Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Horm Res ; 59(5): 249-53, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12714789

RESUMO

AIM: To analyze the insulin-like growth factor 1 (IGF-1) serum levels in nonagenarian patients and to investigate the predictive capacity of this measure to assess the functional recovery of this population following hospitalization. METHODS: We performed a prospective study in 60 consecutive nonagenarian patients admitted for medical or surgical diseases. We assessed IGF-1 serum levels and nutritional status. The functional status was assessed using the Barthel index. Thirty-four patients were reinvestigated 3 months after discharge from hospital. RESULTS: The mean levels of IGF-1 were lower in nonagenarians than in younger patients. No relationship was found between IGF-1 levels and nutritional status. The decline in Barthel index values 3 months after discharge from hospital did not correlate with serum levels of IGF-1 on admission. CONCLUSION: IGF-1 serum levels in nonagenarian patients do not predict functional recovery after hospitalization.


Assuntos
Idoso de 80 Anos ou mais/fisiologia , Idoso Fragilizado , Hospitalização , Peptídeos e Proteínas de Sinalização Intercelular/sangue , Recuperação de Função Fisiológica/fisiologia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estado Nutricional/fisiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Valores de Referência , Fatores Sexuais
2.
Ther Drug Monit ; 22(4): 474-80, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10942190

RESUMO

Recently, a semiautomated fluorescence polarization immunoassay (FPIA) for determination of parent cyclosporin (CsA) has been developed for the Abbott AxSYM system. The new CsA assay measures the drug from an extracted whole blood specimen. The authors report here the evaluation of this new assay and the comparison with a previously validated radioimmunoassay (RIA) method (CYCLO-Trac SP). To assess the imprecision, the authors used tri-level controls supplied by both Abbott and Bio-Rad manufacturers. The within-run CV ranged from 4.4% to 7.3% and the between-day CV ranged from 4.4% to 7.6%. Mean recovery of the drug from clinical specimens spiked with kit calibrators was 108.4%. Fluorescence polarization immunoassay AxSYM (y) was correlated to RIA (x) by using 132 trough blood specimens (44 renal, 44 liver, and 44 heart) from transplant recipients and resulted in the following Passing-Bablok linear regression equation: y = 6.7 + 0.97x, r = 0.989, S(x/y) = 12.9. The percentage of overestimation (mean, range) by FPIA AxSYM versus RIA was (3.8%, range -17.7% to 39.1%). The results observed with this new method from follow-up studies in patients during the early course after transplant were not consistently higher than those obtained by RIA. These findings contrast with previously reported results that compared FPIA TDx assay with RIA. The authors conclude that FPIA AxSYM is a precise method for measuring CsA and offers results similar to those obtained by RIA with a marked reduction in assay time.


Assuntos
Ciclosporina/sangue , Imunossupressores/sangue , Imunoensaio de Fluorescência por Polarização , Seguimentos , Humanos , Transplante de Fígado , Radioimunoensaio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA