Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artif Organs ; 35(4): E91-100, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21375547

RESUMO

Labeling of hepatocytes with micron-sized iron oxide particles (MPIOs) enables cell detection using clinical magnetic resonance equipment. For clinical applications, large numbers of cells must be labeled in a simple and rapid manner and have to be applied in suspension. However, all existing protocols are based on adhesion culture labeling with subsequent resuspension, only suitable for small experimental settings. The aim of this study was to investigate the feasibility of preparing MPIO-labeled primary human hepatocytes in a temporary suspension culture. Human hepatocytes were isolated from 16 donors and labeled with MPIOs in suspension, using the Rotary Cell Culture System. Particle incorporation was investigated by light and electron microscopy. Cells were compared with adhesion culture-labeled and subsequently enzymatically resuspended cells. During a period of 5 days, hepatocyte-specific parameters of cell damage (aspartate aminotransferase and alanine aminotransferase) and metabolic activity (urea and albumin) were analyzed (n=7). Suspension cultures showed a higher outcome in cell recovery compared with the conventional labeling method. When incubated with 180 particles/viable cell for 4 h, the mean particle uptake was 28.8 particles/cell at a labeling efficiency of 95.1%. Labeling in suspension had no adverse effects on cell integrity or metabolic activity. We conclude that labeling of human hepatocytes in suspension is feasible and simple and may serve future large-scale processing of cells.


Assuntos
Compostos Férricos/análise , Hepatócitos/ultraestrutura , Coloração e Rotulagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Cultura de Células , Sobrevivência Celular , Células Cultivadas , Hepatócitos/citologia , Humanos , Microscopia Eletrônica , Microscopia de Contraste de Fase , Pessoa de Meia-Idade , Tamanho da Partícula , Adulto Jovem
2.
Mol Imaging Biol ; 13(4): 613-22, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20737221

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) is a promising approach for non-invasive monitoring after liver cell transplantation. We compared in vitro labeling of human liver cells with nano-sized (SPIO) and micron-sized iron oxide particles (MPIO). PROCEDURES: The cellular iron load was quantified and phantom studies were performed using 3.0-T MRI. Transferrin receptor and ferritin gene expression, reactive oxygen species (ROS) formation, transaminase leakage, and urea synthesis were investigated over 6 days. RESULTS: Incubation with MPIO produced stronger signal extinctions in MRI at similar iron loads within shorter labeling time. MPIO had no negative effects on the cellular iron homeostasis or cell performance, whereas SPIO caused temporary ROS formation and non-physiologic activation of the iron metabolic pathway. CONCLUSIONS: Our findings suggest that MPIO are suited for clinical translation of strategies for cellular imaging with MRI. Attention should be paid to iron release and oxidative stress caused by biodegradable contrast agents.


Assuntos
Meios de Contraste/metabolismo , Hepatócitos/metabolismo , Fígado/citologia , Imageamento por Ressonância Magnética/métodos , Coloração e Rotulagem , Pesquisa Translacional Biomédica , Ferritinas/genética , Ferritinas/metabolismo , Óxido Ferroso-Férrico/metabolismo , Regulação da Expressão Gênica , Hepatócitos/citologia , Humanos , Ferro/metabolismo , Pessoa de Meia-Idade , Espécies Reativas de Oxigênio/metabolismo , Receptores da Transferrina/metabolismo
3.
Cell Med ; 1(3): 123-35, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-27004132

RESUMO

Liver cell transplantation (LCT) is a promising treatment approach for certain liver diseases, but clinical implementation requires methods for noninvasive follow-up. Labeling with superparamagnetic iron oxide particles can enable the detection of cells with magnetic resonance imaging (MRI). We investigated the feasibility of monitoring transplanted liver cells by MRI in a preclinical swine model and used this approach to evaluate different routes for cell application. Liver cells were isolated from landrace piglets and labeled with micron-sized iron oxide particles (MPIO) in adhesion. Labeled cells (n = 10), native cells (n = 3), or pure particles (n = 4) were transplanted to minipigs via intraportal infusion into the liver, direct injection into the splenic parenchyma, or intra-arterial infusion to the spleen. Recipients were investigated by repeated 3.0 Tesla MRI and computed tomography angiography up to 8 weeks after transplantation. Labeling with MPIO, which are known to have a strong effect on the magnetic field, enabled noninvasive detection of cell aggregates by MRI. Following intraportal application, which is commonly applied for clinical LCT, MRI was able to visualize the microembolization of transplanted cells in the liver that were not detected by conventional imaging modalities. Cells directly injected into the spleen were retained, whereas cell infusions intra-arterially into the spleen led to translocation and engraftment of transplanted cells in the liver, with significantly fewer microembolisms compared to intraportal application. These findings demonstrate that MRI can be a valuable tool for noninvasive elucidation of cellular processes of LCT and-if clinically applicable MPIO are available-for monitoring of LCT under clinical conditions. Moreover, the results clarify mechanisms relevant for clinical practice of LCT, suggesting that the intra-arterial route to the spleen deserves further evaluation.

4.
Tissue Eng Part C Methods ; 15(4): 681-6, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19422300

RESUMO

Detection of cells after transplantation is necessary for quality control in regenerative medicine. Labeling with micron-sized iron oxide particles enables noninvasive detection of single cells by magnetic resonance imaging. However, techniques for evaluation of the particle uptake are challenging. The aim of this study was to investigate continuum source atomic absorption spectrometry (CSAAS) for this purpose. Porcine liver cells were labeled with micron-sized iron oxide particles, and the iron concentration of the cell samples was investigated by a CSAAS spectrometer equipped with a Perkin-Elmer THGA graphite furnace. The weak iron line at 305.754 nm provides only about 1/600 sensitivity of the iron resonance line at 248.327 nm and was used for CSAAS measurements. Iron concentrations measured from labeled cells ranged from 5.8 +/- 0.3 to 25.8 +/- 0.9 pg Fe/cell, correlating to an uptake of 8.2 +/- 0.5 to 25.7 +/- 0.8 particles/cell. The results were verified by standardized morphometric evaluation. CSAAS enabled rapid quantification of particle load from small quantities of cells without extensive preparation steps. Thereby, CSAAS could be used for quality control in a clinical setting of cell transplantation.


Assuntos
Compostos Férricos/química , Compostos Férricos/farmacologia , Hepatócitos/citologia , Hepatócitos/efeitos dos fármacos , Tamanho da Partícula , Espectrofotometria Atômica/métodos , Coloração e Rotulagem/métodos , Animais , Sobrevivência Celular/efeitos dos fármacos , Masculino , Sus scrofa , Temperatura
5.
J Cell Mol Med ; 12(4): 1384-94, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18410523

RESUMO

Transplantation of primary human hepatocytes is a promising approach in certain liver diseases. For the visualization of the hepatocytes during and following cell application and the ability of a timely response to potential complications, a non-invasive modality for imaging the transplanted cells has to be established. The aim of this study was to label primary human hepatocytes with micron-sized iron oxide particles (MPIOs), enabling the detection of cells by clinical magnetic resonance imaging (MRI). Primary human hepatocytes isolated from 13 different donors were used for the labelling experiments. Following the dose-finding studies, hepatocytes were incubated with 30 particles/cell for 4 hrs in an adhesion culture. Particle incorporation was investigated via light, fluorescence and electron microscopy, and labelled cells were fixed and analysed in an agarose suspension by a 3.0 Tesla MR scanner. The hepatocytes were enzymatically resuspended and analysed during a 5-day reculture period for viability, total protein, enzyme leakage (aspartate aminotransferase [AST], lactate dehydrogenase [LDH]) and metabolic activity (urea, albumin). A mean uptake of 18 particles/cell could be observed, and the primary human hepatocytes were clearly detectable by MR instrumentation. The particle load was not affected by resuspension and showed no alternations during the culture period. Compared to control groups, labelling and resuspension had no adverse effects on the viability, enzyme leakage and metabolic activity of the human hepatocytes. The feasibility of preparing MPIO-labelled primary human hepatocytes detectable by clinical MR equipment was shown in vitro. MPIO-labelled cells could serve for basic research and quality control in the clinical setting of human hepatocyte transplantation.


Assuntos
Compostos Férricos/metabolismo , Hepatócitos/citologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Células Cultivadas , Hepatócitos/metabolismo , Hepatócitos/ultraestrutura , Humanos , Sefarose , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA