Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Clin Endosc ; 2024 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-39385518

RESUMO

Background/Aims: The efficacy and safety of endoscopic submucosal dissection using a clutch cutter (ESD-CC) for subepithelial lesions within the esophagogastric submucosa (SELEGSM) has not been investigated. This study aimed to assess the efficacy and safety of ESD-CC for the treatment of SELEGSM. Methods: This prospective study included 15 consecutive patients with 18 SELEGSMs diagnosed by endoscopic ultrasonography. The primary outcomes were short-term outcomes including en bloc resection rate, R0 resection rate, procedure time, and complication rate. The secondary outcome was final histological diagnosis. Results: Among the participants, 18 lesions were identified: 12 in the stomach (nine patients) and six in the esophagus (six patients). The en bloc resection rate was 94.4% (17/18). The R0 resection rate was 88.9% (16/18). The median operating time was 39 min, and no instances of perforation or bleeding were observed. The final diagnoses of SELEGSM included six neuroendocrine tumors (33.3%), six granular cell tumors (33.3%), two ectopic pancreases (11.1%), one inflammatory fibroid polyp (5.6%), one leiomyoma (5.6%), one lipoma (5.6%), and one leiomyosarcoma (5.6%). Conclusions: ESD-CC appears to be a technically efficient and safe approach for SELEGSM resection, suggesting its potential as a valuable treatment option.

2.
Australas J Ultrasound Med ; 27(2): 89-96, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38784701

RESUMO

Introduction/Purpose: For gastric subepithelial lesions (GSELs) showing a hypoechoic mass (HM) on endoscopic ultrasonography (EUS) imaging, the utility of EUS-guided tissue acquisition using conventional fine-needle aspiration needles (EUS-TA-CFNAN) and the frequency of histological types remain unclear. This study aimed to examine this issue. Methods: This prospective observational study enrolled 291 consecutive patients who underwent EUS-TA-CFNAN for GSELs showing an HM (GSELHM) on EUS imaging. Immunohistochemical analysis was performed for all EUS-TA-CFNAN and surgically resected specimens. The main outcome measures were the technical results of EUS-TA-CFNAN and the frequency of histological types in GSELHM. Results: The endoscopic ultrasound-guided tissue acquisition using conventional fine-needle aspiration needle diagnosis rate for GSELHM was 80.1% (95% confidence interval [CI]: 75.0-84.5, 233/291). It was significantly lower for antrum (P = 0.004) and lesions smaller than 2 cm (P = 0.003). There were no adverse events. The immunohistochemical diagnoses of EUS-TA-CFNAN included 149 cases of gastrointestinal stromal tumour (GIST) (51.2%), 48 cases of leiomyoma (16.5%), 11 cases of schwannoma (3.8%), 8 cases of the ectopic pancreas (2.7%), 5 cases of subepithelial lesion like cancer (1.7%), 12 cases of other lesions (4.1%), and 58 cases of undiagnosable lesions (19.9%). The frequency of malignant or potentially malignant tumour in GSELHM was 55.0% (95% CI: 49.1-60.8, 160/291). Surgery was performed in 149 patients according to the conclusive EUS-TA-CFNAN results, in which the diagnostic accuracy of EUS-TA-CFNAN was 97.3% (95% CI: 94.7-99.9, 145/149). Conclusion: The use of EUS-TA-CFNAN for GSELHMs is safe and accurate. Gastric subepithelial lesions showing a hypoechoic mass have a reasonably high possibility of containing malignant or potentially malignant tumours, including GISTs.

3.
Turk J Gastroenterol ; 34(11): 1156-1162, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37681269

RESUMO

BACKGROUND/AIMS: For duodenal subepithelial lesions showing a hypoechoic mass on endoscopic ultrasound imaging, the utility of endoscopic ultrasound-guided fine-needle aspiration and the frequency of histological types have not been the focus of previous literature. This study aimed to clarify this. MATERIALS AND METHODS: This prospective observational study enrolled 22 consecutive patients who underwent endoscopic ultrasoundguided fine-needle aspiration for duodenal subepithelial lesions with hypoechoic mass on endoscopic ultrasound. Immunohistochemical analysis was performed for all endoscopic ultrasound-guided fine-needle aspiration and surgically resected specimens. The main outcome measures were the technical results of endoscopic ultrasound-guided fine-needle aspiration and the frequency of histological types of duodenal subepithelial lesions with hypoechoic mass. RESULTS: Thirteen fine-needle aspiration specimens were obtained from the duodenal bulb and eight from the descending duodenal region. The puncture was not performed because of intervening vessels in one patient. The diagnostic rate was 81% (95% confidence interval: 58.1-94.6, 17/21 patients). In 12 patients receiving surgical resection (excluding one cancellation of endoscopic ultrasoundguided fine-needle aspiration), the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration was 75% (95% confidence interval: 42.8-94.5, 9/12 patients). No complications were observed. The histopathological diagnoses included 11 cases of gastrointestinal stromal tumor (50%), 2 cases of leiomyoma (9%), 2 cases of metastatic cancer (9%), 2 cases of benign inconclusive, and 1 case each of carcinoid, malignant lymphoma, leiomyosarcoma, gauzeoma, and aberrant pancreas (4.5% each). The frequency of malignant tumors in the duodenal subepithelial lesions with hypoechoic mass group was 73% (16/22 patients). CONCLUSIONS: Endoscopic ultrasound-guided fine-needle aspiration for duodenal subepithelial lesions with hypoechoic mass was safe and accurate. As duodenal subepithelial lesion with hypoechoic mass has a reasonably high possibility of containing malignant tumors, it is desirable to perform endoscopic ultrasound-guided fine-needle aspiration.


Assuntos
Endossonografia , Tumores do Estroma Gastrointestinal , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Pâncreas/patologia , Tumores do Estroma Gastrointestinal/patologia , Duodeno/patologia
4.
Intern Med ; 62(23): 3495-3500, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37081688

RESUMO

A 66-year-old man diagnosed with immunoglobulin G4-related sclerosing cholangitis (IgG4-SC) with diffuse intrahepatic bile duct stenosis and elevated serum IgG4 levels was referred for a further examination because of elevated serum carbohydrate antigen 19-9 levels despite treatment with corticosteroids. An umbilical nodule was found on a physical examination and a biopsy showed adenocarcinoma. Although several imaging studies revealed no changes from prior studies, bile cytology collected by endoscopic retrograde cholangiopancreatography showed adenocarcinoma. Consequently, the patient was diagnosed with cholangiocarcinoma resembling IgG4-SC after detecting an umbilical metastasis, also known as Sister Mary Joseph's nodule.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Colangite Esclerosante , Masculino , Humanos , Idoso , Colangite Esclerosante/diagnóstico , Imunoglobulina G , Colangiocarcinoma/diagnóstico , Colangiocarcinoma/patologia , Ductos Biliares Intra-Hepáticos/patologia , Neoplasias dos Ductos Biliares/diagnóstico , Neoplasias dos Ductos Biliares/patologia , Diagnóstico Diferencial
6.
World J Gastrointest Surg ; 13(8): 772-787, 2021 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-34512901

RESUMO

Endoscopic submucosal dissection (ESD) is a globally accepted minimally invasive therapy for early-stage gastrointestinal tract tumors. Although numerous electrosurgical knives have been developed for ESD, technical difficulties and high complication rates (bleeding and perforation) have limited their use worldwide. The grasping-type scissors forceps [clutch cutter (CC)] is the first forceps-type resection device developed with reference to hemostatic forceps. The aim was to allow easy and safe ESD throughout the gastrointestinal tract, as a biopsy technique, using one device. The CC can grasp the target tissue accurately and pull it away from the underlying muscle layer prior to energizing the tissue, for safe and effective incision and hemostasis during ESD. Reported clinical studies showed that ESD using the CC (ESD-CC) is a safe (perforation rate: 0%-3.6%; delayed bleeding rate: 0%-4.2%), technically efficient (en-bloc resection rate: 88.9%-100%), and single-device method for dissecting early-stage gastrointestinal tract tumors. The ESD-CC technique is simple and easy to learn because it can be completed simply by repeating the grasp, pull, and coagulate and/or incise actions using an electrosurgical current. The reported self-completion rate by non-experts was significantly better with the CC than with conventional knives (61.7% vs 24.5%, respectively; P < 0.001). Furthermore, the CC is used for other endoscopic therapies, such as endoscopic polypectomy for large pedunculated polyps, endoscopic myotomy for Zenker's diverticulum, endoscopic treatment of buried bumper syndrome, and endoscopic necrosectomy for wall-off pancreatic necrosis. The initial reports using CC for these therapies have shown favorable results. In this review, we describe the structural features of the CC, how to use the instrument, efficacies of ESD-CC, and other unique endoscopic therapies using the CC.

7.
World J Gastrointest Endosc ; 13(4): 111-114, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33959233

RESUMO

Endoscopists are at high risk of allowing transmission of coronavirus disease 2019 (COVID-19) during gastrointestinal endoscopy (GIE) procedures under pandemic conditions. The main avenues of droplet-containing aerosol generated during GIE are the mouth, anus, and endoscopic forceps channel. Although the usefulness of personal protective equipment for preventing COVID-19 dissemination has been well reported, measures to address infected aerosol escaping during endoscopic forceps use have been neglected. Pathogen-contaminated aerosol from the endoscopic forceps channel, leading into the gastrointestinal lumen, has been confirmed and is a highly problematic source of infection. We developed a technique that entails covering the forceps entry/exit hole with a vinyl bag, thereby preventing contamination of the endoscopy room by the infected aerosol that escapes from this hole. The technique can be used in daily clinical endoscopic practice. Furthermore, this shielding technique is useful for all patients who undergo GIE, regardless of the purpose of the procedure such as for making a diagnosis, administering therapy, or in an urgent situation. In this letter, we introduce our novel, easily performed, inexpensive method of infection prevention by disallowing infected aerosol to escape from a COVID-19-infected patient into the air during a procedure that requires the use of endoscopic forceps.

10.
Curr Treat Options Oncol ; 21(12): 98, 2020 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-33104938

RESUMO

OPINION STATEMENT: With the widespread use of esophagogastroduodenoscopy in recent years, the detection rate of superficial non-ampullary duodenal epithelial tumors (SNADETs) is increasing. Most SNADETs are early-stage adenocarcinoma or benign conditions, including adenoma. Therefore, endoscopic resection is desirable from the perspective of quality of life. However, endoscopic resection for SNADETs has not yet been established. Endoscopic submucosal dissection (ESD) is the most promising method for the treatment of SNADETs, because ESD provides a high rate of en bloc resection and a low rate of recurrence regardless of the tumor size. However, the difficulty of the procedure and a high rate of severe adverse events including perforation and bleeding have become major problems. Various preventive countermeasures for adverse events, such as use of specific devices, endoscope stabilization methods, and endoscopic closure of the post-ESD ulcer using clips, are reported to reduce the risk of the adverse events of ESD for SNADETs. This article reviews and highlights the current state of ESD for SNADETs and new challenges towards safe and effective ESD.


Assuntos
Carcinoma/patologia , Carcinoma/cirurgia , Neoplasias Duodenais/patologia , Neoplasias Duodenais/cirurgia , Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Ressecção Endoscópica de Mucosa/métodos , Humanos , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia
11.
VideoGIE ; 4(10): 486-492, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31709338

RESUMO

BACKGROUND AND AIMS: The Clutch Cutter (CC) can grasp, pull, coagulate, and incise targeted tissue with the use of electrosurgical current. It was developed as a biopsy technique to reduce the technical difficulty of endoscopic submucosal dissection (ESD) with knives. The aim of this study was to evaluate the efficacy and safety of ESD using the CC (ESD-CC) for early colorectal epithelial neoplasms (ECENs). METHODS: In this prospective study, we enrolled 437 consecutive patients with a diagnosis of ECEN between January 2009 and January 2018. They all satisfied the Japanese colorectal cancer treatment guidelines for ESD; namely, confirmation by preliminary endoscopy, EUS, and endoscopic biopsy. The CC was used for all steps of ESD (mucosal incision, submucosal dissection, and hemostatic treatment); therapeutic efficacy and safety were assessed. RESULTS: The en bloc resection rate was 99.3% (434/437), and the R0 resection rate was 87.0% (380/437). The mean operating time was 88.3 minutes. Perforation occurred in 10 cases (2.3%) and was managed with conservative medical treatment. Post-ESD-CC bleeding occurred in 10 cases (2.3%) and was successfully treated by endoscopic hemostatic treatment. CONCLUSIONS: ESD-CC is a technically efficient, safe, and easy method for resecting ECEN.

12.
World J Gastrointest Endosc ; 9(7): 334-340, 2017 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-28744346

RESUMO

AIM: To evaluate the efficacy and safety of endoscopic submucosal dissection (ESD) using the clutch cutter (CC) (ESD-CC) for gastric adenoma (GA). METHODS: From June 2007 to August 2015, 122 consecutive patients with histological diagnoses of GA from specimens resected by ESD-CC were enrolled in this prospective study. The CC was used for all ESD steps (marking, mucosal incision, submucosal dissection, and hemostatic treatment), and its therapeutic efficacy and safety were assessed. RESULTS: Both the en-bloc resection rate and the R0 resection rate were 100% (122/122). The mean surgical time was 77.4 min, but the time varied significantly according to tumor size and location. No patients suffered perforation. Post-ESD-CC bleeding occurred in six cases (4.9%) that were successfully resolved by endoscopic hemostatic treatment. CONCLUSION: ESD-CC is a technically efficient, safe, and easy method for resecting GA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA