Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Microbiol ; 41(1): 242-9, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12517855

RESUMO

We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced more positive results (n = 58) than either culture (n = 55) or the Directigen immunoassay (n = 31). The results of the LightCycler PCR and the Directigen method were independently compared to the results of the accepted "gold standard," bacterial culture. The sensitivities, specificities, and positive and negative predictive values for this comparison were as follows: for the Directigen method, 55, 99, 97, and 93%, respectively; for the LightCycler PCR, 93, 98, 88, and 99%, respectively. In no case was a throat swab positive by both the LightCycler PCR and the Directigen method but negative by culture. The medical histories of patients whose throat swabs were negative by culture but positive by either the LightCycler PCR (n = 7) or the Directigen method (n = 1) were reviewed. All of these patients had signs or symptoms compatible with GAS disease, and therefore, all of these discordant positive results (along with positive results by either the Directigen method or the LightCycler PCR that agreed with the culture results) were counted as true positives for statistical analysis. For this analysis, the LightCycler PCR detected more true-positive results than the culture method (58 versus 55 swabs); however, this difference was not statistically significant (P = 0.5465). In contrast, statistically significantly more true-positive results occurred by culture than by the Directigen method (55 versus 31 swabs; P < 0.0001) and by the LightCycler PCR than by the Directigen method (58 versus 31 swabs; P < 0.0001). The LightCycler PCR is a suitable stand-alone method for the detection of GAS from throat swabs. Additionally, this method requires less than half the personnel time and the procedure can be completed in considerably less time ( approximately 1 h) than our standard approach (up to 2 days) for detection of GAS in throat swabs (i.e., testing by the Directigen method with negative results verified by culture).


Assuntos
Faringe/microbiologia , Streptococcus pyogenes/isolamento & purificação , Técnicas de Cultura de Células , Humanos , Imunoensaio , Reação em Cadeia da Polimerase , Avaliação de Processos em Cuidados de Saúde/economia , Estudos Prospectivos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Infecções Estreptocócicas , Fatores de Tempo
2.
Obstet Gynecol ; 67(4): 604-6, 1986 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3960433

RESUMO

To assess the occurrence of premature ovarian failure, the age-specific incidence rates of natural menopause were determined for a cohort of 1858 women born between 1928 and 1932. These women were identified as Rochester, Minnesota residents in 1950 and were followed for date and type of menopause. A total of nine experienced natural menopause before age 40 years, which represents a 1% risk of natural menopause to age 40. The annual incidence rates of natural menopause per 100,000 person-years were ten for ages 15 to 29 and 76 for ages 30 to 39. In the age group 40 to 44, the incidence of natural menopause increased greatly to 881 per 100,000 person-years at risk.


Assuntos
Menopausa Precoce , Menopausa , Fatores Etários , Estradiol/sangue , Feminino , Seguimentos , Gonadotropinas/sangue , Humanos , Pessoa de Meia-Idade , Ovário/fisiologia , Gravidez , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA