Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Trop Pediatr ; 68(6)2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36370460

RESUMO

PURPOSE: Infant respiratory distress is  a significant cause of mortality globally. Bubble continuous positive airway pressure (CPAP) is a simple and effective therapy, but sicker infants may require additional support such as non-invasive positive-pressure ventilation (NIPPV). We investigated the feasibility of a simple, low-cost, non-electric bubble NIPPV device. METHODS: In this cross-over feasibility study, seven newborns with moderate respiratory distress (Downes score ≥ 3), weight > 1500 g and gestational age > 32 weeks were randomized to  4 h of treatment with bubble CPAP (5-8 cm H2O) vs. bubble NIPPV (Phigh 8-10 cm H2O/Plow 5-8 cm H2O) followed by 4 h of the alternate treatment. Treatment order (CPAP vs. NIPPV) was randomized. Outcome measures included hourly vital signs, Downes score and O2 saturation. Adverse events including pneumothorax, nasal septal necrosis, necrotizing enterocolitis and death before discharge were also recorded. RESULTS: It took nurses 39 (7.3) s to assemble the bubble NIPPV device. Patients had similar vital signs and Downes scores on both treatments; median (IQR) values on bubble CPAP vs. bubble NIPPV were: heart rate 140 (134.5, 144), 140 (134.5, 144); respiratory rate 70 (56, 80), 65 (58, 82), Downes score 4 (3, 5.75), 4 (3, 5), O2 96 (94, 98), 97 (96, 98). All newborns survived to discharge and there were no adverse events. . CONCLUSIONS: A simple, low-cost, non-electric method of providing NIPPV for newborns with respiratory distress is feasible in limited resource settings. Randomized-controlled trials comparing bubble CPAP and bubble NIPPV are justified.


Assuntos
Síndrome do Desconforto Respiratório do Recém-Nascido , Síndrome do Desconforto Respiratório , Recém-Nascido , Humanos , Lactente , Ventilação com Pressão Positiva Intermitente/métodos , Recém-Nascido Prematuro , Estudos de Viabilidade , Pressão Positiva Contínua nas Vias Aéreas/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
2.
Front Pediatr ; 10: 954975, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36389382

RESUMO

Respiratory disease is a leading cause of death in children under 5 years of age worldwide, and most of these deaths occur in low- to middle-income countries (LMICs) where advanced respiratory care technology is often limited. Much of the equipment required to provide advanced respiratory care is unavailable in these areas due to high costs, the need for specialty trained personnel, and myriad other resource constraints that limit uptake and sustainable use of these devices, including reliable access to electricity, sensitive equipment needing frequent maintenance, single-patient-use supplies, and lack of access to sterilization equipment. Compounding the problem, pediatrics is uniquely challenging in that one size does not fit all, or even most patients. Despite these substantial barriers, numerous innovations in respiratory care technology have been made in recent years that have brought increasing access to high quality respiratory care in some of the most remote areas of the world. In this article, we intend to review the global burden of respiratory diseases for children, highlight the prototypical innovations that have been made in bringing respiratory care to LMICs, spotlight some of the technologies being actively developed to improve respiratory care in resource-constrained settings, and conclude with a discussion highlighting areas where further innovation is still needed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA