Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(12): 2431-2443, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36259717

RESUMO

INTRODUCTION: Catheter-ablation (CA) of consecutive left atrial tachycardias (LAT) can be challenging. Pulsed field ablation (PFA) yields a novel nonthermal CA technology for treatment of atrial fibrillation (AF). There is no data regarding PFA of LAT. This study sought to investigate PFA of consecutive LAT following prior CA of AF. METHODS: Consecutive patients with LAT underwent ultrahigh-density (UHDx) mapping. Subsequent to identification of the AT mechanism, PFA was performed at the assumed critical sites for LAT maintenance. Continuous ablation lines were performed if required and evaluated with pre- and post-PFA HDx-mapping. RESULTS: Fifteen patients (age 70 ± 10, male 73%) who underwent 3.6 ± 2 prior AF-CA procedures were included. The total mean procedure and fluoroscopy times were 141 ± 43 and 18 ± 10 min, respectively. All 19 of 19 (100%) LAT were successfully ablated with PFA. Two AT located at the right atria required RF-ablation. LAT were identified as localized reentry (n = 1) and macro-reentry LAT (n = 18) and targeted with PFA. All LAT terminated with PFA either to sinus rhythm (9/15) or a secondary AT (6/15 and subsequently to SR); 63% (12/19) terminated with the first PFA-application. All lines (13 roof, 11 anterior, 1 mitral) were blocked. LA-posterior-wall isolation (LAPWI) was successfully achieved when performed (10/10). AF/AT free survival was 80% (12/15) after 153 [88-207] days of follow-up. No procedure-related complications occurred. CONCLUSION: PFA of consecutive LAT is feasible and safe. Successful creation of ablation lines and LAPWI can be achieved in a short time. PFA may offer the opportunity for effective ablation of atrial arrhythmias beyond AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Taquicardia , Resultado do Tratamento , Veias Pulmonares/cirurgia
2.
J Cardiovasc Dev Dis ; 9(8)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-36005407

RESUMO

Myocarditis is characterized by various clinical manifestations, with ventricular arrhythmia (VA) as a frequent symptom at initial presentation. Here, we investigated characteristics and prognostic relevance of VA in patients with myocarditis. The study population consisted of 76 patients with myocarditis, verified by biopsy and/or cardiac magnetic resonance (CMR) imaging, including 38 consecutive patients with VA (45 ± 3 years, 68% male) vs. 38 patients without VA (NVA) (38 ± 2 years, 84% male) serving as a control group. VA was monomorphic ventricular tachycardia in 55% of patients, premature ventricular complexes in 50% and ventricular fibrillation in 29%. The left ventricular ejection fraction at baseline was 47 ± 2% vs. 40 ± 3% in VA vs. NVA patients (p = 0.069). CMR showed late gadolinium enhancement more often in VA patients (94% vs. 69%; p = 0.016), incorporating 17.6 ± 1.8% vs. 8.2 ± 1.3% of myocardial mass (p < 0.001). Radiofrequency catheter ablation for VA was initially performed in nine (24%) patients, of whom five remained free from any recurrence over 24 ± 3 months. Taken together, in patients with myocarditis, reduced left ventricular ejection fraction does not predict VA occurrence but CMR shows late gadolinium enhancement more frequently and to a larger extent in VA than in NVA patients, potentially guiding catheter ablation as a reasonable treatment of VA in this population.

3.
J Cardiovasc Electrophysiol ; 33(3): 345-356, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34978360

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrofisiologia Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
5.
Europace ; 23(10): 1548-1558, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-33895833

RESUMO

AIMS: Weight management seems to be beneficial for obese atrial fibrillation (AF) patients; however, randomized data are sparse. Thus, this study aimed to investigate the influence of weight reduction on AF ablation outcomes. METHODS AND RESULTS: SORT-AF is an investigator-sponsored, prospective, randomized, multicentre, and clinical trial. Patients with symptomatic AF (paroxysmal or persistent) and body mass index (BMI) 30-40 kg/m2 underwent AF ablation and were randomized to either weight-reduction (group 1) or usual care (group 2), after sleep-apnoea-screening and loop recorder (ILR) implantation. The primary endpoint was defined as AF burden between 3 and 12 months after AF ablation. Overall, 133 patients (60 ± 10 years, 57% persistent AF) were randomized to group 1 (n = 67) and group 2 (n = 66), respectively. Complications after AF-ablation were rare (one stroke and no tamponade). The intervention led to a significant reduction of BMI (34.9 ± 2.6-33.4 ± 3.6) in group 1 compared to a stable BMI in group 2 (P < 0.001). Atrial fibrillation burden after ablation decreased significantly (P < 0.001), with no significant difference regarding the primary endpoint between the groups (P = 0.815, odds ratio: 1.143, confidence interval: 0.369-3.613). Further analyses showed a significant correlation between BMI and AF recurrence for patients with persistent AF compared with paroxysmal AF patients (P = 0.032). CONCLUSION: The SORT-AF study shows that AF ablation is safe and successful in obese patients using continuous monitoring via ILR. Although the primary endpoint of AF burden after ablation did not differ between the two groups, the effects of weight loss and improvement of exercise activity were beneficial for obese patients with persistent AF demonstrating the relevance of life-style management as an important adjunct to AF ablation in this setting. TRIAL REGISTRATION NUMBER: NCT02064114.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/diagnóstico , Estudos Prospectivos , Recidiva , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 32(2): 376-388, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33368769

RESUMO

INTRODUCTION: Substrate-based catheter ablation approaches to ventricular tachycardia (VT) focus on low-voltage areas and abnormal electrograms. However, specific electrogram characteristics in sinus rhythm are not clearly defined and can be subject to variable interpretation. We analyzed the potential ablation target size using automatic abnormal electrogram detection and studied findings during substrate mapping in the VT isthmus area. METHODS AND RESULTS: Electrogram characteristics in 61 patients undergoing scar-related VT ablation using ultrahigh-density 3D-mapping with a 64-electrode mini-basket catheter were analyzed retrospectively. Forty-four complete substrate maps with a mean number of 10319 ± 889 points were acquired. Fractionated potentials detected by automated annotation and manual review were present in 43 ± 21% of the entire low-voltage area (<1.0 mV), highly fractionated potentials in 7 ± 8%, late potentials in 13 ± 15%, fractionated late potentials in 7 ± 9% and isolated late potentials in 2 ± 4%, respectively. Highly fractionated potentials (>10 ± 1 fractionations) were found in all isthmus areas of identified VT during substrate mapping, while isolated late potentials were distant from the critical isthmus area in 29%. CONCLUSION: The ablation target area varies enormously in size, depending on the definition of abnormal electrograms. Clear linking of abnormal electrograms with critical VT isthmus areas during substrate mapping remains difficult due to a lack of specificity rather than sensitivity. However, highly fractionated, low-voltage electrograms were found to be present in all critical VT isthmus sites.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Cicatriz/diagnóstico , Cicatriz/etiologia , Humanos , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
7.
Arch Med Sci ; 16(5): 1022-1030, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32863990

RESUMO

INTRODUCTION: Respiratory sinus arrhythmia (RSA) describes heart rate (HR) changes in synchrony with respiration. It is relevant for exercise capacity and mechanistically linked with the cardiac autonomic nervous system. After pulmonary vein isolation (PVI), the current therapy of choice for patients with paroxysmal atrial fibrillation (AF), the cardiac vagal tone is often diminished. We hypothesized that RSA is modulated by PVI in patients with paroxysmal AF. MATERIAL AND METHODS: Respiratory sinus arrhythmia, measured by using a deep breathing test and heart rate variability parameters, was studied in 10 patients (64 ±3 years) with paroxysmal AF presenting in stable sinus rhythm for their first catheter-based PVI. Additionally, heart rate dynamics before and after PVI were studied during sympathetic/parasympathetic coactivation by using a cold-face test. All tests were performed within 24 h before and 48 h after PVI. RESULTS: After PVI RSA (E/I difference: 7.9 ±1.0 vs. 3.5 ±0.6 bpm, p = 0.006; E/I ratio: 1.14 ±0.02 vs. 1.05 ±0.01, p = 0.003), heart rate variability (SDNN: 31 ±3 vs. 14 ±3 ms, p = 0.006; RMSSD: 17 ±2 vs. 8 ±2 ms, p = 0.002) and the HR response to sympathetic/parasympathetic coactivation (10.2 ±0.7% vs. 5.7 ±1.1%, p = 0.014) were diminished. The PVI-related changes in RSA correlated with the heart rate change during sympathetic/parasympathetic coactivation before vs. after PVI (E/I difference: r = 0.849, p = 0.002; E/I ratio: r = 0.786, p = 0.007). One patient with vagal driven arrhythmia experienced AF recurrence during follow-up (mean: 6.5 ±0.6 months). CONCLUSIONS: Respiratory sinus arrhythmia is reduced after PVI in patients with paroxysmal AF. Our findings suggest that this is related to a decrease in cardiac vagal tone. Whether and how this affects the clinical outcome including exercise capacity need to be determined.

8.
J Cardiovasc Electrophysiol ; 31(10): 2645-2652, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32748442

RESUMO

INTRODUCTION: Tailored catheter ablation of atrial tachycardias (ATs) is increasingly recommended as a potentially easy treatment strategy in the era of high-density mapping (HDM). As follow-up data are sparse, we here report outcomes after HDM-guided ablation of ATs in patients with prior catheter ablation or cardiac surgery. METHODS AND RESULTS: In 250 consecutive patients (age 66.5 ± 0.7 years, 58% male) with ATs (98% prior catheter ablation, 13% prior cardiac surgery) an HDM-guided catheter ablation was performed with the support of a 64-electrode mini-basket catheter. A total of 354 ATs (1.4 ± 0.1 ATs per patient; mean cycle length 304 ± 4.3 ms; 64% macroreentry, 27% localized reentry, and 9% focal) with acute termination of 95% were targeted in the index procedure. A similar AT as in the index procedure recurred in five patients (2%) after a median follow-up time of 535 days (interquartile range (IQR) 25th-75th percentile: 217-841). Tailored ablation of reentry ATs with freedom from any arrhythmia was obtained in 53% after a single procedure and in 73% after 1.4 ± 0.4 ablation procedures (range: 1-4). A total of 228 patients (91%) were free from any arrhythmia recurrence after 210 days (IQR: 152-494) when including optimal usual care. CONCLUSIONS: Tailored catheter ablation of ATs guided by HDM has a high acute success rate. The recurrence rate of the index AT is low. In patients with extensive atrial scaring further ablation procedures need to be considered to achieve freedom from any arrhythmia.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 31(5): 1051-1061, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32107811

RESUMO

INTRODUCTION: The aim of this study was to investigate electrophysiological findings in patients with arrhythmia recurrence undergoing a repeat ablation procedure using ultra-high-density (UHDx) mapping following an index procedure using either contact-force (CF)-guided radiofrequency current (RFC) pulmonary vein isolation (PVI) or second-generation cryoballoon (CB) PVI for treatment of atrial fibrillation (AF). METHODS AND RESULTS: Fifty consecutive patients with recurrence of AF and/or atrial tachycardia (AT) following index CF-RFC PVI (n = 21) or CB PVI (n = 29) were included. A 64-pole mini-basket mapping catheter in combination with an UHDx-mapping system-guided ablation was used. RFC was applied using a catheter tip with three incorporated mini-electrodes. PV reconnection rates were higher after CF-RFC PVI (CF-RFC: 2.5 ± 1.3 PVs vs CB: 1.4 ± 0.9 PVs; P = .0025) and left PVs were more frequently reconnected (CF-RFC: 64% PVs vs CB: 35% PVs; P = .0077). Fractionated signals along the antral index ablation line (FS) were found in 30% of CB-PVI patients (CF-RFC: 9.5% vs CB:30%; P = .098) targeted for ablation. In five cases, FS were a critical part of maintaining consecutive AT. The main AT mechanism found during reablation (n = 45 ATs) was macroreentry (80% [36/45], CF-RFC: 78.9% vs CB: 80.8%; P = 1.0) with a variety of circuits throughout both atria. CONCLUSION: UHDx mapping is sensitive in detecting conduction gaps along the index ablation line. Left PVs are more frequently reconnected after initial CF-RFC PVI. FS are a common finding after CB PVI and can maintain certain forms of ATs. ATs after index PVI are mostly macroreentries with a broad spectrum of entities.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 31(1): 61-69, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31701589

RESUMO

AIMS: Catheter contact and local tissue characteristics are relevant information for successful radiofrequency current (RFC)-ablation. Local impedance (LI) has been shown to reflect tissue characteristics and lesion formation during RFC-ablation. Using a novel ablation catheter incorporating three mini-electrodes, we investigated LI in relation to generator impedance (GI) in patients with ventricular tachycardia (VT) and its applicability as an indicator of effective RFC-ablation. METHODS AND RESULTS: Baseline impedance, Δimpedance during ablation and drop rate (Δimpedance/time) were analyzed for 625 RFC-applications in 28 patients with recurrent VT undergoing RFC-ablation. LI was lower in scarred (87.0 Ω [79.0-95.0]) compared to healthy myocardium (97.5 Ω ([82.75-111.50]; P = .03) while GI did not differ between scarred and healthy myocardium. ΔLI was higher (18 Ω [9.4-26.0]) for VT-terminating as compared to non-terminating RFC-ablation (ΔLI 13 Ω [8.85-18.0]; P = .03), but did not differ for ΔGI between terminating vs nonterminating RFC-ablation. Correspondingly, LI drop rate was higher for RFC-ablation terminating the VT compared with RFC-ablation not terminating the VT (0.63 Ω/s [0.52-0.76] vs 0.32 Ω [0.20-0.58]; P = .008) while there was no difference for GI drop rate. ΔLI was higher in patients with nonischemic cardiomyopathy vs patients with ischemic cardiomyopathy (16 Ω [11.0-20.0] vs 11.0 Ω [7.85-17.00]; P = .003). CONCLUSION: Our findings suggest that LI is a sensitive parameter to guide RFC-ablation in patients with VT. LI indicates differences in tissue characteristics and generally is higher in patients with nonischemic cardiomyopathy. Hence, the etiology of the underlying cardiomyopathy needs to be considered when adopting LI for monitoring catheter ablation of VT.


Assuntos
Ablação por Cateter , Impedância Elétrica , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Idoso , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
11.
Cardiovasc Diagn Ther ; 9(Suppl 2): S247-S263, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31737533

RESUMO

BACKGROUND: Ultra-high density mapping (HDM) is a promising tool in the treatment of patients with complex arrhythmias. In adults with congenital heart disease (CHD), rhythm disorders are among the most common complications but catheter ablation can be challenging due to heterogenous anatomy and complex arrhythmogenic substrates. Here, we describe our initial experience using HDM in conjunction with novel automated annotation algorithms in patients with moderate to great CHD complexity. METHODS: We studied a series of consecutive adult patients with moderate to great CHD complexity and an indication for catheter ablation due to symptomatic arrhythmia. HDM was conducted using the Rhythmia™ mapping system and a 64-electrode mini-basket catheter for identification of anatomy, voltage, activation pattern and critical areas of arrhythmia for ablation guidance. To investigate novel advanced mapping strategies, postprocedural signal processing using the Lumipoint™ software was applied. RESULTS: In 19 patients (53±3 years; 53% male), 21 consecutive ablation procedures were conducted. Procedures included ablation of atrial fibrillation (n=7; 33%), atrial tachycardia (n=11; 52%), atrioventricular accessory pathway (n=1; 5%), the atrioventricular node (n=1; 5%) and ventricular arrhythmias (n=4; 19%). A total of 23 supraventricular and 8 ventricular arrhythmias were studied with the generation of 56 complete high density maps (atrial n=43; ventricular n=11, coronary sinus n=2) and an average of 12,043±1,679 mapping points. Multiple arrhythmias were observed in n=7 procedures (33% of procedures; range of arrhythmias detected 2-4). A total range of 1-4 critical areas were defined per procedure and treated within a radiofrequency application time of 16 (interquartile range 12-45) minutes. Postprocedural signal processing using Lumipoint™ allowed rapid annotation of fractionated signals within specific windows of interest. This supported identification of a practical critical isthmus in 20 out of 27 completed atrial and ventricular tachycardia activation maps. CONCLUSIONS: Our findings suggest that HDM in conjunction with novel automated annotation algorithms provides detailed insights into arrhythmia mechanisms and might facilitate tailored catheter ablation in patients with moderate to great CHD complexity.

12.
JACC Clin Electrophysiol ; 5(4): 417-426, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31000095

RESUMO

OBJECTIVES: This study sought to characterize primary left atrial tachycardia (LAT) mechanisms, electrical properties and substrate using high-density mapping. BACKGROUND: Nonfocal LAT can be found in patients without prior substrate modifying interventions. METHODS: Of 223 catheter ablation procedures for LAT 15 patients (60% male, age 74 ± 6 years) had nonfocal AT and no history of LA ablation or cardiac surgery. RESULTS: AT (mean cycle length 244 ± 32 ms) were identified as macro-re-entry (12 of 15) or localized re-entry (3 of 15). High-density electroanatomical mapping (EAM, performed in 13 patients) revealed a high proportion of low voltage areas (LVA, <0.45 mV, 41 ± 22%). Anterior LVA regions were predominantly related to the macro-re-entry and directly perpetuating the re-entrant circuit in 8 patients by formation of a conductive channel (width: 14 ± 7 mm, length: 11 ± 3 mm) between the inferior pole of the scar and the mitral valve (MV) annulus with electrophysiological features of diseased tissue. A tailored anterior ablation line successfully terminated AT in 9 patients (6 dominant circuit MV dependent, 3 dominant circuit scar dependent AT), while a lateral isthmus line was performed in 2 patients. Localized re-entries were successfully targeted by local ablation. Acute successful ablation could be achieved in 14 of 15 patients leading to a freedom from any arrhythmias in 9 of 15 patients (60%) after follow-up of 343 ± 203 days. CONCLUSIONS: Patients with nonfocal left atrial tachycardia without previous iatrogenic interventions show evidence for advanced atrial myopathy. High-density mapping revealed involvement of the anterior LA and allows for an individualized ablation approach beyond strategies usually applied in consecutive AT.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Taquicardia , Idoso , Idoso de 80 Anos ou mais , Feminino , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Humanos , Masculino , Estudos Prospectivos , Taquicardia/diagnóstico , Taquicardia/fisiopatologia , Taquicardia/cirurgia
13.
Europace ; 21(Supplement_1): i34-i42, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30801126

RESUMO

AIMS: A novel measure of local impedance (LI) has been found to predict lesion formation during radiofrequency current (RFC) catheter ablation. The aim of this study was to investigate the utility of this novel approach, while comparing LI to the well-established generator impedance (GI). METHODS AND RESULTS: In 25 consecutive patients with a history of atrial fibrillation, catheter ablation was guided by a 3D-mapping system measuring LI in addition to GI via an ablation catheter tip with three incorporated mini-electrodes. Local impedance and GI before and during RFC applications were studied. In total, 381 RFC applications were analysed. The baseline LI was higher in high-voltage areas (>0.5 mV; LI: 110.5 ± 13.7 Ω) when compared with intermediate-voltage sites (0.1-0.5 mV; 90.9 ± 10.1 Ω, P < 0.001), low-voltage areas (<0.1 mV; 91.9 ± 16.4 Ω, P < 0.001), and blood pool LI (91.9 ± 9.9 Ω, P < 0.001). During ablation, mean LI drop (△LI; 13.1 ± 9.1 Ω) was 2.15 times higher as mean GI drop (△GI) (6.1 ± 4.2 Ω, P < 0.001). Baseline LI correlated with △LI: a mean LI of 99.9 Ω predicted a △LI of 12.9 Ω [95% confidence interval (12.1-13.6), R2 0.41; P < 0.001]. This relationship was weak for baseline GI predicting △GI (R2 0.06, P < 0.001). Catheter movements were represented by rapid LI changes. The duration of an RFC application was not predictive for catheter-tissue coupling with no further change of △LI (P = 0.247) nor △GI (P = 0.376) during prolonged ablation. CONCLUSION: Local impedance can be monitored during ablation. Compared with the sole use of GI, baseline LI is a better predictor of impedance drops during ablation and may provide useful insights regarding lesion formation. However, further studies are needed to investigate if this novel approach is useful to guide catheter ablation.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Impedância Elétrica , Idoso , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Projetos Piloto , Ondas de Rádio
14.
Clin Res Cardiol ; 107(8): 632-641, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29500567

RESUMO

AIMS: Contact force (CF) catheters provide catheter-tissue contact information to improve outcome of pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (PAF). We evaluated different target-CF values for achievement of the additional endpoint of an unexcitable ablation line. METHODS: A total of 106 patients undergoing PVI were randomized into three groups (G) (G1: target-CF 15 g, G2: target-CF 10 g, G3: CF concealed from operator). The PVI encircling line was divided into predefined sections. Excitable tissue along the PVI-line identified by high output pacing (10 V, 2 ms) was targeted for further ablation. RESULTS: Mean average CF was 17.4 ± 4.7 g (G1) vs. 12.3 ± 6.0 g (G2) vs. 11.1 ± 6.5 g (G 3) (p < 0.001). Primary unexcitable ablation lines were found in 38.6, 19.4 and 5.7% (G1, G2, G3 respectively; G1 vs. G2 p < 0.05, G1 vs. G3 p < 0.001, G2 vs. G3 ns). Additional radiofrequency (RF)-energy to achieve unexcitability was lowest in G1 (3.6 ± 3.1 kJ vs. 8.6 ± 7.2 kJ (G2) and 10.4 ± 6.7 (G3), p ≤ 0.001, G2 vs. G3 ns) with accordingly lowest additional RF applications in G1 (3.0 ± 2.6 vs. 7.0 ± 5.4 in G2 and 8.4 ± 4.0 in G3; G1 vs. G2 and G3, p < 0.001, G 2 vs. G 3 ns). Sections along ablation lines with low initial CF were most likely to reveal excitability. Single procedure success was 81.9 vs. 73.5 vs. 71.4% (G 1, 2 and 3, p = 0.6) during 437 ± 254 day follow-up. CONCLUSION: Higher tip-to-tissue CF during PVI facilitates the achievement of an unexcitable ablation line, requiring less additional RF-energy.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 29(4): 537-547, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29377448

RESUMO

AIMS: To evaluate the incidence of newly diagnosed intracardiac thrombi (ICT) in respect to the mode of OAC in patients undergoing cardioversion (CV). METHODS AND RESULTS: We prospectively assessed transesophageal echocardiography (TEE) and OAC therapy prior to CV in AF patients with ≥48-hour duration scheduled for CV. A total of 60 first-time ICT (4.7%) were diagnosed in 1,286 TEE, with highest rate in patients without OAC (9.6% vs. OAC 4.1%, P  =  0.009) and an apparently lower rate in nonvitamin K antagonist anticoagulants (NOAC) therapy compared to vitamin K antagonist (VKA) (2.5% vs. 5.3%, P  =  0.02). VKA therapy control 4 weeks prior to CV was overall average (time in therapeutic range 60%) and patients showed more frequently clinical characteristics and TEE parameters associated with risk for ICT. Even among patients with effective OAC therapy (uninterrupted NOAC and VKA therapy with international normalized ratio (INR) ≥2.0 for 3 weeks), ICT occurred in 2.7%, but with no difference between both groups (P  =  0.22). There was no difference between different types of NOAC. Independent predictors for ICT were history of embolism, hypertension, BMI, absence of OAC, renal function, reduced atrial appendage flow, and presence of spontaneous echo contrast. CONCLUSION: NOAC therapy seems favorable in the overall prevention of ICT, although this is likely to be caused by suboptimal VKA therapy control and differences in the overall health status between VKA and NOAC patients. ICT occurred even with effective OAC therapy suggesting individual TEE-guided cardioversion in patients at risk.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Trombose/prevenção & controle , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Ecocardiografia Doppler de Pulso , Ecocardiografia Transesofagiana , Cardioversão Elétrica , Eletrocardiografia , Feminino , Nível de Saúde , Humanos , Incidência , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Fatores de Tempo , Resultado do Tratamento
16.
Europace ; 20(3): 520-527, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28340078

RESUMO

Aims: During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Methods and results: Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Conclusion: Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração/cirurgia , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Seio Aórtico/cirurgia , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Fluoroscopia , Frequência Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/fisiopatologia , Resultado do Tratamento , Função Ventricular Esquerda
17.
Europace ; 20(1): 43-49, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27742775

RESUMO

Introduction: Comparative data of early recurrence rates of atrial fibrillation (ERAF) following second-generation cryoballoon (CB-G2) and radiofrequency current (RFC) ablation for pulmonary vein isolation (PVI) in paroxysmal AF (PAF) are rare. We randomized PAF patients into either PVI with CB-G2 (group 1) or PVI with a combined RFC-approach applying contact force (CF) with the endpoint of unexcitability (group 2) to investigate ERAF. Methods and results: In group 1 (n = 30), CB-G2-PVI was performed. After CF-PVI in group 2 (n = 30), bipolar pacing on the ablation line and additional ablation until unexcitability was conducted. Follow-up included 48 h of in-hospital monitoring followed by 5-day Holter ECGs 1, 2, 3, 6, 12 months postablation to evaluate ERAF. Acute PVI was reached in 100% of group 2 and in 99% of group 1. Shorter procedure durations (98.0 ± 21.9 vs. 114.3 ± 18.7 min, P < 0.05) but extended fluoroscopy times (15.4 ± 3.9 vs. 10.0 ± 4.3 min, P < 0.05) were found in the CB-G2 group. Ten non-severe complications occurred (6 vs. 4 in group 1 and 2, P = 0.73). In group 2, five patients suffered from ERAF vs. seven patients in group 1 (P = 0.67). The time until the occurrence of ERAF was shorter in group 2 (1 day (q1-q3: 1-4.5)) when compared with group 1 (22 (q1-q3: 6-54) days, P = 0.025). Conclusion: ERAF rates were equal among groups; however, they occurred earlier in the initial phase after RFC ablation when compared with CB-G2. PVI utilizing cryoablation is associated with shorter procedure durations but extended fluoroscopy time while being similarly secure.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Fluoroscopia , Alemanha , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Projetos Piloto , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Radiografia Intervencionista , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Mult Scler Relat Disord ; 19: 44-49, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29127856

RESUMO

BACKGROUND: Fingolimod can lead to increased risk of cardiac events such as bradycardia or atrioventricular (AV) block. OBJECTIVE: Evaluate acute and long-term effects of fingolimod on heart rhythm (HR), heart rate variability (HRV) and development of AV-blocks. METHODS: In 64 patients with relapsing-remitting multiple sclerosis Holter ECG monitoring (HEM) and HRV analysis were performed 24h before, six h during and 72h after initiation of fingolimod. We additionally analyzed a 24h HEM after a follow up of ≥ three months. RESULTS: Heart rate (HR) decreased significantly (p < 0.001) under fingolimod treatment with nadir at five hours after starting and maintained decreased for 72h. Five (7.8%) patients suffered from new-onset AV-block requiring cessation of treatment. In four of five patients (80%), the AV-block could only be documented in the 72h-HEM with a median time of occurrence at 14h. The mean heart rate was still significant lower after a mean follow up time of 14.1 ± 9.6 months (85.0 ± 9.8 vs. 75.3 ± 16.2 bpm; p = 0.002) in comparison to baseline. CONCLUSION: The treatment with fingolimod leads to an increase of vagal activation which persists even after 14 months of treatment. These changes did not return to baseline levels on treatment with fingolimod. Based on our data an additional at least 24h hour-HEM after the initiation of fingolimod therapy should be considered.


Assuntos
Cloridrato de Fingolimode/efeitos adversos , Bloqueio Cardíaco/induzido quimicamente , Frequência Cardíaca/efeitos dos fármacos , Imunossupressores/efeitos adversos , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Adulto , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
19.
J Cardiovasc Electrophysiol ; 28(9): 1058-1067, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28597532

RESUMO

BACKGROUND: Ablation of scar-related ventricular tachycardia (VT), especially in noninducible VT or hemodynamically unstable patients, can be challenging. Thus, we evaluated feasibility of an ultra high-density 3-D mapping approach to characterize the ventricular substrate and, if possible, to map VT. METHODS AND RESULTS: Twenty-two patients (67 ± 2 years, mean LV-EF 36 ± 3%) with both ischemic and nonischemic cardiomyopathy and documented VT underwent mapping and catheter ablation using a 64-electrode mini-basket catheter. Substrate characterization included ultra high-density voltage maps, identification of areas of slow conduction and late potentials. Whenever VT was inducible activation mapping was performed. In 13 of 22 patients, the presumed clinical VT (in 16 of 22 any VT) was inducible. A total of 50 maps were generated (22 substrate maps, 28 during VT), mapping time was 33 ± 4 minutes, number of points was 10,937 ± 1,923. Low voltage areas were related with the site of origin in all mapped VT. Isochronal maps indicated areas of slow conduction in 14 of 22 patients, all in border zone scar. In 95% of patients, late potentials were found. Mapping time during VT was 9 ± 2 minutes, number of points 6,740 ± 1,140. Covered cycle length was 82 ± 5% (16 re-entry, 10 focal, and two undetermined). During 4 months follow-up, 90% remained free from VT recurrence. CONCLUSION: Ultra high-density mapping in patients with scar-related VT is feasible, safe and enables detailed insight into tachycardia mechanisms. Critical sites can be identified (1) by precise substrate characterization when VT is not inducible or hemodynamically not tolerated and (2) during short lasting episodes of VT in order to guide catheter ablation.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Cardiomiopatias/complicações , Ablação por Cateter/métodos , Cicatriz/complicações , Frequência Cardíaca/fisiologia , Imageamento Tridimensional/métodos , Taquicardia Ventricular/cirurgia , Idoso , Cardiomiopatias/diagnóstico , Cicatriz/diagnóstico , Eletrocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Curva ROC , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 28(10): 1127-1136, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28635023

RESUMO

INTRODUCTION: The need for transesophageal echocardiography (TEE) before catheter ablation of atrial fibrillation (CA-AF) is still being questioned. The aim of this study is to analyze patients' (patients) risk factors of left atrial appendage thrombus (LAAT) prior to CA-AF in daily clinical practice, according to oral anticoagulation (OAC) strategies recommended by current guidelines. METHODS AND RESULTS: All patients scheduled for CA-AF from 01/2015 to 12/2016 in our center were included and either treated with NOACs (novel-OAC; paused 24-hours preablation) or continuous vitamin K antagonists (INR 2.0-3.0). All patients received a preprocedural TEE at the day of ablation. Two groups were defined: (1) patients without LAAT, (2) patients with LAAT. The incidence of LAAT was 0.78% (13 of 1,658 patients). No LAAT was detected in patients with a CHA2 DS2 -VASc score of ≤1 (n = 640 patients) irrespective of the underlying AF type. Independent predictors for LAAT are: higher CHA2 DS2 -VASc scores (odds ratio [OR] 1.54, 95%-confidence interval [CI]: 1.07-2.23, P = 0.0019), a history of nonparoxysmal AF (OR 7.96, 95%-CI: 1.52-146.64, P = 0.049), hypertrophic cardiomyopathy (HCM; OR 9.63, 95% CI: 1.36-43.05, P = 0.007), and a left ventricular ejection fraction (LVEF) < 30% (OR 8.32, 95% CI: 1.18-36.29, P = 0.011). The type of OAC was not predictive (P = 0.70). CONCLUSIONS: The incidence of LAAT in patients scheduled for CA-AF is low. Therefore, periprocedural OAC strategies recommended by current guidelines seem feasible. Preprocedural TEE may be dispensed in patients with a CHA2 DS2 -VASc score ≤1. However, a CHA2 DS2 -VASc score ≥2, reduced LVEF, HCM, or history of nonparoxysmal AF are independently associated with an increased risk for LAAT.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Ecocardiografia Transesofagiana/métodos , Trombose/diagnóstico por imagem , Idoso , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Fibrilação Atrial/epidemiologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Medicina de Precisão , Valor Preditivo dos Testes , Medição de Risco , Volume Sistólico , Trombose/tratamento farmacológico , Trombose/epidemiologia , Resultado do Tratamento , Vitamina K/antagonistas & inibidores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA