Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Clin Med ; 13(10)2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38792392

RESUMO

Background/Objective: Cardiac magnetic resonance (CMR) is the reference method for right ventricular (RV) volume and function analysis, but time-consuming manual segmentation and corrections of imperfect automatic segmentations are needed. This study sought to evaluate the applicability of an echocardiographically established truncated cone-rhomboid pyramid formula (CPF) for simplified RV quantification using CMR. Methods: A total of 70 consecutive patients assigned to RV analysis using CMR were included. As standard method, the manual contouring of RV-short axis planes was performed for the measurement of end-diastolic volume (EDV) and end-systolic volume (ESV). Additionally, two linear measurements in four-chamber views were obtained in systole and diastole: basal diameters at the level of tricuspid valve (Dd and Ds) and baso-apical lengths from the center of tricuspid valve to the RV apex (Ld and Ls) were measured for the calculation of RV-EDV = 1.21 × Dd2 × Ld and RV-ESV = 1.21 × Ds 2 × Ls using CPF. Results: RV volumes using CPF were slightly higher than those using standard CMR analysis (RV-EDV index: 86.2 ± 29.4 mL/m2 and RV-ESV index: 51.5 ± 22.5 mL/m2 vs. RV-EDV index: 81.7 ± 24.1 mL/m2 and RV-ESV index: 44.5 ± 23.2 mL/m2) and RV-EF was lower (RV-EF: 41.1 ± 13.5% vs. 48.4 ± 13.7%). Both methods had a strong correlation of RV volumes (ΔRV-EDV index = -4.5 ± 19.0 mL/m2; r = 0.765, p < 0.0001; ΔRV-ESV index = -7.0 ± 14.4 mL/m2; r = 0.801, p < 0.0001). Conclusions: Calculations of RV volumes and function using CPF assuming the geometrical model of a truncated cone-rhomboid pyramid anatomy of RV is feasible, with a strong correlation to measurements using standard CMR analysis, and only two systolic and diastolic linear measurements in four-chamber views are needed.

2.
PLoS One ; 18(8): e0290418, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37594956

RESUMO

BACKGROUND: Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in comparison to cardiovascular magnetic resonance (CMR). METHODS: 129 consecutive patients with standard TTE and RV analysis by CMR were included. A formula based on the geometric assumptions of a truncated cone minus a truncated rhomboid pyramid was developed for calculations of RV end-diastolic volume (EDV) and RV end-systolic volume (ESV) by using the basal diameter of the RV (Dd and Ds) and the baso-apical length (Ld and Ls) in apical 4-chamber TTE views: RV EDV = 1.21 * Dd2 * Ld, and RV ESV = 1.21 * Ds2 * Ls. RESULTS: Calculations of RV EDV (ΔRV EDV = 10.2±26.4 ml to CMR, r = 0.889), RV ESV (ΔRV ESV = 4.5±18.4 ml to CMR, r = 0.921) and RV EF (ΔRV EF = 0.5±4.0% to CMR, r = 0.905) with the cone-pyramid formula (CPF) highly agreed with CMR. Impaired RV function on CMR (n = 52) was identified with a trend to higher accuracy by CPF than by conventional echocardiographic parameters (tricuspid annular plane systolic excursion (TAPSE) and fractional area change (FAC)). CONCLUSION: Calculations of RV volumes and RV function by 2D TTE with the newly developed CPF were in high concordance to measurements by CMR. Accuracy for detection of patients with reduced RV function were higher by the proposed 2D TTE CPF method than by conventional echocardiographic parameters of TAPSE and RV FAC.


Assuntos
Músculos do Dorso , Insuficiência Cardíaca , Humanos , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Tratos Piramidais
3.
Am J Cardiol ; 113(11): 1859-66, 2014 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-24837265

RESUMO

This study evaluated 2-dimensional (2D) transthoracic echocardiography (TTE) using Valve Academic Research Consortium-2 (VARC-2) criteria and 3-dimensional (3D) TTE for assessment of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) in comparison with cardiac magnetic resonance (CMR) imaging. In 71 patients, 2D TTE, 3D TTE, and CMR imaging were performed to assess AR severity after TAVI. Using 2D TTE, AR severity was graded according to VARC-2 criteria and regurgitant volume (RVol) was determined. Three-dimensional color Doppler TTE allowed direct planimetry of the vena contracta area of the paravalvular regurgitation jet and calculation of the RVol as product with the velocity-time integral. RVol by CMR imaging was measured by phase-contrast velocity mapping in the ascending aorta. After TAVI, mean RVol determined by CMR imaging was 9.2 ± 9.6 ml/beat and mean regurgitant fraction was 13.3 ± 10.3%. AR was assessed as none or mild in 58 patients (82%) by CMR imaging. Correlation of 3D TTE and CMR imaging on RVol was better than correlation of 2D TTE and CMR imaging (r = 0.895 vs 0.558, p <0.001). There was good agreement between RVol by CMR imaging and by 3D TTE (mean bias = 2.4 ml/beat). Kappa on grading of AR severity was 0.357 between VARC-2 and CMR imaging versus 0.446 between 3D TTE and CMR imaging. Intraobserver variability for analysis of RVol of AR after TAVI was 73.5 ± 52.2% by 2D TTE, 16.7 ± 21.9% by 3D TTE, and 2.2 ± 2.0% by CMR imaging. In conclusion, 2D TTE considering VARC-2 criteria has limitations in the grading of AR severity after TAVI when CMR imaging is used for comparison. Three-dimensional TTE allows quantification of AR with greater accuracy than 2D TTE. Observer variability on RVol after TAVI is considerable using 2D TTE, significantly less using 3D TTE, and very low using CMR imaging.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca/efeitos adversos , Imagem Cinética por Ressonância Magnética/métodos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Prognóstico , Falha de Prótese , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA