Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Med ; 13(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38999202

RESUMO

Transcatheter aortic valve implantation (TAVI) now represents the mainstay of treatment for severe aortic stenosis. Owing to its exceptional procedural efficacy and safety, TAVI has been extended to include patients at lower surgical risk, thus now encompassing a diverse patient population receiving this treatment. Yet, long-term outcomes also depend on optimal medical therapy for secondary vascular prevention, with antithrombotic therapy serving as the cornerstone. Leveraging data from multiple randomized controlled trials, the current guidelines generally recommend single antithrombotic therapy, with either single antiplatelet therapy (SAPT) or oral anticoagulation (OAC) alone in those patients without or with atrial fibrillation, respectively. Yet, individualization of this pattern, as well as specific case uses, may be needed based on individual patient characteristics and concurrent procedures. This review aims to discuss the evidence supporting antithrombotic treatments in patients treated with TAVI, indications for a standardized treatment, as well as specific considerations for an individualized approach to treatment.

2.
Int J Cardiol ; 345: 29-35, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34610357

RESUMO

BACKGROUND: Isolated atrial fibrillation can cause mitral regurgitation (MR) in patients with normal left ventricular systolic function and no organic disease of the mitral valve. Little information is available regarding outcomes of Mitraclip in patients with atrial functional mitral regurgitation (AFMR). We aimed to evaluate 12-month clinical and echocardiographic outcomes of transcatheter mitral valve repair (TMVR) with MitraClip in patients with AFMR compared to those with ventricular functional or degenerative/mixed MR. METHODS: Registry-based analysis of all consecutive patients who underwent TMVR and were included in the Spanish Registry of Mitraclip. Changes in MR and NYHA functional class, and a combined endpoint including all-cause mortality and hospitalizations due to heart failure were the main outcomes. RESULTS: Overall, 1074 (69.1% male, 73.3 ± 10.2 years-old) patients were analyzed in this report. 48 patients (4.5%) presented AFMR. AFMR was significantly reduced after TMVR, with a procedural success rate of 91.7%, and this reduction persisted at 12-month (p < 0.001). Patients with AFMR showed a significant functional improvement at 6- and 12-month follow-up in our series (baseline: NYHA III 70.8% IV 18.8% vs. 1-year: NYHA III 21.7% IV 0%; p < 0.001). The probability of survival free of readmission for heart failure and all-cause mortality within the first year after TMVR was 74.9%. Procedural and clinical outcomes, as well as recurrent rates of MR were similar acutely and at 1-year compared to other etiologies. CONCLUSION: TMVR in patients with AFMR showed no significant differences compared to ventricular functional or degenerative/mixed MR regarding MR reduction or clinical outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Ecocardiografia , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
3.
J Clin Med ; 10(4)2021 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-33668494

RESUMO

The majority of familial hypercholesterolemia index cases (FH-IC) remain underdiagnosed and undertreated because there are no well-defined strategies for the universal detection of FH. The aim of this study was to evaluate the diagnostic yield of an active screening for FH-IC based on centralized analytical data. From 2016 to 2019, a clinical screening of FH was performed on 469 subjects with severe hypercholesterolemia (low-density lipoprotein cholesterol ≥220 mg/dL), applying the Dutch Lipid Clinic Network (DLCN) criteria. All patients with a DLCN ≥ 6 were genetically tested, as were 10 patients with a DLCN of 3-5 points to compare the diagnostic yield between the two groups. FH was genetically confirmed in 57 of the 84 patients with DLCN ≥ 6, with a genetic diagnosis rate of 67.9% and an overall prevalence of 12.2% (95% confidence interval: 9.3% to 15.5%). Before inclusion in the study, only 36.8% (n = 21) of the patients with the FH mutation had been clinically diagnosed with FH; after genetic screening, FH detection increased 2.3-fold (p < 0.001). The sequential, active screening strategy for FH-IC increases the diagnostic yield for FH with a rational use of the available resources, which may facilitate the implementation of FH universal and family-based cascade screening strategies.

4.
EuroIntervention ; 12(16): 1962-1968, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-27973334

RESUMO

AIMS: The aim of the study was to assess the safety and efficacy of percutaneous closure of paravalvular prosthetic leak (PVL) and to identify the predictors of procedural success and early complications. METHODS AND RESULTS: A total of 514 first-attempt percutaneous PVL closure in 469 patients were included at 19 centres. Technical and procedural success was achieved in 86.6% and 73.2% of the patients, respectively. In multivariate analysis, the independent predictors for procedural success in mitral lesions were the type of device used (AMPLATZER AVP III vs. others, HR 2.68 [1.29-5.54], p=0.008) and the number of procedures performed at the centre (top quartile vs. others, HR 1.93 [1.051-3.53], p=0.03). For aortic leaks the only predictor of procedural success was the leak size (≥10 mm vs. <10 mm, HR 3.077 [1.13-8.33], p=0.027). The overall major adverse events rate (death or emergency surgery or stroke) at 30 days was 5.6%; the only predictor for combined adverse events was New York Heart Association functional Class IV (HR 4.2 [1.42-12.34], p=0.009). CONCLUSIONS: Percutaneous closure of PVL can be performed with a reasonable rate of procedural success and a low rate of major complications. The type of device used, the accumulated experience and the leak size are predictors of procedural success.


Assuntos
Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias , Sistema de Registros , Dispositivo para Oclusão Septal , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional/métodos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
5.
J Anat ; 229(5): 703-709, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27345017

RESUMO

A previous manuscript [Fernández B, et al. (2008) J Anat 212, 12] reported on the unusual coronary artery patterns in mice belonging to the C57BL/6 strain. The aim here was to elucidate whether this pattern is unique to C57BL/6 mice or appears in other laboratory mouse strains and in wild-living mice. Stereomicroscopy, scanning electron microscopy, light microscopy and a corrosion cast technique were used to examine 597 adult mice belonging to three inbred strains (C57BL/6, Balb/c, DBA/2), three outbred stocks (CD1, OF1, NMRI) two hybrid lines (129sv × BL/6, CD2F1) and wild mice. It was shown that lock-like ostium is an exclusive trait of C57BL/6 mice, whereas left septal artery, accessory ostium, high take-off, intramural course and solitary ostium in aorta are all present in the different laboratory strains and wild mice included in the present study. However, each mouse population shows a specific incidence of these coronary conditions. Several clinically relevant human coronary artery anomalies are present in healthy mice from different strains that may serve as animal models for humans. These results should be taken into consideration in research concerning the murine coronary system, especially in coronary artery occlusion experiments and in studies on cardiovascular developmental biology using murine mutant lines.


Assuntos
Vasos Coronários/anatomia & histologia , Camundongos Endogâmicos C57BL/anatomia & histologia , Camundongos Endogâmicos/anatomia & histologia , Animais , Camundongos
6.
Rev Esp Cardiol (Engl Ed) ; 67(12): 1007-12, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25432711

RESUMO

INTRODUCTION AND OBJECTIVES: Symptomatic mitral regurgitation has an unfavorable prognosis unless treated by surgery. However, the European registry of valvular heart disease reports that 49% of patients with this condition do not undergo surgery. Percutaneous treatment of mitral regurgitation with MitraClip® has been proved a safe, efficient adjunct to medical treatment in patients with this profile. The objective of the present study is to describe initial experience of MitraClip® therapy in Spain. METHODS: Retrospective observational study including all patients treated between November 2011 and July 2013 at the 4 Spanish hospitals recording the highest numbers of implantations. RESULTS: A total of 62 patients (77.4% men) were treated, mainly for restrictive functional mitral regurgitation (85.4%) of grade III (37%) or grade IV (63%), mean (standard deviation) ejection fraction 36% (14%), and New York Heart Association functional class III (37%) or IV (63%). Device implantation was successful in 98% of the patients. At 1 year, 81.2% had mitral regurgitation ≤ 2 and 90.9% were in New York Heart Association functional class ≤ II. One periprocedural death occurred (sepsis at 20 days post-implantation) and another 3 patients died during follow-up (mean, 9.1 months). Two patients needed a second implantation due to partial dehiscence of the first device and 2 others underwent heart transplantation. CONCLUSIONS: In Spain, MitraClip® therapy has principally been aimed at patients with functional mitral regurgitation, significant systolic ventricular dysfunction, and high surgical risk. It is considered a safe alternative treatment, which can reduce mitral regurgitation and improve functional capacity.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Ecocardiografia Tridimensional/métodos , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Estudos Retrospectivos , Espanha , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA