Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 303
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38642290

RESUMO

Despite guideline-based recommendation of the interchangeable use of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) to guide revascularization decision-making, iFR/FFR could demonstrate different physiological or clinical outcomes in some specific patient or lesion subsets. Therefore, we sought to investigate the impact of difference between iFR and FFR-guided revascularization decision-making on clinical outcomes in patients with left main disease (LMD). In this international multicenter registry of LMD with physiological interrogation, we identified 275 patients in whom physiological assessment was performed with both iFR/FFR. Major adverse cardiovascular event (MACE) was defined as a composite of death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The receiver-operating characteristic analysis was performed for both iFR/FFR to predict MACE in respective patients in whom revascularization was deferred and performed. In 153 patients of revascularization deferral, MACE occurred in 17.0% patients. The optimal cut-off values of iFR and FFR to predict MACE were 0.88 (specificity:0.74; sensitivity:0.65) and 0.76 (specificity:0.81; sensitivity:0.46), respectively. The area under the curve (AUC) was significantly higher for iFR than FFR (0.74; 95%CI 0.62-0.85 vs. 0.62; 95%CI 0.48-0.75; p = 0.012). In 122 patients of coronary revascularization, MACE occurred in 13.1% patients. The optimal cut-off values of iFR and FFR were 0.92 (specificity:0.93; sensitivity:0.25) and 0.81 (specificity:0.047; sensitivity:1.00), respectively. The AUCs were not significantly different between iFR and FFR (0.57; 95%CI 0.40-0.73 vs. 0.46; 95%CI 0.31-0.61; p = 0.43). While neither baseline iFR nor FFR was predictive of MACE in patients in whom revascularization was performed, iFR-guided deferral seemed to be safer than FFR-guided deferral.

3.
J Clin Med ; 13(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610628

RESUMO

Background: Transthoracic echocardiography (TTE) is the gold standard modality for evaluating cardiac morphology, function, and hemodynamics in clinical practice. While artificial intelligence (AI) is expected to contribute to improved accuracy and is being applied clinically, its impact on daily clinical practice has not been fully evaluated. Methods: We retrospectively examined 30 consecutive patients who underwent AI-equipped TTE at a single institution. All patients underwent manual and automatic measurements of TTE parameters using the AI-equipped TTE. Measurements were performed by three sonographers with varying experience levels: beginner, intermediate, and expert. Results: A comparison between the manual and automatic measurements assessed by the experts showed extremely high agreement in the left ventricular (LV) filling velocities (E wave: r = 0.998, A wave: r = 0.996; both p < 0.001). The automated measurements of LV end-diastolic and end-systolic diameters were slightly smaller (-2.41 mm and -1.19 mm) than the manual measurements, although without significant differences, and both methods showing high agreement (r = 0.942 and 0.977, both p < 0.001). However, LV wall thickness showed low agreement between the automated and manual measurements (septum: r = 0.670, posterior: r = 0.561; both p < 0.01), with automated measurements tending to be larger. Regarding interobserver variabilities, statistically significant agreement was observed among the measurements of expert, intermediate, and beginner sonographers for all the measurements. In terms of measurement time, automatic measurement significantly reduced measurement time compared to manual measurement (p < 0.001). Conclusions: This preliminary study confirms the accuracy and efficacy of AI-equipped TTE in routine clinical practice. A multicenter study with a larger sample size is warranted.

4.
Eur Heart J Open ; 4(2): oeae018, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38529170

RESUMO

Aims: Current evidence on the prognostic value of exercise stress echocardiography (ESE) in asymptomatic patients with low-gradient severe aortic stenosis (AS) is limited. Therefore, this study aimed to elucidate its prognostic implications for patients with low-gradient severe AS and determine the added value of ESE in risk stratification for this population. Methods and results: This retrospective observational study included 122 consecutive asymptomatic patients with either moderate [mean pressure gradient (MPG) < 40 mmHg and aortic valve area (AVA) 1.0-1.5 cm2] or low-gradient severe (MPG < 40 mmHg and AVA < 1.0 cm2) AS and preserved left ventricular ejection fraction (≥50%) who underwent ESE. All patients were followed up for AS-related events. Of 143 patients, 21 who met any exclusion criteria, including early interventions, were excluded, and 122 conservatively managed patients [76.5 (71.0-80.3) years; 48.3% male] were included in this study. During a median follow-up period of 989 (578-1571) days, 64 patients experienced AS-related events. Patients with low-gradient severe AS had significantly lower event-free survival rates than those with moderate AS (log-rank test, P < 0.001). Multivariable Cox regression analysis showed that the mitral E/e' ratio during exercise was independently associated with AS-related events (hazard ratio = 1.075, P < 0.001) in patients with low-gradient severe AS. Conclusion: This study suggests that asymptomatic patients with low-gradient severe AS have worse prognoses than those with moderate AS. Additionally, the mitral E/e' ratio during exercise is a useful parameter for risk stratification in patients with low-gradient severe AS.

6.
JACC Case Rep ; 29(4): 102216, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379648

RESUMO

A 70-year-old patient with paroxysmal atrial fibrillation underwent left atrial appendage closure. The patient experienced transient hypotension during device implantation. The procedure was abandoned because of ST-T-wave changes on electrocardiography and elevated coronary flow velocity on transesophageal echocardiography, which indicated that the device caused coronary artery compression.

7.
Circ J ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38311419

RESUMO

BACKGROUND: High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs.Methods and Results: The amount of adipose tissue adjacent to the device and anteroposterior diameter at the basal heart region were measured preoperatively using chest CT. We examined the correlation between these measurements and shock impedance at the conversion test. We enrolled 43 patients with S-ICDs (mean [±SD] age 54±15 years; body mass index 23±4 kg/m2; PRAETORIAN score 30-270 points; amount of adipose tissue 1,250±716 cm3), who underwent intraoperative conversion tests by inducing ventricular fibrillation, which was terminated with a 65-J shock. A sufficient concordance correlation coefficient was observed between the shock impedance and the amount of adipose tissue (r=0.616, P<0.01) and anteroposterior diameter (r=0.645, P<0.01). In multiple regression analysis, the amount of adipose tissue (ß=0.439, P=0.009) and anteroposterior diameter (ß=0.344, P=0.038) were identified as independent predictive factors of shock impedance. CONCLUSIONS: The preoperative CT-measured amount of adipose tissue and basal heart anteroposterior diameter are independent predictors of shock impedance. These parameters may be more accurate in identifying higher shock impedance in patients with S-ICDs.

8.
Circ J ; 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38220206

RESUMO

BACKGROUND: This study aimed to clarify the effects of exercise-based cardiac rehabilitation (CR) on patients with heart failure.Methods and Results: Patients were divided into groups according to intervention duration (<6 and ≥6 months). We searched for studies published up to July 2023 in Embase, MEDLINE, PubMed, and the Cochrane Library, without limitations on data, language, or publication status. We included randomized controlled trials comparing the efficacy of CR and usual care on mortality, prehospitalization, peak oxygen uptake (V̇O2), and quality of life. Seventy-two studies involving 8,495 patients were included in this review. It was found that CR reduced the risk of rehospitalization for any cause (risk ratio [RR] 0.80; 95% confidence interval [CI] 0.70-0.92) and for heart failure (RR 0.88; 95% CI 0.78-1.00). Furthermore, CR was found to improve exercise tolerance (measured by peak V̇O2and the 6-min walk test) and quality of life. A subanalysis performed based on intervention duration (<6 and ≥6 months) revealed a similar trend. CONCLUSIONS: Our meta-analysis showed that although CR does not reduce mortality, it is effective in reducing rehospitalization rates and improving exercise tolerance and quality of life, regardless of the intervention duration.

9.
J Gen Fam Med ; 25(1): 53-61, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38240001

RESUMO

Background: Coronavirus disease 2019 (COVID-19) sequelae, also known as long COVID, can present with various symptoms. Among these symptoms, autonomic dysregulation, particularly postural orthostatic tachycardia syndrome (POTS), should be evaluated. However, previous studies on the treatment of POTS complicated by COVID-19 are lacking. Therefore, this study aimed to investigate the treatment course of long COVID complicated by POTS. Methods: The medical records of patients who complained of fatigue and met the criteria for POTS diagnosis were reviewed. We evaluated the treatment days, methods and changes in fatigue score, changes in heart rate on the Schellong test, and social situation at the first and last visits. Results: Thirty-two patients with long COVID complicated by POTS were followed up (16 males; median age: 28 years). The follow-up period was 159 days, and the interval between COVID-19 onset and initial hospital attendance was 97 days. Some patients responded to ß-blocker therapy. Many patients had psychiatric symptoms that required psychiatric intervention and selective serotonin reuptake inhibitor prescription. Changes in heart rate, performance status, and employment/education status improved from the first to the last visit. These outcomes were believed to be because of the effects of various treatment interventions and spontaneous improvements. Conclusions: Our study suggests that the condition of 94% of patients with POTS complicated by long COVID will improve within 159 days. Therefore, POTS evaluation should be considered when patients with long COVID complain of fatigue, and attention should be paid to psychological symptoms and the social context.

10.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37500393

RESUMO

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Estudos de Viabilidade , Meios de Contraste/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
11.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37438144

RESUMO

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Angiografia , Insuficiência Cardíaca/diagnóstico por imagem , Estimativa de Kaplan-Meier , Rim/diagnóstico por imagem , Resultado do Tratamento
12.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37543193

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Qualidade de Vida , Análise Custo-Benefício , Estudos Prospectivos , Fragilidade/etiologia , Estenose da Valva Aórtica/etiologia , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
13.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38008428

RESUMO

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Modelos de Riscos Proporcionais , Cateterismo Cardíaco
14.
Echocardiography ; 41(1): e15712, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37937359

RESUMO

BACKGROUNDS: There are limited data on the clinical relevance of transvalvular flow rate (Qmean ) at rest (Qrest) and at peak stress (Qstress ) during dobutamine stress echocardiography (DSE) in patients with low-gradient severe aortic stenosis (LG-SAS). METHODS: We retrospectively analyzed the clinical data of patients with LG-SAS who underwent DSE. LG-SAS was defined as an aortic valve (AV) area index of < .6 cm2 /m2 and a mean AV pressure gradient (AVPG) of < 40 mm Hg. The primary endpoint included all-cause death and heart failure hospitalization. RESULTS: Of 100 patients (mean age 79.5 ± 7.3 years; men, 45.0%; resting left ventricular ejection fraction [LVEF] 52.1% ± 15.9%; resting stroke volume index 35.8 ± 7.7 mL/m2 ; Qrest 171.8 ± 34.9 mL/s), the primary endpoint occurred in 51 patients during a median follow-up of 2.84 (interquartile range 1.01-5.21) years. When the study patients were divided into three subgroups based on Qrest and Qstress , the multivariate analysis showed that Qrest < 200 mL/s and Qstress ≥200 mL/s (hazard ratio 3.844; 95% confidence interval 1.143-12.930; p = .030), as well as Qrest and Qstress < 200 mL/s (hazard ratio 9.444; 95% confidence interval 2.420-36.850; p = .001), were significantly associated with unfavorable outcomes with Qrest and Qstress ≥200 mL/s as a reference after adjusting for resting LVEF, resting mean AVPG, chronic kidney disease, New York Heart Association functional class III/IV, and AV replacement. CONCLUSIONS: Flow conditions based on the combination of Qrest and Qstress are helpful for risk stratification in LG-SAS patients.


Assuntos
Estenose da Valva Aórtica , Função Ventricular Esquerda , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Volume Sistólico , Prognóstico , Ecocardiografia sob Estresse , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Índice de Gravidade de Doença
15.
Cardiovasc Interv Ther ; 39(1): 74-82, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37938532

RESUMO

The safety and feasibility are still not well known for exercise-induced mitral regurgitation (MR). This study is aimed to assess and compare the hemodynamic and symptomatic changes in patients with significant secondary MR during exercise stress echocardiography (ESE) before and after transcatheter edge-to-edge repair (TEER). The study included a total of 15 patients with secondary MR who underwent ESE before and after TEER using the MitraClip system (Abbott, Abbott Park, IL, USA). Echocardiographic data of ESE were collected both before the procedure and during the follow-up visit at 3 months. During the one-year postoperative observation period, the rate of readmission due to heart failure was 13% (n = 2), with no recorded fatalities. Although no significant differences of ESE data were observed in exercise-induced pulmonary hypertension or cardiac output before and after the repair, the severity of MR was significantly improved after the procedure, both at rest (2 [2-3] vs. 1 [1-2], p = 0.0125) and during ESE (3 [3-3] vs. 1 [1-1], p < 0.0001). Furthermore, the New York Heart Association Functional Classification was improved (3 [3-3] vs. 1 [1-1], p < 0.0001) after treatment. For a supplemental analysis, MR during ESE was significantly improved not only in cases with atrial secondary MR but also in ventricular secondary MR. Transcatheter edge-to-edge repair for exercise-induced MR resulted in a significant improvement in postoperative MR severity and subjective symptoms. These results are novel, as they have not been extensively reported previously, particularly among Japanese patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ecocardiografia sob Estresse , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco
17.
Am J Cardiol ; 210: 259-265, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37875233

RESUMO

Aortic stenosis is a prevalent valvular heart disease, especially in the older people. They often coexist with other co-morbidities, and noncardiac surgery carries a higher risk because of the underlying valve condition. Despite the growing concern about the safety and optimal management of noncardiac surgery post-transcatheter aortic valve replacement (TAVR), there is limited evidence on this matter. This study aims to assess the clinical outcomes of noncardiac surgeries after TAVR. This retrospective study included 718 patients who underwent TAVR. Of these, 36 patients underwent noncardiac surgery after TAVR. The primary end point was the incidence of cardiovascular adverse events post-TAVR and the secondary end point was the incidence of structural valve deterioration. Composite end points included disabling stroke, heart failure requiring hospitalization, and cardiac death as defined by Valve Academic Research Consortium 3. Most of these surgeries were orthopedic and classified as intermediate risk. All noncardiac surgeries were performed without perioperative adverse events. There was no observed structural valve deterioration, and the incidence of composite end points did not significantly differ between the surgical and nonsurgical groups during the follow-up period. Noncardiac surgery after TAVR can be performed safely and does not have a negative impact on prognosis. Further studies are warranted to determine the optimal strategy for noncardiac surgery after TAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Prevalência , Fatores de Risco , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos
18.
Circ Rep ; 5(12): 442-449, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38073869

RESUMO

Background: A high score for controlling nutritional status (CONUT) due to poor nutritional status has been associated with adverse outcomes in patients with chronic heart failure. However, because little is known about the effect of CONUT score on mortality rates after transcatheter mitral valve repair, we evaluated nutrition screening tools for prognosis prediction in patients undergoing transcatheter mitral valve repair using the MitraClipTM system. Methods and Results: We retrospectively analyzed 148 patients with severe mitral regurgitation (MR) who underwent MitraClipTM implantation between April 2018 and April 2021. The preprocedural CONUT scores were assessed at the time of hospitalization, the primary outcome was all-cause death, and the analysis was of the mortality and incidence rates of cardiac events 1 year post-operation. Functional MR was of ischemic origin in the majority of patients (69.6%), with a mean left ventricular ejection fraction of 48.9±15.8%. Kaplan-Meier curves indicated that all-cause death was significantly worse in the high-CONUT score group than in the low-CONUT score group. Cox hazard analysis showed a significant association between all-cause death and CONUT score, as well as MitraScore. Conclusions: Preprocedural CONUT score, as well as MitraScore, in patients undergoing transcatheter edge-to-edge mitral valve repair may predict an increased risk of all-cause death. This knowledge should allow the heart team to accurately assess the clinical implications and prognostic benefits of the procedure in individual patients.

19.
Int Heart J ; 64(6): 1157-1161, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-37967987

RESUMO

A 59-year-old man who had been diagnosed with human immunodeficiency virus-associated cardiomyopathy was referred for catheter ablation of ventricular tachycardia (VT). An electrocardiogram (ECG) waveform revealed that the clinical VT originated from the epicardium. A deceleration zone (DZ) was identified on an isochronal late activation map. Moreover, 2 forms of monomorphic VT were induced by different cycle length burst pacings from near the DZ. The morphologies of the 2 VTs with an identical cycle length were very likely to use a shared common pathway with bi-directional conduction around the slow conduction area in the left ventricle posterolateral small epicardial surface area. After ablation of the DZ, the VT was uninducible.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Frequência Cardíaca/fisiologia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Resultado do Tratamento
20.
Sci Rep ; 13(1): 20602, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996502

RESUMO

Weather conditions influence the incidence of cardiovascular disease. However, few studies have investigated the association between weather temperature and humidity and cerebrovascular disease hospitalizations in a super-aging society. We included 606,807 consecutive patients with cerebrovascular disease admitted to Japanese acute-care hospitals between 2015 and 2019. The primary outcome was the number of cerebrovascular disease hospitalizations per day. Multilevel mixed-effects linear regression models were used to estimate the association of mean temperature and humidity, 1 day before hospital admission, with cerebrovascular disease hospitalizations, after adjusting for air pollution, hospital, and patient demographics. Lower mean temperatures and humidity < 70% or humidity ≧ 70% are associated with an increased incidence of cerebrovascular disease hospitalization (coefficient, - 1.442 [- 1.473 to - 1.411] per °C, p < 0.001, coefficient, - 0.084 [- 0.112 to - 0.056] per%, p < 0.001, and coefficient, 0.136 [0.103 to 0.168] per %, p < 0.001, respectively). Lower mean temperatures and extremely lower or higher humidity are associated with an increased incidence of cerebrovascular disease hospitalization in a super-aging society.


Assuntos
Transtornos Cerebrovasculares , Hospitalização , Humanos , Envelhecimento , Transtornos Cerebrovasculares/epidemiologia , Umidade , Temperatura , Tempo (Meteorologia)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA