Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Postepy Kardiol Interwencyjnej ; 20(2): 172-193, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39022700

RESUMO

Introduction: Acute carotid-related stroke (CRS), with its large thrombo-embolic load and large volume of affected brain tissue, poses significant management challenges. First generation (single-layer) carotid stents fail to insulate the athero-thrombotic material; thus they are often non-optimized (increasing thrombosis risk), yet their use is associated with a significant (20-30%) risk of new cerebral embolism. Aim: To evaluate, in a multi-center multi-specialty investigator-initiated study, outcomes of the MicroNET-covered (cell area ≈ 0.02-0.03 mm2) carotid stent (CGuard, InspireMD) in consecutive CRS patients eligible for emergency recanalization. Treatment, other than study device use, was according to center/operator routine. Material and methods: Seventy-five patients (age 40-89 years, 26.7% women) were enrolled in 7 interventional stroke centers. Results: The median Alberta Stroke Program Early CT Score (ASPECTS) was 9 (6-10). Study stent use was 100% (no other stent types implanted); retrograde strategy predominated (69.2%) in tandem lesions. Technical success was 100%. Post-dilatation balloon diameter was 4.0 to 8.0 mm. 89% of patients achieved final modified Thrombolysis in Cerebral Infarction (mTICI) 2b-c/3. Glycoprotein IIb/IIIa inhibitor use as intraarterial (IA) bolus + intravenous (IV) infusion was an independent predictor of symptomatic intracranial hemorrhage (OR = 13.9, 95% CI: 5.1-84.5, p < 0.001). The mortality rate was 9.4% in-hospital and 12.2% at 90 days. Ninety-day mRS0-2 was 74.3%, mRS3-5 13.5%; stent patency was 93.2%. Heparin-limited-to-flush predicted patency loss on univariate (OR = 14.3, 95% CI: 1.5-53.1, p < 0.007) but not on multivariate analysis. Small-diameter balloon/absent post-dilatation was an independent predictor of stent patency loss (OR = 15.2, 95% CI: 5.7-73.2, p < 0.001). Conclusions: This largest to-date study of the MicroNET-covered stent in consecutive CRS patients demonstrated a high acute angiographic success rate, high 90-day patency and favorable clinical outcomes despite variability in procedural strategies and pharmacotherapy (SAFEGUARD-STROKE NCT05195658).

2.
J Clin Med ; 13(6)2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38541959

RESUMO

BACKGROUND: Acute embolic ischemic stroke poses a significant healthcare challenge. Histological clot features' variability among patients with acute ischemic stroke treated by mechanical thrombectomy has potential implications for determining treatment and etiology. This study investigated the clot histological feature differences among patients who experienced cardioembolic stroke and embolic stroke of undetermined source with different left atrial appendage (LAA) morphologies. METHODS: We conducted a prospective observational study involving 79 patients with acute embolic ischemic stroke undergoing mechanical thrombectomy. Computed tomography angiography images were used to classify LAA morphologies. An artificial intelligence algorithm assessed the clot fibrin and red blood cell contents. RESULTS: Patients with chicken-wing LAA morphology exhibited lower mean clot fibrin proportions than did those with non-chicken-wing morphology (p < 0.001). Linear regression analysis showed that chicken-wing LAA was significantly associated with a lower clot fibrin proportion (estimate, -0.177; 95% CI [-0.259, -0.096]; p < 0.001). The successful recanalization rate and first-pass effect between the groups did not differ significantly. CONCLUSIONS: The chicken-wing LAA morphological type is associated with lower clot fibrin contents, suggesting potentially different embolism mechanisms or diverse embolic sources, compared with the non-chicken-wing LAA types. Further studies are required to investigate this association.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA