Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Voice ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38195335

RESUMO

BACKGROUND: Sulcus vocalis reflects varying degrees of vocal cord lamina propria (LP) damage. Many interventions have been discussed in the literature for addressing sulcus vocalis, but there is no universally accepted gold standard for its management. AIM: We aim in our study to collectively evaluate the effectiveness of different relevant interventions in the literature used for sulcus vocalis or vocal fold scar. METHODS: We searched five electronic databases to collect all relevant studies. Records were screened for eligibility. Data were extracted from the included studies independently. Our continuous outcomes were pooled in our single-arm meta-analysis as mean change (MC) and with 95% confidence interval (CI). RESULTS: Our systematic review and meta-analysis included 43 studies encompassing 1302 patients. The jitter parameter indicated that laser degeneration and LP regeneration/scar degradation led to the highest improvements compared to their baseline, with pooled MC of -0.897 and -0.893, respectively. Graft interposition showed a MC of -0.848, while medialization and dissection had less pronounced changes at -0.200. Shimmer parameter results were similar, with medialization and laser degeneration leading to MC of -2.129 and -2.123, while LP regeneration/scar degradation and graft interposition showed smaller changes MC -1.530 and -1.217. For the noise-to-harmonic ratio (NHR) parameter, LP regeneration/scar degradation demonstrated MC = -0.028. In aerodynamics outcomes, graft interposition and LP regeneration/scar degradation showed the highest MCs in mean phonatory time (MPT) (4.214 and 3.467, respectively). Endoscopic outcomes for mucosal wave showed high improvements in medialization and graft interposition (MC = 10.40 and 10.18, respectively). Perceptual outcomes favored graft interposition in various parameters, while laser degeneration performed well in most categories. Graft interposition and LP regeneration/scar degradation had a high voice handicap index (VHI) (MC = -27.195 and -19.269, respectively). CONCLUSION: Laser degeneration and LP regeneration/scar degradation were particularly effective in improving acoustic parameters. In aerodynamics, graft interposition and LP regeneration/scar degradation improved vocal efficiency compared to their baselines. Medialization and laser degeneration had the largest impact compared to their baseline on shimmer and MPT. Endoscopic assessments showed that medialization and graft interposition had high improvement in mucosal waves, and perceptual outcomes were generally high with graft interposition and laser degeneration.

2.
Eur Arch Otorhinolaryngol ; 281(1): 13-21, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37709923

RESUMO

OBJECTIVES: To evaluate the efficacy of platelet-rich plasma (PRP) in benign vocal fold lesions. METHODS: MEDLINE, Cochrane Central, Web of Science, and Scopus databases were searched in April 2023 for relevant clinical trials. Inclusion criteria were clinical trials evaluating the efficacy of PRP in benign vocal fold lesions. We conducted a comparative double-arm analysis using the pooled mean difference (MD) and 95% confidence interval (CI). Outcomes of interest included the vocal handicap index (VHI), the Jitter and Shimmer percentages, and the noise-to-harmonic ratio (NHR). RESULTS: Six studies matched the inclusion criteria. The pooled analysis shows that PRP was associated with significantly lower VHI scores compared with the control (MD = - 5.06, p < 0.01). Regarding the Jitter percentage, the PRP group was not superior to the control group at 2 and 4 weeks. However, the results revealed that PRP significantly reduced the Jitter percentage at 3 months (MD = - 0.61, p = 0.0008). The overall analysis favored the PRP arm significantly (p < 0.001). As for the Shimmer percentage, the combined effect estimate favored the PRP group (MD = - 1.22, p = 0.002). Subgroup analysis according to the time did not reveal any significant differences between studies at 2 weeks, 4 weeks, and 3 months. The analysis of the NHR outcome revealed a significant difference between both groups (MD = -1.09, p = 0.01). However, at 4 weeks, the treatment group had a significantly lower NHR % compared to the control group (MD = - 0.61, p = 0.02). There was no significant difference at 3 months (MD = - 2.14, p = 0.14). CONCLUSIONS: Platelet-rich plasma is effective in reducing VHI scores, Jitter and Shimmer percentages, and NHR values. This effect is more evident after follow-up, especially 3 months.


Assuntos
Plasma Rico em Plaquetas , Prega Vocal , Humanos , Resultado do Tratamento
3.
Eur Arch Otorhinolaryngol ; 281(5): 2211-2222, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38158419

RESUMO

PURPOSE: To provide a comprehensive review of the current strategies in the management of laryngeal hemangiomas, with an aim to introduce a management algorithm that aligns with the variable clinical presentations and anatomical complexities of these lesions. METHODS: We conducted an extensive literature search across major databases using specific and general terms, combined with Boolean operators, to ensure comprehensiveness. Articles from January 2004 to August 2023 were included, with findings categorized by management approach. RESULTS: Laryngeal hemangiomas exhibit a spectrum of manifestations, ranging from asymptomatic lesions to those causing severe airway obstruction. Optimal management demands an individualized approach tailored to the patient's unique presentation and anatomical considerations. Diverse treatment modalities, each with distinct indications, advantages, and limitations, are explored. Notable highlights encompass the prominent role of Beta-blockers, notably Propranolol, in addressing problematic infantile hemangiomas, the nuanced efficacy of laser therapies contingent upon hemangioma type and depth, and the critical relevance of tracheotomy in emergencies. Novel approaches like transoral robotic surgery and transoral ultrasonic surgery, demonstrate promise in specific scenarios. We propose a management algorithm based on the complexity and presentation of laryngeal hemangiomas, emphasizing individualized treatment strategies, thereby addressing the unique challenges and nuances of each case. CONCLUSION: Laryngeal hemangioma management requires personalized approaches informed by diverse therapies, clinical expertise, and collaboration. The review introduces an algorithm spanning observation to advanced interventions, adapting to each case's complexity. Ongoing research promises innovative treatments.


Assuntos
Hemangioma , Neoplasias Laríngeas , Humanos , Antagonistas Adrenérgicos beta/uso terapêutico , Hemangioma/terapia , Hemangioma/tratamento farmacológico , Neoplasias Laríngeas/terapia , Neoplasias Laríngeas/tratamento farmacológico , Propranolol/uso terapêutico , Traqueostomia , Resultado do Tratamento
4.
J Voice ; 2023 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-37433707

RESUMO

BACKGROUND: The Reflux Symptom Score (RSS) is a patient-related outcomes measure (PROM) that was developed to diagnose Laryngopharyngeal reflux (LPR), by assessing the severity and frequency of specific symptoms and their respective impact on quality of life (QoL). OBJECTIVE: To develop the Arabic version of RSS-12 (Ar-RSS-12), and to assess its validity and reliability. METHOD: The RSS-12 was translated from French into Arabic using the forward-backward translation method, and the translated version underwent transcultural validation. A case-control study was conducted at the otolaryngology clinics of a referral hospital, during the period November to December 2022. It included 61 patients with LPR-related symptoms and a Reflux Symptom Index (RSI) score >13, and 61 control without LPR-related symptoms and negative RSI scores ≤13. The internal consistency, internal and external validity, and Test-Retest reliability of Ar-RSS-12 were analyzed. RESULT: Patients had significantly higher scores than controls in all 12 items and total Ar-RSS and QoL impact scores, with high Z score values. Item scores showed variable correlation levels with total Ar-RSS score, with ear-nose-throat items showing the strongest correlation (Spearman's rho 0.592-0.866). The QoL scores were more strongly correlated to the symptoms' severity than frequency. The internal consistency was high, with Cronbach's alpha = 0.878. Regarding external validity, correlations with RSI score showed high Spearman's rho values for total Ar-RSS (0.905) and QoL total score (0.903). No statistically significant difference was observed between Test and Retest results in any of the 12 items' score or the total score and QoL, indicating the reproducibility of the test. CONCLUSION: The Ar-RSS is a valid and reproducible tool for the screening, assessment, and monitoring of LPR in Arabic speaking patients. The inclusion of symptoms severity and frequency, as well as their individual effects on patient's QoL, support the superior clinical applications of RSS compared to other existing PROMs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA