Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur J Med Res ; 23(1): 14, 2018 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-29506581

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation (TAVI) remains an issue open for criticism. Aim of this study is to investigate a strategy to reduce PPMI rate after TAVI in general and more specifically after implantation of the LOTUS® prosthesis. METHODS: Through our learning curve, we have developed a structured protocol to reduce PPMI rate. The protocol includes: shallow implantation depth within the native annulus, strict adherence to the international guidelines for PPMI, PPMI not earlier than 5 days after TAVI, and intravenous chronotropic and steroidal treatment (orciprenaline 0.6-1.7 mg/h i.v. and dexamethasone 25 mg/day i.v. for a maximum of 5 days) in case of acute onset of intraventricular and/or atrio-ventricular conduction disturbances after TAVI. RESULTS: The first 35 patients (group A) were managed as per routine in our early stage experience with the LOTUS valve. The PPMI reduction protocol was applied in the second phase on the last 31 patients (group B). The PPMI rate was reduced from 34.3% (12/35) to 9.7% (3/31) (p = 0.02). At logistic regression analysis being treated in the second phase of our experience (group B) had a protective effect against PPMI (p = 0.05; OR = 0.1; CI = 0.01-1.0). Prosthesis implantation depth was directly related to PPMI (p = 0.005; OR = 2.0; CI = 1.2-3.2). Receiver operating characteristic curve analysis confirmed that a LOTUS implantation depth > 4.8 mm was the cut-off to predict PPMI (AUC = 0.8; p = 0.003; CI = 0.6-0.9) with maximal sensitivity (78.6%) and specificity (73.2%). CONCLUSIONS: PPMI rate after LOTUS can be reduced with experience by applying specific clinical and operative strategies.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 89(1): 135-142, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27739165

RESUMO

OBJECTIVES: We present our single center experience with the direct flow medical (DFM) prosthesis addressing the impact of native aortic valve (AV) calcification degree on outcomes. BACKGROUND: The DFM® has been introduced for transcatheter aortic valve implantation (TAVI). The valve has a nonmetallic and inflatable support structure. METHODS: Patients were divided in two groups according to preoperative cardiac computed tomography (CT): group I moderate calcification and group II heavy calcification of the total AV area. We evaluated 118 patients: 53 (45%) group I and 65 (55%) group II. RESULTS: Preoperative trans-AV gradient and calcification extension across the aortic unit were significantly higher in group II (P = 0.008 and P < 0.0001). CT perimeter derived annular diameter (group I 24.7 ± 2.1 mm vs. group II 24.8 ± 1.9; P = 0.6) and implanted prosthesis size (group I 26.1 ± 1.5 mm vs. group II 25.7 ± 1.5; P = 0.1) were similar. Hemodynamics were similar: mean gradient 16.1 ± 5.9 mm Hg (group I) vs. 17.3 ± 6.5 mm Hg (group II) (P = 0.3). Total aortic regurgitation (AR) was mild in 5.7% in group I and 20% in group II (P = 0.03). None developed moderate/severe AR. Heavy AV calcification was the sole independent determinant for mild regurgitation (P = 0.02; OR = 7; 95% CI: 1.2-37.6). Follow-up (289 days; 40-760 days) estimated survival was 88.1% (group I) and 93.8% (group II) (P = 0.3). CONCLUSIONS: Independent of AV calcification degree, adequate sizing and implantation can be achieved with the DFM®. Although higher burden of calcification increases the rate of mild AR, no patient developed moderate and severe AR. Short-term estimated survival was not influenced by calcification degree. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Bioprótese , Calcinose/terapia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Ecocardiografia , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 89(3): 420-428, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27739170

RESUMO

OBJECTIVES: To analyze our single center experience with the Direct Flow Medical (DFM). BACKGROUND: The DFM has been recently introduced to the market and large real world experiences are lacking. METHODS: A total of 126 patients with severe aortic valve stenosis (AVS) were treated by the same team from March 2013 to May 2015. Device success and procedural safety were classified, according to valve academic research consortium (VARC) criteria, for the entire cohort, including patients treated in the early phases of our learning curve. RESULTS: Clinical and trans-thoracic echocardiography follow-up was performed (median duration 279 days; 36-761 days). Mean age was 80.9 ± 5.5 years and median logistic Euro-SCORE was 15.9 (5.5-84.2). Cardiovascular 30-day mortality was 4.8% (6/126), device success 89.6% (113/126), and early safety 85.7% (108/126). At discharge, no aortic regurgitation (AR) was present in 85.7% and mild AR in 14.3% of the patients. Estimated 1-year follow-up survival was 91%. At follow-up, no AR was present in 87.3%, mild AR in 10.9%, and moderate AR in 1.8%. Mean gradient of 15.1 ± 6.3 mm Hg and prosthesis effective orifice area of 1.6 ± 0.6 cm2 were reported. CONCLUSIONS: In this single center experience, the DFM valve showed satisfactory clinical and hemodynamic results. Short-term follow-up confirmed the consistent clinical results, with low rates of AR and acceptable trans-prosthetic gradients and prosthetic effective orifice area. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Ecocardiografia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Curva de Aprendizado , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
4.
Int J Cardiol ; 220: 909-13, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27404506

RESUMO

BACKGROUND: Second-generation TAVI prostheses may enhance the procedure reducing operative time and complications rate, maintaining adequate valve hemodynamic performance. We present our results with 2 new generation trans-catheter aortic valve (TAVI) prostheses in obese patients. METHODS: A series of 172 patients underwent trans-femoral TAVI with new generation prostheses (Direct Flow Medical, DFM®, and LOTUS®). Two groups were identified according to body mass index (BMI): group NO (125) BMI<30kg/m(2) and group O (47) BMI≥30kg/m(2). RESULTS: Trans-femoral approach was possible in all patients without conversion to conventional surgery/cardiopulmonary bypass. Operative/fluoroscopy time and contrast use were comparable. Vascular and bleeding complications were also equally represented in the 2 groups. Thirty-day mortality was 7.2% in group NO and 6.4% in group O (p=0.9). At discharge, aortic regurgitation was absent/mild in 96% of group NO and in all patients in group O (p=0.3). Mild prosthetic stenosis was reported in 3.8% of the patients in group NO and 2.2% in group O. No moderate/severe prosthetic stenosis was reported. Estimated 1-year survival was 93.1% in group NO and 83.2% in group O (p=0.6). Estimated 1-year freedom from MACCE was 74.7% in group NO and 62.8% in group O (p=0.4). At follow-up echocardiography no significant differences were noticed in the 2 groups. CONCLUSIONS: Second generation TAVI prostheses allow for safe and effective procedures in obese patients. In spite of patient's body habitus, agile prosthesis placement will lead to optimized hemodynamics. Valve and clinical performance are confirmed at follow-up.


Assuntos
Hemodinâmica/fisiologia , Obesidade/cirurgia , Desenho de Prótese/instrumentação , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Obesidade/diagnóstico por imagem , Obesidade/fisiopatologia , Estudos Prospectivos , Desenho de Prótese/métodos , Substituição da Valva Aórtica Transcateter/métodos
5.
Catheter Cardiovasc Interv ; 87(3): 500-7, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26013307

RESUMO

OBJECTIVES: We present our experience with an inflatable, non-metallic, fully retrievable, and repositionable transcatheter aortic valve [Direct Flow® Medical (DFM)] focusing on technical features adopted during implantation. BACKGROUND: Implantation techniques of new generation percutaneous aortic valves are still developing and with experience implementations are described. METHODS: The "low pressure" (initial valve inflation at 4 ATM, lower than the recommended 12 ATM) and the "alternate aortic curve" techniques (initial valve pulling either from the wire running on the side of the inner or from the one on the outer aortic curve) are part of our modified protocol for DFM® implantation. RESULTS: Forty-two consecutive patients underwent TAVI with DFM. The "low pressure" technique was used in all patients. In 27 (64.3%) patients the bulkiest calcifications were on the inner aortic curve side, and an inner curve technique was used to initiate valve pulling toward the annular hinge point. In the remaining 15 (35.7%) patients, an outer curve technique was used. Neither pull-through nor re-valving was reported. Valve performance showed mean gradient of 8.9 mm Hg. Mild paravalvular leak was reported in seven (16%) patients. No one experienced moderate or severe aortic insufficiency. Thirty-day mortality was 9.5% (4/42). CONCLUSION: The "low pressure technique" and the "alternate curve technique" guarantee an anatomy and patient tailored approach to achieve controlled and finely tuned valve seating.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Valvuloplastia com Balão , Calcinose/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Aortografia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pressão , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
6.
EuroIntervention ; 11 Suppl W: W49-52, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26384190

RESUMO

Secondary mitral regurgitation (MR) has a complex pathophysiology that includes global or segmental left ventricular (LV) motion abnormalities (of non-ischaemic or ischaemic origin) leading to impaired leaflet coaptation of a normally structured mitral valve (MV). In this context, the LV functional and geometrical changes result in MV leaflet tethering, MV annulus flattening and the decrement of systolic MV closing forces. In light of its complexity, management of secondary MR remains a challenge. In fact, a long-lasting successful treatment using a single medical device and/or intervention that addresses solely the MV target cannot, at least at the present time, be proposed.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/terapia , Valva Mitral , Disfunção Ventricular Esquerda/terapia , Algoritmos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Procedimentos Clínicos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Seleção de Pacientes , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA