Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 509
Filtrar
1.
J Neurointerv Surg ; 2024 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-39438133

RESUMO

BACKGROUND: The patency of intracranial stents may not be reliably assessed with either CT angiography or MR angiography due to imaging artifacts. We investigated the potential of ultra-high resolution CT angiography using a photon counting detector (PCD) CT to address this limitation by optimizing scanning and reconstruction parameters. METHODS: A phantom with different flow diverters was used to optimize PCD-CT reconstruction parameters, followed by imaging of 14 patients with intracranial stents using PCD-CT. Images were reconstructed using three kernels based on the phantom results (Hv56, Hv64, and Hv72; Hv=head vascular) and one kernel to virtually match the resolution of standard CT angiography (Hv40). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were calculated. Subjective image quality and diagnostic confidence (DC) were assessed using a five point visual grading scale (5=best, 1=worst) and a three point grading scale (1=best, 3=worst), respectively, by two independent neuroradiologists. RESULTS: Phantom images demonstrated the highest image quality across dose levels for 0.2 mm reconstructions with Hv56 (4.5), Hv64 (5), and Hv72 (5). In patient images, SNR and CNR decreased significantly with increasing kernel sharpness compared with control parameters. All reconstructions showed significantly higher image quality and DC compared with the control reconstruction with Hv40 kernel (P<0.001), with both image quality and DC being highest with Hv64 (0.2 mm) and Hv72 (0.2 mm) reconstructions. CONCLUSION: Ultra-high resolution PDC-CT angiography provides excellent visualization of intracranial stents, with optimal reconstructions using the Hv64 and the Hv72 kernels at 0.2 mm. REGISTRATION: BASEC 2021-00343.

2.
Eur Radiol ; 2024 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-39424654

RESUMO

OBJECTIVES: To investigate the influence of kernels and iterative reconstructions on pericoronary adipose tissue (PCAT) attenuation in coronary CT angiography (CCTA). MATERIALS AND METHODS: Twenty otherwise healthy subjects (16 females; median age 52 years) with atypical chest pain, low risk of coronary artery disease (CAD), and without CAD in photon-counting detector CCTA were included. Images were reconstructed with a quantitative smooth (Qr36) and three vascular kernels of increasing sharpness levels (Bv36, Bv44, Bv56). Quantum iterative reconstruction (QIR) was either switched-off (QIRoff) or was used with strength levels 2 and 4. The fat-attenuation-index (FAI) of the PCAT surrounding the right coronary artery was calculated in each dataset. Histograms of FAI measurements were created. Intra- and inter-reader agreements were determined. A CT edge phantom was used to determine the edge spread function (ESF) for the same datasets. RESULTS: Intra- and inter-reader agreement of FAI was excellent (intra-class correlation coefficient = 0.99 and 0.98, respectively). Significant differences in FAI were observed depending on the kernel and iterative reconstruction strength level (each, p < 0.001), with considerable inter-individual variation up to 34 HU and intra-individual variation up to 33 HU, depending on kernels and iterative reconstruction levels. The ESFs showed a reduced range of edge-smoothing with increasing kernel sharpness, causing an FAI decrease. Histogram analyses revealed a narrower peak of PCAT values with increasing iterative reconstruction levels, causing a FAI increase. CONCLUSIONS: PCAT attenuation determined with CCTA heavily depends on kernels and iterative reconstruction levels both within and across subjects. Standardization of CT reconstruction parameters is mandatory for FAI studies to enable meaningful interpretations. KEY POINTS: Question Do kernels and iterative reconstructions influence pericoronary adipose tissue (PCAT) attenuation in coronary CT angiography (CCTA)? Findings Significant differences in fat-attenuation-index (FAI) were observed depending on the kernel and iterative reconstruction strength level with considerable inter- and intra-individual variation. Clinical relevance PCAT attenuation heavily depends on kernels and iterative reconstructions requiring CT reconstruction parameter standardization to enable meaningful interpretations of fat-attenuation differences across subjects.

4.
Radiol Cardiothorac Imaging ; 6(5): e240117, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39387666

RESUMO

Purpose To determine the prevalence of clinically relevant extracardiac findings at cardiac CT and MRI examinations from a multicenter, multinational MR/CT registry and the relationship of prevalence with examination indications and patient characteristics. Materials and Methods This was a retrospective analysis of data from the European Society of Cardiovascular Radiology MR/CT Registry. Data from 208 506 cardiac CT examinations (median patient age, 66 years [IQR, 55-77]; 121 617 [58.33%] male patients) and 228 462 cardiac MRI examinations (median patient age, 57 years [IQR, 42-69]; 145 792 [63.81%] male patients) entered into the registry between January 2011 and November 2023 were analyzed. Clinically relevant extracardiac findings were defined as findings requiring follow-up examinations or influencing clinical management. The association of examination indication and patient characteristics, including age, with prevalence of extracardiac findings was evaluated using incidence rate ratios (IRRs) derived from multivariable Poisson regression models. Results The prevalence of clinically relevant extracardiac findings was 3.28% (6832 of 208 506) at cardiac CT and 1.50% (3421 of 228 462) at cardiac MRI examinations. Extracardiac findings were more common at CT examinations performed for transcatheter aortic valve replacement (IRR, 2.07; P < .001) and structural heart disease (IRR, 1.44; P < .001) compared with CT performed for coronary artery disease (IRR, 1; reference). Extracardiac findings were more common at MRI examinations performed for myocarditis (IRR, 1.36; P < .001) and structural heart disease (IRR, 1.16; P < .001) than for coronary artery disease. Older patient age was also significantly associated with higher prevalence of extracardiac findings, with an IRR for both CT and MRI examinations of 1.02 (P < .001). Conclusion Data from the multicenter, multinational MR/CT registry indicate that clinically relevant extracardiac findings are present at cardiovascular CT and MRI examinations, and the prevalence of these findings is associated with examination indication and patient age. Keywords: Cardiac Imaging Techniques, Incidental Findings, MRI, CT Angiography, CT, Heart Disease Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imageamento por Ressonância Magnética , Sistema de Registros , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Europa (Continente)/epidemiologia , Estudos Retrospectivos , Feminino , Adulto , Achados Incidentais , Tomografia Computadorizada por Raios X , Prevalência , Técnicas de Imagem Cardíaca
5.
Artigo em Inglês | MEDLINE | ID: mdl-39240440

RESUMO

Non-invasive imaging with characterization and quantification of the myocardium with computed tomography (CT) became feasible owing to recent technical developments in CT technology. Cardiac CT can serve as an alternative modality when cardiac magnetic resonance imaging and/or echocardiography are contraindicated, not feasible, inconclusive, or non-diagnostic. This review summarizes the current and potential future role of cardiac CT for myocardial characterization including a summary of late enhancement techniques, extracellular volume quantification, and strain analysis. In addition, this review highlights potential fields for research about myocardial characterization with CT to possibly include it in clinical routine in the future.

6.
J Clin Med ; 13(17)2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39274260

RESUMO

Background/Objectives: The presence of late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) in patients with Fabry disease (FD) is a predictor of adverse cardiac events. The aim of this study was to establish the most reliable and reproducible technique for quantifying LGE in patients with FD. Methods: Twenty FD patients with LGE who underwent CMR on the same scanner and LGE sequence were included. LGE quantifications were done using gray-scale thresholds of 2, 3, 4, 5 and 6 standard deviations (SD) above the mean signal intensity of the remote myocardium, the full width at half maximum method (FWHM), visual assessment with threshold (VAT) and the fully manual method (MM). Results: The mean amount of fibrosis varied between quantification techniques from 36 ± 19 at 2SD to 2 ± 2 g using the FWHM (p < 0.0001). Intraobserver reliability was excellent for most methods, except for the FWHM which was good (ICC 0.84; all p < 0.05). Interobserver reliability was excellent for VAT (ICC 0.94) and good for other techniques (all p < 0.05). Intraobserver reproducibility showed the lowest coefficient of variation (CV, 6%) at 5SD and at 2SD and VAT (35% and 38%) for interobserver reproducibility. The FWHM revealed the highest CV (63% and 94%) for both intra- and interobserver reproducibility. Conclusions: The available methods for LGE quantification demonstrate good to excellent intra- and interobserver reproducibility in patients with FD. The most reliable and reproducible techniques were VAT and 5SD, whereas the FWHM was the least reliable in the setting of our study. The total amount of LGE varies strongly with the quantification technique used.

7.
Insights Imaging ; 15(1): 207, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39143413

RESUMO

Cardiovascular imaging is exponentially increasing in the diagnosis, risk stratification, and therapeutic management of patients with cardiovascular disease. The European Society of Cardiovascular Radiology (ESCR) is a non-profit scientific medical society dedicated to promoting and coordinating activities in cardiovascular imaging. The purpose of this paper, written by ESCR committees and Executive board members and approved by the ESCR Executive Board and Guidelines committee, is to codify a standardized approach to creating ESCR scientific documents. Indeed, consensus development methods must be adopted to ensure transparent decision-making that optimizes national and global health and reaches a certain scientific credibility. ESCR consensus documents developed based on a rigorous methodology will improve their scientific impact on the management of patients with cardiac involvement. CRITICAL RELEVANCE STATEMENT: This document aims to codify the methodology for producing consensus documents of the ESCR. These ESCR indications will broaden the scientific quality and credibility of further publications and, consequently, the impact on the diagnostic management of patients with cardiac involvement. KEY POINTS: Cardiovascular imaging is exponentially increasing for diagnosis, risk stratification, and therapeutic management. The ESCR is committed to promoting cardiovascular imaging. A rigorous methodology for ESCR consensus documents will improve their scientific impact.

8.
Insights Imaging ; 15(1): 208, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39143443

RESUMO

AIM: To determine the effectiveness of functional stress testing and computed tomography angiography (CTA) for diagnosis of obstructive coronary artery disease (CAD). METHODS AND RESULTS: Two-thousand nine-hundred twenty symptomatic stable chest pain patients were included in the international Collaborative Meta-Analysis of Cardiac CT consortium to compare CTA with exercise electrocardiography (exercise-ECG) and single-photon emission computed tomography (SPECT) for diagnosis of CAD defined as ≥ 50% diameter stenosis by invasive coronary angiography (ICA) as reference standard. Generalised linear mixed models were used for calculating the diagnostic accuracy of each diagnostic test including non-diagnostic results as dependent variables in a logistic regression model with random intercepts and slopes. Covariates were the reference standard ICA, the type of diagnostic method, and their interactions. CTA showed significantly better diagnostic performance (p < 0.0001) with a sensitivity of 94.6% (95% CI 92.7-96) and a specificity of 76.3% (72.2-80) compared to exercise-ECG with 54.9% (47.9-61.7) and 60.9% (53.4-66.3), SPECT with 72.9% (65-79.6) and 44.9% (36.8-53.4), respectively. The positive predictive value of CTA was ≥ 50% in patients with a clinical pretest probability of 10% or more while this was the case for ECG and SPECT at pretest probabilities of ≥ 40 and 28%. CTA reliably excluded obstructive CAD with a post-test probability of below 15% in patients with a pretest probability of up to 74%. CONCLUSION: In patients with stable chest pain, CTA is more effective than functional testing for the diagnosis as well as for reliable exclusion of obstructive CAD. CTA should become widely adopted in patients with intermediate pretest probability. SYSTEMATIC REVIEW REGISTRATION: PROSPERO Database for Systematic Reviews-CRD42012002780. CRITICAL RELEVANCE STATEMENT: In symptomatic stable chest pain patients, coronary CTA is more effective than functional testing for diagnosis and reliable exclusion of obstructive CAD in intermediate pretest probability of CAD. KEY POINTS: Coronary computed tomography angiography showed significantly better diagnostic performance (p < 0.0001) for diagnosis of coronary artery disease compared to exercise-ECG and SPECT. The positive predictive value of coronary computed tomography angiography was ≥ 50% in patients with a clinical pretest probability of at least 10%, for ECG ≥ 40%, and for SPECT 28%. Coronary computed tomography angiography reliably excluded obstructive coronary artery disease with a post-test probability of below 15% in patients with a pretest probability of up to 74%.

10.
AJR Am J Roentgenol ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39166723

RESUMO

Background: Pericoronary adipose tissue (PCAT) attenuation and fat attenuation index (FAI) may serve as markers of inflammation and risk of adverse cardiac events. However, standardization of relevant CT acquisition and reconstruction parameters is lacking. Objective: To investigate the influence of vessel attenuation, virtual monoenergetic image (VMI) level, and reconstruction kernel on PCAT attenuation and FAI using energy-integrating detector (EID) and photon-counting detector (PCD) CT systems in an ex-vivo porcine heart model. Methods: A porcine heart's right coronary artery (RCA) was injected with saline or varying contrast media dilutions to achieve vessel attenuations ranging from 0 to 1000 HU. After each injection, the heart was scanned with EID CT at 120 kVp and PCD CT at 140 kVp, at constant CTDIvol (10 mGy). For EID CT, polychromatic images were reconstructed with Qr40 kernel. For PCD CT, VMI (40-80 keV at 10-keV increments) were reconstructed with Qr40, Bv40, and Bv56 kernels. ROIs were placed to measure RCA and PCAT attenuation. FAI was determined using software; histogram analysis was performed of voxel attenuations in the volumes of interest for FAI calculation. Results: Correlations were observed between attenuation in the RCA and adjacent PCAT (r=0.3-1.0), and between vessel attenuation and FAI (r=-0.9-1.0). For PCAT attenuation and FAI, these associations became progressively weaker for progressively sharper kernels. For increasing vessel attenuation for EID CT and for increasing VMI level for PCD CT, FAI histograms showed right shifts of the peak attenuation; the percentage of histogram voxels meeting the threshold range for inclusion in FAI calculation for EID CT was 8-29% and for PCD CT at VMI levels of 70-80 keV was 5-42%. For PCD CT, sharper kernels were associated with left shifts in peak attenuations and greater percentages of voxels within the threshold range for inclusion in FAI calculations. Conclusion: PCAT attenuation and FAI are influenced by vessel lumen attenuation, VMI level, and reconstruction kernel. A minority of pericoronary voxels contribute to FAI measurements for polychromatic EID CT and for PCD CT at high VMI levels. Clinical Impact: These findings may help standardize acquisition and reconstruction parameters for PCAT attenuation and FAI measurements.

11.
Invest Radiol ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39074298

RESUMO

OBJECTIVES: The aim of this study was to evaluate the potential use of simulated radiation doses from a dual-split CT scan for dose optimization by comparing their lesion detectability to dose-matched single-energy CT acquisitions at different radiation dose levels using a mathematical model observer. MATERIALS AND METHODS: An anthropomorphic abdominal phantom with liver lesions (5-10 mm, both hyperattenuating and hypoattenuating) was imaged using a third-generation dual-source CT in single-energy dual-source mode at 100 kVp and 3 radiation doses (5, 2.5, 1.25 mGy). The tube current was 67% for tube A and 33% for tube B. For each dose, 5 simulated radiation doses (100%, 67%, 55%, 45%, 39%, and 33%) were generated through linear image blending. The phantom was also imaged using traditional single-source single-energy mode at equivalent doses. Each setup was repeated 10 times. Image noise texture was evaluated by the average spatial frequency (fav) of the noise power spectrum. Liver lesion detection was measured by the area under the receiver operating curve (AUC), using a channelized Hotelling model observer with 10 dense Gaussian channels. RESULTS: Fav decreased at lower radiation doses and differed between simulated and single-energy images (eg, 0.16 mm-1 vs 0.14 mm-1 for simulated and single-energy images at 1.25 mGy), indicating slightly blotchier noise texture for dual-split CT. For hyperattenuating lesions, the mean AUC ranged between 0.92-0.99, 0.81-0.96, and 0.68-0.89 for single-energy, and between 0.91-0.99, 0.78-0.91, and 0.70-0.85 for dual-split at 5 mGy, 2.5 mGy, and 1.25 mGy, respectively. For hypoattenuating lesions, the AUC ranged between 0.90-0.98, 0.75-0.93, and 0.69-0.86 for the single-energy, and between 0.92-0.99, 0.76-0.87, and 0.67-0.81 for dual-split at 5 mGy, 2.5 mGy, and 1.25 mGy, respectively. AUC values were similar between both modes at 5 mGy, and slightly lower, albeit not significantly, for the dual-split mode at 2.5 and 1.25 mGy. CONCLUSIONS: Lesion detectability was comparable between multiple simulated radiation doses from a dual-split CT scan and dose-matched single-energy CT. Noise texture was slightly blotchier in the simulated images. Simulated doses using dual-split CT can be used to assess the impact of radiation dose reduction on lesion detectability without the need for repeated patient scans.

12.
Eur J Radiol Open ; 12: 100574, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38882632

RESUMO

Purpose: To determine the value of an algorithm for reducing stair-step artifacts for advanced coronary analyses in sequential mode coronary CT angiography (CCTA). Methods: Forty patients undergoing sequential mode photon-counting detector CCTA with at least one stair-step artifact were included. Twenty patients (14 males; mean age 57±17years) with 45 segments showing stair-step artifacts and without atherosclerosis were included for CTFFR analysis. Twenty patients (20 males; mean age 74±13years) with 22 segments showing stair-step artifacts crossing an atherosclerotic plaque were included for quantitative plaque analysis. Artifacts were graded, and CTFFR and quantitative coronary plaque analyses were performed in standard reconstructions and in those reconstructed with a software (entitled ZeeFree) for artifact reduction. Results: Stair-step artifacts were significantly reduced in ZeeFree compared to standard reconstructions (p<0.05). In standard reconstructions, CTFFR was not feasible in 3/45 (7 %) segments but was feasible in all ZeeFree reconstructions. In 9/45 (20 %) segments without atherosclerosis, the ZeeFree algorithm led to a change of CTFFR values from pathologic in standard to physiologic values in ZeeFree reconstructions. In one segment (1/22, 5 %), quantitative plaque analysis was not feasible in standard but only in ZeeFree reconstruction. The mean overall plaque volume (111±60 mm3), the calcific (77±47 mm3), fibrotic (31±28 mm3), and lipidic (4±3 mm3) plaque components were higher in standard than in ZeeFree reconstructions (overall 75±50 mm3, p<0.001; calcific 51±42 mm3, p<0.001; fibrotic 22±19 mm3, p<0.05; lipidic 3±3 mm3, p=0.055). Conclusion: Despite the lack of reference standard modalities for CTFFR and coronary plaque analysis, initial evidence indicates that an algorithm for reducing stair-step artifacts in sequential mode CCTA increases the rate and quality of datasets amenable to advanced coronary artery analysis, hereby potentially improving patient management.

14.
Eur Radiol ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935123

RESUMO

OBJECTIVES: To assess the accuracy of a synthetic hematocrit derived from virtual non-contrast (VNC) and virtual non-iodine images (VNI) for myocardial extracellular volume (ECV) computation with photon-counting detector computed tomography (PCD-CT). MATERIALS AND METHODS: Consecutive patients undergoing PCD-CT including a coronary CT angiography (CCTA) and a late enhancement (LE) scan and having a blood hematocrit were retrospectively included. In the first 75 patients (derivation cohort), CCTA and LE scans were reconstructed as VNI at 60, 70, and 80 keV and as VNC with quantum iterative reconstruction (QIR) strengths 2, 3, and 4. Blood pool attenuation (BPmean) was correlated to blood hematocrit. In the next 50 patients (validation cohort), synthetic hematocrit was calculated using BPmean. Myocardial ECV was computed using the synthetic hematocrit and compared with the ECV using the blood hematocrit as a reference. RESULTS: In the derivation cohort (49 men, mean age 79 ± 8 years), a correlation between BPmean and blood hematocrit ranged from poor for VNI of CCTA at 80 keV, QIR2 (R2 = 0.12) to moderate for VNI of LE at 60 keV, QIR4; 70 keV, QIR3 and 4; and VNC of LE, QIR3 and 4 (all, R2 = 0.58). In the validation cohort (29 men, age 75 ± 14 years), synthetic hematocrit was calculated from VNC of the LE scan, QIR3. Median ECV was 26.9% (interquartile range (IQR), 25.5%, 28.8%) using the blood hematocrit and 26.8% (IQR, 25.4%, 29.7%) using synthetic hematocrit (VNC, QIR3; mean difference, -0.2%; limits of agreement, -2.4%, 2.0%; p = 0.33). CONCLUSION: Synthetic hematocrit calculated from VNC images enables an accurate computation of myocardial ECV with PCD-CT. CLINICAL RELEVANCE STATEMENT: Virtual non-contrast images from cardiac late enhancement scans with photon-counting detector CT allow the calculation of a synthetic hematocrit, which enables accurate computation of myocardial extracellular volume. KEY POINTS: Blood hematocrit is mandatory for conventional myocardial extracellular volume computation. Synthetic hematocrit can be calculated from virtual non-iodine and non-contrast photon-counting detector CT images. Synthetic hematocrit from virtual non-contrast images enables computation of the myocardial extracellular volume.

15.
Invest Radiol ; 59(10): 684-690, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38742928

RESUMO

OBJECTIVE: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. MATERIALS AND METHODS: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. RESULTS: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy ( R2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. CONCLUSIONS: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Meios de Contraste , Angiografia Coronária , Imagens de Fantasmas , Meios de Contraste/administração & dosagem , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/métodos , Fótons , Cálcio , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
16.
Eur Radiol ; 34(11): 7264-7274, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38703188

RESUMO

OBJECTIVES: To compare the repeatability and interrelation of various late gadolinium enhancement (LGE) assessment techniques for monitoring fibrotic changes in myocarditis follow-up. MATERIALS AND METHODS: LGE extent change between baseline and 3-month cardiovascular magnetic resonance (CMR) was compared in patients with acute myocarditis using the full width at half maximum (FWHM), gray-scale thresholds at 5 and 6 standard deviations (SD5 and SD6), visual assessment with threshold (VAT) and full manual (FM) techniques. In addition, visual presence score (VPS), visual transmurality score (VTS), and a simplified visual change score (VCS) were assessed. Intraclass-correlation (ICC) was used to evaluate repeatability, and methods were compared using Spearman's correlation. RESULTS: Forty-seven patients (38 male, median age: 27 [IQR: 21; 38] years) were included. LGE extent change differed among quantitative techniques (p < 0.01), with variability in the proportion of patients showing LGE change during follow-up (FWHM: 62%, SD5: 74%, SD6: 66%, VAT: 43%, FM: 60%, VPS: 53%, VTS: 77%, VCS: 89%). Repeatability was highest with FWHM (ICC: 0.97) and lowest with SD5 (ICC: 0.89). Semiquantitative scoring had slightly lower values (VPS ICC: 0.81; VTS ICC: 0.71). VCS repeatability was excellent (ICC: 0.93). VPS and VTS correlated with quantitative techniques, while VCS was positively associated with VPS, VTS, VAT, and FM, but not with FWHM, SD5, and SD6. CONCLUSION: FWHM offers the least observer-dependent LGE follow-up after myocarditis. VPS, VTS, and VCS are practical alternatives, showing reliable correlations with quantitative methods. Classification of patients exhibiting either stable or changing LGE relies on the assessment technique. CLINICAL RELEVANCE STATEMENT: This study shows that LGE monitoring in myocarditis is technique-dependent; the FWHM method yields the most consistent fibrotic tracking results, with scoring-based techniques as reliable alternatives. KEY POINTS: Recognition of fibrotic changes during myocarditis follow-up is significantly influenced by the choice of the quantification technique employed. The FWHM technique ensures highly repeatable tracking of myocarditis-related LGE changes. Segment-based visual scoring and the simplified visual change score offer practical, reproducible alternatives in resource-limited settings.


Assuntos
Meios de Contraste , Fibrose , Gadolínio , Miocardite , Humanos , Masculino , Miocardite/diagnóstico por imagem , Feminino , Adulto , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Seguimentos , Adulto Jovem
17.
Sci Rep ; 14(1): 12526, 2024 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822074

RESUMO

Transcatheter aortic valve replacement (TAVR) is a widely used intervention for patients with severe aortic stenosis. Identifying high-risk patients is crucial due to potential postprocedural complications. Currently, this involves manual clinical assessment and time-consuming radiological assessment of preprocedural computed tomography (CT) images by an expert radiologist. In this study, we introduce a probabilistic model that predicts post-TAVR mortality automatically using unprocessed, preprocedural CT and 25 baseline patient characteristics. The model utilizes CT volumes by automatically localizing and extracting a region of interest around the aortic root and ascending aorta. It then extracts task-specific features with a 3D deep neural network and integrates them with patient characteristics to perform outcome prediction. As missing measurements or even missing CT images are common in TAVR planning, the proposed model is designed with a probabilistic structure to allow for marginalization over such missing information. Our model demonstrates an AUROC of 0.725 for predicting all-cause mortality during postprocedure follow-up on a cohort of 1449 TAVR patients. This performance is on par with what can be achieved with lengthy radiological assessments performed by experts. Thus, these findings underscore the potential of the proposed model in automatically analyzing CT volumes and integrating them with patient characteristics for predicting mortality after TAVR.


Assuntos
Estenose da Valva Aórtica , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Masculino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Idoso
18.
Eur Radiol ; 34(10): 6559-6567, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38625611

RESUMO

Stable chest pain is a common symptom with multiple potential causes. Non-invasive imaging has an important role in diagnosis and guiding management through the assessment of coronary stenoses, atherosclerotic plaque, myocardial ischaemia or infarction, and cardiac function. Computed tomography (CT) provides the anatomical evaluation of coronary artery disease (CAD) with the assessment of stenosis, plaque type and plaque burden, with additional functional information available from CT fractional flow reserve (FFR) or CT myocardial perfusion imaging. Stress magnetic resonance imaging, nuclear stress myocardial perfusion imaging, and stress echocardiography can assess myocardial ischaemia and other cardiac functional parameters. Coronary CT angiography can be used as a first-line test for many patients with stable chest pain, particularly those with low to intermediate pre-test probability. Functional testing may be considered for patients with known CAD, where the clinical significance is uncertain based on anatomical testing, or in patients with high pre-test probability. This practice recommendations document can be used to guide the selection of non-invasive imaging for patients with stable chest pain and provides brief recommendations on how to perform and report these diagnostic tests. KEY POINTS: The selection of non-invasive imaging tests for patients with stable chest pain should be based on symptoms, pre-test probability, and previous history. Coronary CT angiography can be used as a first-line test for many patients with stable chest pain, particularly those with low to intermediate pre-test probability. Functional testing can be considered for patients with known CAD, where the clinical significance of CAD is uncertain based on anatomical testing, or in patients with high pre-test probability. KEY RECOMMENDATIONS: Non-invasive imaging is an important part of the assessment of patients with stable chest pain. The selection of non-invasive imaging test should be based on symptoms, pre-test probability, and previous history. (Level of evidence: High). Coronary CT angiography can be used as a first line test for many patients with stable chest pain, particularly those with low to intermediate pre-test probability. CT provides information on stenoses, plaque type, plaque volume, and if required functional information with CT fractional flow reserve or CT perfusion. (Level of evidence: High). Functional testing can be considered for patients with known CAD, where the clinical significance of CAD is uncertain based on anatomical testing, or in patients with high pre-test probability. Stress MRI, SPECT, PET, and echocardiography can provide information on myocardial ischemia, along with cardiac functional and other information. (Level of evidence: Medium).


Assuntos
Dor no Peito , Humanos , Dor no Peito/diagnóstico por imagem , Dor no Peito/etiologia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Imageamento por Ressonância Magnética/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Tomografia Computadorizada por Raios X/métodos , Imagem de Perfusão do Miocárdio/métodos
19.
Acad Radiol ; 31(9): 3650-3656, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38641450

RESUMO

RATIONALE AND OBJECTIVES: To evaluate and compare the effectiveness of contrast media subtraction and kidney stone detection between a virtual non-iodine reconstruction algorithm (VNI; PureCalcium) and a virtual non-contrast (VNC) algorithm in excretory phase photon-counting detector computed tomography (PCD-CT), using a 3D printed kidney phantom under various tube voltages and radiation doses. MATERIALS AND METHODS: A 3D-printed kidney phantom, holding Calcium Oxalate (CaOx) and uric acid stones within contrast-enhanced calyces, was created. The calyx density mirrored the average density observed in 200 excretory phase patients (916 HU at 110 kV). Imaging was conducted on a clinical dual-source PCD-CT at 120 kV and 140 kV, with radiation doses set at 5, 10, and 15 mGy. VNI and VNC algorithms were applied. Two blinded readers evaluated the image quality, along with the degree of contrast media and kidney stone subtraction, using visual scales. Krippendorff's alpha was calculated to determine inter-reader agreement, and the Chi-squared test was employed for comparing ordinal data. RESULTS: Reader 2 rated overall image quality higher for VNI than VNC (4.90 vs. 4.00; P < .05), while Reader 1 found no significant difference (4.96 vs. 5.00; P > .05). Substantial agreement was observed between readers for contrast media subtraction in both VNC and VNI (Krippendorff's alpha range: 0.628-0.748). Incomplete contrast media subtraction occurred more frequently with VNI for both readers (Reader 1: 29% vs. 15%; P < .05; Reader 2: 24% vs. 20%; P > .05). Uric acid and smaller stones (<5 mm) were more likely to be subtracted than CaOx and larger stones in both VNC and VNI. Overall, a higher rate of stone subtraction was noted with VNI compared to VNC (Reader 1: 22% vs. 16%; Reader 2: 25% vs. 10%; P < .05). Neither radiation dose nor tube voltage significantly influenced stone subtraction (P > .05). CONCLUSION: VNC demonstrated greater accuracy than VNI for contrast media subtraction and kidney stone visibility. Radiation dose and tube voltage had no significant impact. Nonetheless, both algorithms still exhibited frequent incomplete contrast media subtraction and partial kidney stone subtraction.


Assuntos
Algoritmos , Meios de Contraste , Cálculos Renais , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/química , Humanos , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fótons , Doses de Radiação
20.
Invest Radiol ; 59(10): 677-683, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38526041

RESUMO

OBJECTIVES: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. MATERIALS AND METHODS: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. RESULTS: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions ( R2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. CONCLUSIONS: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as-in distinction to iodine-both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Meios de Contraste , Iodo , Imagens de Fantasmas , Tungstênio , Meios de Contraste/química , Angiografia por Tomografia Computadorizada/métodos , Humanos , Angiografia Coronária/métodos , Fótons , Vasos Coronários/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA