Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int Orthop ; 36(8): 1701-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22729663

RESUMO

PURPOSE: The aim of this study was to evaluate the safety and efficiency, as well as the incorporation characteristics of a specific type of xenograft used for iliac crest defects post-harvesting tri-cortical iliac crest bone graft. METHODS: Sixteen patients diagnosed with chronic anterior pelvic pain were operated for pubic symphysis fusion. The tri-cortical graft harvested from the iliac crest was inserted into the pubic symphysis and compressed with a reconstruction plate. The defect in the iliac crest was filled with a block of cancellous bovine substitute (Tutobone®). The length of iliac crest defect, time to fusion of pubic symphysis, time to incorporation of the graft and complications were recorded. The postoperative pain and patients' satisfaction were evaluated. RESULTS: The median age of patients was 36.5 years (range 27-75). Fusion was obtained in 15 patients (94 %). The median time to fusion was four months (range three to seven). The length of the iliac crest bone defect ranged from 40 to 70 mm. Integration of the bovine substitute was achieved in 15 patients (94 %) over a median period of three months (range two to six). The postoperative median pain score was 2 (range 1-5). Twelve patients (75 %) reported good satisfaction. No major complications or allergic reactions were observed. CONCLUSIONS: The xenograft used in this study provided a safe and effective method of reconstruction of iliac crest donor site defects. It has satisfactory incorporation, high biocompatibility and no signs of inflammatory reactions. This new technique is simple and easily reproducible in routine clinical practice.


Assuntos
Artrodese/métodos , Transplante Ósseo/métodos , Ílio/cirurgia , Sínfise Pubiana/cirurgia , Transplante Heterólogo/métodos , Adulto , Idoso , Animais , Artrodese/efeitos adversos , Transplante Ósseo/efeitos adversos , Bovinos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/diagnóstico por imagem , Satisfação do Paciente , Sínfise Pubiana/diagnóstico por imagem , Radiografia , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Transplante Heterólogo/efeitos adversos , Resultado do Tratamento
2.
J Trauma Acute Care Surg ; 72(2): E81-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22439240

RESUMO

BACKGROUND: Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. METHODS: Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. RESULTS: Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. CONCLUSIONS: Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Adolescente , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas da Tíbia/classificação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA