Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Photodiagnosis Photodyn Ther ; 47: 104076, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38582390

RESUMO

AIMS: Impact of different post-space disinfectants (Saline, Sodium hypochlorite (NaOCl) followed by ethylene-diamine-tetra-acetic acid (EDTA) and curcumin activated by microbubble emulsion (MBE) on the Vickers hardness (VH) of root canal dentin and extrusion bond strength (EBS) of Glass fiber post (GFP) and PEEK post. METHODS: Ninety maxillary central incisors having fully formed roots were included. After the specimen's disinfection, root canal treatment was completed. Post space was prepared by removing gutta-percha using gates glidden drills. Teeth were then arbitrarily allocated into three groups based on the methods of disinfection regime used. Group 1: Saline, Group 2: NaOCl+ EDTA and Group 3: Curcumin activated by MBE (n = 30). Analysis of VH of radicular dentin was performed using a micro-Vickers tester on ten samples from each group. After post-space disinfection, twenty specimens from each group were further divided into two subgroups (n = 10) In group-1A 2A, and 3A, GFP was used. Whereas, prefabricated PEEK posts were used in 1B, 2B, and 3B subgroups. The PBS and failure modes were performed using a universal testing machine and stereomicroscope respectively. Data was analyzed using ANOVA and Tukey post hoc test to identify significant variations among groups concerning the MH and EBS of the different posts used (p = 0.05). RESULTS: Group 2 (5.25 % NaOCl + 17 % EDTA) (0.15 ± 0.02 GPa) treated specimens presented lowest scores of VH. However, Group 1 (Saline) irrigated canals displayed the highest scores of surface hardness (0.25 ± 0.07 GPa). Additionally, a cervical third of 3A (CP activated by MBE + GFP) (11.22 ± 0.79 MPa) presented the highest scores of bond integrity. Whereas Group 1B (Saline + PEEK post) treated specimens presented the lowest scores of PBS (4.15 ± 0.15 MPa). CONCLUSION: Curcumin activated by microbubble emulsion for disinfection of canal dentin demonstrated favorable VH. Similarly, glass fiber post-cemented in radicular walls disinfected with curcumin activated with MBE showed promising post-bond integrity to the canal dentin.

2.
Photodiagnosis Photodyn Ther ; 45: 103943, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38145770

RESUMO

AIMS: Bleached enamel reversal using antioxidants sodium ascorbate (SA), Green tea extract (GTE), grape seed extract (GSE), Curcumin photosensitizer (CP) and Er: YAG laser on the adhesive strength and marginal leakage of composite material bonded to the bleached enamel surface. MATERIALS AND METHODS: Enamel surface of hundred and twenty sound human first premolar teeth was cleansed using pumice and bleached with 35 % hydrogen peroxide. The samples were randomly divided into 5 groups based on the antioxidants used. n = 20 Group 1 (Control): No antioxidant agent, Group 2: 10 % SA solution, Group 3: 6.5 % GSE, Group 4: 5 % GTE, Group 5: Er: YAG laser and Group 6: CP. Following reversal, the composite was built and cured for 40 s. All the specimens were stored in distilled water at room temperature for 1 day. Microleakage, SBS, and failure mode were analyzed. Kolmogorov-Smirnov test, one-way analysis of variance, and Tukey's multiple post hoc test were used to analyze the data statistically. RESULTS: Group 2 (SA) (20.11 ± 5.79 nm) exhibited minimum value of microleakage and highest SBS (10.22 ± 1.62 MPa). Whereas, Group 1 (No antioxidant agent) displayed maximum scores of marginal leakage (28.11±8.89 nm) and lowest SBS (7.02 ± 1.22 MPa). CONCLUSION: CP, GTE and GSE can be used as a potential alternative to the commonly used SA solution to reverse the negative impact of bleaching on the enamel surface. The use of reversal agents CP, GTE and GSE improves bond values with a decrease in microleakage scores However, future studies are still warranted to conclude the outcomes of the existing study.


Assuntos
Curcumina , Extrato de Sementes de Uva , Fotoquimioterapia , Clareamento Dental , Humanos , Extrato de Sementes de Uva/farmacologia , Curcumina/farmacologia , Chá , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Antioxidantes/farmacologia , Ácido Ascórbico , Ácido Hipocloroso , Esmalte Dentário
3.
Photodiagnosis Photodyn Ther ; 42: 103571, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37062512

RESUMO

AIMS: Evaluation of survival of S.mutans and shear bond strength (SBS) of adhesive restorative material bonded to carious affected dentin (CAD) after using cavity disinfectant i.e., Er, Cr: YSGG (ECYL), (Nd: YAG) (NYL), Malachite green (MG), Ocimum sanctum (OS) in comparison to the conventional control chlorhexidine gluconate (CHX). MATERIALS AND METHODS: Seventy-five caries-affected mandibular third molars having ICDAS scores 4 and 5 were included. Carious infected dentin was eliminated and CAD surface was obtained. On twenty-five samples, an uncontaminated suspension of S. mutans strain ATCC 35,668 in Brain-Heart Infusion broth (BHI) was obtained after 12 h of incubation at 37 °C. Based on the disinfection regime used to sterilize the CAD surface, all the specimens were allocated into five different groups. (n = 15) Group 1: CAD disinfected with CHX, Group 2: CAD disinfected with ECYL, Group 3: CAD disinfected with NYL, Group 4: CAD disinfected with MG, and Group 5: CAD disinfected with OS. An assessment of the survival rate of S. mutans was performed. Fifty specimens were smeared with single-step adhesive bond followed by restoring the CAD surface using packable composite. SBS and failure mode were determined using a universal testing machine and stereomicroscope at 40x magnification. ANOVA and post-hoc Tukey-Kramer test was used for data analysis p = 0.05. RESULTS: Group 1: CHX-treated specimens displayed the lowest bacterial viability (0.11±0.03 CFU/mL). However, group 4: MG exhibited the highest bacterial survival (0.15 ± 0.09 CFU/mL). The highest and lowest SBS of resin adhesive bonded to disinfected CAD surface were exhibited by (group 5: OS) (21.48±1.39 MPa) and (group 3: NYL) (16.41±0.90 MPa) respectively (p>0.05). CONCLUSION: Ocimum sanctum seems to be promising in terms of its antibacterial efficacy against S.mutans and positive impact on SBS of resin adhesive to CAD surface.


Assuntos
Desinfetantes , Lasers de Estado Sólido , Fotoquimioterapia , Desinfecção , Ocimum sanctum , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Teste de Materiais , Dentina/química
4.
Photodiagnosis Photodyn Ther ; 42: 103538, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37001714

RESUMO

AIMS: Evaluation of antimicrobial efficacy of contemporary disinfection Malachite green (MG), Terminalia chebula (T. chebula), and Indocyanine green (ICG)) against E. faecalis and their effect on push-out bond strength (PBS) of glass fiber post (GFP) bonded to root dentin in comparison to conventional irrigation used (Sodium hypochlorite (NaOCl) + Ethylene diamine tetraacetic acid (17% EDTA). MATERIALS AND METHODS: Root canal treatment was initiated on sixty human single-rooted premolars and working length was established. The canals were enlarged using ProTaper universal system till F3. The prepared canals were obturated with Gutta-percha (GP) and AH Plus sealer followed by post-space preparation. Twenty canals contained a standard strain of E. faecalis (n=5 in each group) cultured overnight at 37 °C in BHI broth. All the samples were randomly allocated into four groups based on post-space irrigation. (n = 10) Group 1: 5.25% NaOCl+17% EDTA (Control), Group 2: 5.25% NaOCl + ICG, Group 3: 5.25% NaOCl + MG and Group 4: 5.25% NaOCl + T. chebula. Survival rates of E. faecalis were evaluated on the twenty specimens. GFP was placed on the remaining samples using self-etch dual-cure pastes and sectioning was performed in 1 mm thick slices. PBS and failure mode were analyzed using a universal testing machine and stereomicroscope. One-way analysis of variance (ANOVA) and Tukey multiple comparison t-tests were used for data analysis. (p = 0.05). RESULTS: 5.25% NaOCl+17% EDTA demonstrated (0.11±0.01 CFU/mL) the lowest survival rate of E. faecalis. However, Group 2 (5.25% NaOCl + ICG) exhibited the highest survival rate (0.52 ± 0.10). Furthermore, the coronal third of group 4 (5.25% NaOCl + T. chebula) (8.71±0.25 MPa) specimens demonstrated the highest PBS of GFP. However, an apical section of group 2 samples (5.25% NaOCl + ICG) (1.21±0.71 MPa) displayed the lowest outcome of bond integrity. CONCLUSION: Terminalia chebula when used as a final canal disinfectant seems to be promising in improving canal sterility and the bond strength of GFP to the root dentin.


Assuntos
Desinfetantes , Fotoquimioterapia , Materiais Restauradores do Canal Radicular , Terminalia , Humanos , Cavidade Pulpar , Dentina , Desinfetantes/farmacologia , Ácido Edético/farmacologia , Resinas Epóxi , Verde de Indocianina/farmacologia , Teste de Materiais , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Irrigantes do Canal Radicular/farmacologia , Irrigantes do Canal Radicular/uso terapêutico , Preparo de Canal Radicular
5.
Photodiagnosis Photodyn Ther ; 39: 102970, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35718106

RESUMO

AIM: The present study aims to evaluate the bond integrity of composite restoration bonded to CAD after disinfection using pineapple peel extract (PPE) Diode laser (DL) and riboflavin (RF) activated by photodynamic therapy (PDT). MATERIAL AND METHODS: Forty human permanent mandibular molars were collected, disinfected, and mounted in poly-vinyl pipes. Carious infected dentin was removed and CAD was disinfected. Samples were divided into 4 groups based on disinfection. Group 1: CAD disinfected with CHX; group 2: CAD disinfected with diode laser; CAD disinfected with PPE and CAD sterilized with riboflavin. Following disinfection, CAD surfaces were applied with the etch-and-rinse adhesive system and bonding agent and restored with a composite restoration. Samples were placed in a thermocycler to simulate oral aging and then mounted on the universal testing machine (UTM) for shear bond strength (SBS) testing. Failure mode was assessed using a steriomicroscoscope at 40X magnification. One-way analysis of variance (ANOVA) compared the mean SBS and failure type obtained to identify intergroup differences. Similarly, for multiple group comparison, the Tukey HSD test was used keeping the level of significance at 0.05. RESULTS: CAD disinfected with chlorhexidine (CHX) established the highest bond integrity of the restoration. However, group 2 CAD disinfected with DL displayed the lowest bond values. It was also observed that dentin disinfected using CHX demonstrated comparable SBS values to CAD disinfected with PPE and CAD disinfected with RF. CONCLUSION: RF and PPE displayed comparable outcomes of SBS of composite restoration bonded to CAD to that of CHX. DL displayed lower bond integrity than the other investigated groups. Further studies are recommended to deduce the findings of the existing study.


Assuntos
Adesivos , Fotoquimioterapia , Clorexidina/farmacologia , Suscetibilidade à Cárie Dentária , Dentina , Desinfecção , Humanos , Lasers Semicondutores , Teste de Materiais , Fotoquimioterapia/métodos , Riboflavina/farmacologia
6.
J Appl Biomater Funct Mater ; 18: 2280800020924514, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33356766

RESUMO

OBJECTIVE: The aim of this study was to evaluate marginal fit of yttrium tetragonal zirconia polycrystals (Y-TZP)' copings with different finish line designs fabricated with various digital scanners and milling systems. METHODS: Three model plastic teeth were prepared with three finish line designs: Design-1, continuous chamfer; Design-2, chamfer with shallow depression; Design-3, chamfer with deep depression. The "master models" were replicated using elastomeric polyvinyl siloxane impression material and poured in type IV stone generating 90 dies, 30 dies for each design. Dies were scanned and copings were milled utilizing three digital scanners and computer-aided design/computer-aided manufacturing (CAD/CAM) systems: System-1, InEos Red Scan (Sirona Dental Systems, Germany), Vitablocks® Mark II (VITA, Germany) copings milled by Cerec® inLab (Sirona Dental Systems, Germany); System-2, Cerec® AC Connect with BlueCam (Sirona Dental Systems, Germany), Vitablocks® Mark II (VITA, Germany) copings milled by Cerec® inLab (Sirona Dental Systems, Germany); and System-3, NobleProcera™ Optical Scanner (NobleBiocare™), procera zirconia coping milled by a Noble Procera™ milling machine (NobleBiocare™). Copings were seated on their respective "master models" and secured with uniform force. Eight measurements per coping were performed at pre-established points, with a metallurgical microscope (Zeiss, Germany) connected to a high precision digital video-micrometer (Javelin JV6000, California, USA) at 200 × magnification. RESULTS: The tested systems demonstrated marginal gaps ranging from 12.4 to 26.6 µm. Results for marginal fit of milled copings fabricated using three systems with different finish line designs differed significantly (p < 0.05). Procera zirconia copings scanned and milled with NobleProcera™ exhibited significantly lower marginal gaps compared to other specimen groups. However, InEos Red Scan/Vitablocks® Mark II/Cerec® inLab showed maximum marginal gaps among the study specimens. CONCLUSIONS: CAD-CAM manufactured Y-TZP' copings exhibited marginal gaps ranging from 12.49 to 26.6 µm. The CAD-CAM fabrication system was a significant factor influencing the marginal misfit of Y-TZP' copings. Margin design exhibited system dependent influence on the marginal misfit. Marginal misfit observed for all systems were within clinically acceptable parameters.


Assuntos
Planejamento de Prótese Dentária , Ítrio/química , Zircônio/química , Desenho Assistido por Computador , Adaptação Marginal Dentária , Porcelana Dentária/química , Ligas Metalo-Cerâmicas/química , Modelos Dentários , Titânio/química
7.
Photodiagnosis Photodyn Ther ; 31: 101875, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32534249

RESUMO

AIM: To evaluate the adhesive bond integrity (shear bond strength-SBS) of composite resin bonded to carious dentin using chlorhexidine gluconate (CHX), Er,Cr:YSGG laser (ECYL) and photodynamic therapy (PDT). MATERIAL AND METHODS: Thirty carious and ten non-carious mandibular teeth were collected through non-traumatic extraction. All samples were embedded in polyvinyl cross-sections to the cemento-enamel junction. The preparation of caries-affected dentin was performed by grinding the specimens using silicon carbide discs. All specimens were randomly allocated in to four groups (n = 10). Group 1, non-affected dentin with no disinfection; Group 2, caries affected dentin treated with 2% CHX; Group 3, affected dentin disinfected with PDT [100 mg/L methylene blue solution (MBS) and Diode laser]; Group 4, affected dentin treated with ECYL. Self-etch adhesive was smeared on all specimens for 10 s and photopolymerized for 10 s. All specimens were placed in an incubator with humid environment for 24 h at 37 °C followed by positioning in universal testing machine for SBS testing. Failure mode examination of debonded samples was performed by a stereomicroscope. Analysis of variance (ANOVA) was used for inter group comparison through mean and standard deviation of each group. For multiple group comparison Tukey HSD was employed. Level of significance was established at p < 0.05. RESULTS: The highest SBS value was observed in group 1 (24.98 ± 1.59 MPa). Whereas, the lowest bond strength was displayed by group 3 (14.22 ± 1.40 MPa) specimens. Lased dentin in group 4 (15.89 ± 3.22 MPa) exhibited SBS values comparable to group 3 (14.22 ± 1.40 MPa). Group 2 (CHX-18.25 ± 1.29 MPa) exhibited statistically significant difference compared to all experimental groups (p < 0.05). CONCLUSIONS: Adhesive bond strength of disinfected carious dentin was higher with CHX treatment as compared to Photodynamic therapy and Er,Cr: YSGG laser treatment. Carious dentin showed lower bond strength to composite resin as compared to non-carious dentin.


Assuntos
Lasers de Estado Sólido , Fotoquimioterapia , Adesivos , Clorexidina , Suscetibilidade à Cárie Dentária , Dentina , Lasers de Estado Sólido/uso terapêutico , Teste de Materiais , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico
8.
J Appl Biomater Funct Mater ; 18: 2280800020910954, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32421423

RESUMO

AIM: The aim of the study was to investigate the shear bond strength (SBS) and compressive strength (CS) of Er Cr YSGG laser (ECL) treated, re-bonded lithium disilicate (LD) ceramic in comparison to standard conventional conditioning (hydrofluoric acid (HFA) and silane). METHODS: One hundred LD ceramic disks were divided equally for SBS and CS testing. Eighty samples were conventionally surface treated and bonded to resin cement followed by de-bonding of the cement build-up. All de-bonded specimens were divided into four groups based on re-bonding surface treatments (HFA, primer, adhesive, and ECL). Resin cement build-ups were performed in 40 specimens for SBS testing (universal testing machine); however, the remaining 40 specimens were tested for CS. Ten specimens each were used as controls (surface treatment was performed once and no primary resin cement bonding) for SBS and CS assessment. Surface topography was assessed using a scanning electron microscope. RESULTS: The maximum and minimum SBS values were shown by groups: control (33.42 ± 3.28 megapascals (MPa)); and ECL (17.50 ± 2.22 MPa) respectively. The maximum and minimum CSs were displayed by specimens in the ECL group (439.45 ± 70.68 MPa) and the control group (237.28 ± 19.96 MPa), respectively. For ECL specimens, SBS was significantly lower and CS was significantly higher as compared to control specimens. CONCLUSIONS: Application of the Er Cr YSGG laser significantly improved the CS of de-bonded ceramic specimens. However, it did not show a positive influence on the bond integrity of re-bonded ceramics in comparison to conventional surface treatment regimes.


Assuntos
Cerâmica/química , Força Compressiva/efeitos da radiação , Lasers de Estado Sólido , Porcelana Dentária/química , Ácido Fluorídrico/química , Cimentos de Resina/química , Silanos/química , Propriedades de Superfície
9.
Photodiagnosis Photodyn Ther ; 31: 101805, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32404299

RESUMO

BACKGROUND: To evaluate the effect of different photosensitizer on extrusion bond strength of glass fiber post to radicular dentin. MATERIAL AND METHODS: Forty maxillary and mandibular central incisors were disinfected and decoronated. Mechanical instrumentation of canal was performed using protaper NiTi. Shaping and cleaning of canal comprised of S1, S2, SX with finishing files F1 and F2, followed by continuous irrigation. Canals were dried and obturated with gutta percha. Peso reamers were used to prepare post space. Based on the photosensitizers (PS) used, the samples were divided into three groups (n = 10). Group 1: treated with methylene blue photosensitizer (MBP) at 50 mg/l, Group 2: Curcumin photosensitizer (CP) at 500 mg/l, Group 3: canal space was filled with Toluidine blue photosensitizer (TB) at 100 mg/l. All photosensitizers were activated using different lasers. The samples in group 4 (control) were irrigated using 5.25% sodium hypochlorite (NaOCl) + 17% ethylenediamine tetra acetic acid (EDTA). Posts were cemented and teeth were sectioned into coronal, middle and apical sections. All sections were placed in universal testing machine to evaluate extrusion bond strength in megapascal (MPa). Fracture pattern analysis of samples were seen under stereomicroscope at 50x magnification and categorized into adhesive, cohesive and admixed. Assessment of extrusion bond strength was performed by one-way analysis of variance (ANOVA) and Tukey multiple comparison test (p = 0.05). RESULTS: The highest bond strength was achieved in group 2, including samples treated with curcumin photosensitizer (CP) at all three root levels; cervical (9.01 ±â€¯1.62 MPa), middle (7.95 ±â€¯0.75 MPa) and apical (5.81 ±â€¯0.15 MPa). Whereas, the lowest extrusion bond strength was observed in group 4 (canal irrigated with conventional 5.25% NaOCl +17% EDTA) at coronal (6.10 ±â€¯1.77 MPa), middle (5.11 ±â€¯0.75 MPa) and apical one-thirds (3.65 ±â€¯0.14 MPa). Intra group comparison revealed decrease in extrusion bond strength from coronal to apical direction. Moreover, both group 2 and group 3 showed statistically significant difference to samples in control group and group 1. (p < 0.05). CONCLUSION: TB and CP at concentration of 100 mg/l and 500 mg/l has the potential to be used as an alternate to conventional cleaning regime. TB and CP at this concentration when activated with PDT is likely to improve extrusion bond values.


Assuntos
Fotoquimioterapia , Fármacos Fotossensibilizantes , Dentina , Guta-Percha , Teste de Materiais , Fotoquimioterapia/métodos
10.
J Appl Biomater Funct Mater ; 18: 2280800020905768, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32297822

RESUMO

OBJECTIVE: The aim was to compare restorative marginal integrity of ceramic crowns luted with bioactive and resin cements using micro-computed tomography (micro-CT) microleakage evaluations and bond strength assessment. METHODS: Thirty molar teeth were prepared by sectioning and polishing for dentin exposure for resin cement build-ups. Teeth were randomly divided among three groups of cements: (1) bioactive (ACTIVA); (2) glass ionomer cement (GIC; Ketac Cem); and (3) resin luting agent (Nexus 3). Bonding regime and build-ups (4 mm × 2 mm) were performed using the recommended protocol. For microleakage assessment, 30 premolar teeth were prepared for dentin-bonded crowns using lithium disilicate ceramic and the computer-aided design and computer-aided manufacturing technique. Crowns were cemented with standard load, cement amount, and duration using three cements (Group A: bioactive; Group B: GIC; Group C: resin) and photopolymerized. Cemented crowns were evaluated for volumetric infiltration using micro-CT (Skyscan, Bruker 1173- at 86 kV, 93 µA, 620 ms) after immersion in 50% solution of silver nitrate (AgNO3) (24 hours). Shear bond strength (SBS) was assessed by fracture of cement build-ups at a cross-head speed of 0.5 mm/min in a universal testing machine. RESULTS: Mean SBS among bioactive (21.54 ± 3.834 MPa) specimens was significantly higher than that for GIC (14.08 ± 3.25 MPa) specimens (p < 0.01), but they were comparable to resin samples (p > 0.05) (24.73 ± 4.32 MPa). Microleakage was significantly lower in crowns luted with bioactive (0.381 ± 0.134) cement compared to GIC (1.057 ± 0.399 mm3) (p < 0.01) and resin (0.734 ± 0.166 mm3) (p = 0.014) cemented crowns. The type of luting agent had a significant influence on the microleakage of crowns and bond strength to dentin (p < 0.05). CONCLUSION: Bioactive cement exhibited less microleakage and comparable SBS to resin luting agents in in vitro conditions.


Assuntos
Dentina/química , Teste de Materiais , Cimentos de Resina/química , Coroa do Dente/química , Humanos , Técnicas In Vitro , Resistência ao Cisalhamento , Nitrato de Prata/química , Microtomografia por Raio-X
11.
Bosn J Basic Med Sci ; 20(4): 438-444, 2020 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-32216743

RESUMO

Dental pulp cells (DPCs) represent good candidates for the regeneration of dental tissue. This study aimed to evaluate the growth and differentiation potential of DPCs cultured inside demineralized dentin tubules in vivo. Six green fluorescent protein-transgenic rats (body weight 100 g each) and thirty-two Sprague-Dawley (SD) male rats (body weight 250 g each) were used for DPC collection and dentin tubules preparation and transplantation, respectively. Third-passage DPCs with or without collagen gels were loaded into demineralized dentin tubules. Both types of grafts were transplanted into the rectus abdominis muscles of SD rats and were harvested after 21 days. The expression of alkaline phosphatase (ALP), bone sialoprotein (BSP), osteopontin (OPN), nestin, and dentin sialoprotein (DSP) was analyzed by immunohistochemistry. Histological analysis showed that DPCs in the collagen gel formed an osteodentin-like hard tissue matrix after 21 days. Increased positive immunoreactivity for ALP, BSP, OPN, nestin, and DSP was observed in experimental groups compared with control. Our results demonstrate that DPCs in collagen gel inside demineralized dentin tubules show increased growth and differentiation.


Assuntos
Colágeno Tipo I/química , Polpa Dentária/química , Dentina/química , Fosfatase Alcalina/metabolismo , Animais , Animais Geneticamente Modificados , Técnicas de Cultura de Células , Diferenciação Celular , Colágeno/química , Proteínas da Matriz Extracelular/química , Proteínas de Fluorescência Verde/metabolismo , Imuno-Histoquímica , Sialoproteína de Ligação à Integrina/metabolismo , Masculino , Nestina/metabolismo , Odontoblastos/metabolismo , Osteogênese , Osteopontina/metabolismo , Fosfoproteínas/química , Ratos , Ratos Sprague-Dawley , Sialoglicoproteínas/química , Pesquisa Translacional Biomédica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA