Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Talanta ; 274: 126016, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38599118

RESUMO

The present study investigates the use of dextrins (maltodextrin, ß-cyclodextrin, and hydroxypropyl-ß-cyclodextrin) to improve the efficiency of the agarose-based gel electromembrane extraction technique for extracting chiral basic drugs (citalopram, hydroxyzine, and cetirizine). Additionally, it examines the enantioselectivity of the extraction process for these drugs. To achieve these, dextrins were incorporated into either the sample solution, the membrane, or the acceptor solution, and then the extraction procedure was performed. Enantiomers were separated and analyzed using a capillary electrophoresis device equipped with a UV detector. The results obtained under the optimal extraction conditions (sample solution pH: 4.0, acceptor solution pH: 2.0, gel membrane pH: 3.0, agarose concentration: 3 % w/v, stirring rate: 1000 rpm, gel thickness: 4.4 mm, extraction voltage: 62.3 V, and extraction time: 32.1 min) indicated that incorporating dextrins into either the sample solution, membrane or the acceptor solution enhances extraction efficiency by 17.3-23.1 %. The most significant increase was observed when hydroxypropyl-ß-cyclodextrin was added to the acceptor solution. The findings indicated that the inclusion of hydroxypropyl-ß-cyclodextrin in the sample solution resulted in an enantioselective extraction, yielding an enantiomeric excess of 6.42-7.14 %. The proposed method showed a linear range of 5.0-2000 ng/mL for enantiomers of model drugs. The limit of detection and limit of quantification for all enantiomers were found to be < 4.5 ng/mL and <15.0 ng/mL, respectively. Intra- and inter-day RSDs (n = 4) were less than 10.8 %, and the relative errors were less than 3.2 % for all the enantiomers. Finally, the developed method was successfully applied to determine concentrations of enantiomers in a urine sample with relative recoveries of 96.8-99.2 %, indicating good reliability of the developed method.


Assuntos
Dextrinas , Géis , Membranas Artificiais , Estereoisomerismo , Dextrinas/química , Géis/química , Eletroforese Capilar/métodos , Hidroxizina/análise , Hidroxizina/isolamento & purificação , Hidroxizina/química , Hidroxizina/urina , beta-Ciclodextrinas/química , 2-Hidroxipropil-beta-Ciclodextrina/química , Cetirizina/química , Cetirizina/urina , Cetirizina/análise , Cetirizina/isolamento & purificação , Concentração de Íons de Hidrogênio , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Preparações Farmacêuticas/isolamento & purificação , Preparações Farmacêuticas/urina , Sefarose/química
2.
J Chromatogr A ; 1708: 464335, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37696127

RESUMO

In this work, carboxymethylated maltodextrin (Cm-MD) was successfully synthesized as an efficient anionic chiral selector and applied for the enantiomer separation of some basic drugs including tramadol, venlafaxine, verapamil, hydroxyzine, citalopram, fluoxetine, and amlodipine by capillary electrophoresis (CE). The synthesized chiral selector was characterized by the nuclear magnetic resonance and Fourier transform infrared spectrophotometry. Under the optimized Cm-MD modified CE conditions (background electrolyte: phosphate buffer (pH 5.0, 50 mM) containing 5% (w/v) Cm-MD; applied voltage: 20 kV; and capillary column temperature: 25 °C), successful enantiomer separation of all studied chiral drugs were observed. By comparison of Cm-MD and MD for enantiomer separation of the model drugs, it was revealed that Cm-MD exhibits a higher resolution in comparison to the MD modified CE. This enhanced resolution could be attributed to the electrostatic interactions between the cationic drugs and anionic Cm-MD and opposite direction mobility of the host-guest complex relative to the chiral analyte. The optimized Cm-MD modified CE method was successfully used for the assay of the enantiomers of citalopram and venlafaxine in commercial tablets. The proposed method showed the linear range of 5.0-150.0 mg/L and 10.0-150.0 mg/L for both enantiomers of citalopram and venlafaxine, respectively. The limits of quantification were 5.0 and 10.0 mg/L for the enantiomers of citalopram and venlafaxine, respectively. The limit of detection for all enantiomers was found to be < 3.0 mg/L. Intra- and inter-day RSDs (n = 4) were less than 9.7%. The relative errors were less than 9.4% for all enantiomers. The obtained results in this research show that Cm-MD as a new, efficient and inexpensive chiral selector can be used for enantiomer separation of basic drugs using the CE technique.


Assuntos
Citalopram , Eletroforese Capilar , Cloridrato de Venlafaxina , Anlodipino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA