Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Nat Med ; 30(7): 2020-2029, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38977913

RESUMO

Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-38970599

RESUMO

BACKGROUND: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts. OBJECTIVE: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates. METHODS: This was a multicenter collaboration study. At 32 centers, we selected patients with an initial diagnosis of IVF and recurrent arrhythmia at follow-up without antiarrhythmic drugs, in whom mapping demonstrated Purk or MiCM substrate. We analyzed variables related to previous ectopy, sinus rate preceding VF, trigger, and initial VF cycle lengths. Logistic regression with cross validation was used to evaluate the performance of criteria to discriminate Purk or MiCM substrates. RESULTS: Among 95 patients (35 women, age 35 ± 11 years) meeting the inclusion criteria, IVF was associated with MiCM in 41 and Purk in 54 patients. A total of 117 arrhythmia recurrences including 91% VF were recorded on defibrillator. Three variables were mostly discriminant. Sinus tachycardia (≤570 ms) was more frequent in MiCM (35.9% vs 13.4%, P = 0.014) whereas short-coupled (<350 ms) triggers were most frequent in Purk-related VF (95.5% vs 23.1%, P = 0.001), which also had shorter VFCLs (182 ± 15 ms vs 215 ± 24 ms, P < 0.001).The multivariable combination provided the highest prediction (accuracy = 0.93 ± 0.05, range 0.833-1.000), discriminating 81% of IVF substrates with a high probability (>80%). Ectopy were inconsistently present before VF. CONCLUSIONS: Characteristics of arrhythmia recurrences on implantable cardioverter- defibrillator provide phenotypic markers of the distinct and hidden substrates underlying IVF. These findings have significant clinical and genetic implications.

3.
Rev Port Cardiol ; 43(6): 341-349, 2024 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38615878

RESUMO

INTRODUCTION AND OBJECTIVES: Catheter ablation (CA) is effective in the treatment of ventricular tachycardia (VT). Although some observational data suggest patients with non-ischemic cardiomyopathy (NICM) have less favorable outcomes when compared to those with an ischemic etiology (ICM), direct comparisons are rarely reported. We aimed to compare the outcomes of VT ablation in a propensity-score matched population of ICM or NICM patients. METHODS: Single-center retrospective study of consecutive patients undergoing VT ablation from 2012 to 2023. A propensity score (PS) was used to match ICM and NICM patients in a 1:1 fashion according to age, sex, left ventricular ejection fraction (LVEF), NYHA class, electrical storm (ES) at presentation, and previous endocardial ablation. The outcomes of interest were VT-free survival and all-cause mortality. RESULTS: The PS yielded two groups of 71 patients each (mean age 63±10 years, 92% male, mean LVEF 35±10%, 36% with ES at presentation, and 23% with previous ablation), well matched for baseline characteristics. During a median follow-up of 2.3 (interquartile range IQR 1.3-3.8) years, patients with NICM had a significantly lower VT-free survival (53.5% vs. 69.0%, log-rank p=0.037), although there were no differences regarding all-cause mortality (22.5% vs. 16.9%, log-rank p=0.245). Multivariate analysis identified NICM (HR 2.34 [95% CI 1.32-4.14], p=0.004), NYHA class III/IV (HR 2.11 [95% CI 1.11-4.04], p=0.024), and chronic kidney disease (HR 2.23 [95% CI 1.25-3.96], p=0.006), as independent predictors of VT recurrence. CONCLUSION: Non-ischemic cardiomyopathy patients were at increased risk of VT recurrence after ablation, although long-term mortality did not differ.


Assuntos
Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Pontuação de Propensão , Taquicardia Ventricular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Taquicardia Ventricular/cirurgia , Ablação por Cateter/métodos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Cardiomiopatias/cirurgia , Cardiomiopatias/complicações , Resultado do Tratamento , Idoso
6.
J Electrocardiol ; 80: 143-150, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37390586

RESUMO

BACKGROUND AND AIM: A recent study using an epicardial-only electrocardiographic imaging (ECGI), suggests that the agreement of ECGI activation mapping and that of the contact mapping for ventricular arrhythmias (VA) is poor. The aim of this study was to assess the diagnostic value of two endo-epicardial ECGI systems using different cardiac sources and the agreement between them. METHODS: We performed 69 ECGI procedures in 52 patients referred for ablation of VA at our center. One system based on the extracellular potentials was used in 26 patients, the other based on the equivalent double layer model in 9, and both in 17 patients. The first uses up to 224 leads and the second just the 12­lead ECG. The localization of the VA was done using a segmental model of the ventricles. A perfect match (PM) was defined as a predicted location within the same anatomic segment, whereas a near match (NM) as a predicted location within the same segment or a contiguous one. RESULTS: 44 patients underwent ablation, corresponding to 58 ECGI procedures (37 with the first and 21 with the second system). The percentage of PMs and NMs was not significantly different between the two systems, respectively 76% and 95%, p = 0.077, and 97% and 100%, p = 1.000. In 14 patients that underwent ablation and had the ECGI performed with both systems, raw agreement for PMs was 79%, p = 0.250 for disagreement. CONCLUSIONS: ECGI systems were useful to identify the origin of the VAs, and the results were reproducible regardless the cardiac source.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Eletrocardiografia/métodos , Arritmias Cardíacas/diagnóstico , Coração , Diagnóstico por Imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36935638

RESUMO

AIMS: Insertable cardiac monitors (ICMs) are indicated for long-term monitoring of unexplained syncope or palpitations, and for detection of bradycardia, ventricular tachycardia, and/or atrial fibrillation (AF). The aim of our study was to evaluate the safety and clinical value associated with a new generation ICM (Confirm Rx™, Abbott, Illinois, USA), featuring a new remote monitoring system based on smartphone patient applications. METHODS AND RESULTS: The SMART Registry is an international prospective observational study. The main endpoints were ICM safety (incidence of serious adverse device and procedure-related events (SADEs) at 1 month), ICM clinical value (incidence of device-detected true arrhythmias and of clinical diagnoses and interventions), and patient-reported experience measurements (PREMs). A total of 1400 subjects were enrolled. ICM indications included syncope (49.1%), AF (18.8%), unexplained palpitations (13.6%), risk of ventricular arrhythmia (6.6%), and cryptogenic stroke (6.0%). Freedom from SADEs at 1 month was 99.4% (95% Confidence Interval: 98.8-99.7%). In the 6-month monitoring period, the ICM detected true cardiac arrhythmias in 45.7% of patients and led to clinical interventions in a relevant proportion of patients; in particular, a pacemaker implant was performed after bradycardia detection in 8.9% of subjects who received an ICM for syncope and oral anticoagulation therapy was indicated after AF detection in 15.7% of subjects with cryptogenic stroke. PREMs showed that 78.2% of subjects were satisfied with the remote monitoring patient app. CONCLUSION: The evaluated ICM is associated with an excellent safety profile and high diagnostic yield. Patients reported positive experiences associated with the use of their smartphone for the device remote monitoring.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Humanos , Bradicardia/complicações , Eletrocardiografia Ambulatorial/métodos , Fibrilação Atrial/diagnóstico , Síncope/diagnóstico , Síncope/epidemiologia , Sistema de Registros
8.
Europace ; 25(4): 1458-1466, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36857597

RESUMO

AIMS: Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. METHODS AND RESULTS: Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6-24 months of post-implant. Latest electrically activated site and the distance to LVPS (dp) were assessed. Left ventricular end-systolic volume (LVESV) reduction of ≥15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and dp. Of 111 studied patients [64 ± 11 years, EF 28 ± 6%, implant duration 12 ± 5 months (mean ± SD), 98% had LBBB, 38% IHD], 67% responded at 10 ± 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. dp was 42 ± 23 mm [31 ± 14 mm for responders vs. 63 ± 24 mm non-responders (P < 0.001)]. Longer dp and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. dp of 47 mm delineated responders and non-responders (AUC 0.931). CONCLUSION: The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Eletrocardiografia/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Função Ventricular Esquerda
9.
Rev Port Cardiol ; 42(3): 277.e1-277.e7, 2023 03.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36693523

RESUMO

Although not routinely used, cardioneuroablation or modulation of the cardiac autonomic nervous system has been proposed as an alternative approach to treat young individuals with enhanced vagal tone and significant atrioventricular (AV) disturbances. We report the case of a 42-year-old athlete with prolonged ventricular pauses associated with sinus bradycardia and paroxysmal episodes of AV block (maximum of 6.6 s) due to enhanced vagal tone who was admitted to our hospital for pacemaker implantation. Cardiac magnetic resonance and stress test were normal. Although he was asymptomatic, safety concerns regarding possible neurological damage and sudden cardiac death were raised, and he accordingly underwent electrophysiological study (EPS) and cardiac autonomic denervation. Mapping and ablation were anatomically guided and radiofrequency pulses were delivered at empirical sites of ganglionated plexi. Modulation of the parasympathetic system was confirmed through changes in heart rate and AV nodal conduction properties associated with a negative cardiac response to atropine administration. After a follow-up of nine months, follow-up 24-hour Holter revealed an increase in mean heart rate and no AV disturbances, with rare non-significant ventricular pauses, suggesting that this technique may become a safe and efficient procedure in this group of patients.


Assuntos
Bloqueio Atrioventricular , Ablação por Cateter , Masculino , Humanos , Adulto , Bradicardia/cirurgia , Resultado do Tratamento , Coração , Denervação , Ablação por Cateter/métodos
10.
J Interv Card Electrophysiol ; 66(1): 87-94, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35258753

RESUMO

BACKGROUND: Direct comparisons of combined (C-ABL) and non-combined (NC-ABL) endo-epicardial ventricular tachycardia (VT) ablation outcomes are scarce. We aimed to investigate the long-term clinical efficacy and safety of these 2 strategies in ischemic heart disease (IHD) and non-ischemic cardiomyopathy (NICM) populations. METHODS: Multicentric observational registry included 316 consecutive patients who underwent catheter ablation for drug-resistant VT between January 2008 and July 2019. Primary and secondary efficacy endpoints were defined as VT-free survival and all-cause death after ablation. Safety outcomes were defined by 30-day mortality and procedure-related complications. RESULTS: Most of the patients were male (85%), with IHD (67%) and mean age of 63 ± 13 years. During a mean follow-up of 3 ± 2 years, 117 (37%) patients had VT recurrence and 73 (23%) died. Multivariate survival analysis identified electrical storm (ES) at presentation, IHD, left ventricular ejection fraction (LVEF), New York Heart Association (NYHA) functional class III / IV, and C-ABL as independent predictors of VT recurrence. In 135 patients undergoing repeated procedures, only C-ABL and ES were independent predictors of relapse. The identified independent predictors of mortality were C-ABL, ES, LVEF, age, and NYHA class III / IV. C-ABL survival benefit was only seen in patients with a previous ablation (P for interaction = 0.04). Mortality at 30 days was similar between NC-ABL and C-ABL (4% vs. 2%, respectively, P = 0.777), as was complication rate (10.3% vs. 15.1%, respectively, P = 0.336). CONCLUSION: A combined or sequential endo-epicardial VT ablation strategy was associated with lower VT recurrence and lower all-cause death in IHD and NICM patients undergoing repeated procedures. Both approaches seemed equally safe.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico , Função Ventricular Esquerda , Isquemia Miocárdica/complicações , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva
12.
J Cardiovasc Electrophysiol ; 33(11): 2308-2321, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35938385

RESUMO

INTRODUCTION: Frequently, low voltage areas (LVAs) and diastolic potentials (DPs) are present at ablation sites in sinus rhythm in patients with idiopathic premature ventricular contractions (PVCs). OBJECTIVE: Validate these findings as substrates for PVCs and evaluate the feasibility of a simplified substrate approach based on LVAs and DPs for ablation of idiopathic outflow tract PVCs, in patients with a low PVC burden during the procedure. METHODS: Prospective single-arm clinical trial at two centers with comparison with a historical group, matched to age and gender. The study group consisted of consecutive patients referred for ablation of frequent idiopathic PVCs with inferior axis, that presented with less than two PVCs/min in first 5 min of the procedure. The ablation was based on fast mapping of the right ventricular outflow tract in sinus rhythm looking for LVAs and DPs, defined as isolated small amplitude potentials occurring after the T wave of the surface echocardiogram. The area with LVAs and DPs was tagged, and a simplified activation mapping of the PVCs was done in that area. The procedure time, success rate, and recurrence rate were compared with the historical group in whom ablation was performed based on activation and pace mapping only. A validation group without PVCs was also studied to assess the prevalence of LVAs and DPs in the general population. RESULTS: The study (n = 38), historical (n = 38), and validation (n = 38) groups did not differ in relation to age or gender. Prevalence of LVAs and DPs was significantly higher in the study group in comparison with the validation group, respectively, 71% versus 11%, p < 0.0001 and 87% versus 8%, p < 0.0001. Procedure time was significantly lower in the study group when comparing to the historical group, 130 (100-164) versus 183 (160-203) min, p < 0.0001 and the success rate was significantly higher, 90% versus 64%, p = 0.013. The recurrence rate in patients with a successful ablation was not significantly different between both groups, Log-rank = 0.125. CONCLUSION: The prevalence of LVAs and DPs was significantly higher in the study group than in the validation group. The proposed approach proved to be feasible, faster, and more efficient than the historical approach.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ventrículos do Coração , Prevalência , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 33(11): 2322-2334, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35971685

RESUMO

BACKGROUND: Previous studies have reported the presence of subtle abnormalities in the right ventricular outflow tract (RVOT) in patients with apparently normal hearts and ventricular arrhythmias (VAs) from the RVOT, including the presence of low voltage areas (LVAs). This LVAs seem to be associated with the presence of ST-segment elevation in V1 or V2 leads at the level of the 2nd intercostal space (ICS). OBJECTIVE: Our aim was to validate an electrocardiographic marker of LVAs in the RVOT in patients with idiopathic outflow tract VAs. METHODS: A total of 120 patients were studied, 84 patients referred for ablation of idiopathic VAs with an inferior axis by the same operator, and a control group of 36 patients without VAs. Structural heart disease including arrhythmogenic right ventricular cardiomyopathy was ruled out in all patients. An electrocardiogram was performed with V1-V2 at the 2nd ICS, and ST-segment elevation ≥1 mm and T-wave inversion beyond V1 were assessed. Bipolar voltage map of the RVOT was performed in sinus rhythm (0.5-1.5 mV color display). Areas with electrograms <1.5 mV were considered LVAs, and their presence was assessed. We compared three groups, VAs from the RVOT (n = 66), VAs from the LVOT (n = 18) and Control group (n = 36). ST-elevation, T-wave inversion and left versus right side of the VAs were tested as predictors of LVAs, respective odds ratio (ORs) (95% confidence interval [CI]) and p values, were calculated with univariate logist regression. Variables with a p < .005 were included in the multivariate analysis. RESULTS: ST-segment elevation, T-wave inversion and LVAs were present in the RVOT group, LVOT group and Control group as follows: (62%, 17%, and 6%, p < .0001), (33%, 29%, and 0%, p = .001) and (62%, 25%, and 14%, p < .0001). The ST-segment elevation, T-wave inversion and right-sided VAs were all predictors of LVAs, respective unadjusted ORs (95% CI), p values were, 32.31 (11.33-92.13), p < .0001, 4.137 (1.615-10.60), p = .003 and 8.200 (3.309-20.32), p < .0001. After adjustment, the only independent predictor of LVAs was the ST-segment elevation, with an adjusted OR (95% CI) of 20.94 (6.787-64.61), p < .0001. CONCLUSION: LVAs were frequently present in patients with idiopathic VAs. ST-segment elevation was the only independent predictor of their presence.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Arritmias Cardíacas , Eletrocardiografia , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
14.
J Electrocardiol ; 73: 68-75, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35667215

RESUMO

AIMS: Evaluate right ventricular outflow tract (RVOT) activation duration (AD) and speed, invasively and with the electrocardiographic imaging (ECGI), as predictors of the origin of the PVCs, validating the ECGI. METHODS: 18 consecutive patients, 8 males, median age 55 (35-63) years that underwent ablation of PVCs with inferior axis and had ECGI performed before ablation. Isochronal activation maps of the RVOT in PVC were obtained with the ECGI and invasively. Total RVOT AD was measured as the time between earliest and latest activated region, and propagation speed by measuring the area of the first 10 ms of activation. Cut-off values for AD, activation speed and number of 10 ms isochrones to predict the origin of the PVCs, were obtained with the ROC curve analysis. Agreement between methods was done with Pearson correlation test and Bland-Altman plot. RESULTS: PVCs originated from the RVOT in 11 (61%) patients. The stronger predictor of PVC origin was the AD. The median AD in PVCs from RVOT was significantly longer than from outside the RVOT, both with ECGI and invasively, respectively 62 (58-73) vs 37 (33-40) ms, p < 0.0001 and 68 (60-75) vs 35 (29-41) ms, p < 0.0001. Agreement between the two methods was good (r = 0.864, p < 0.0001). The cut-off value of 43 ms for AD measured with ECGI predicted the origin of the PVCs with a sensitivity and specificity of 100%. CONCLUSIONS: We found good agreement between ECGI and invasive map. The AD measured with ECGI was the best predictor of the origin of the PVCs.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Ventrículos do Coração , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
15.
Arq. bras. cardiol ; 118(4): 737-742, Apr. 2022. tab, graf
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1374341

RESUMO

Resumo Fundamento O tecido adiposo epicárdico (TAE) tem sido associado à fibrilação atrial (FA), mas seus mecanismos fisiopatológicos permanecem obscuros. Objetivos Medir a correlação entre TAE e fibrose do átrio esquerdo (AE), e avaliar sua capacidade de prever recidiva após o isolamento da veia pulmonar (IVP). Métodos Pacientes com FA inscritos para um primeiro procedimento de IVP foram submetidos à tomografia computadorizada (TC) cardíaca e ressonância magnética cardíaca (RMC) em menos de 48 horas. Quantificou-se o TAECE em imagens de TC realçadas com contraste no nível do tronco da coronária esquerda. Quantificou-se a fibrose do AE em RMC tridimensional com realce tardio isotrópico de 1,5 mm. Após o isolamento da veia pulmonar (IVP), os pacientes foram submetidos a seguimento para checar a recidiva da FA. A significância estatística foi definida com p<0,05. Resultados A maioria dos 68 pacientes (46 homens, idade 61±12 anos) tinha FA paroxística (71%, n=48). Os pacientes apresentavam volume TAECE mediano de 2,4 cm3/m2 (intervalo interquartil [IIQ] 1,6-3,2 cm3/m2) e um volume médio de fibrose do AE de 8,9 g (IIQ 5-15 g). A correlação entre TAECE e fibrose do AE foi estatisticamente significativa, mas fraca (coeficiente de correlação de postos de Spearman = 0,40, p=0,001). Durante um seguimento médio de 22 meses (IIQ 12-31), 31 pacientes (46%) tiveram recidiva da FA. A análise multivariada produziu dois preditores independentes de recidiva da FA: TAECE (FC 2,05, IC de 95% 1,51-2,79, p<0,001) e FA não paroxística (FC 2,36, IC de 95% 1,08-5,16, p=0,031). Conclusão A correlação fraca entre TAE e AE sugere que a fibrose do AE não é o principal mecanismo que liga o TAE e a FA. O TAE mostrou-se mais fortemente associado à recidiva da FA do que à fibrose do AE, corroborando a existência de outros mediadores mais importantes do TAE e da FA.


Abstract Background Epicardial adipose tissue (EAT) has been associated with atrial fibrillation (AF), but its pathophysiological mechanisms remain unclear. Objectives To measure the correlation between EAT and left atrium (LA) fibrosis, and to assess their ability to predict relapse after pulmonary vein isolation (PVI). Methods Patients with AF enrolled for a first PVI procedure underwent both cardiac computerized tomography (CT) and cardiac magnetic resonance (CMR) imaging within less than 48 hours. EATLMwas quantified on contrast-enhanced CT images at the level of the left main. LA fibrosis was quantified on isotropic 1.5 mm 3D delayed enhancement CMR. After pulmonary vein isolation (PVI), patients were followed up for AF relapse. Statistical significance was set at p<0.05. Results Most of the 68 patients (46 men, age 61±12 years) had paroxysmal AF (71%, n=48). Patients had a median EATLMvolume of 2.4 cm3/m2(interquartile range [IQR] 1.6-3.2 cm3/m2), and a median amount of LA fibrosis of 8.9 g (IQR 5-15 g). The correlation between EATLMand LA fibrosis was statistically significant but weak (Spearman's R=0.40, p=0.001). During a median follow-up of 22 months (IQR 12-31), 31 patients (46%) had AF relapse. Multivariate analysis yielded two independent predictors of AF relapse: EATLM(HR 2.05, 95% CI 1.51-2.79, p<0.001), and non-paroxysmal AF (HR 2.36, 95% CI 1.08-5.16, p=0.031). Conclusion The weak correlation between EAT and LA suggests that LA fibrosis is not the main mechanism linking EAT and AF. EAT was more strongly associated with AF relapse than LA fibrosis, supporting the existence of other more important mediators of EAT and AF.

16.
Arq Bras Cardiol ; 118(4): 737-742, 2022 04.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35137779

RESUMO

BACKGROUND: Epicardial adipose tissue (EAT) has been associated with atrial fibrillation (AF), but its pathophysiological mechanisms remain unclear. OBJECTIVES: To measure the correlation between EAT and left atrium (LA) fibrosis, and to assess their ability to predict relapse after pulmonary vein isolation (PVI). METHODS: Patients with AF enrolled for a first PVI procedure underwent both cardiac computerized tomography (CT) and cardiac magnetic resonance (CMR) imaging within less than 48 hours. EATLMwas quantified on contrast-enhanced CT images at the level of the left main. LA fibrosis was quantified on isotropic 1.5 mm 3D delayed enhancement CMR. After pulmonary vein isolation (PVI), patients were followed up for AF relapse. Statistical significance was set at p<0.05. RESULTS: Most of the 68 patients (46 men, age 61±12 years) had paroxysmal AF (71%, n=48). Patients had a median EATLMvolume of 2.4 cm3/m2(interquartile range [IQR] 1.6-3.2 cm3/m2), and a median amount of LA fibrosis of 8.9 g (IQR 5-15 g). The correlation between EATLMand LA fibrosis was statistically significant but weak (Spearman's R=0.40, p=0.001). During a median follow-up of 22 months (IQR 12-31), 31 patients (46%) had AF relapse. Multivariate analysis yielded two independent predictors of AF relapse: EATLM(HR 2.05, 95% CI 1.51-2.79, p<0.001), and non-paroxysmal AF (HR 2.36, 95% CI 1.08-5.16, p=0.031). CONCLUSION: The weak correlation between EAT and LA suggests that LA fibrosis is not the main mechanism linking EAT and AF. EAT was more strongly associated with AF relapse than LA fibrosis, supporting the existence of other more important mediators of EAT and AF.


FUNDAMENTO: O tecido adiposo epicárdico (TAE) tem sido associado à fibrilação atrial (FA), mas seus mecanismos fisiopatológicos permanecem obscuros. OBJETIVOS: Medir a correlação entre TAE e fibrose do átrio esquerdo (AE), e avaliar sua capacidade de prever recidiva após o isolamento da veia pulmonar (IVP). MÉTODOS: Pacientes com FA inscritos para um primeiro procedimento de IVP foram submetidos à tomografia computadorizada (TC) cardíaca e ressonância magnética cardíaca (RMC) em menos de 48 horas. Quantificou-se o TAECE em imagens de TC realçadas com contraste no nível do tronco da coronária esquerda. Quantificou-se a fibrose do AE em RMC tridimensional com realce tardio isotrópico de 1,5 mm. Após o isolamento da veia pulmonar (IVP), os pacientes foram submetidos a seguimento para checar a recidiva da FA. A significância estatística foi definida com p<0,05. RESULTADOS: A maioria dos 68 pacientes (46 homens, idade 61±12 anos) tinha FA paroxística (71%, n=48). Os pacientes apresentavam volume TAECE mediano de 2,4 cm3/m2 (intervalo interquartil [IIQ] 1,6­3,2 cm3/m2) e um volume médio de fibrose do AE de 8,9 g (IIQ 5­15 g). A correlação entre TAECE e fibrose do AE foi estatisticamente significativa, mas fraca (coeficiente de correlação de postos de Spearman = 0,40, p=0,001). Durante um seguimento médio de 22 meses (IIQ 12­31), 31 pacientes (46%) tiveram recidiva da FA. A análise multivariada produziu dois preditores independentes de recidiva da FA: TAECE (FC 2,05, IC de 95% 1,51­2,79, p<0,001) e FA não paroxística (FC 2,36, IC de 95% 1,08­5,16, p=0,031). CONCLUSÃO: A correlação fraca entre TAE e AE sugere que a fibrose do AE não é o principal mecanismo que liga o TAE e a FA. O TAE mostrou-se mais fortemente associado à recidiva da FA do que à fibrose do AE, corroborando a existência de outros mediadores mais importantes do TAE e da FA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Tecido Adiposo/diagnóstico por imagem , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Feminino , Fibrose , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Recidiva
18.
Int J Cardiovasc Imaging ; 38(1): 225-235, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34390445

RESUMO

The need for permanent pacemaker implantation (PPMI) is a burdensome complication of transcatheter aortic valve implantation (TAVI). The aim of our study was to evaluate different anatomical, clinical, electrocardiographic, and procedural variables associated with the development of conduction abnormalities after TAVI across the entire device spectrum. Single-center prospective cohort of consecutive patients who underwent TAVI since March 2017. Final cohort was studied to detect areas of calcium within aortic valve characterized by leaflet sector and region. Membranous septum (MS) length was assessed throughout a modified coronal view. Device selection and positioning were performed according to the operator criteria. Device selection and positioning were performed according to the operator criteria. From the 273 patients included, 57 underwent PPMI (20.8%). Univariate analysis determined right bundle branch block (RBBB), QRS duration, MS length and calcium within LVOT of non-coronary cuspid as independent predictors. After multivariable logistic regression, both RBBB (OR 6.138; 95% CI 1.23-30.73, P = 0.027) and MS length (OR 0.259; 95% CI 0.164-0.399, P < 0.005) emerged as statistically significant. As a model, they could predict PPMI in 88.7%, independently of which valve used. Youden index analysis yielded 7.69 mm as the optimal cut-off with a negative and positive predictive value of 94.7 and 71.9%, respectively. In our experience, both RBBB pattern and short membranous septum (< 8 mm) were strongly and independently associated with new permanent pacemaker implantation, regardless of the device type. Our findings suggest that this simple evolved measure of MS length may guide device selection and implantation technique and facilitate early discharge.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Rev Port Cardiol (Engl Ed) ; 40(9): 669-675, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34503705

RESUMO

INTRODUCTION: Direct oral anticoagulants (DOACs) changed the landscape of atrial fibrillation (AF) treatment, but also brought with them new challenges in terms of accessibility and compliance. The purpose of this study was to assess adherence to DOACs, and its determinants in a population of AF patients. METHODS: Single-center retrospective study including all patients with non-valvular AF treated with a DOAC from the outpatient general cardiology list at a tertiary center, whose first DOAC prescription was between 1 April 2016 and August 2018. The number of pharmacy refills from the day of first prescription to 31 August 2018 was counted (by means of an electronic prescription platform). Medication refill adherence (MRA) was calculated by dividing the total days' supply by the number of days under therapy. Non-compliance was defined as MRA <90%. RESULTS: A total of 264 patients (120 men, mean age 74 ±â€¯12 years) met the inclusion criteria. The median CHA2DS2VASC score was 3 (interquartile range (IQR) 2-5) and the median HAS-BLED was 1 (IQR 1-2). Rivaroxaban, apixaban, dabigatran and edoxaban were prescribed in 45%, 41%, 24% and 13% of patients, respectively. During the study 51 patients (19%) used at least two DOACs .Patients took DOACs for a median period of 439 days (IQR 269-638), during which the included population adhered to therapy 90% of the time (IQR 75-100%). Half of the patients (51%) were classified as non-compliant; therapy duration (adjusted odds ratio 1.06 per month, 95% confidence interval (CI) 1.03-1.08, p<0.001), DOACs twice daily (adjusted OR 1.73, 95%CI 1.08-2.75, p=0.022), and higher out-of-pocket costs (adjusted OR 2.13, 95%CI 1.28-3.45, p=0.003) were independent predictors of non-compliance. CONCLUSION: Half of the patients (51%) were classified as non-compliant (medication refill adherence <90%). Therapy duration, DOACs twice daily and higher out out-of-pocket costs were independent predictors of non-compliance, which could be targets to improve patient adherence.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Humanos , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA