Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
2.
Perfusion ; : 2676591241232803, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38316491

RESUMO

Background: Although the Avalon Elite bi-caval dual lumen catheter for veno-venous extracorporeal membranous oxygenation (ECMO) has many advantages, it requires precise positioning and dislodgement is common.Case presentation: A 2-year-old male was placed on ECMO due to respiratory failure utilizing a 20 Fr Avalon Elite bi-caval dual lumen catheter (AEC). The AEC migrated twice with unsuccessful repositioning using the classic manual manipulations. The AEC was successfully repositioned on the two occasions using a novel method by direct access of the ECMO inflow tube using a combination of catheter and guide wire.Conclusions: A migrated AEC could be successfully repositioned with simple direct access of the inflow tube. This technique was successfully utilized twice at the bedside in an infant without needing additional venous access.

4.
Catheter Cardiovasc Interv ; 103(4): 612-617, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38419395

RESUMO

While newer self-expanding pulmonic valves were primarily designed for larger right ventricular outflow tracks, there are instances where even larger anatomies cannot accommodate these devices. In this report, we describe the successful implantation of two Harmony™ valves in bilateral branch pulmonary arteries after exhausting other options.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco
5.
Cardiol Young ; 34(3): 694-697, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38224239

RESUMO

Pulmonary vein stenosis continues to pose significant challenges in children, frequently requiring repeated cardiac catheterisation procedures. This report describes a successful application of a "triple kissing balloon" technique to treat complex pulmonary vein stenosis in two patients, all accomplished with the use of a single 6-French sheath.


Assuntos
Estenose de Veia Pulmonar , Criança , Humanos , Estenose de Veia Pulmonar/cirurgia , Cateterismo Cardíaco
6.
Pediatr Cardiol ; 44(8): 1808-1814, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37129601

RESUMO

Safety and acute outcomes for patients who need catheterization shortly after congenital cardiac surgery has been established; literature on mid-term outcomes is lacking. We sought to evaluate the mid-term outcomes of patients who undergo early postoperative cardiac catheterization. This is a retrospective cohort study of patients who underwent cardiac catheterization within 6 weeks of congenital cardiac surgery with longitudinal follow-up and assessment of mid-term outcomes. Multivariable analysis was utilized to relate variables of interest to outcomes. 99 patients underwent cardiac catheterizations within 6 weeks of cardiac surgery between January 2008 and September 2016. Forty-six (45.5%) interventional procedures were performed at a median age of 41 days (IQR 21-192) and a median weight of 3.9 kg (3.3-6.6). During a median follow-up duration of 4.24 years (1.6-5.6) in study survivors, 61% of patients remained free from the primary endpoint (death and/or transplant). Sixty-nine patients (69.7%) underwent an unplanned surgical or catheter procedure. Renal failure at catheterization (OR 280.5, p 0.0199), inotropic medication at catheterization (OR 14.8, p 0.002), and younger age were all significantly associated with meeting the primary endpoint. Patients requiring surgical intervention as an initial additional intervention underwent more unplanned re-interventions, while patients who survived to hospital discharge demonstrated favorable mortality, though with frequent need for re-intervention. In patients requiring early postoperative cardiac catheterization, renal failure, younger age, and need for inotropic support at catheterization are significantly associated with meeting the primary endpoint.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Criança , Humanos , Lactente , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
7.
Cardiol Young ; 33(11): 2395-2401, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37232082

RESUMO

Aortic arch stent placement in young children is a medical dilemma. This is attributed to the critical lack of commercially available stents that can be delivered through small sheaths and yet have the potential to be dilated to the adult-size aorta. Here in, we describe an innovative first-in-human technique that allows for overcoming the aforementioned challenges. A Palmaz Genesis XD stent was placed to treat coarctation of the aorta in two young children through small-bore sheaths.


Assuntos
Angioplastia com Balão , Coartação Aórtica , Criança , Humanos , Adulto , Pré-Escolar , Coartação Aórtica/cirurgia , Stents , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta , Angioplastia com Balão/métodos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 101(7): 1230-1234, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37070477

RESUMO

Left atrial appendage occlusion in young children has not been reported before. Herein, we describe a successful occlusion using hydrogel coils in a toddler. The decision to occlude the appendage was made to mitigate the potential risk of systemic thromboembolism, given the child's unusual anatomy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Tromboembolia , Humanos , Pré-Escolar , Apêndice Atrial/diagnóstico por imagem , Hidrogéis , Veia Cava Superior , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem
9.
World J Pediatr Congenit Heart Surg ; 14(2): 175-179, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36866595

RESUMO

There has been a paradigm shift in the management of patients with congenital heart disease with a move away from conventional surgical treatment in favor of a percutaneous catheter-based approach across the spectrum of valvular heart diseases. The Sapien S3 valve implantation in the pulmonary position has been previously reported using a conventional transcatheter approach in patients with pulmonary insufficiency due to an enlarged right ventricular outflow tract. In this report, we present 2 unique cases of intraoperative hybrid implantation of Sapien S3 valves in patients with complex pulmonic and tricuspid valvular disease.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Cateterismo Cardíaco/métodos , Catéteres , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Masculino , Feminino , Adolescente , Adulto
11.
Cardiol Young ; 33(3): 490-492, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35791267

RESUMO

Transcatheter intervention on the pulmonary vein often requires performing transseptal puncture, which is a risky procedure. We describe a rare association of a partially unroofed coronary sinus with pulmonary vein stenosis causing desaturation in a young infant where the presence of the unroofed coronary sinus allowed for a novel interventional approach to the stenotic left pulmonary vein, avoiding the high risk of transseptal puncture.


Assuntos
Seio Coronário , Anomalias dos Vasos Coronários , Comunicação Interatrial , Estenose de Veia Pulmonar , Malformações Vasculares , Humanos , Lactente , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Anomalias dos Vasos Coronários/complicações , Malformações Vasculares/complicações , Comunicação Interatrial/complicações
12.
Cardiol Young ; 33(5): 803-805, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36046984

RESUMO

Percutaneous transhepatic venous access has been utilised for numerous transcatheter cardiac procedures. Traditionally, a large transhepatic tract requires the placement of permanent occlusion devices or coils. We describe a successful closure using a simple technique (Surgifoam) without the need for metal hardware placement. Immediate hemostasis was achieved. No complications were encountered.


Assuntos
Gelatina , Hemostasia , Humanos , Resultado do Tratamento
13.
Pediatr Res ; 94(1): 213-221, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36380071

RESUMO

BACKGROUND: Definitive closure of the patent ductus arteriosus (PDA) is associated with significant changes in the loading conditions of the left ventricle (LV), which may lead to cardiovascular and respiratory instability. The objective of the study was to evaluate targeted neonatal echocardiography (TnECHO) characteristics and the clinical course of preterm infants ≤2 kg undergoing percutaneous PDA closure. METHODS: Retrospective cohort study of prospectively acquired pre- and post-closure TnECHOs to assess hemodynamic changes. Cardiorespiratory parameters in the first 24 h following PDA closure were also evaluated. RESULTS: Fifty patients were included with a mean age of 30.6 ± 9.6 days and weight of 1188 ± 280 g. LV global longitudinal strain decreased from -20.6 ± 2.6 to -14.9 ± 2.9% (p < 0.001) after 1 h. There was a decrease in LV volume loading, left ventricular output, LV systolic and diastolic parameters. Cardiorespiratory instability occurred in 24 (48%) [oxygenation failure in 44%] but systolic hypotension and/or need for cardiovascular medications was only seen in 6 (12%). Patients with instability had worse baseline respiratory severity score and lower post-closure early diastolic strain rates. CONCLUSIONS: Percutaneous PDA closure leads to a reduction in echocardiography markers of LV systolic/diastolic function. Post-closure cardiorespiratory instability is characterized primarily by oxygenation failure and may relate to impaired diastolic performance. IMPACT: Percutaneous patent ductus arteriosus closure leads to a reduction in echocardiography markers of left ventricular volume loading, cardiac output, and left ventricular systolic/diastolic function. Post-procedural cardiorespiratory instability is characterized primarily by oxygenation failure. Post-procedural cardiorespiratory instability may relate to impaired diastolic performance.


Assuntos
Permeabilidade do Canal Arterial , Insuficiência Respiratória , Lactente , Humanos , Recém-Nascido , Adulto Jovem , Adulto , Recém-Nascido Prematuro , Função Ventricular Esquerda , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/terapia , Estudos Retrospectivos , Ecocardiografia
14.
Catheter Cardiovasc Interv ; 101(1): 135-139, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36434791

RESUMO

The Harmony™ Transcatheter Pulmonary Valve (Medtronic) was recently approved by the Food and Drug Administration for transcatheter pulmonary valve replacement in native right ventricular outflow tracts. Despite this milestone, some patients have main pulmonary arteries that are severely dilated and continue to require surgical pulmonary valve replacement. The hybrid approach combines surgical creation of a landing zone, transcatheter valve deployment, and suture stabilization of the implanted valve. In this case series, we report the first use of a hybrid approach for Harmony™ transcatheter pulmonary valve replacement. Two cases are reported with varying approaches for surgical creation of a landing zone followed by successful placement of a Harmony™ valve.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Cateterismo Cardíaco , Desenho de Prótese
15.
J Am Heart Assoc ; 11(14): e026517, 2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35861815

RESUMO

Background Until recently, a large right ventricle outflow tract interfered with the feasibility of standard transcatheter pulmonary valve replacement (PVR). We are describing our experience using a hybrid approach for PVR using a left anterior thoracotomy approach to allow for plication of the main pulmonary artery followed by a transcatheter PVR using a Sapien S3 valve. Methods and Results This is a single-center, retrospective review of patients who were evaluated to be appropriate for a hybrid PVR approach. The patients' demographics, procedure details, and follow-up data were collected. Between May 2018 and April 2021, a total of 11 patients presented for hybrid transcatheter PVR. The median age and weight were 24 years (interquartile range, 19-43 years) and 81.8 kg (interquartile range, 69-91 kg), respectively. Nine out of 11 patients received a transcatheter PVR after main pulmonary artery plication. There were no procedurally related deaths. One major complication was encountered in which the valve was malpositioned requiring successful surgical PVR. Minor complications included acute kidney injury (n=1) and a broken rib (n=1). The median length of stay was 4 days (interquartile range, 2-4 days), with median follow-up of 7 months (interquartile range, 3-18 months). A well-functioning pulmonary valve was observed in all patients at the last follow-up. Conclusions A hybrid approach using left anterior thoracotomy with pulmonary artery plication followed by transcatheter Sapien S3 PVR provides a less-invasive option for patients with an enlarged right ventricular outflow tract. Preliminary results demonstrated this to be a safe option with good short-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Cateterismo Cardíaco/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração , Humanos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Tetralogia de Fallot/cirurgia , Toracotomia/efeitos adversos , Resultado do Tratamento
16.
J Am Heart Assoc ; 11(10): e025343, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35574958

RESUMO

Background Prolonged exposure to a hemodynamically significant patent ductus arteriosus (PDA) is associated with major morbidity, particularly in infants born at <27 weeks' gestation. High-frequency jet ventilation (HFJV) is a standard of care at our center. There are no data about transcatheter PDA closure while on HFJV. The aim of this study was to assess the feasibility, safety, and outcomes of HFJV during transcatheter PDA closure. Methods and Results This is a retrospective cohort study of premature infants undergoing transcatheter device closure on HFJV. The primary outcome was successful device placement. Secondary outcomes included procedure time, fluoroscopy time and dose, time off unit, device complications, need for escalation in respiratory support, and 7-day survival. Subgroup comparative evaluation of patients managed with HFJV versus a small cohort of patients managed with conventional mechanical ventilation was performed. Thirty-eight patients were included in the study. Median age and median weight at PDA device closure for the HFJV cohort were 32 days (interquartile range, 25.25-42.0 days) and 1115 g (interquartile range, 885-1310 g), respectively. There was successful device placement in 100% of patients. There were no device complications noted. The time off unit and the procedure time were not significantly different between the HFJV group and the conventional ventilation group. Infants managed by HFJV had shorter median fluoroscopy times (4.5 versus 6.1 minutes; P<0.05) and no increased risk of adverse respiratory outcomes. Conclusions Transcatheter PDA closure in premature infants on HFJV is a safe and effective approach that does not compromise device placement success rate and does not lead to secondary complications.


Assuntos
Permeabilidade do Canal Arterial , Ventilação em Jatos de Alta Frequência , Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Estudos de Viabilidade , Ventilação em Jatos de Alta Frequência/efeitos adversos , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Estudos Retrospectivos , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 15(9): 979-988, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35512922

RESUMO

OBJECTIVES: The aim of this study was to evaluate the accuracy of cardiac magnetic resonance (CMR) in predicting coronary artery (CA) compression during transcatheter pulmonary valve implantation (TPVi). BACKGROUND: TPVi is a widely available option to treat dysfunctional right ventricle (RV)-to-pulmonary artery (PA) conduits, but CA compression is an absolute contraindication. CMR can evaluate coronary anatomy, but its utility in predicting CA compression is not well established. METHODS: After Institutional Review Board approval was obtained, all patients at 9 centers with attempted TPVi in RV-PA conduits and recent CMR (≤12 months) were analyzed. A core laboratory reviewed all CMR studies for the shortest orthogonal distance from a CA to the conduit, the shortest distance from a CA to the most stenotic area of the conduit, and subjective assessment of CA compression risk. RESULTS: Among 231 patients, TPVi was successful in 198 (86%); in 24 (10%), balloon testing precluded implantation (documented CA compression or high risk). Distance to the RV-PA conduit ≤2.1 mm (area under the curve [AUC]: 0.70) and distance to most stenotic area ≤13.1 mm (AUC: 0.69) predicted CA compression. Subjective assessment had the highest AUC (0.78), with 96% negative predictive value. Both distances and qualitative assessment remained independently associated with CA compression when controlling for abnormal coronary anatomy or degree of conduit calcification. CONCLUSIONS: CMR can help predict the risk for CA compression during TPVi in RV-PA conduits but cannot completely exclude CA compression. CMR may assist in patient selection and counseling families prior to TPVi, although balloon testing remains essential.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Vasos Coronários , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
18.
Cardiol Young ; 31(10): 1696-1697, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33827730

RESUMO

In cases where femoral access is untenable for secundum atrial septal defect closure, the internal jugular vein can be used instead. We report a case of atrial septal defect closure in a patient with significant vascular thrombosis, requiring the use of the left internal jugular vein for access. To the best of our knowledge, this is the first report that documents the use of the left internal jugular vein for atrial septal defect closure in a patient with situs solitus anatomy.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Veias Braquiocefálicas , Cateterismo Cardíaco , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Humanos , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/cirurgia , Resultado do Tratamento
19.
Cardiol Young ; 31(9): 1525-1527, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33766174

RESUMO

Transcatheter closure of ventricular septal defects is considered first-line therapy when anatomically appropriate but is often challenged by proximity to the conduction system in perimembranous defects, or irregular defect shape, especially residual defects that may remain post-operatively. Advancements in device design, however, have allowed for significant improvements in deployment techniques and overall safety. Here we describe the first use of the Lifetech Konar-multifunction™ occluder device in North America, and our specific use of this device to close complex post-operative muscular and a perimembranous-ventricular septal defects in the same patient.


Assuntos
Comunicação Interventricular , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , Comunicação Interventricular/cirurgia , Humanos , América do Norte , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS