Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38423706

RESUMO

Avanafil is an oral medication used to treat erectile dysfunction (ED). As a phosphodiesterase type 5 (PDE5) inhibitor, it functions by inhibiting the PDE5 enzyme, which ultimately results in increased levels of cyclic guanosine monophosphate (cGMP) and improved blood flow to the penis. Approved by the FDA in 2012, avanafil is recognised for its rapid onset of action, short half-life, and favourable side-effects profile. While it has been explored for other potential therapeutic applications, its current approved use is limited to ED and should be used as prescribed by a medical professional. This chapter provides a comprehensive review of avanafil, encompassing its nomenclature, physicochemical properties, methods of preparation, and identification. Various techniques for analysing avanafil, such as electrochemical analysis, spectrophotometric, spectrofluorimetric, and chromatographic techniques, are discussed. The pharmacology of avanafil, including its pharmacokinetics and pharmacodynamics, is also examined.


Assuntos
Disfunção Erétil , Masculino , Humanos , Disfunção Erétil/tratamento farmacológico , Inibidores da Fosfodiesterase 5/farmacologia , Inibidores da Fosfodiesterase 5/uso terapêutico , Pirimidinas/farmacologia , Pirimidinas/uso terapêutico , Hemodinâmica
2.
Int J Anal Chem ; 2015: 210503, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26880920

RESUMO

An impressively simple and precise spectrofluorimetric procedure was established and validated for ponatinib (PTB) quantitation in biological fluids such as human plasma and human urine. This method depends on examining the fluorescence characteristics of PTB in a micellar system of Cremophor RH 40 (Cr RH 40). Cr RH 40 enhanced the intrinsic fluorescence of PTB distinctly in aqueous water. The fluorescence spectra of PTB was recorded at 457 nm following its excitation at 305 nm. Maximum fluorescence intensity was attained by addition of 0.7 mL of Cr RH 40 and one mL of phosphate buffer to PTB aliquots and then dilution with distilled water. There is a linear relationship between the fluorescence intensity of PTB and its concentration over the range 5-120 ngmL(-1), with limit of detection and limit of quantification equal to 0.905 ngmL(-1) and 2.742 ngmL(-1), respectively. The accuracy and the precisions of the proposed method were checked and gave adequate results. The adopted method was applied with a great success for PTB quantitation in different biological matrices (spiked human plasma and urine) giving high recovery values.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA