Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; : e2306038, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381100

RESUMO

Metabolites are essential molecules involved in various metabolic processes, and their deficiencies and excessive concentrations can trigger significant physiological consequences. The detection of multiple metabolites within a non-invasively collected biofluid could facilitate early prognosis and diagnosis of severe diseases. Here, a metal oxide heterojunction transistor (HJ-TFT) sensor is developed for the label-free, rapid detection of uric acid (UA) and 25(OH)Vitamin-D3 (Vit-D3) in human saliva. The HJ-TFTs utilize a solution-processed In2 O3 /ZnO channel functionalized with uricase enzyme and Vit-D3 antibody for the selective detection of UA and Vit-D3, respectively. The ultra-thin tri-channel architecture facilitates strong coupling between the electrons transported along the buried In2 O3 /ZnO heterointerface and the electrostatic perturbations caused by the interactions between the surface-immobilized bioreceptors and target analytes. The biosensors can detect a wide range of concentrations of UA (from 500 nm to 1000 µM) and Vit-D3 (from 100 pM to 120 nm) in human saliva within 60 s. Moreover, the biosensors exhibit good linearity with the physiological concentration of metabolites and limit of detections of ≈152 nm for UA and ≈7 pM for Vit-D3 in real saliva. The specificity is demonstrated against various interfering species, including other metabolites and proteins found in saliva, further showcasing its capabilities.

2.
Cureus ; 15(7): e41446, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37546032

RESUMO

The purpose of this report is to provide a comprehensive account of an exceptional case involving the presentation of congenital rubella syndrome (CRS) in a newborn. Furthermore, it aims to document the successful regression of CRS through medical treatment alone. We present the case of a five-day-old infant who was referred to our facility as a CRS case. The patient presented with bilateral white corneal opacity, which was observed shortly after birth. The mother was diagnosed as rubella-positive during pregnancy. Upon the initial examination under anesthesia, both eyes exhibited central white corneal opacity accompanied by large intrastromal cysts. Although a few breaks in Descemet's membrane were observed in both eyes, there were no signs of vascularization or the presence of iridocorneal or lenticular-corneal adhesions. After undergoing medical treatment consisting of topical sodium chloride and steroids, the cysts in both eyes completely regressed. Subsequently, the patient underwent penetrating keratoplasty to further address the dense scar. This case enhances our comprehension of ophthalmological complications associated with CRS and provides valuable insights into alternative therapeutic approaches for corneal stromal cysts.

3.
Biosens Bioelectron ; 237: 115448, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37348190

RESUMO

Transistor-based biosensors represent an emerging technology for inexpensive point-of-care testing (POCT) applications. However, the limited sensitivity of the current transistor technologies hinders their practical deployment. In this study, we developed tri-channel In2O3/ZnO heterojunction thin-film transistors (TFTs) featuring the surface-immobilized enzyme glucose oxidase to detect glucose in various biofluids. This unusual channel design facilitates strong coupling between the electrons transported along the buried In2O3/ZnO heterointerface and the electrostatic perturbations caused by the interactions between glucose and surface-immobilized glucose oxidase. The enzyme selectively binds to glucose, causing a change in charge density on the channel surface. By exploring this effect, the solid-state biosensing TFT (BioTFT) can selectively detect glucose in artificial and real saliva over a wide range of concentrations from 500 nM to 20 mM with limits of detection of ∼365 pM (artificial saliva) and ∼416 nM (real saliva) in less than 60 s. The specificity of the sensor towards glucose has been demonstrated against various interfering species in artificial saliva, further highlighting its unique capabilities. Moreover, the BioTFTs exhibited good operating stability upon storage for up to two weeks, with relative standard deviation (RSD) values ranging from 2.36% to 6.39% for 500 nM glucose concentration. Our BioTFTs are easy to manufacture with reliable operation, making them ideal for non-invasive POCT applications.


Assuntos
Técnicas Biossensoriais , Óxido de Zinco , Glucose , Saliva , Transistores Eletrônicos , Saliva Artificial , Glucose Oxidase , Óxidos
4.
Materials (Basel) ; 15(17)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36079529

RESUMO

This study aimed to measure the effect of storage environment on the hardness, surface roughness and wear ability of CAD/CAM resin-matrix ceramics. A total of 200 rectangular-shaped specimens were obtained by sectioning 5 CAD/CAM blocks; Crystal Ultra (CU), Vita Enamic (VE), Lava Ultimate (LU), Cerasmart (CS) and Vita blocks Mark II (MII). Microhardness and surface roughness were measured at baseline and after 7 days of immersion either in saliva or cola (n = 10). The wear ability of the CAD/CAM materials against steatite-ceramics antagonist was determined using a chewing simulator. The data were statistically analyzed using factorial ANOVA followed by post hoc Bonferroni multiple comparison tests (p < 0.05). The independent factors significantly influenced the microhardness and surface roughness (p < 0.05). The highest VHN was observed in MII at baseline (586.97 ± 13.95), while CU showed the lowest VHN after 7 days of immersion in cola (68.3 ± 1.89). On the contrary, the highest Ra was observed after 120,000 chewing cycles for the VE specimens (1.09 ± 0.43 µm) immersed in cola, while LU showed the lowest Ra at baseline (0.07 ± 0.01 µm). The highest % mass loss of the antagonist was observed with MII immersed in cola (1.801%), while CS demonstrated the lowest % mass loss of 0.004% and 0.007% in AS and cola, respectively. This study confirms that the surface properties of tested CAD/CAM materials are susceptible to degradation in an acidic environment except for hardness and wear of CS material.

5.
Adv Mater ; 34(3): e2104608, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34738258

RESUMO

Solid-state transistor sensors that can detect biomolecules in real time are highly attractive for emerging bioanalytical applications. However, combining upscalable manufacturing with the required performance remains challenging. Here, an alternative biosensor transistor concept is developed, which relies on a solution-processed In2 O3 /ZnO semiconducting heterojunction featuring a geometrically engineered tri-channel architecture for the rapid, real-time detection of important biomolecules. The sensor combines a high electron mobility channel, attributed to the electronic properties of the In2 O3 /ZnO heterointerface, in close proximity to a sensing surface featuring tethered analyte receptors. The unusual tri-channel design enables strong coupling between the buried electron channel and electrostatic perturbations occurring during receptor-analyte interactions allowing for robust, real-time detection of biomolecules down to attomolar (am) concentrations. The experimental findings are corroborated by extensive device simulations, highlighting the unique advantages of the heterojunction tri-channel design. By functionalizing the surface of the geometrically engineered channel with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody receptors, real-time detection of the SARS-CoV-2 spike S1 protein down to am concentrations is demonstrated in under 2 min in physiological relevant conditions.


Assuntos
Técnicas Biossensoriais/instrumentação , COVID-19/virologia , SARS-CoV-2/química , Glicoproteína da Espícula de Coronavírus/análise , Transistores Eletrônicos , Enzima de Conversão de Angiotensina 2/metabolismo , Anticorpos Imobilizados , Anticorpos Antivirais , Bioengenharia , COVID-19/sangue , COVID-19/diagnóstico , Teste para COVID-19/instrumentação , Teste para COVID-19/métodos , Simulação por Computador , Sistemas Computacionais , DNA/análise , Desenho de Equipamento , Humanos , Índio , Microtecnologia , Estudo de Prova de Conceito , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/metabolismo , Óxido de Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA