historical clinical trial enrichment decisions rather than physiology. Holistic evaluation of the treatment effects for therapies throughout the LVEF range suggests the standard categorization paradigm for HF merits modification. The multidisciplinary Heart Failure Collaboratory reviewed data from large-scale HF clinical trials and found that many HF therapies have demonstrated therapeutic benefit across a large range of LVEF, but specific treatment effects vary across that range. Therefore, HF should practically be classified by association with an LVEF that is reduced or not reduced, while acknowledging uncertainty around the precise LVEF cutpoint, and future research should evaluate new therapies across the continuum of LVEF.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Humanos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Prognóstico , Fatores de Tempo
19.
Circulation ; 148(14): 1113-1126, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37782695

RESUMO

The Shock Academic Research Consortium is a multi-stakeholder group, including representatives from the US Food and Drug Administration and other government agencies, industry, and payers, convened to develop pragmatic consensus definitions useful for the evaluation of clinical trials enrolling patients with cardiogenic shock, including trials evaluating mechanical circulatory support devices. Several in-person and virtual meetings were convened between 2020 and 2022 to discuss the need for developing the standardized definitions required for evaluation of mechanical circulatory support devices in clinical trials for cardiogenic shock patients. The expert panel identified key concepts and topics by performing literature reviews, including previous clinical trials, while recognizing current challenges and the need to advance evidence-based practice and statistical analysis to support future clinical trials. For each category, a lead (primary) author was assigned to perform a literature search and draft a proposed definition, which was presented to the subgroup. These definitions were further modified after feedback from the expert panel meetings until a consensus was reached. This manuscript summarizes the expert panel recommendations focused on outcome definitions, including efficacy and safety.


Assuntos
Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/cirurgia , Projetos de Pesquisa
20.
Eur J Heart Fail ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37671601

RESUMO

AIMS: Patients with heart failure usually have several other medical conditions that might alter the effects of interventions. We investigated whether the burden of comorbidity modified the clinical response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Original patient-level data from eight randomized trials exploring the effects of CRT versus no CRT were pooled (BLOCK-HF, MIRACLE, MIRACLE-ICD, MIRACLE-ICD II, RAFT, COMPANION, MADIT-CRT and REVERSE). A prior history of the following comorbidities was considered: episodic or persistent atrial fibrillation (n = 920), coronary artery disease (n = 3732), diabetes (n = 2171), and hypertension (n = 3353). Patients were classified into three groups based on the number of comorbidities: 0, 1-2, or ≥3. The outcomes of interest were time to all-cause mortality and time to the composite outcome of heart failure hospitalization (HFH) or all-cause mortality. Outcomes were evaluated within each comorbidity group using a Bayesian hierarchical Weibull survival regression model. Of 6324 patients, 970 (15%) had no comorbidities, 4052 (64%) had 1-2 and 1302 (21%) had ≥3 comorbidities. The adjusted hazard ratio (aHR) for CRT versus no CRT for all-cause mortality in the overall cohort was 0.79 (95% credible interval [CI] 0.68-0.93) (p = 0.010); for no comorbidities the aHR was 0.54 (95% CI 0.34-0.86), for 1-2 comorbidities was 0.81 (95% CI 0.67-0.97) and for ≥3 comorbidities was 0.83 (95% CI 0.64-1.07) (no significant interaction between CRT and comorbidity burden: p = 0.13). For the endpoint of HFH or all-cause mortality, the aHR for the overall cohort was 0.74 (95% CI 0.65-0.84) (p = 0.001), for no comorbidities was 0.69 (95% CI 0.50-0.94), for 1-2 comorbidities was 0.77 (95% CI 0.66-0.90) and for ≥3 comorbidities was 0.68 (95% CI 0.55-0.82) (no significant interaction between CRT and comorbidity burden: p = 0.081). CONCLUSION: In a meta-analysis of patient-level data from eight major trials, the totality of evidence suggests that CRT reduces HFH and/or all-cause mortality even when several comorbid diseases are present. CLINICAL TRIAL REGISTRATION: NCT00271154, NCT00251251, NCT00267098, NCT00180271.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA