RESUMO
Smeed's equation is a widely used model for prediction of traffic fatalities but has been inadequate for use in developing countries. We applied regression analysis to time-series data on vehicles, exponential models for fatality prediction, producing an average absolute error of 20.9% for Qatar, 10.9% for population and traffic fatalities in the United Arab Emirates (UAE), Jordan and Qatar. The data were fitted to Jordan and 5.5% for the UAE. We found a strong linear relationship between gross domestic product and fatality rate.
Assuntos
Acidentes de Trânsito/mortalidade , Automóveis/estatística & dados numéricos , Países em Desenvolvimento/economia , Desenvolvimento Econômico/tendências , Crescimento Demográfico , Análise de Regressão , Acidentes de Trânsito/tendências , Viés , Causas de Morte , Humanos , Jordânia/epidemiologia , Análise dos Mínimos Quadrados , Modelos Lineares , Vigilância da População , Valor Preditivo dos Testes , Catar/epidemiologia , Emirados Árabes Unidos/epidemiologiaRESUMO
Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH, and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure, and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94%, and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m2. As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about 1.82 million US dollars (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture.