Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Invasive Cardiol ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38598251

RESUMO

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.

2.
Clin Res Cardiol ; 113(1): 68-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37294310

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic stenosis in patients with intermediate to prohibitive surgical risk. When a single TAVI device fails and cannot be retrieved, TAVI-in-TAVI must be performed acutely, but outcomes of bailout TAVI-in-TAVI have been incompletely appraised. We aimed at analyzing patient, procedural and outcome features of patients undergoing bailout TAVI-in-TAVI in a multicenter registry. METHODS: Details of patients undergoing bailout TAVI-in-TAVI, performed acutely or within 24 h of index TAVI, in 6 international high-volume institutions, were collected. For every case provided, 2 same-week consecutive controls (prior TAVI, and subsequent TAVI) were provided. Outcomes of interest were procedural and long-term events, including death, myocardial infarction, stroke, access site complication, major bleeding, and reintervention, and their composite (i.e. major adverse events [MAE]). RESULTS: A total of 106 patients undergoing bailout TAVI-in-TAVI were included, as well as 212 controls, for a total of 318 individuals. Bailout TAVI-in-TAVI was less common in younger patients, those with higher body mass index, or treated with Portico/Navitor or Sapien devices (all p < 0.05). Bailout TAVI-in-TAVI was associated with higher in-hospital rates of death, emergency surgery, MAE, and permanent pacemaker implantation (all p < 0.05). Long-term follow-up showed that bailout TAVI-in-TAVI was associated with higher rates of death and MAE (both < 0.05). Similar findings were obtained at adjusted analyses (all p < 0.05). However, censoring early events, outlook was not significantly different when comparing the two groups (p = 0.897 for death, and p = 0.645 for MAE). CONCLUSIONS: Bail-out TAVI-in-TAVI is associated with significant early and long-term mortality and morbidity. Thus, meticulous preprocedural planning and sophisticated intraprocedural techniques are of paramount importance to avoid these emergency procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Valva Aórtica/cirurgia , Fatores de Risco
3.
Clin Res Cardiol ; 113(1): 86-93, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37391628

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve. METHODS: We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed. RESULTS: A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05). CONCLUSIONS: Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia
4.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
5.
Am J Cardiol ; 201: 349-358, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37423004

RESUMO

Transcatheter aortic valve replacement (TAVR) is an established therapy for severe, symptomatic aortic valve stenosis even in patients with impaired left ventricular systolic function. However, there is uncertainty on the clinical effectiveness of the currently available TAVR devices in patients with reduced left ventricular ejection fraction (LVEF). The LOSTAVI (Low Systolic function and Transcatheter Aortic Valve Implantation) registry is a retrospective observational study using baseline, procedural, discharge, and long-term follow-up details. A total of 3 groups of interest were distinguished: extremely reduced LVEF (<25%), severely reduced LVEF (25% to 30%), and reduced LVEF (31% to 35%). Unadjusted and adjusted analyses were carried out for in-hospital and follow-up outcomes. A total of 923 patients were included from 12 centers, with 146 patients (16%) with LVEF <25%, 425 (46%) with LVEF 25% to 30%, and 352 (38%) with LVEF 31% to 35%. Several baseline and procedural features were different across groups, including age, risk, functional class, and prevalence of bicuspid disease (all p <0.05). In-hospital mortality was similar in the 3 groups (7 [4.8%], 18 [4.2%], and 7 [2.0%], respectively, p = 0.661), but major adverse events were more common in those with extremely reduced and severely reduced LVEF (19 [13%], 53 [13%], and 25 [7.1%], respectively, p = 0.024). The 12-month follow-up confirmed the significant detrimental impact of reduced LVEF on both death (21 [14%], 49 [12%], and 25 [7.1%], respectively, p = 0.024) and major adverse events (37 [25%], 89 [21%], and 53 [15%], respectively, p = 0.016). The adjusted analysis confirmed the significant prognostic role of LVEF on both outcomes, whereas TAVR device type was not associated with death or major adverse events (all p >0.05). In conclusion, TAVR yields favorable early and 1-year results in patients with reduced LVEF, including those with extremely depressed systolic dysfunction. However, reduced LVEF still represents a major adverse prognostic factor for both short- and mid-term outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Resultado do Tratamento , Sistema de Registros , Estudos Retrospectivos , Valva Aórtica/cirurgia
6.
Minerva Cardiol Angiol ; 71(3): 324-332, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35332751

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is emerging as an appealing management strategy for patients with severe aortic stenosis at intermediate, high or exceedingly high risk, but its risk-benefit profile in younger patients is less certain. We aimed to explore the outlook of patients aged 70 years or less and undergoing TAVI at 2 high-volume Italian institutions. METHODS: We retrospectively collected baseline, imaging, procedural and outcome features of patients with age ≤70 years in whom TAVI was attempted at participating centers between 2012 and 2021. Non-parametric tests and bootstrap resampling were used for inferential purposes. RESULTS: A total of 39 patients were included, out of >3000 screened with heart team involvement and >1500 receiving TAVI. Most common or relevant indications for TAVI reduced life expectancy (e.g. cardiogenic shock or severe left ventricular systolic dysfunction), chronic obstructive pulmonary disease, morbid obesity, active or recent extra-cardiac cancer, porcelain aorta, neurologic disability, cirrhosis, or prior surgical aortic valve replacement, as well as extreme cachexia, and Hutchinson-Gilford progeria. At least two contemporary high-risk features were present in most cases. Transapical access was used in 5 (12.8%) cases, and a sheathless approach in 15 (38.5%). A variety of devices were used, including both balloon- and self-expandable devices. Clinical outcomes were satisfactory, despite the high-risk profile, at both short- and mid-term, with no in-hospital death, and 5.1% (95% confidence interval 0-12.8%) mortality at a median follow-up of 15 months (minimum 1; maximum 85). Notably, no case of significant valve deterioration requiring reintervention occurred. CONCLUSIONS: In carefully selected patients with 70 years or less of age and prohibitive risk for surgery or reduced life expectancy, TAVI represents a safe option with a favorable mid-term survival and low rate of adverse events.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia
7.
Minerva Cardiol Angiol ; 70(6): 677-685, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36222602

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has revolutionized the management of aortic stenosis. We aimed at appraising effectiveness of a new self-expandable TAVI device. METHODS: We retrospectively analyzed our institutional experience with Allegra (Biosensors, Morges, Switzerland) for TAVI, focusing on procedural outcomes and 1-month adverse events. We explored the impact of operator experience with this device, dividing patients according to their time of intervention. RESULTS: Between 2018 and 2021, a total of 50 patients underwent TAVI with Allegra, with average age of 81 years, 80% women, and 50% at low or intermediate surgical risk. No major significant difference in baseline patient features were found when comparing Phase 1 and Phase 2, except for baseline left ventricular ejection fraction and New York Heart Association, which were worse in Phase 1. All procedures were performed transfemorally and percutaneously, with predilation in 94% and postdilation in 36%, yielding device success in 98%, and procedural success in 96%. No significant differences in procedural features were found when comparing Phase 1 vs. Phase 2 (all P>0.05). One-month follow-up was also favorable, with no significant difference in adverse outcomes according to phase, and a total of 1 (4%) death, 1 (4%) myocardial infarction, 1 (4%) minor vascular complication, and 4 (8%) permanent pacemaker implantations. Consistent findings were obtained at exploratory 6-month follow-up. CONCLUSIONS: The Allegra TAVI device is associated with favorable short-to-midterm outcomes in experienced hands. Operators already proficient with other devices can achieve satisfactory results even in the early phase of adoption of Allegra.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda
8.
Catheter Cardiovasc Interv ; 100(1): 114-119, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35557027

RESUMO

Transcatheter aortic valve implantation (TAVI) has proved beneficial in patients with severe aortic stenosis, especially when second-generation devices are used. We aimed at reporting our experience with Navitor, a third-generation device characterized by intrannular, large cell, and cuffed design, as well as high deliverability and minimization of paravalvular leak. Between June and December 2021, a total of 39 patients underwent TAVI with Navitor, representing 20% of all TAVI cases. Mean age was 80.0 ± 6.7 years, and 14 (36.8%) women were included. Severe aortic stenosis was the most common indication to TAVI (37 [97.4%] cases), whereas 2 (5.3%) individuals were at low surgical risk. Device and procedural success was obtained in all patients, with a total hospital stay of 6.6 ± 4.5 days. One (2.9%) patient required permanent pacemaker implantation, but no other hospital events occurred. At 1-month follow-up, a cardiac death was adjudicated in an 87-year-old man who had been at high surgical risk. Echocardiographic follow-up showed no case of moderate or severe aortic regurgitation, with mild regurgitation in 18 (47%), and none or trace regurgitation in 20 (53%). The Navitor device, thanks to its unique features, is a very promising technology suitable to further expand indications and risk-benefit profile of TAVI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
J Invasive Cardiol ; 34(6): E419-E427, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35551105

RESUMO

BACKGROUND: The differential outcomes between pure/predominant aortic stenosis (AS) and mixed aortic valve disease (MAVD) in patients undergoing transcatheter aortic valve implantation (TAVI) are still debated. OBJECTIVE: To evaluate the comparative clinical outcomes of patients with MAVD and AS undergoing TAVI using data from the RISPEVA registry. METHODS: A total of 3263 patients were included. Of the 3263 patients, 656 with concomitant moderate/severe aortic regurgitation constituted the MAVD group and 2607 constituted the AS cohort. Primary endpoints were 30-day mortality and 1-year survival. Postprocedural paravalvular regurgitation (PPVR), cerebrovascular events, bleeding, and vascular complications were assessed at 30 days. RESULTS: In the overall population, 30-day mortality in the MAVD group was higher than in AS patients (4.3% vs 2.6%;P=.02); however, no differences were detected after propensity-score matching (4.1% vs 3.5%; P=.62). One-year survival was comparable between MAVD and AS patients in both unmatched and matched cohorts. Left ventricular ejection fraction, pulmonary artery systolic pressure, and PPVR, but not baseline MAVD, were predictors of 30-day mortality. The incidence of PPVR was higher in the MAVD group vs the AS group; this difference was not confirmed in patients implanted with a balloon-expandable device. CONCLUSION: MAVD per se did not negatively affect patients' prognoses, but appears to identify a more complex cohort of patients with a worse clinical and functional status, probably referred to TAVI in a later stage of the disease. Patients with MAVD had a greater propensity to develop PPVR, which is a known predictor of worse outcome; this tendency seems to be mitigated by the implantation of balloon-expandable valves.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Pontuação de Propensão , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
10.
Panminerva Med ; 64(4): 427-437, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35638242

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI. METHODS: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038). CONCLUSIONS: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Sistema de Registros , Estudos Retrospectivos , Valva Aórtica/cirurgia , Fatores de Risco
11.
Sci Rep ; 12(1): 7612, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35534616

RESUMO

Transcatheter aortic valve implantation (TAVI) requires thorough preprocedural planning with non-invasive imaging, including computed tomography (CT). The plethora of details obtained with thoraco-abdominal CT represents a challenge for accurate and synthetic decision-making. We devised and tested a comprehensive score suitable to summarize CT exams when planning TAVI. An original comprehensive scoring system (TAVI-CT score) was devised, including details on cardiac, aortic, iliac and femoral artery features. The score was applied to a prospectively collected series of patients undergoing TAVI at our institution, driving decision making on access and prosthesis choice. Different TAVI-CT score groups were compared in terms of procedural success, acute complications, and early clinical outcomes. We included a total of 200 undergoing TAVI between February 2020 and May 2021, with 74 (37.0%) having a low (0-2) TAVI-CT score, 50 (25.0%) having a moderate (3) TAVI-CT score, and 76 (38.0%) having a high (≥ 4) TAVI-CT score. Male gender was the only non-CT variable significantly associated with the TAVI-CT score (p = 0.001). As expected, access choice differed significantly across TAVI-CT scores (p = 0.009), as was device choice, with Portico more favored and Allegra less favored in the highest TAVI-CT score group (p = 0.036). Acute outcomes were similar in the 3 groups, including device and procedural success rates (respectively p = 0.717 and p = 1). One-month follow-up showed similar rates of death, myocardial infarction, stroke, and bleeding, as well as of a composite safety endpoint (all p > 0.05). However, vascular complications were significantly more common in the highest TAVI-CT score group (p = 0.041). The TAVI-CT score is a simple scoring system that could be routinely applied to CT imaging for TAVI planning, if the present hypothesis-generating findings are confirmed in larger prospective studies.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
12.
J Invasive Cardiol ; 34(4): E319-E325, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35366226

RESUMO

BACKGROUND: The next iteration of drug-eluting stents (DESs) for percutaneous coronary intervention (PCI) has focused on bioresorbable polymers and thin struts. The Alex Plus DES is a new-generation sirolimus-eluting device with 70-µm cobalt chromium struts, a 5-µm bioresorbable polymer and a very small profile. Despite such favorable features, limited data are available to estimate the risk-benefit profile of Alex Plus. We aimed at comparing the effectiveness of Alex Plus in real-world practice. METHODS: Retrospective clinical data on patients treated with Alex Plus at our institutions were collected and clinical outcome data over follow-up were obtained, comparing them with those of subjects receiving Xience, a leading DES with permanent polymer. RESULTS: A total of 100 patients (126 lesions) treated with Alex Plus and 753 subjects (1020 lesions) receiving Xience were included. Baseline and procedural features were largely similar in the 2 groups, with the notable exception of age, sex, and left circumflex coronary artery as the target vessel. Clinical follow-up showed that patients with Alex Plus had a significantly higher risk of major adverse clinical event (MACE), mainly driven by an excess in repeat PCI (hazard ratio, 4.81; 95% confidence interval, 2.83-8.20; P<.001). Even after propensity-score matching, Alex Plus was associated with an increased risk of MACE (P<.001). CONCLUSIONS: Our clinical experience to date with Alex Plus has been disappointing, despite the favorable promises. Further improvements are likely needed in the Alex Plus DES, most likely in drug delivery, before this device is considered for routine clinical use in complex patients or lesions.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Pontuação de Propensão , Estudos Retrospectivos
13.
J Clin Med ; 11(2)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35054151

RESUMO

The vascular system is largely exposed to the effect of changing flow conditions. Vascular cells can sense flow and its changes. Flow sensing is of pivotal importance for vascular remodeling. In fact, it influences the development and progression of atherosclerosis, controls its location and has a major influx on the development of local complications. Despite its importance, the research community has traditionally paid scarce attention to studying the association between different flow conditions and vascular biology. More recently, a growing body of evidence has been accumulating, revealing that ncRNAs play a key role in the modulation of several biological processes linking flow-sensing to vascular pathophysiology. This review summarizes the most relevant evidence on ncRNAs that are directly or indirectly responsive to flow conditions to the benefit of the clinician, with a focus on the underpinning mechanisms and their potential application as disease biomarkers.

14.
J Invasive Cardiol ; 33(6): E474-E478, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34001674

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a safe and beneficial treatment for patients with severe symptomatic aortic stenosis at high and intermediate surgical risk. Success rates for TAVI continue to increase due to more refined procedural approaches and devices, and above all, to the improvements in procedural knowledge by TAVI operators. The development of a new delivery system represents an important evolutionary process in the TAVI procedure, both for the type of device and for the operators, as it may substantially expand indications, success rates, and safety. FlexNav (Abbott Cardiovascular) is a novel delivery system designed to improve ease and precision of TAVI using the Abbott Portico valve. Despite limited results on its advantages, such as those provided in the PORTICO investigational device exemption substudy, uncertainty persists on the actual role of FlexNav in real-world practice. METHODS AND RESULTS: We hereby present our preliminary experience with FlexNav in a consecutive series of 18 patients undergoing TAVI with Portico valve in early 2020 (3 with axillary access). Procedural results were excellent, as shown by the absence of deaths, strokes, and major vascular complications (95% confidence interval, 0%-18.5%), and pacemaker implantation in 3 subjects (21.4%; 95% confidence interval, 4.7%-50.8%). CONCLUSIONS: Despite the small sample size, the present case series suggests that adoption of the FlexNav novel delivery system for TAVI with Portico valve is feasible and safe, and holds the promise of further improving early and long-term results of this procedure.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
J Cardiovasc Transl Res ; 14(6): 1104-1113, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33721196

RESUMO

Thrombocytopenia after TAVI is common and clinically detrimental. Retrospectively, we observed Portico recipients had a more profound platelet drop than Evolut recipients. We thus investigated periprocedural platelet damage and/orpro-inflammatory state in 64 TAVI recipients at baseline and after implantation. Platelet damage was assessed by annexin V staining and monocyte-phagocytic phenotype was assessed according to CD14/CD36 expression. Serum cytokines were measured in 20 patients. The formaldehyde-based storage solution altered platelets. When, before being loaded onto the delivery system, Portico underwent one additional flushing to those recommended, the receiving patients showed thrombocytopenia, platelet damage, and CD36-monocyte count were mitigated. A general increase in IL-6 was recorded in overall TAVI recipients, but a high serum level of IL-8, a potent thrombocytopenia inducer, was measured in Portico recipients only, including those with extra-rinsed valve. Our study suggests a platelet-injury effect by storage-solution and generates the hypothesis of a role for the biomaterial in stimulating innate-immunity. Larger prospective studies are needed. Graphical Abstract.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/etiologia , Trombocitopenia/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Citocinas/sangue , Feminino , Humanos , Itália , Masculino , Desenho de Prótese , Estudos Retrospectivos
16.
Minerva Med ; 112(4): 474-482, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33576201

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become first-line treatment for severe aortic valve stenosis in patients with moderate, high or prohibitive surgical risk. However, access site complications may occur more frequently in extreme body mass index (BMI) categories. The aim of this study was to describe the features and outcomes of patients undergoing TAVI in a comprehensive Italian prospective clinical registry, focusing on BMI classes. METHODS: A national prospective database was queried for baseline, procedural, and outcome details of patients undergoing TAVI according to established BMI categories: underweight (BMI <18.5 kg/m2), normal weight (BMI 18.5-24.9 kg/m2), overweight (BMI 25.0-29.9 kg/m2), and obese (BMI≥30 kg/m2). Short- and long-term outcomes, including major adverse events (MAE), i.e. the composite of death, stroke, myocardial infarction, major vascular complication, major bleeding, or renal failure, were appraised with bivariate and multivariable analyses. RESULTS: A total of 3075 subjects were included, 64 (2.1%) were underweight, 1319 (42.9%) were normal weight, 1152 (37.4%) were overweight, and 540 (17.6%) were obese. Several baseline differences were evident, including gender, diabetes mellitus, renal function, chronic obstructive pulmonary disease, surgical scores, and left ventricular ejection fraction (LVEF) (all P<0.05). Several procedural differences were also evident, including percutaneous approach, predilation, prosthesis type and size (all P<0.05), with postprocedural aortic regurgitation >2+ significantly more common in underweight patients (P<0.05). Nonetheless, unadjusted analysis for one-month outcomes showed similar rates for fatal and non-fatal outcomes, including MAE (all P>0.05), with the notable exception of permanent pacemaker implantation, which was more common in higher BMI classes (P=0.010) Unadjusted analysis for long-term events showed an increased rate of death in underweight patients (P=0.024). Multivariable adjusted analysis confirmed the increased risk of permanent pacemaker implantation in obese patients (P=0.015 when comparing obese vs. normal weight subjects), but disproved differences in long-term mortality and other outcomes (P>0.05 for all comparisons). CONCLUSIONS: Irrespective of BMI class, TAVI is associated with favorable outcomes in surgical high-risk risk patients, with the notable exclusion of permanent pacemaker implantation, which is significantly more common in obese subjects.


Assuntos
Estenose da Valva Aórtica/cirurgia , Índice de Massa Corporal , Substituição da Valva Aórtica Transcateter/efeitos adversos , Análise de Variância , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/mortalidade , Feminino , Humanos , Itália , Masculino , Infarto do Miocárdio/epidemiologia , Sobrepeso/complicações , Sobrepeso/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Insuficiência Renal/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Magreza/complicações , Magreza/epidemiologia , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento , Doenças Vasculares/epidemiologia
17.
Int J Mol Sci ; 21(21)2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-33114544

RESUMO

The 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitors (statins) exert pleiotropic effects on cardiac cell biology which are not yet fully understood. Here we tested whether statin treatment affects resident endogenous cardiac stem/progenitor cell (CSC) activation in vitro and in vivo after myocardial infarction (MI). Statins (Rosuvastatin, Simvastatin and Pravastatin) significantly increased CSC expansion in vitro as measured by both BrdU incorporation and cell growth curve. Additionally, statins increased CSC clonal expansion and cardiosphere formation. The effects of statins on CSC growth and differentiation depended on Akt phosphorylation. Twenty-eight days after myocardial infarction by permanent coronary ligation in rats, the number of endogenous CSCs in the infarct border zone was significantly increased by Rosuvastatin-treatment as compared to untreated controls. Additionally, commitment of the activated CSCs into the myogenic lineage (c-kitpos/Gata4pos CSCs) was increased by Rosuvastatin administration. Accordingly, Rosuvastatin fostered new cardiomyocyte formation after MI. Finally, Rosuvastatin treatment reversed the cardiomyogenic defects of CSCs in c-kit haploinsufficient mice, increasing new cardiomyocyte formation by endogenous CSCs in these mice after myocardial infarction. In summary, statins, by sustaining Akt activation, foster CSC growth and differentiation in vitro and in vivo. The activation and differentiation of the endogenous CSC pool and consequent new myocyte formation by statins improve myocardial remodeling after coronary occlusion in rodents. Similar effects might contribute to the beneficial effects of statins on human cardiovascular diseases.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Células Musculares/citologia , Infarto do Miocárdio/tratamento farmacológico , Miocárdio/citologia , Células-Tronco/efeitos dos fármacos , Animais , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Modelos Animais de Doenças , Feminino , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Camundongos , Células Musculares/efeitos dos fármacos , Células Musculares/metabolismo , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/metabolismo , Miocárdio/metabolismo , Fosforilação/efeitos dos fármacos , Pravastatina/administração & dosagem , Pravastatina/farmacologia , Proteínas Proto-Oncogênicas c-akt/metabolismo , Ratos , Rosuvastatina Cálcica/administração & dosagem , Rosuvastatina Cálcica/farmacologia , Sinvastatina/administração & dosagem , Sinvastatina/farmacologia , Células-Tronco/citologia , Células-Tronco/metabolismo
18.
Sci Rep ; 10(1): 17144, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33051585

RESUMO

Percutaneous mitral valve repair has been increasingly performed worldwide after approval. We sought to investigate predictors of clinical outcome in patients with mitral regurgitation undergoing percutaneous valve repair. The MITRA-UMG study, a single-centre registry, retrospectively collected consecutive patients with symptomatic moderate-to-severe or severe MR undergoing MitraClip therapy. The primary endpoint was the composite of cardiovascular death or rehospitalization for heart failure. Between March 2012 and July 2018, a total of 150 consecutive patients admitted to our institution were included. Procedural success was obtained in 95.3% of patients. The composite primary endpoint of cardiovascular death or rehospitalization for HF was met in 55 patients (37.9%) with cumulative incidences of 7.6%, 26.2%, at 30 days and 1-year, respectively. In the Cox multivariate model, NYHA functional class and left ventricular end-diastolic volume index (LVEDVi), independently increased the risk of the primary endpoint at long-term follow-up. At Kaplan-Meier analysis, a LVEDVi > 92 ml/m2 was associated with an increased incidence of the primary endpoint. In this study, patients presenting with dilated ventricles (LVEDVi > 92 ml/m2) and advanced heart failure symptoms (NYHA IV) at baseline carried the worst prognosis after percutaneous mitral valve repair.


Assuntos
Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Idoso , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia/métodos , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Hospitalização , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Resultado do Tratamento
19.
Angiology ; 68(4): 281-287, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27401210

RESUMO

Since the first cardiac catheterization in 1929, this procedure has evolved considerably. Historically performed via the transfemoral access, in the last years, the transradial access has been spreading gradually due to its many advantages. We have conducted a review of published literature concerning efficacy, safety, and cost-effectiveness, and we analyzed our patients' data, including the results of the recently published Minimizing Adverse hemorrhagic events by TRansradial access site and systemic implementation of angioX (MATRIX) study. This review confirmed the superiority of the transradial access compared to the femoral access, especially regarding complications related to the access site, duration of hospitalization, and comfort for the patient. The transradial approach is an excellent option for coronary angiography, and the procedure's risks are reduced by increased operator experience.


Assuntos
Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Artéria Femoral , Artéria Radial , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/efeitos adversos , Análise Custo-Benefício , Feminino , Humanos , Tempo de Internação , Masculino , Segurança do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA