Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Nanoscale ; 16(9): 4858-4865, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38314839

RESUMO

Magnonic crystals, periodic arrays of magnetic structures, have emerged as a promising platform for manipulating and controlling spin waves in magnetic materials. Magnetic antidot nanostructures, representing 2-D magnonic crystals, are versatile platforms for controlling and manipulating magnons. In this work, we systematically investigate the effects of inter-hole spacing and lattice (rhombic and honeycomb) arrangements on the dynamic properties of Ni80Fe20 antidot structures. The dynamic responses of antidot lattices of fixed hole diameter (d = 280 nm) and inter-hole spacing (s) between 90 and 345 nm are investigated using broadband ferromagnetic spectroscopy. Multiple resonance modes sensitive to s are observed due to the inhomogeneous internal field distribution induced by the presence of holes. There is a marked variation in mode frequency, mode intensity and the number of modes for rhombic antidot lattice as the inter-hole spacing and applied field direction are varied. Our experimental results are in good agreement with micromagnetic simulations. Our findings may find application in the design of magnonic-based devices.

2.
Niger J Clin Pract ; 26(2): 223-228, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36876612

RESUMO

Background: Abdominal trauma is a major cause of morbidity and mortality in low-and middle-income countries. Typical patients present late and very sick with early recognition key to improving outcome. There is a paucity of trauma data in this environment and trauma scoring systems which have been validated in the developed world are yet to find widespread use here. Aim: This study aimed at evaluating role of injury severity score (ISS) in predicting mortality. Patients and Methods: This is a retrospective observational study of patients with abdominal trauma who presented at the University of Ilorin Teaching Hospital from 2013 to 2019. Records were identified and data were extracted and analyzed using Statistical package for social sciences 23. Results: A total of 87 patients were included in the study. There were 73 males and 14 females. The mean overall ISS in this study was 16.06 ± 7.9. Concerning morbidity, the area under the receiver operating characteristic curve in predicting morbidity was 0.843 (95% confidence interval 0.737-0.928). ISS had a strong sensitivity of 90% and specificity 55% at a cut-off of 14.50. Also, the area under the receiver operating characteristic curve in predicting mortality was 0.746 (95% confidence interval 0.588-0.908) and at a cut-off of 16.50; ISS had a specificity of 80% and sensitivity of 60%. The mean ISS of patients with mortality was 22.60 ± 10.5 while the survivors had a mean ISS of 14.7 ± 6.5 (P <.001). The mean ISS for patients who had morbidity was 22.8 ± 8.1 while those without morbidity had a mean ISS of 13.1 ± 5.7 (P <.05). Conclusion: ISS was a good predictor of morbidity and mortality in abdominal trauma in patients in this study. A prospective study with standardized abdominal imaging would be needed to further validate this scoring tool.


Assuntos
Traumatismos Abdominais , Feminino , Humanos , Masculino , Traumatismos Abdominais/mortalidade , Escala de Gravidade do Ferimento , Estudos Prospectivos , Centros de Atenção Terciária , Nigéria/epidemiologia
3.
West Afr J Med ; 38(9): 885-891, 2021 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-34677043

RESUMO

BACKGROUND: Colonoscopy is an invaluable tool used in the diagnosis of colorectal diseases. It is also useful in the prevention and treatment of some of these diseases. The knowledge of the prevailing colorectal diseases is key to planning for prevention. OBJECTIVES: This study aimed at determining the spectra of indications and findings at colonoscopy in a tertiary health facility. METHODS: This was a hospital-based cross-sectional study of all patients who underwent colonoscopy between March 2013 and February 2020. The patients' biodata, indications and findings at colonoscopy were retrieved from the Endoscopy Register. RESULTS: A total of 385 colonoscopy reports were included in the analysis. The age of the patients ranged from 14 to 95 years with a mean age (standard deviation) of 55.9 (15.4) years. There were 219 (57.0%) males and 166 (43.0%) females. The commonest indication for colonoscopy was haematochezia 150 (38.9%) followed by suspected colorectal malignancy 98 (25.5%), abdominal pain 28 (7.3%), altered bowel habit 21 (5.5%), constipation 20 (5.2%), chronic diarrhoea 19 (4.9%), surveillance/ screening 16 (4.2%), occult bleeding and anal pain 7 (1.8%) each, and others 19 (4.9%). The colonoscopy findings were normal findings 116 (30.1%), haemorrhoids 127 (32.9%), colorectal polyps 70 (18.2%), diverticulosis 46 (11.9%), rectal tumour 43 (11.2%), colonic tumour 32 (8.3%), colitis 23 (5.9%), angiodysplasias 6 (1.6), others 12 (3.1%). The findings were not mutually exclusive. Our diagnostic yield was 69.9%. CONCLUSION: The commonest indication and diagnosis for colonoscopy were haematochezia and haemorrhoids respectively. Our diagnostic yield was 69.9%.


CONTEXTE: La coloscopie est un outil précieux utilisé dans le diagnostic des maladies colorectales. Il est également utile dans la prévention et le traitement de certaines de ces maladies. La connaissance des maladies colorectales prédominantes est essentielle à la planification de la prévention. OBJECTIFS: Cette étude visait à déterminer les spectres d'indications et les résultats à la coloscopie dans un établissement de santé tertiaire. MÉTHODES: Il s'agissait d'une étude transversale en milieu hospitalier portant sur tous les patients ayant subi une coloscopie entre mars 2013 et février 2020. Les données biographiques, les indications et les résultats de la coloscopie des patients ont été extraits du registre d'endoscopie. RÉSULTATS: Un total de 385 rapports de coloscopie ont été inclus dans l'analyse. L'âge des patients variait de 14 à 95 ans avec un âge moyen (écart type) de 55,9 (15,4) ans. Il y avait 219 (57,0%) hommes et 166 (43,0 %) femmes. L'indication la plus courante de la coloscopie était l'hématochézie 150 (38,9%) suivie d'une suspicion de malignité colorectale 98 (25,5%), de douleurs abdominales 28 (7,3%), d'altération des habitudes intestinales 21 (5,5%), de constipation 20 (5,2%), de diarrhée chronique 19 (4,9 %), surveillance/dépistage 16 (4,2 %), saignement occulte et douleur anale 7 (1,8 %) chacun, et autres 19 (4,9 %). Les résultats de la coloscopie étaient normaux 116 (30,1%), hémorroïdes 127 (32,9%), polypes colorectaux 70 (18,2%), diverticulose 46 (11,9%), tumeur rectale 43 (11,2%), tumeur colique 32 (8,3%), colite 23 (5,9 %), angiodysplasies 6 (1,6), autres 12 (3,1%). Les résultats n'étaient pas mutuellement exclusifs. Notre rendement diagnostique était de 69,9 %. CONCLUSION: L'indication et le diagnostic les plus courants de la coloscopie étaient respectivement l'hématochézie et les hémorroïdes. Notre rendement diagnostique était de 69,9 %. Mots clés: Maladies colorectales, coloscopie, indications, spectres, rendement diagnostique.


Assuntos
Colonoscopia , Neoplasias Colorretais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/epidemiologia , Hemorragia Gastrointestinal/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Nigéria/epidemiologia , Centros de Atenção Terciária , Adulto Jovem
4.
Br J Surg ; 2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34165555

RESUMO

BACKGROUND: Surgery is the primary treatment that can offer potential cure for gastric cancer, but is associated with significant risks. Identifying optimal surgical approaches should be based on comparing outcomes from well designed trials. Currently, trials report different outcomes, making synthesis of evidence difficult. To address this, the aim of this study was to develop a core outcome set (COS)-a standardized group of outcomes important to key international stakeholders-that should be reported by future trials in this field. METHODS: Stage 1 of the study involved identifying potentially important outcomes from previous trials and a series of patient interviews. Stage 2 involved patients and healthcare professionals prioritizing outcomes using a multilanguage international Delphi survey that informed an international consensus meeting at which the COS was finalized. RESULTS: Some 498 outcomes were identified from previously reported trials and patient interviews, and rationalized into 56 items presented in the Delphi survey. A total of 952 patients, surgeons, and nurses enrolled in round 1 of the survey, and 662 (70 per cent) completed round 2. Following the consensus meeting, eight outcomes were included in the COS: disease-free survival, disease-specific survival, surgery-related death, recurrence, completeness of tumour removal, overall quality of life, nutritional effects, and 'serious' adverse events. CONCLUSION: A COS for surgical trials in gastric cancer has been developed with international patients and healthcare professionals. This is a minimum set of outcomes that is recommended to be used in all future trials in this field to improve trial design and synthesis of evidence.

5.
J Phys Condens Matter ; 33(41)2021 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-33662946

RESUMO

Magnonics is a budding research field in nanomagnetism and nanoscience that addresses the use of spin waves (magnons) to transmit, store, and process information. The rapid advancements of this field during last one decade in terms of upsurge in research papers, review articles, citations, proposals of devices as well as introduction of new sub-topics prompted us to present the first roadmap on magnonics. This is a collection of 22 sections written by leading experts in this field who review and discuss the current status besides presenting their vision of future perspectives. Today, the principal challenges in applied magnonics are the excitation of sub-100 nm wavelength magnons, their manipulation on the nanoscale and the creation of sub-micrometre devices using low-Gilbert damping magnetic materials and its interconnections to standard electronics. To this end, magnonics offers lower energy consumption, easier integrability and compatibility with CMOS structure, reprogrammability, shorter wavelength, smaller device features, anisotropic properties, negative group velocity, non-reciprocity and efficient tunability by various external stimuli to name a few. Hence, despite being a young research field, magnonics has come a long way since its early inception. This roadmap asserts a milestone for future emerging research directions in magnonics, and hopefully, it will inspire a series of exciting new articles on the same topic in the coming years.

6.
Nanoscale ; 12(40): 20933-20944, 2020 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-33090176

RESUMO

This paper investigates the control of effective magnetic anisotropy in Permalloy linear chain arrays, achieved by tuning the symmetry arrangement of the ellipsoidal nanomagnets and the film thickness. When the ellipsoidal nanomagnets are coupled along their easy axis, stronger effective magnetic anisotropy is achieved compared to when the nanomagnets are coupled along their hard axis. A clear transition from a single domain state to a combination of complex flux closure states such as a vortex or double vortices is observed at different applied field angles when the film thickness is varied in the range from 20 nm to 100 nm. Tunable microwave absorption spectra, obtained by ferromagnetic resonance spectroscopy, established the complex interplay between the shape anisotropy and magnetostatic interactions, which becomes more intriguing at different film thicknesses and applied field angles. The micromagnetic simulations are in good agreement with the experimental results. Our results demonstrate possible ways of manipulating the effective magnetic anisotropy in arrays of nanomagnets for magnonic and microwave applications.

7.
EClinicalMedicine ; 21: 100303, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32280940

RESUMO

BACKGROUND: Daily oral TDF/FTC is protective against HIV infection when used for pre-exposure prophylaxis (PrEP). However, daily adherence to oral PrEP is difficult for many; therefore, finding alternative PrEP strategies remains a priority. HPTN 076 evaluated the long-acting injectable form of rilpivirine (RPV), known as RPV LA for safety, pharmacokinetics and acceptability. METHODS: HPTN 076 (NTC 02165202) was a phase 2, double-blind, 2:1 randomized trial comparing the safety of 1200mg RPV LA (LA) to placebo (P). The study included a 28-day oral run-in phase of daily, self- administered oral RPV (25 mg), with directly observed oral dosing about six times. Of 136 enrolled sexually active, HIV-uninfected, low HIV-risk African (100) and US (36) adult women, injectable product was administered in two gluteal, intramuscular (IM) injections once every eight weeks to 122 participants following the oral run-in phase. A maximum of six injection time points occurred over a 48-week period. Acceptability, safety, tolerability and pharmacokinetic (PK) data were collected throughout the study. This paper includes primary endpoint data collected up to the week 52 post enrollment. FINDINGS: The median age of the enrolled population was 31 years (IQR: 25,38), median weight 75 kg (IQR: 64, 89), median body mass index (BMI) 30 (IQR: 27, 35), 46% married, 94% Black and 60% unemployed. A total of 122 (80 LA, 42 P) women received at least one injection and 98 (64 LA, 34 P) received all six injections. During the injection phase, three women withdrew from the study (2 LA, 1 P) and 16 women discontinued study product (10 LA, 6 P). Fourteen women (11 LA and 3 P) discontinued oral study product and did not enter the injection phase. Study product discontinuations were not significantly different between the two arms throughout. Of the product discontinuations in the injection phase, 8% in LA and 5% in P arm were due to adverse events (AEs), including one randomized to the P arm with prolonged QTc interval on EKG. The proportion of women who experienced Grade 2 or higher AEs during the injection phase as the primary outcome was not significantly different between the two arms [73.8%, 95% CI: (63.2%, 82.1%) for LA and 73.8%, 95% CI: (58.9%, 84.7%), p>0.99]. Transient Grade ≥2 liver abnormalities occurred in 14% of women in the LA arm compared with 12% in P arm. Three LA women (4%) developed Grade 3 injection site reactions compared with none in P arm. In participants who received at least 1 injection, the geometric mean of overall RPV trough concentrations (Ctrough) was 62.2 ng/mL. In participants who received all six injections, the geometric mean of CTrough through the injection phase and after the last injection were 72.8 ng/mL and 100.9 ng/mL, respectively. At week 52 (eight weeks after last injection), the geometric mean of RPV Ctrough was 75.0 ng/mL. At the last injection visit (Week 44), 80 % of women who answered acceptability questions strongly agreed that they would think about using- and 68% that they would definitely use a PrEP injectable in the future. INTERPRETATION: RPV LA IM injections every eight weeks in African and US women were safe and acceptable. Overall, despite more injection site reactions and pain in the participants receiving RPV LA the injections were well tolerated. Data from this study support the further development of injectable PrEP agents.

8.
Sci Rep ; 9(1): 4617, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30874580

RESUMO

We have studied both experimentally and theoretically the reprogrammable spin wave band structure in Permalloy(10 nm)/Cu(5 nm)/Permalloy(30 nm) nanowire arrays of width w = 280 nm and inter-wire separation in the range from 80 to 280 nm. We found that, depending on the inter-wire separation, the anti-parallel configuration, where the magnetizations of the two Permalloy layers point in opposite directions, is stabilized over specific magnetic field ranges thus enabling us to directly compare the band structure with that of the parallel alignment. We show that collective spin waves of the Bloch type propagate through the arrays with different magnonic bandwidths as a consequence of the interplay between the intra- and inter-nanowire dynamic dipolar interactions. A detailed understanding, e.g. whether they have a stationary or propagating character, is achieved by considering the phase relation (in-phase or out-of-phase) between the dynamic magnetizations in the two ferromagnetic layers and their average value. This work opens the path to magnetic field-controlled reconfigurable layered magnonic crystals that can be used for future nanoscale magnon spintronic devices.

9.
Sci Rep ; 8(1): 13695, 2018 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-30209330

RESUMO

This article presents a study whose purpose is to elucidate the damage effects in thin films on their magnetic response. Co40Fe40B20 and Ni80Fe20 films of different nanometric thicknesses were stretched by more than 10% and in situ probed by atomic force microscopy measurements to determine their irreversible mechanical behavior (multi-cracking, buckling). Once these phenomena have been well identified, magnetic behavior of these stretched systems has been studied by ferromagnetic resonance to measure resulting magnetic anisotropy and damping evolutions. All of these experimental studies show that the magnetic properties are mainly affected by the stresses generated during the damage but not by the local discontinuities induced by the numerous cracks and buckles. This is in particular confirmed by the almost zero sensitivity to the damage of the magnetic properties of Ni80Fe20 alloy which is known for its vanishing magnetostriction.

10.
Eur J Trauma Emerg Surg ; 44(2): 231-234, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28280874

RESUMO

PURPOSE: The forearm is prone to raised compartment pressure and it is the second most common site for compartment syndrome. The normal compartment pressure of the forearm should be known and serve as a benchmark for the diagnosis of acute and chronic compartment syndrome. This study was aimed to determine the normal compartment pressures of the forearm using a digital compartment pressure monitor. METHODS: This was a prospective hospital-based study of the uninjured forearm in 30 patients, who presented with closed unilateral forearm fracture at the accident and emergency department of a tertiary health care facility, between June 2012 and December 2013. Approval was sought and obtained from institutions ethical committee. An 18 gauge bevelled-tip needle, attached to a Compass TM digital compartment pressure monitor made by Mirador USA, was used to measure the pressures in the compartments of the forearm. Data obtained were analysed using the Stata 12. Significance was determined at p < 0.05. RESULTS: The mean age was 38.3 ± 18.3 years with male-to-female ratio of 2.3:1. The pressures in the volar compartment of the forearm ranged from 1 to 8 mmHg with a mean ± SD compartment pressure of 4.7 ± 1.5 mmHg. In the dorsal compartment the pressure ranged from 2 to 8 mmHg with a mean ± SD of 4.9 ± 1.7 mmHg SD, while the lateral compartment measurement ranged between 1 and 5 mmHg with a mean ± SD of 3.6 ± 1.1 mmHg. There was significant positive correlation (p < 0.01) between the compartment pressures in the volar, dorsal, and lateral compartments. CONCLUSION: The normal compartment pressure for forearm is 4.4 ± 1.6 mmHg and ranged from 1 to 8 mmHg from this study in our environment. This will serve as reference value when forearm compartment pressure is being measured.


Assuntos
Síndromes Compartimentais/fisiopatologia , Traumatismos do Antebraço/fisiopatologia , Antebraço/fisiologia , Adulto , Feminino , Humanos , Masculino , Nigéria , Pressão , Estudos Prospectivos , Valores de Referência
11.
Clin Med Insights Cardiol ; 10: 157-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27656092

RESUMO

BACKGROUND: Pregnancy is a physiological process associated with an increased hemodynamic load and cardiac structural remodeling. Limited echocardiographic information exists on cardiac chambers, left ventricular (LV) systolic and diastolic functions, and LV mass during trimesters of normal pregnancy among African women. MATERIALS AND METHODS: Echocardiography was done at the beginning of the second trimester, beginning of the third trimester, and middle of the third trimester for 100 normal pregnant women and at one visit for age-matched 100 nonpregnant women. The data were analyzed using the Statistical Package for Social Sciences (SPSS) version 17 software. Analysis of variance was used to compare within trimesters, and a P value of <0.05 was considered significant. RESULTS: The mean (SD) ages of the patients and controls were 28.20 (±5.91) and 28.35 (±6.06) years, respectively (age range = 19-44 years, P = 0.86). Cardiac chambers, LV systolic function, and LV mass and its index increased significantly during pregnancy. A significant increase in A-wave velocity but slight increase in E-wave velocity and a reduction in tissue e' velocity at the septal margin but a progressive increase in a' velocity were also observed (P < 0.05). CONCLUSION: Cardiac chamber dimensions, LV wall thickness, and mass, most indices of LV systolic and diastolic function, though within normal range, were significantly higher in pregnant than in nonpregnant Nigerian women.

12.
Sci Rep ; 6: 28007, 2016 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-27294614

RESUMO

Capacitor-like metal-NiO-metal structures have attracted large interest in non-volatile memory applications based on electric field control of resistance, known as resistive switching (RS). Formation of conducting nanofilaments by the application of an electric field (electroformation) is considered an important pre-requisite for RS. Besides RS, due to the wide band gap and p-type semiconducting nature, NiO has been used to fabricate heterojunctions for photodetector applications. However, very little is known about the electrical and opto-electrical properties of NiO films in planar structure. Here, we demonstrate intriguing photoresponse and electrical behavior in electroformed Pt-NiO-Pt planar structures. While the pristine devices show ohmic electrical behavior and negligible photoresponse, the electroformed devices exhibit a nonlinear rectification behavior and a remarkable photoresponse at low voltage biases. More interestingly, the devices show a dramatic change of sign of rectification under light illumination at higher voltage biases. A polarity dependent and robust gain phenomenon is demonstrated in these devices. The large sensitivity, fast response, simple design and ease of preparation of these planar structures make them attractive for integration with current circuit technologies and various novel opto-electrical applications.

13.
Theriogenology ; 85(5): 862-869, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26643605

RESUMO

Twenty pregnant Yankasa ewes were assigned to three groups to determine the effect of Trypanosoma evansi infection on pregnancy. Groups A and B comprising seven ewes each were infected with approximately 1.0 × 10(6) cells of T evansi per ewe through venepuncture at the second and third trimesters of pregnancy, respectively. Group C comprising six ewes served as uninfected control. There was slight pyrexia in the infected groups (groups A and B) but was absent in group C. The mean body weight, glucose concentration, and packed cell volume of ewes in group A were not significantly different from those in group C throughout the study. There was also no significant difference in mean glucose concentration between groups B and C. However, in group B, mean body weight was significantly (P < 0.05) lower compared to group C at week 2 and from week 4 post infection (pi) till the end of the study; the packed cell volume also significantly (P < 0.05) decreased but at weeks 4 and 6 pi. The mean plasma protein of ewes in group A was significantly (P < 0.05) increased compared to those of group C at weeks 7, 11 pi and thereafter till the end of the study. On the contrary, the plasma protein of ewes in group B decreased significantly (P < 0.05) compared to those in group C at weeks 2 and 6 pi. There were no reproductive losses throughout the study. This was characterized by insignificant differences in the gestation length between ewes in the infected groups (groups A and B) compared with those in group C. However, there were significant (P < 0.05) decreases in lamb birth weights of ewes in group B compared with ewes in groups A and C. Mice inoculation with blood from infected ewes postpartum was parasitemic 18 to 25 days pi, for ewes in group B, whereas none of the mice in groups A and C were parasitemic. Lambs born from the infected groups (groups A and B) were also aparasitemic for 40 days postpartum. It was therefore concluded that the T evansi isolate used caused mild trypanosomosis when infected at third trimester, whereas ewes infected at second trimester were resistant.


Assuntos
Complicações Infecciosas na Gravidez/veterinária , Prenhez , Doenças dos Ovinos/patologia , Ovinos/parasitologia , Tripanossomíase/patologia , Animais , Feminino , Transmissão Vertical de Doenças Infecciosas/veterinária , Modelos Animais , Parasitemia/patologia , Parasitemia/veterinária , Gravidez , Complicações Infecciosas na Gravidez/parasitologia , Complicações Infecciosas na Gravidez/patologia , Resultado da Gravidez , Infecções Protozoárias em Animais/patologia , Doenças dos Ovinos/parasitologia
14.
J Nanosci Nanotechnol ; 15(6): 4332-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26369045

RESUMO

Cobalt/Palladium (Co/Pd) multilayer film and nanodisc samples were fabricated on polyethylene terephthalate (PET) substrates. The effects of surface roughness and grain size of PET substrate, the Co/Pd layer and the Au intermediate layer on the magnetic properties of these samples were investigated. We observed that the coercivity for Co/Pd films deposited directly on a smoother PET substrate is significantly smaller when compared with Co/Pd films deposited at the same time on Au buffer layer. The patterned Co/Pd nanodisc array exhibited a larger coercivity than the corresponding continuous film due to lower probability of finding nucleation sites in reduced film area.

15.
Sci Rep ; 5: 13881, 2015 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-26355430

RESUMO

Magnetic vortex is one of the simplest topologically non-trivial textures in condensed matter physics. It is the ground state of submicron magnetic elements (dots) of different shapes: cylindrical, square etc. So far, the vast majority of the vortex dynamics studies were focused on thin dots with thickness 5-50 nm and only uniform across the thickness vortex excitation modes were observed. Here we explore the fundamental vortex mode in relatively thick (50-100 nm) dots using broadband ferromagnetic resonance and show that dimensionality increase leads to qualitatively new excitation spectra. We demonstrate that the fundamental mode frequency cannot be explained without introducing a giant vortex mass, which is a result of the vortex distortion due to interaction with spin waves. The vortex mass depends on the system geometry and is non-local because of important role of the dipolar interaction. The mass is rather small for thin dots. However, its importance increases drastically with the dot thickness increasing.

16.
Sci Rep ; 5: 10367, 2015 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-26012863

RESUMO

In the emerging field of magnon-spintronics, spin waves are exploited to encode, carry and process information in materials with periodic modulation of their magnetic properties, named magnonic crystals. These enable the redesign of the spin wave dispersion, thanks to its dependence on the geometric and magnetic parameters, resulting in the appearance of allowed and forbidden band gaps for specific propagation directions. In this work, we analyze the spin waves band structure of two-dimensional magnonic crystals consisting of permalloy square antidot lattices with different geometrical parameters. We show that the frequency of the most intense spin-wave modes, measured by Brillouin light scattering, exhibits a universal dependence on the aspect ratio (thickness over width) of the effective nanowire enclosed between adjacent rows of holes. A similar dependence also applies to both the frequency position and the width of the main band gap of the fundamental (dispersive) mode at the edge of the first Brillouin zone. These experimental findings are successfully explained by calculations based on the plane-wave method. Therefore, a unified vision of the spin-waves characteristics in two-dimensional antidot lattices is provided, paving the way to the design of tailored nanoscale devices, such as tunable magnonic filters and phase-shifters, with predicted functionalities.

17.
Phys Rev Lett ; 107(12): 127204, 2011 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-22026795

RESUMO

The dispersion curves of collective spin-wave excitations in a magnonic crystal consisting of a square array of interacting saturated nanodisks have been measured by Brillouin light scattering along the four principal directions of the first Brillouin zone. The experimental data are successfully compared to calculations of the band diagram and of the Brillouin light scattering cross section, performed through the dynamical matrix method extended to include the dipolar interaction between the disks. We found that the fourfold symmetry of the geometrical lattice is reduced by the application of the external field and therefore equivalent directions of the first Brillouin zone are characterized by different dispersion relations of collective spin waves. The dispersion relations are explained through the introduction of a bidimensional effective wave vector that characterizes each mode in this magnonic metamaterial.

18.
Phys Rev Lett ; 107(4): 047205, 2011 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-21867038

RESUMO

We show that periodic magnetic nanostructures represent a perfect system for studying excitations on disordered periodical lattices because of the possibility of controlled variation of the degree of disorder by varying the applied magnetic field. Magnetic force microscopy images and ferromagnetic resonance (FMR) data collected inside minor hysteresis loops for a periodic array of Permalloy nanowires were used to demonstrate correlation between the type of FMR response and the degree of disorder of the magnetic ground state.

19.
J Nanosci Nanotechnol ; 11(3): 2615-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21449438

RESUMO

An understanding of the spin dynamics of nanoscale magnetic elements is important for their applications in magnetic sensing and storage. Inhomogeneity of the demagnetizing field in a non-ellipsoidal magnetic element results in localization of spin waves near the edge of the element. However, relative little work has been carried out to investigate the effect of the applied magnetic fields on the nature of such localized modes. In this study, micromagnetic simulations are performed on an equilateral triangular nanomagnet to investigate the magnetic field dependence of the mode profiles of the lowest-frequency spin wave. Our findings reveal that the lowest-frequency mode is localized at the base edge of the equilateral triangle. The characteristics of its mode profile change with the ground state magnetization configuration of the nanotriangle, which, in turn, depends on the magnitude of the in-plane applied magnetic field.


Assuntos
Desenho Assistido por Computador , Magnetismo/instrumentação , Modelos Teóricos , Nanotecnologia/instrumentação , Simulação por Computador , Campos Eletromagnéticos , Desenho de Equipamento , Análise de Falha de Equipamento , Espalhamento de Radiação
20.
J Nanosci Nanotechnol ; 11(3): 2657-60, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21449448

RESUMO

Most experimental investigations into magnonic bandgaps are based on structures composed of single-constituent magnetic materials. Here we report Brillouin and numerical studies of the spin dynamics of a bi-component magnonic crystal, viz. a one-dimensional periodic array of alternating permalloy and cobalt 150 nm-wide nanostripes. Our measurements, together with those for a similar crystal composed of 250 nm-wide nanostripes, suggest that for a stripe width ratio of 1:1, the bandgap width of such magnonic arrays increases with crystal lattice constant. The bandgap parameters are strongly dependent on external magnetic field. This magnetic-field tunability of the bandgap is expected to be a crucial property of devices based on magnonic crystals. The agreement between numerical calculations, based on finite element analysis, and the experimental data is generally good.


Assuntos
Cristalização/métodos , Magnetismo/instrumentação , Nanoestruturas/química , Nanotecnologia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Nanoestruturas/ultraestrutura , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA