Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Medicina (Kaunas) ; 60(10)2024 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-39459507

RESUMO

Background and Objectives: Robotic-assisted total knee arthroplasty (TKA) is gaining popularity worldwide, leading to a potential increase in the number of pin tracker-related complications. This study determined the effectiveness of periarticular pin tracker placement in the distal femur and proximal tibia through a single main incision during robotic-assisted TKA over a minimum follow-up period of 6 months. Materials and Methods: A consecutive series of 149 TKAs was performed in 108 patients using the triathlon posterior-stabilized total knee prosthesis with a robotic-assisted system at our hospital from December 2023 to February 2024. Clinical outcomes and complications associated with pin tracker sites, including pin-site infection, neurovascular injury, hematoma, soft-tissue morbidity, and pin-site fracture, were assessed. Results: The mean Knee Society knee score improved from 42.5 preoperatively to 76.3 points at the final follow-up, whereas the mean Knee Society function score improved from 43.1 preoperatively to 78.1 points at the final follow-up (both p < 0.05). No patient experienced any minor or major complications related to the use of pin trackers in the distal femur and proximal tibia. Conclusions: This periarticular technique that uses pin trackers in the distal femur and proximal tibia through a single main incision could be a useful option for orthopedic surgeons while performing robotic-assisted TKA.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/efeitos adversos , Feminino , Masculino , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Resultado do Tratamento , Pinos Ortopédicos , Fêmur/cirurgia , Estudos Retrospectivos , Tíbia/cirurgia
2.
J Pers Med ; 14(9)2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39338196

RESUMO

Bone marrow aspirate concentrate (BMAC) has been increasingly used as an injectable treatment for knee osteoarthritis (OA). However, there remains a lack of studies on the pain and complications associated with BMAC treatment. This study compared the pain and complications of BMAC treatment between outpatients and inpatients with Kellgren-Lawrence grade II-III knee osteoarthritis (OA) during a follow-up period of ≥3 months. This study included 40 outpatients (40 knees) and 80 inpatients (80 knees) as controls who received BMAC articular injections for knee OA between December 2023 and March 2024. Outpatients were administered BMAC under local anesthesia alone, whereas inpatients were administered BMAC under local anesthesia and intravenous anesthesia. The outcomes were the visual analog scale (VAS) pain score during the BMAC procedure and the complications associated with harvest and injection sites. The mean VAS pain score in the outpatient group was significantly higher than that in the inpatient group during trocar insertion (5.2 vs. 1.3, p < 0.05) and bone marrow aspiration (6.2 vs. 1.4, p < 0.05), but it was similar between the two groups during BMAC injection (2.2 vs. 2.3, p = 0.858). Transient post-treatment complications were observed in 17.5% (7/40) of outpatients and 16.3% (13/80) of inpatients. No significant differences were observed in complications between the two groups, all of which were resolved within 2 months without any specific problem. Moreover, no major complications occurred in any group. In conclusion, outpatients who received only local anesthesia reported significant pain during BMAC treatment. The addition of intravenous anesthesia is necessary to alleviate pain during the BMAC procedure.

3.
J Pers Med ; 14(9)2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39338199

RESUMO

This study reports 12 cases of inaccurate bone cutting from a single-surgeon series of 509 consecutively performed robotic-assisted total knee arthroplasty (TKA) for 1 year. In addition, a complementary technique with the combined benefits of robotic-assisted and manual techniques that address this issue is described. From June 2020 to May 2021, a consecutive series of 509 TKAs was performed on 338 patients using a posterior-stabilized total knee prosthesis with a robotic-assisted system at our hospital. The surgical records were reviewed to identify the causative bone locations and bone re-cutting events correlated with improper trial instrument positioning. The re-cutting rate was 2.4% (12/509). All re-cutting attempts occurred because of improper cutting of the femoral posterior chamfer. Re-cutting was attempted mostly on middle-aged male patients. This complementary technique can facilitate manual bone cutting while retaining the advantages of robotic surgery during robotic-assisted TKA. Additionally, the combined technique of manual bone cutting and robotic-assisted surgery can be a useful alternative for middle-aged male patients with rigid knee bones.

4.
Medicina (Kaunas) ; 60(7)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-39064470

RESUMO

Background and Objectives: The term "Juxtafacet cyst" refers to both synovial cysts and ganglion pseudocysts associated with the lumbar facet joint. As conservative treatment for the juxtafacet cyst has a minimal effect, complete excision through surgery is considered the first choice of treatment. In this study, we retrospectively reviewed the clinical outcomes of percutaneous epidural neuroplasty for symptomatic lumbar juxtafacet cysts. Materials and Methods: We conducted a retrospective review of 34 patients with symptomatic juxtafacet cysts who visited a single institute from January 2010 to September 2023. Patients who received conservative treatment for at least 6 weeks but experienced no or insufficient effects were eligible for this study. After neuroplasty, a medical history check and neurological examination were performed during follow-up at 2 weeks, 1 month, 2 months, 3 months, 6 months, and once a year thereafter. Results: The pain improved for all patients to a VAS score of 3 or less immediately after neuroplasty; however, four of those patients (11%) had pain that worsened eventually to the same level as before the procedure and required surgery. The results showed that, regardless of cyst size, in cases with severe stenosis of the spinal canal, the outcome of neuroplasty was poor and often eventually required surgery. The cyst size was not associated with the procedure results. In addition, if the cyst was present at the L4-L5 level, or if diabetes mellitus was present, the likelihood of future surgery was significant (p-value = 0.003). Conclusions: Percutaneous neuroplasty showed a better success rate than other non-surgical treatments. In addition, severe spinal stenosis (Schizas grade C or higher), L4-L5 level, or diabetes mellitus produced a high possibility of surgery due to recurrence.


Assuntos
Vértebras Lombares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Vértebras Lombares/cirurgia , Adulto , Resultado do Tratamento , Cisto Sinovial/cirurgia , Cisto Sinovial/complicações , Articulação Zigapofisária/cirurgia , Região Lombossacral/cirurgia
5.
Medicina (Kaunas) ; 60(6)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38929594

RESUMO

This study aimed to identify the effectiveness and potential complications on the harvest site and knee of bone marrow aspirate concentrate (BMAC) treatment of patients with Kellgren-Lawrence (K-L) grades II-III knee osteoarthritis (OA) over a minimum follow-up period of 6 months. This study retrospectively evaluated data from 231 patients (285 knees) with knee OA treated with BMAC articular injection at a single center from August 2023 to October 2023. The inclusion criteria were a longstanding knee pain unresponsive to conservative treatments for at least 6 weeks with K-L grades II-III OA. The exclusion criteria were age of <40 years or >80 years, previous knee surgery, rheumatological or other systemic disease, malignancy, uncontrolled diabetes mellitus, or infections. Bone marrow was aspirated from the anterior iliac crest and concentrated by the single-spin centrifugation technique. The visual analog scale (VAS) pain score and Knee Society Score were used to evaluate the clinical outcomes and complications associated with harvest and injection sites were evaluated. The mean follow-up period was 7.2 months (range: 6-8 months). The pretreatment VAS pain score decreased from 4.3 to 0.4 points at the final follow-up (p < 0.05). Pretreatment Knee Society knee and function scores were improved from 86.9 to 98.1 (p < 0.05) and from 68.4 to 83.3 points (p < 0.05), respectively. A total of 15 complications (5.3%, 15/285) were observed, including 3 hematomas, 2 numbness, 2 contact dermatitis, and 1 superficial infection in the harvest site and 4 mild and moderate swelling and 3 severe swelling and pain in the injection site. BMAC is a reliable and effective treatment for patients with K-L grades II-III knee OA, but the orthopedic surgeon should consider that bleeding tendency by heparin causes severe joint swelling and pain after intra-articular knee injection.


Assuntos
Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Adulto , Medição da Dor , Transplante de Medula Óssea/métodos , Transplante de Medula Óssea/efeitos adversos , Injeções Intra-Articulares , Idoso de 80 Anos ou mais
6.
Medicine (Baltimore) ; 103(19): e38168, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728455

RESUMO

BACKGROUND: Supplementation with leucine-enriched essential amino acids (LEAAs) has shown efficacy in the recovery of muscle injury and activation of muscle synthesis. Muscle function in knee osteoarthritis is a crucial factor for managing pain and preserving ambulatory function. However, the efficacy and safety of LEAAs supplementation in patients with knee osteoarthritis have not been evaluated. METHODS: In this prospective analysis, we evaluated the efficacy and safety of supplementation with 12 g of LEAAs daily for 8 weeks in knee-symptomatic osteoarthritis patients. For assessing the efficacy, clinical pain, calf circumference, and disability were assessed using questionnaires (visual analog scale, Knee Society Score, and 36-item short form survey [SF-36]), laboratory analyses (total protein and albumin), and radiologic study (dual-energy X-ray absorptiometry [DEXA]) for muscle and bone density. To evaluate safety, generalized or localized protein allergic reactions, complete blood count, liver and kidney function, and serum glucose were measured. RESULTS: Sixty-five participants, categorized into the experimental (n = 32) and control (n = 33) groups, were included in this 8-week trial from March 2022 to July 2022. A significantly higher efficacy was observed in the experimental group than in the control group, as indicated by muscle density in the DEXA scan (P = .001) and SF-36 (P < .001). The safety evaluation revealed no related generalized or local protein allergy. Hematological findings, serum glucose, and kidney and liver toxicity were not significantly different between the groups. CONCLUSION: Supplementation with leucine-enriched proteins is safe and efficacious in the improvement of muscle density and quality of life.


Assuntos
Aminoácidos Essenciais , Suplementos Nutricionais , Leucina , Osteoartrite do Joelho , Humanos , Feminino , Osteoartrite do Joelho/tratamento farmacológico , Leucina/uso terapêutico , Leucina/administração & dosagem , Masculino , Pessoa de Meia-Idade , Aminoácidos Essenciais/uso terapêutico , Aminoácidos Essenciais/administração & dosagem , Estudos Prospectivos , Idoso , Resultado do Tratamento , Medição da Dor
7.
Arch Orthop Trauma Surg ; 143(9): 5807-5813, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36720735

RESUMO

PURPOSE: The purpose of this study was to assess tibial post fracture between highly cross-linked polyethylene (HXPE) and conventional polyethylene inserts in consecutive posterior-stabilized (PS) total knee arthroplasty (TKA) over a minimum 10-years follow-up period. METHODS: Between July 2008 and December 2011, a consecutive series of 3264 primary TKAs was performed in 2098 patients using a PS total knee prosthesis at a single institution. The final cohort was classified into the HXPE group (792 cases) and the conventional group (2113 cases) according to insert material used during the procedure. RESULTS: The mean follow-up period was 11.4 years in the HXPE group and 11.8 years in the conventional group. Both cases of tibial post fracture occurred in the HXPE group, a complication rate of 0.25%. These two cases required replacement with a thicker tibial insert with retention of the femoral and tibial components. There were no cases of tibial post fracture in the conventional group. CONCLUSION: There was no difference in tibial post fracture rate between the HXPE group and the conventional group in PS TKA on long-term follow-up. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Fraturas da Tíbia , Humanos , Polietileno , Articulação do Joelho/cirurgia , Seguimentos , Desenho de Prótese , Prótese do Joelho/efeitos adversos , Fraturas da Tíbia/cirurgia , Falha de Prótese
8.
J Knee Surg ; 36(10): 1102-1104, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35817054

RESUMO

The purpose of this study was to determine the outcomes of the placement of a pin tracker in the distal femur in robotic-assisted total knee arthroplasty (TKA) over a minimum follow-up period of 1 year. A consecutive series of 81 TKAs were performed in 59 patients using a robotic-assisted system (Mako) at our hospital. The mean follow-up period was 1.1 years (range, 1-1.2 years). No periprosthetic fracture at a pin tracker site was reported at a minimum of 1 year of follow-up. No patients reported minor or major complications associated with the distal femoral pins. In addition, unicortical pin-site drilling marks in all patients disappeared on one-postoperative-year follow-up radiographs. Our technique, which used unicortical pin placement in the distal femur in robotic-assisted TKA, demonstrated that it was a safe and reliable method at a minimum follow-up period of 1 year. The level of evidence is IV.


Assuntos
Artroplastia do Joelho , Fraturas do Fêmur , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Seguimentos , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Articulação do Joelho/cirurgia
9.
J Knee Surg ; 36(4): 435-438, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34507358

RESUMO

The purpose of this study was to determine the effectiveness of the placement of pin trackers in the medial sagittal plane of the distal femur in robotic-assisted total knee arthroplasty (TKA) over a minimum follow-up period of 3 months. From August 2020 to October 2020, a consecutive series of 81 TKAs were performed in 59 patients using the Triathlon posterior-stabilized total knee prosthesis with a robotic-assisted system (Mako) at our hospital. Patient charts were reviewed for complications associated with the pin sites, including fracture, infection, thigh pain, and the need for reoperation. No patients had any minor or major complications associated with distal femoral pins. This technique, which used pin trackers in the medial sagittal plane of the distal femur, could be a useful option for surgeons performing robotic-assisted TKA. This is a Level IV study.


Assuntos
Artroplastia do Joelho , Fraturas do Fêmur , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/efeitos adversos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Cirurgia Assistida por Computador/métodos , Fêmur/cirurgia , Prótese do Joelho/efeitos adversos , Fraturas do Fêmur/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia
10.
J Orthop Sci ; 28(5): 1068-1073, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36075842

RESUMO

BACKGROUND: This study compared the functional outcomes, implant survival rates, and complications of total knee arthroplasty (TKA) performed in patients with windswept deformity (WSD) and non-WSD patients over at least 10 years of follow-up. METHODS: From January 2008 to December 2010, 40 TKAs were performed in 20 patients with WSD (WSD group). Additionally, 60 propensity score-matched patients without WSD who had undergone primary bilateral TKA were chosen for the control group in a three-to-one ratio. Then, the functional outcomes, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 10.8 years in the WSD group and 11.5 years in the control group. RESULTS: The mean Knee Society knee scores in the WSD and control groups improved from 37.7 to 38.1 points preoperatively to 79.5 and 79.2 points at final follow-up (p = 0.974), while the mean function scores in the WSD and control groups improved from 36.5 to 37.2 points preoperatively to 77.8 and 77.4 points at final follow-up (p = 0.863). Two knees in the WSD group required revision surgery, including one due to septic loosening and one due to aseptic loosening. Five knees in the control group required revision surgery, including three due to septic loosening and two due to aseptic loosening. Kaplan-Meier survivorship analysis with the revision of either component as an endpoint in the WSD and control groups estimated 95.0% and 95.8% chances of survival for 10 years, respectively (p = 0.824). CONCLUSIONS: TKA performed in patients with WSD yielded good clinical outcomes and survivorship at least 10 years later. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Resultado do Tratamento , Falha de Prótese , Articulação do Joelho/cirurgia , Reoperação , Seguimentos , Estudos Retrospectivos
11.
Clin Case Rep ; 10(12): e6773, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36545561

RESUMO

The cause of early aseptic loosening in total knee arthroplasty (TKA) is uncertain, although several possibilities could be offered. We report that osteonecrosis of the knee should be considered as a possible cause or contributing etiologic factor for early aseptic loosening following primary TKA.

12.
Orthop Res Rev ; 14: 445-451, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36444241

RESUMO

Background: Achieving proper axis alignment can be difficult in the presence of posttraumatic extra-articular deformities in either the femur or the tibia. We present radiological outcomes following robot-assisted total knee arthroplasty (TKA) in patients with osteoarthritis of the knee accompanied by posttraumatic extra-articular deformities. Methods: We analyzed the outcomes of five knees in five patients with (1) Kellgren-Lawrence (K-L) Grade III-IV osteoarthritic knees, (2) the presence of posttraumatic extra-articular deformities either in the femur or the tibia, and (3) who underwent robot-assisted TKA. Their radiological findings were evaluated. Results: All five knees with initial deformity (mean 14.8°, range 12.7-18.5°) were corrected to neutral alignment (mean 0.7°, range -1.1-2.7°). There was no postoperative outlier of hip-knee-ankle (HKA) angle. Conclusion: Our results indicate that robot-assisted TKA can be used to achieve proper limb alignment in patients with posttraumatic extra-articular deformities.

13.
J Exp Orthop ; 9(1): 108, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36302997

RESUMO

PURPOSE: The purpose of this study was to compare the mechanical axis, accuracy of component positioning, and polyethylene liner thickness between robot-assisted total knee arthroplasty (TKA) and conventional TKA. METHODS: From July 2020 to December 2020, 154 TKAs were performed in 110 patients with Kellgren-Lawrence grade IV varus knees using a robot-assisted system (MAKO group). Additionally, 110 propensity score-matched patients who had undergone primary conventional TKA were chosen in a one-to-one ratio for the conventional group. Post-operative radiographs were used to evaluate mechanical axis and component coronal and sagittal positioning. The polyethylene liner thickness was investigated. The respective mean error values and outliers were obtained for the two study groups and were compared to determine the mechanical axis and the accuracy of the postoperative component positioning. RESULTS: Patients in the MAKO group achieved better accuracy than those in the conventional group in terms of postoperative mean mechanical axis (1.9˚ vs. 2.8˚, p < 0.05), femur coronal inclination (91.2˚ vs. 91.8˚, p < 0.05), tibia coronal inclination (90.8˚ vs. 91.1˚, p < 0.05), and tibia sagittal inclination (90.7˚ vs. 91.7˚, p < 0.05). However, there was no difference between the two groups in polyethylene liner thickness. CONCLUSIONS: Robot-assisted TKA showed improved mechanical axis and higher accuracy of component positioning compared to the conventional TKA technique, with no significant difference in polyethylene liner thickness between the two groups. Long-term follow-up studies are needed to compare the clinical outcomes of robot-assisted TKA. LEVEL OF EVIDENCE: IV.

14.
Orthop Res Rev ; 14: 199-206, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35707697

RESUMO

Purpose: The purpose of this study was to assess the medium-term results of trabecular metal cones for the reconstruction of large bone defects in revision TKA. Methods: Thirteen patients who had undergone revision TKA using trabecular metal cones for femoral and/or tibial large bone defects were identified. We included patients who had a minimum of three years follow-up in the study. We evaluated their functional outcomes, implant survivorship, radiological findings, and complications. Results: At a mean follow-up of 6.9 years (range of 3.5-9.4 years), all trabecular metal cones and implants were well fixed and did not exhibit any radiographic evidence of migration or loosening. At the final follow-up, the mean Knee Society knee scores had improved from 37.2 to 78.1 (p < 0.05), and function scores had improved from 35.5 to 77.5 points (p < 0.05). One intraoperative fracture in the distal femur occurred in an 85-year-old woman during impaction of a single trabecular metal cone. The fracture was successfully affixed to the femoral cone and bone three months postoperatively. Conclusion: The present study of trabecular metal cones demonstrates excellent clinical outcomes and survivorship in revision TKA during medium-term follow-up periods. However, longer-term follow-up studies are needed to further investigate these implants in revision TKA. Additionally, the necessity of metal cones in revision procedures should be carefully considered depending on patient needs and economic capabilities.

15.
Clin Case Rep ; 10(3): e05574, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35317063

RESUMO

Arthroscopic saucerization of the lateral discoid meniscus is considered due to an increase in the load of the lateral compartment after high tibial osteotomy (HTO). We report a case of lateral discoid meniscus regeneration after arthroscopic saucerization in a middle-aged female patient who underwent HTO.

16.
Clin Case Rep ; 10(2): e05366, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35223003

RESUMO

Total knee arthroplasty (TKA) is technically demanding in patients with pre-existing hardware around the knee. We report two cases of knee osteoarthritis in patients with retained hardware who would have difficulty undergoing conventional TKA. Robot-assisted TKA can be a useful treatment for knee osteoarthritis in patients with retained hardware.

17.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2786-2792, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34286348

RESUMO

PURPOSE: The purpose of this study was to compare the functional outcomes, activity levels, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with rheumatoid arthritis (RA) with those in patients with osteoarthritis (OA) over a minimum 10-year follow-up period. METHODS: Between January 2007 and December 2009, 90 TKAs performed in 57 patients with RA (RA group) were retrospectively reviewed and matched with a control group of 180 TKAs performed in 114 patients with OA. The functional outcomes (Knee Society Score), activity levels (Koval grade), mortalities, implant survival rates, and complications were compared between the two groups with a minimum 10-year follow-up period. The mean follow-up periods were 12.3 years in the RA group and 12.6 years in the OA group. RESULTS: The mean Knee Society knee scores in the RA and OA groups improved from 37.7 ± 5.4 to 38.2 ± 5.3 preoperatively to 72.9 ± 22.8 to 83.1 ± 11.0 points, respectively, at the final follow-up (p < 0.05). At the final follow-up, 38 of 48 (79.2%) in the RA group and 105 of 109 (96.3%) in the OA group (p < 0.05) were outdoor ambulatory patients. The cumulative mortality rates in the RA and OA groups were 15.8% (9/57) and 4.4% (5/114) (p < 0.05) at the final follow-up, respectively. Kaplan-Meier survivorship analysis with revision of either component as an endpoint in the RA and OA groups estimated 94.4% and 98.3% chance of survival for 10 years, respectively. CONCLUSION: TKA in patients with RA had worse functional outcomes and higher mortality over a minimum 10-year follow-up period, compared with TKA in patients with OA. LEVEL OF EVIDENCE: IV.


Assuntos
Artrite Reumatoide , Artroplastia do Joelho , Osteoartrite do Joelho , Artrite Reumatoide/complicações , Artrite Reumatoide/cirurgia , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
18.
Clin Case Rep ; 9(11): e05087, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34804535

RESUMO

We report a rare case of traumatic anterior dislocation in a patient with postoperative delirium following total knee arthroplasty. The patient was successfully treated by open reduction of the dislocation and polyethylene liner change. Recognition of risk factors for postoperative delirium is important for the prevention of this uncommon injury.

19.
J Orthop Surg Res ; 16(1): 624, 2021 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-34663401

RESUMO

BACKGROUND: The purpose of this study was to compare the functional outcomes, activity levels, mortalities, implant survival rates, and complications in revision total knee arthroplasty (TKA) of patients with septic loosening with those in patients with aseptic loosening over a minimum 10-year follow-up period. METHODS: A cohort of 78 patients (36 septic loosening and 42 aseptic loosening) was selected between January 2008 and December 2009. The functional outcomes, activity levels, mortalities, implant survival rates, and complications of revision TKA in patients with septic and aseptic loosening were compared. RESULTS: The mean Knee Society knee scores in the septic and aseptic groups improved from 36.7 and 37.4 preoperatively to 65.3 and 76.8 points at the final follow-up, respectively (p < 0.05). Outdoor ambulatory patients at the final follow-up included 20 of 29 (69.0%) patients in the septic group and 35 of 39 (89.7%) patients in the aseptic group (p < 0.05). The cumulative mortality rates in the septic and aseptic groups were 19.4% (7/36) and 7.1% (3/42) (p = 0.102) at final follow-up, respectively. Kaplan-Meier survivorship analysis with re-revision of either component as an endpoint in the septic and aseptic groups estimated 86.5% and 95.5% chance of survival for 10 years, respectively. CONCLUSIONS: Revision TKA in patients with septic loosening had worse functional outcomes and higher mortality over a minimum 10-year follow-up period compared with that in patients with aseptic loosening. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
20.
Case Rep Orthop ; 2021: 5245396, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34608422

RESUMO

Multiple risk factors such as age, body mass index (BMI), preoperative diagnosis, smoking, diabetes mellitus, malalignment of an implant, and presence of ipsilateral hindfoot fusion have been shown to contribute to failure of total ankle arthroplasty (TAA). However, the exact causes of TAA failure remain uncertain, and various causes can lead to a need for revision surgery. We report a case of early aseptic loosening of the implant following TAA in a patient with severe varus deformity of the ipsilateral knee.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA