Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Methodist Debakey Cardiovasc J ; 20(1): 14-17, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38618608

RESUMO

Giant coronary artery aneurysm (GCA) is a rare disease afflicting 0.2% of the population. It is primarily attributed to atherosclerosis in adults and Kawasaki disease in children. Other uncommon etiologies include Takayasu arteritis and post-percutaneous coronary intervention.1,2 GCA lacks a universally accepted definition, with proposed criteria including a diameter exceeding 2 cm, 5 cm, or four times the normal vessel size.3 While the majority of GCAs are asymptomatic, a subset of patients present with angina, myocardial infarction from embolization or compression, heart failure due to fistula formation, or even sudden death.1 We report a case of an adult harboring a GCA involving the right coronary artery.


Assuntos
Aterosclerose , Aneurisma Coronário , Adulto , Criança , Humanos , Vasos Coronários , Dor , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/etiologia , Aneurisma Coronário/terapia , Extremidade Superior
2.
JAMA Neurol ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436973

RESUMO

Importance: Stroke is a leading cause of death and disability in the US. Accurate and updated measures of stroke burden are needed to guide public health policies. Objective: To present burden estimates of ischemic and hemorrhagic stroke in the US in 2019 and describe trends from 1990 to 2019 by age, sex, and geographic location. Design, Setting, and Participants: An in-depth cross-sectional analysis of the 2019 Global Burden of Disease study was conducted. The setting included the time period of 1990 to 2019 in the US. The study encompassed estimates for various types of strokes, including all strokes, ischemic strokes, intracerebral hemorrhages (ICHs), and subarachnoid hemorrhages (SAHs). The 2019 Global Burden of Disease results were released on October 20, 2020. Exposures: In this study, no particular exposure was specifically targeted. Main Outcomes and Measures: The primary focus of this analysis centered on both overall and age-standardized estimates, stroke incidence, prevalence, mortality, and DALYs per 100 000 individuals. Results: In 2019, the US recorded 7.09 million prevalent strokes (4.07 million women [57.4%]; 3.02 million men [42.6%]), with 5.87 million being ischemic strokes (82.7%). Prevalence also included 0.66 million ICHs and 0.85 million SAHs. Although the absolute numbers of stroke cases, mortality, and DALYs surged from 1990 to 2019, the age-standardized rates either declined or remained steady. Notably, hemorrhagic strokes manifested a substantial increase, especially in mortality, compared with ischemic strokes (incidence of ischemic stroke increased by 13% [95% uncertainty interval (UI), 14.2%-11.9%]; incidence of ICH increased by 39.8% [95% UI, 38.9%-39.7%]; incidence of SAH increased by 50.9% [95% UI, 49.2%-52.6%]). The downturn in stroke mortality plateaued in the recent decade. There was a discernible heterogeneity in stroke burden trends, with older adults (50-74 years) experiencing a decrease in incidence in coastal areas (decreases up to 3.9% in Vermont), in contrast to an uptick observed in younger demographics (15-49 years) in the South and Midwest US (with increases up to 8.4% in Minnesota). Conclusions and Relevance: In this cross-sectional study, the declining age-standardized stroke rates over the past 3 decades suggest progress in managing stroke-related outcomes. However, the increasing absolute burden of stroke, coupled with a notable rise in hemorrhagic stroke, suggests an evolving and substantial public health challenge in the US. Moreover, the significant disparities in stroke burden trends across different age groups and geographic locations underscore the necessity for region- and demography-specific interventions and policies to effectively mitigate the multifaceted and escalating burden of stroke in the country.

3.
J Nucl Cardiol ; 32: 101810, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38286326

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) is the non-invasive gold standard for non-invasively determining left ventricular volumes (LVVs) and ejection fraction (EF). We aimed to assess the accuracy of LVV and left ventricular ejection fraction measured by positron emission tomography (PET) as compared to CMR. METHODS: Patients who underwent both PET and CMR within 1 year were identified from prospective institutional registries. Analysis was performed to evaluate the agreement between the raw and body-surface-area-normalized left ventricular volume (LVV) and EF derived from PET vs. those derived from CMR. RESULTS: The study population consisted of 669 patients (mean age 62 ± 13 years, 65% male). The median (interquartile range [IQR]) duration between CMR and PET imaging was 36 (7-118) days. The median (IQR) EF values were 52% (38-63%) on CMR and 53% (37-65%) on PET (mean difference: 0.53% ± 9.1, P = 0.129) with a strong correlation (Spearman rho = 0.84, P < 0.001; Intraclass Correlation Coefficient 0.84, 95% confidence interval [CI]: 0.82-0.86, P < 0.001; Lin's concordance correlation coefficient was 0.844, 95% CI: 0.822 to 0.865). Results were similar with LVV, normalized LVV/EF, and in subgroups of patients with reduced EF, coronary artery disease scar, and LV hypertrophy as well as in patients with defibrillators. However, PET tended to underestimate LVV compared to CMR. CONCLUSION: Our analysis showed a strong correlation of EF and LVV by PET against a reference standard of CMR, whereas PET significantly underestimated LVV, but not EF, compared to CMR.


Assuntos
Rubídio , Função Ventricular Esquerda , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons , Ventrículos do Coração/diagnóstico por imagem , Espectroscopia de Ressonância Magnética
4.
Ear Hear ; 45(1): 257-267, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37712826

RESUMO

OBJECTIVES: This article describes key data sources and methods used to estimate hearing loss in the United States, in the Global Burden of Disease study. Then, trends in hearing loss are described for 2019, including temporal trends from 1990 to 2019, changing prevalence over age, severity patterns, and utilization of hearing aids. DESIGN: We utilized population-representative surveys from the United States to estimate hearing loss prevalence for the Global Burden of Disease study. A key input data source in modeled estimates are the National Health and Nutrition Examination Surveys (NHANES), years 1988 to 2010. We ran hierarchical severity-specific models to estimate hearing loss prevalence. We then scaled severity-specific models to sum to total hearing impairment prevalence, adjusted estimates for hearing aid coverage, and split estimates by etiology and tinnitus status. We computed years lived with disability (YLDs), which quantifies the amount of health loss associated with a condition depending on severity and creates a common metric to compare the burden of disparate diseases. This was done by multiplying the prevalence of severity-specific hearing loss by corresponding disability weights, with additional weighting for tinnitus comorbidity. RESULTS: An estimated 72.88 million (95% uncertainty interval (UI) 68.53 to 77.30) people in the United States had hearing loss in 2019, accounting for 22.2% (20.9 to 23.6) of the total population. Hearing loss was responsible for 2.24 million (1.56 to 3.11) YLDs (3.6% (2.8 to 4.7) of total US YLDs). Age-standardized prevalence was higher in males (17.7% [16.7 to 18.8]) compared with females (11.9%, [11.2 to 12.5]). While most cases of hearing loss were mild (64.3%, 95% UI 61.0 to 67.6), disability was concentrated in cases that were moderate or more severe. The all-age prevalence of hearing loss in the United States was 28.1% (25.7 to 30.8) higher in 2019 than in 1990, despite stable age-standardized prevalence. An estimated 9.7% (8.6 to 11.0) of individuals with mild to profound hearing loss utilized a hearing aid, while 32.5% (31.9 to 33.2) of individuals with hearing loss experienced tinnitus. Occupational noise exposure was responsible for 11.2% (10.2 to 12.4) of hearing loss YLDs. CONCLUSIONS: Results indicate large burden of hearing loss in the United States, with an estimated 1 in 5 people experiencing this condition. While many cases of hearing loss in the United States were mild, growing prevalence, low usage of hearing aids, and aging populations indicate the rising impact of this condition in future years and the increasing importance of domestic access to hearing healthcare services. Large-scale audiometric surveys such as NHANES are needed to regularly assess hearing loss burden and access to healthcare, improving our understanding of who is impacted by hearing loss and what groups are most amenable to intervention.


Assuntos
Auxiliares de Audição , Perda Auditiva , Zumbido , Masculino , Feminino , Humanos , Estados Unidos/epidemiologia , Prevalência , Carga Global da Doença , Zumbido/epidemiologia , Anos de Vida Ajustados por Deficiência , Inquéritos Nutricionais , Saúde Global , Perda Auditiva/epidemiologia , Anos de Vida Ajustados por Qualidade de Vida
6.
PLoS One ; 18(11): e0291451, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37967112

RESUMO

BACKGROUND: Machine learning (ML) has shown promise in improving the risk prediction in non-invasive cardiovascular imaging, including SPECT MPI and coronary CT angiography. However, most algorithms used remain black boxes to clinicians in how they compute their predictions. Furthermore, objective consideration of the multitude of available clinical data, along with the visual and quantitative assessments from CCTA and SPECT, are critical for optimal patient risk stratification. We aim to provide an explainable ML approach to predict MACE using clinical, CCTA, and SPECT data. METHODS: Consecutive patients who underwent clinically indicated CCTA and SPECT myocardial imaging for suspected CAD were included and followed up for MACEs. A MACE was defined as a composite outcome that included all-cause mortality, myocardial infarction, or late revascularization. We employed an Automated Machine Learning (AutoML) approach to predict MACE using clinical, CCTA, and SPECT data. Various mainstream models with different sets of hyperparameters have been explored, and critical predictors of risk are obtained using explainable techniques on the global and patient levels. Ten-fold cross-validation was used in training and evaluating the AutoML model. RESULTS: A total of 956 patients were included (mean age 61.1 ±14.2 years, 54% men, 89% hypertension, 81% diabetes, 84% dyslipidemia). Obstructive CAD on CCTA and ischemia on SPECT were observed in 14% of patients, and 11% experienced MACE. ML prediction's sensitivity, specificity, and accuracy in predicting a MACE were 69.61%, 99.77%, and 96.54%, respectively. The top 10 global predictive features included 8 CCTA attributes (segment involvement score, number of vessels with severe plaque ≥70, ≥50% stenosis in the left marginal coronary artery, calcified plaque, ≥50% stenosis in the left circumflex coronary artery, plaque type in the left marginal coronary artery, stenosis degree in the second obtuse marginal of the left circumflex artery, and stenosis category in the marginals of the left circumflex artery) and 2 clinical features (past medical history of MI or left bundle branch block, being an ever smoker). CONCLUSION: ML can accurately predict risk of developing a MACE in patients suspected of CAD undergoing SPECT MPI and CCTA. ML feature-ranking can also show, at a sample- as well as at a patient-level, which features are key in making such a prediction.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Constrição Patológica , Prognóstico , Angiografia Coronária/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Angiografia por Tomografia Computadorizada/métodos , Aprendizado de Máquina , Valor Preditivo dos Testes
7.
medRxiv ; 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37961713

RESUMO

Impaired microvascular and vasomotor function is a common consequence of aging, diabetes, and other risk factors, and is associated with adverse cardiac outcomes. Such impairments are not readily identified by standard clinical methods of cardiovascular testing such as coronary angiography and noninvasive single photon emission tomography (SPECT) myocardial perfusion imaging (MPI). We hypothesized that signals embedded within stress electrocardiograms (ECGs) identify individuals with microvascular and vasomotor dysfunction. Methods: We developed and validated a novel convolutional neural network (CNN) using stress and rest ECG data (ECG-Flow) to identify patients with impaired myocardial flow reserve (MFR) on quantitative positron emission tomography (PET) MPI (N=3887). Diagnostic accuracy was validated with an internal holdout set of patients undergoing stress PET MPI (N=963). The prognostic association of ECG-Flow with mortality was then evaluated in a separate cohort of patients undergoing SPECT MPI (N=5102). Results: ECG-Flow achieved good diagnostic accuracy for impaired MFR in the holdout PET cohort (AUC, sensitivity, specificity: 0.737, 71.1%, 65.7%). Abnormal ECG-Flow was found to be significantly associated with mortality in both PET holdout and SPECT MPI cohorts (adjusted HR 2.12 [95 ρ CI 1.45, 2.10], ρ = 0.0001, and 2.07 [1.82, 2.36], ρ < 0.0001, respectively). Conclusion: Signals predictive of microvascular and vasomotor dysfunction are embedded in stress ECG waveforms. These signals can be identified by deep learning methods and are related to prognosis in patients undergoing both stress PET and SPECT MPI.

8.
Atherosclerosis ; 382: 117280, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37742396

RESUMO

BACKGROUND AND AIMS: Positron Emission Tomography (PET)-derived myocardial flow reserve (MFR) has been shown to have a role in the diagnosis and prognosis of patients with coronary artery disease (CAD). We performed a systematic review and meta-analysis to summarize the body of literature and synthesize the evidence on the prognostic role of PET-derived MFR in patients with known or suspected CAD. METHODS: A comprehensive literature search of the Medline database from its inception to August 2023, in humans, in any language, was conducted for clinical studies examining the prognostic value of PET imaging in patients of any age, sex, and CAD status. Systematic screening and data extraction of the identified studies were followed by quantitative meta-analysis of PET-MFR's role in predicting adverse clinical events using random effect model. Studies were appraised using the modified Newcastle-Ottawa tool. RESULTS: A total of 21 studies assessing the prognostic role of PET derived MFR in 46,815 patients with known and/or suspected CAD were included (mean (SD) age 66 (4) years, 48% women). The mean follow-up duration was 36 months (range 10-96). Cardiovascular risk factors were prevalent (73% hypertension, 35% diabetes and 67% dyslipidemia). The definition of the composite outcome varied between studies, with various combinations of mortality, non-fatal myocardial infarction, hospitalization, and coronary revascularization. Pooled impaired MFR was significantly associated with an increased risk of adverse outcomes (RR = 2.94, 95% CI 2.42-3.56, p < 0.001). Results were similar in a subgroup of patients with suspected CAD. CONCLUSIONS: The available body of evidence shows that impaired PET-derived MFR measured using different tracers and PET systems is strongly associated with an increased risk of adverse cardiovascular events. Limitations of this review include observational nature of studies, marked heterogeneity in patient populations, inconsistency in thresholds to define abnormal MFR, and differing components for the composite outcome.

9.
JAMA Oncol ; 9(10): 1401-1416, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37676656

RESUMO

Importance: Lip, oral, and pharyngeal cancers are important contributors to cancer burden worldwide, and a comprehensive evaluation of their burden globally, regionally, and nationally is crucial for effective policy planning. Objective: To analyze the total and risk-attributable burden of lip and oral cavity cancer (LOC) and other pharyngeal cancer (OPC) for 204 countries and territories and by Socio-demographic Index (SDI) using 2019 Global Burden of Diseases, Injuries, and Risk Factors (GBD) Study estimates. Evidence Review: The incidence, mortality, and disability-adjusted life years (DALYs) due to LOC and OPC from 1990 to 2019 were estimated using GBD 2019 methods. The GBD 2019 comparative risk assessment framework was used to estimate the proportion of deaths and DALYs for LOC and OPC attributable to smoking, tobacco, and alcohol consumption in 2019. Findings: In 2019, 370 000 (95% uncertainty interval [UI], 338 000-401 000) cases and 199 000 (95% UI, 181 000-217 000) deaths for LOC and 167 000 (95% UI, 153 000-180 000) cases and 114 000 (95% UI, 103 000-126 000) deaths for OPC were estimated to occur globally, contributing 5.5 million (95% UI, 5.0-6.0 million) and 3.2 million (95% UI, 2.9-3.6 million) DALYs, respectively. From 1990 to 2019, low-middle and low SDI regions consistently showed the highest age-standardized mortality rates due to LOC and OPC, while the high SDI strata exhibited age-standardized incidence rates decreasing for LOC and increasing for OPC. Globally in 2019, smoking had the greatest contribution to risk-attributable OPC deaths for both sexes (55.8% [95% UI, 49.2%-62.0%] of all OPC deaths in male individuals and 17.4% [95% UI, 13.8%-21.2%] of all OPC deaths in female individuals). Smoking and alcohol both contributed to substantial LOC deaths globally among male individuals (42.3% [95% UI, 35.2%-48.6%] and 40.2% [95% UI, 33.3%-46.8%] of all risk-attributable cancer deaths, respectively), while chewing tobacco contributed to the greatest attributable LOC deaths among female individuals (27.6% [95% UI, 21.5%-33.8%]), driven by high risk-attributable burden in South and Southeast Asia. Conclusions and Relevance: In this systematic analysis, disparities in LOC and OPC burden existed across the SDI spectrum, and a considerable percentage of burden was attributable to tobacco and alcohol use. These estimates can contribute to an understanding of the distribution and disparities in LOC and OPC burden globally and support cancer control planning efforts.


Assuntos
Carga Global da Doença , Neoplasias Faríngeas , Adulto , Feminino , Humanos , Masculino , Saúde Global , Incidência , Lábio , Neoplasias Faríngeas/epidemiologia , Anos de Vida Ajustados por Qualidade de Vida , Fatores de Risco , Uso de Tabaco/epidemiologia
10.
11.
Eur Heart J Cardiovasc Imaging ; 24(11): 1470-1477, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37485990

RESUMO

AIMS: It is not well understood whether positron emission tomography (PET)-derived myocardial flow reserve (MFR) is prognostic among patients with prior coronary artery bypass grafting (CABG). METHODS AND RESULTS: Consecutive patients with a clinical indication for PET were enrolled in the Houston Methodist DeBakey Heart and Vascular Center PET registry and followed prospectively for incident outcomes. The primary outcome was a composite of all-cause death, myocardial infarction (MI)/unplanned revascularization, and heart failure admissions. Cox proportional hazards models were used to study the association between MFR (<2 vs. ≥2) and incident events adjusting for clinical and myocardial perfusion imaging variables. The study population consisted of 836 patients with prior CABG; mean (SD) age 68 (10) years, 53% females, 79% Caucasian, 36% non-Hispanic, and 66% with MFR <2. Over a median (interquartile range [IQR]) follow-up time of 12 (4-24) months, there were 122 incident events (46 HF admissions, 28 all-cause deaths, 23 MI, 22 PCI/3 repeat CABG 90 days after imaging). In adjusted analyses, patients with impaired MFR had a higher risk of the primary outcome [hazard ratio (HR) 2.06; 95% CI 1.23-3.44]. Results were significant for admission for heart failure admissions (HR 2.92; 95% CI 1.11-7.67) but not for all-cause death (HR 2.01, 95% CI 0.85-4.79), or MI/UR (HR 1.93, 95% CI 0.92-4.05). CONCLUSION: Among patients with a history of CABG, PET-derived global MFR <2 may identify those with a high risk of subsequent cardiovascular events, especially heart failure, independent of cardiovascular risk factors and perfusion data.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Infarto do Miocárdio , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Feminino , Humanos , Idoso , Masculino , Prognóstico , Intervenção Coronária Percutânea/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Infarto do Miocárdio/etiologia , Insuficiência Cardíaca/etiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Imagem de Perfusão do Miocárdio/métodos
12.
Curr Atheroscler Rep ; 25(7): 351-357, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37162723

RESUMO

PURPOSE OF REVIEW: Despite single-photon emission computerized tomography (SPECT) being the most used nuclear imaging technique for diagnosis of coronary artery disease (CAD), many now consider positron emission tomography (PET) as a superior modality. This review will focus on the advances of cardiac PET in recent years and its advantages compared to SPECT in diagnosis and prognosis of CAD. RECENT FINDINGS: PET's higher resolution and enhanced diagnostic accuracy, as well as lower radiation exposure, all help explain the rationale for its wider spread and use. PET also allows for measurement of myocardial blood flow (MBF) and myocardial flow reserve (MFR), which aids in several different clinical scenarios, such as diagnosing multivessel disease or identifying non-responders. PET has also been shown to be useful in diagnosing CAD in various specific populations, such as patients with prior COVID-19 infection, cardiac transplant, and other comorbidities.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Isquemia Miocárdica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos , Prognóstico , Imagem de Perfusão do Miocárdio/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Teste para COVID-19
13.
Eur Heart J Cardiovasc Imaging ; 24(11): 1544-1554, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37254693

RESUMO

AIMS: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is associated with endothelial dysfunction. We aimed to determine the effects of prior coronavirus disease 2019 (COVID-19) on the coronary microvasculature accounting for time from COVID-19, disease severity, SARS-CoV-2 variants, and in subgroups of patients with diabetes and those with no known coronary artery disease. METHODS AND RESULTS: Cases consisted of patients with previous COVID-19 who had clinically indicated positron emission tomography (PET) imaging and were matched 1:3 on clinical and cardiovascular risk factors to controls having no prior infection. Myocardial flow reserve (MFR) was calculated as the ratio of stress to rest myocardial blood flow (MBF) in mL/min/g of the left ventricle. Comparisons between cases and controls were made for the odds and prevalence of impaired MFR (MFR < 2). We included 271 cases matched to 815 controls (mean ± SD age 65 ± 12 years, 52% men). The median (inter-quartile range) number of days between COVID-19 infection and PET imaging was 174 (58-338) days. Patients with prior COVID-19 had a statistically significant higher odds of MFR <2 (adjusted odds ratio 3.1, 95% confidence interval 2.8-4.25 P < 0.001). Results were similar in clinically meaningful subgroups. The proportion of cases with MFR <2 peaked 6-9 months from imaging with a statistically non-significant downtrend afterwards and was comparable across SARS-CoV-2 variants but increased with increasing severity of infection. CONCLUSION: The prevalence of impaired MFR is similar by duration of time from infection up to 1 year and SARS-CoV-2 variants, but significantly differs by severity of infection.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , SARS-CoV-2 , Coração , Tomografia por Emissão de Pósitrons , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Circulação Coronária , Imagem de Perfusão do Miocárdio/métodos
16.
Curr Cardiol Rep ; 25(4): 261-268, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36826688

RESUMO

PURPOSE OF REVIEW: In this review, we explore the development of digital PET scanners and describe the mechanism by which they work. We dive into some technical details on what differentiates a digital PET from a conventional PET scanner and how such differences lead to better imaging characteristics. Additionally, we summarize the available evidence on the improvements in the images acquired by digital PET as well as the remaining pitfalls. Finally, we report the comparative studies available on how digital PET compares to conventional PET, particularly in the quantification of coronary blood flow. RECENT FINDINGS: The advent of digital PET offers high sensitivity and time-of-flight (TOF), which allow lower activity and scan times, with much less risk of detector saturation. This allows faster patient throughput, scanning more patients per generator, and acquiring more consistent image quality across patients. The higher sensitivity captures more of the potential artifacts, particularly motion-related ones, which presents a current challenge that still needs to be tackled. The digital silicon photomultiplier (SiPM) positron emission tomography (PET) machine has been an important development in the technological advancements of non-invasive nuclear cardiovascular imaging. It has enhanced the utility for PET myocardial perfusion imaging (MPI) and myocardial blood flow (MBF) quantification.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Tomografia por Emissão de Pósitrons/métodos , Coração , Circulação Coronária , Perfusão , Tecnologia , Imagem de Perfusão do Miocárdio/métodos , Doença da Artéria Coronariana/diagnóstico por imagem
17.
J Nucl Cardiol ; 30(4): 1484-1496, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36607537

RESUMO

BACKGROUND: Splenic switch-off (SSO) is a phenomenon describing a decrease in splenic radiotracer uptake after vasodilatory stress. We aimed to assess the diagnostic utility of regadenoson-induced SSO. METHODS: We included consecutive patients who had clinically indicated Regadenoson Rb-82 PET-MPI for suspected CAD. This derivation cohort (no perfusion defects and myocardial flow reserves (MFR) ≥ 2) was used to calculate the splenic response ratio (SRR). The validation cohort was defined as patients who underwent both PET-MPI studies and invasive coronary angiography (ICA). RESULTS: The derivation cohort (n = 100, 57.4 ± 11.6 years, 77% female) showed a decrease in splenic uptake from rest to stress (79.9 ± 16.8 kBq⋅mL vs 69.1 ± 16.2 kBq⋅mL, P < .001). From the validation cohort (n = 315, 66.3 ± 10.4 years, 67% male), 28% (via SRR = 0.88) and 15% (visually) were classified as splenic non-responders. MFR was lower in non-responders (SRR; 1.55 ± 0.65 vs 1.76 ± 0.78, P = .02 and visually; 1.18 ± 0.33 vs 1.79 ± 0.77, P < .001). Based on ICA, non-responders were more likely to note obstructive epicardial disease with normal PET scans especially in patients with MFR < 1.5 (SRR; 61% vs 34% P = .05 and visually; 68% vs 33%, P = .01). CONCLUSION: Lack of splenic response based on visual or quantitative assessment of SSO may be used to identify an inadequate vasodilatory response.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Feminino , Radioisótopos de Rubídio , Purinas/farmacologia , Tomografia por Emissão de Pósitrons , Doença da Artéria Coronariana/diagnóstico por imagem
19.
J Am Coll Cardiol ; 81(4): 374-389, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36697138

RESUMO

BACKGROUND: The optimal strategy for thromboprophylaxis in patients with a Fontan circulation is unknown. OBJECTIVES: The aim of this study was to compare the efficacy and safety of aspirin, warfarin, and nonvitamin K oral anticoagulants (NOACs) in a network meta-analysis. METHODS: Relevant studies published by February 2022 were included. The primary efficacy outcome was thromboembolic events; major bleeding was a secondary safety outcome. Frequentist network meta-analyses were conducted to estimate the incidence rate ratios (IRRs) of both outcomes. Ranking of treatments was performed based on probability (P) score. RESULTS: A total of 21 studies were included (26,546 patient-years). When compared with no thromboprophylaxis, NOAC (IRR: 0.11; 95% CI: 0.03-0.40), warfarin (IRR: 0.23; 95% CI: 0.14-0.37), and aspirin (IRR: 0.24; 95% CI: 0.15-0.39) were all associated with significantly lower rates of thromboembolic events. However, the network meta-analysis revealed no significant differences in the rates of major bleeding (NOAC: IRR: 1.45 [95% CI: 0.28-7.43]; warfarin: IRR: 1.38 [95% CI: 0.41-4.69]; and aspirin: IRR: 0.72 [95% CI: 0.20-2.58]). Rankings, which simultaneously analyze competing interventions, suggested that NOACs have the highest P score to prevent thromboembolic events (P score 0.921), followed by warfarin (P score 0.582), aspirin (P score 0.498), and no thromboprophylaxis (P score 0.001). Aspirin tended to have the most favorable overall profile. CONCLUSIONS: Aspirin, warfarin, and NOAC are associated with lower risk of thromboembolic events. Recognizing the limited number of patients and heterogeneity of studies using NOACs, the results support the safety and efficacy of NOACs in patients with a Fontan circulation.


Assuntos
Fibrilação Atrial , Técnica de Fontan , Acidente Vascular Cerebral , Tromboembolia , Humanos , Varfarina/efeitos adversos , Anticoagulantes/efeitos adversos , Técnica de Fontan/efeitos adversos , Técnica de Fontan/métodos , Administração Oral , Hemorragia/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Aspirina/efeitos adversos , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
20.
Eur J Nucl Med Mol Imaging ; 50(4): 1103-1110, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36474124

RESUMO

PURPOSE: We evaluated whether serum beta-hydroxybutyrate (BHB) can identify adequate suppression of the left ventricle (LV) among patients undergoing [18F]-fluorodeoxyglucose positron emission tomography ([18F]-FDG PET) for cardiac inflammatory/infectious studies. METHODS: Consecutive patients who underwent [18F]-FDG PET imaging were included. Serum BHB levels were measured in all patients on the day of imaging prior to injecting [18F]-FDG. Myocardial [18F]-FDG suppression was defined if [18F]-FDG uptake in the walls of myocardium, measured using standardized uptake values (SUV), was lower than the blood pool. The optimal threshold of BHB to identify myocardial suppression was based on receiver operating characteristics (ROC) in a random 30% sample of the study population (derivation cohort) and tested in the remaining 70% of sample (validation cohort). RESULTS: A total of 256 images from 220 patients were included. Patients with sufficient LV suppression had significantly higher BHB levels compared to those with non-suppressed myocardium (median (IQR) BHB 0.6 (0.3-0.8) vs. 0.2 (0.2-0.3) mmol/l, p < 0.001, respectively). BHB level ≥ 0.335 mmol/l had a sensitivity of 84.90% and a specificity of 92.60% to identify adequate LV suppression in the validation cohort. All patients (100%) with BHB ≥ 0.41 mmol/l had adequate myocardial suppression compared to 29.63% of patients with BHB ≤ 0.20 mmol/l. CONCLUSION: Serum BHB level can be used at the point of care to identify sufficient LV suppression in patients undergoing [18F]-FDG PET cardiac inflammatory/infectious studies. Central illustration (image to the right) shows representative cases of patient images and BHB and, in the image to the left, shows the sensitivity and specificity to identify left myocardial suppression using BHB in validation group.


Assuntos
Fluordesoxiglucose F18 , Cardiopatias , Humanos , Ácido 3-Hidroxibutírico , Compostos Radiofarmacêuticos , Miocárdio , Tomografia por Emissão de Pósitrons/métodos , Glucose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA