Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Endosc Int Open ; 12(4): E498-E506, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38585021

RESUMO

Background and study aims Digital single-operator cholangioscopy (DSOC) allows the diagnosis of biliary duct disorders and treatment for complicated stones. However, these technologies have limitations such as the size of the probe and working channel, excessive cost, and low image resolution. Recently, a novel DSOC system (eyeMAX, Micro-Tech, Nanjing, China) was developed to address these limitations. We aimed to evaluate the usefulness and safety of a novel 9F and 11F DSOC system in terms of neoplastic diagnostic accuracy based on visual examination, ability to evaluate tumor extension and to achieve complete biliary stone clearance, and procedure-related adverse events (AEs). Patients and methods Data from ≥ 18-year-old patients who underwent DSOC from July 2021 to April 2022 were retrospectively recovered and divided into a diagnostic and a therapeutic cohort. Results A total of 80 patients were included. In the diagnostic cohort (n = 49/80), neovascularity was identified in 26 of 49 patients (46.9%). Biopsy was performed in 65.3% patients with adequate tissue sample obtained in 96.8% of cases. Biopsy confirmed neoplasia in 23 of 32 cases. DSOC visual impression achieved 91.6% sensitivity and 87.5% specificity in diagnosing neoplasms. In the therapeutic cohort (n = 43/80), 26 of 43 patients required lithotripsy alone. Total stone removal was achieved in 71% patients in the first session. Neither early nor late AEs were documented in either the diagnostic or therapeutic cohort. Conclusions The novel DSOC device has excellent diagnostic accuracy in distinguishing neoplastic biliary lesions as well as therapeutic benefits in the context of total stone removal, with no documented AEs.

2.
Endoscopy ; 55(8): 719-727, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36781156

RESUMO

BACKGROUND: We aimed to develop a convolutional neural network (CNN) model for detecting neoplastic lesions during real-time digital single-operator cholangioscopy (DSOC) and to clinically validate the model through comparisons with DSOC expert and nonexpert endoscopists. METHODS: In this two-stage study, we first developed and validated CNN1. Then, we performed a multicenter diagnostic trial to compare four DSOC experts and nonexperts against an improved model (CNN2). Lesions were classified into neoplastic and non-neoplastic in accordance with Carlos Robles-Medranda (CRM) and Mendoza disaggregated criteria. The final diagnosis of neoplasia was based on histopathology and 12-month follow-up outcomes. RESULTS: In stage I, CNN2 achieved a mean average precision of 0.88, an intersection over the union value of 83.24 %, and a total loss of 0.0975. For clinical validation, a total of 170 videos from newly included patients were analyzed with the CNN2. Half of cases (50 %) had neoplastic lesions. This model achieved significant accuracy values for neoplastic diagnosis, with a 90.5 % sensitivity, 68.2 % specificity, and 74.0 % and 87.8 % positive and negative predictive values, respectively. The CNN2 model outperformed nonexpert #2 (area under the receiver operating characteristic curve [AUC]-CRM 0.657 vs. AUC-CNN2 0.794, P < 0.05; AUC-Mendoza 0.582 vs. AUC-CNN2 0.794, P < 0.05), nonexpert #4 (AUC-CRM 0.683 vs. AUC-CNN2 0.791, P < 0.05), and expert #4 (AUC-CRM 0.755 vs. AUC-CNN2 0.848, P < 0.05; AUC-Mendoza 0.753 vs. AUC-CNN2 0.848, P < 0.05). CONCLUSIONS: The proposed CNN model distinguished neoplastic bile duct lesions with good accuracy and outperformed two nonexpert and one expert endoscopist.


Assuntos
Inteligência Artificial , Neoplasias , Humanos , Redes Neurais de Computação , Curva ROC , Valor Preditivo dos Testes
3.
Am J Trop Med Hyg ; 83(6): 1183-6, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21118919

RESUMO

Previous reports have described obtaining mature Plasmodium vivax ookinetes in vitro using blood from infected patients using a simplified, field-based protocol. Here, we report protocols that produce improved P. vivax ookinete yields and morphological development. Optimal conditions included induction of gametogenesis using 10 mM Tris, 170 mM NaCl, 10 mM glucose, 25 mM NaHCO(3), and 100 µM xanthurenic acid for 90 minutes at pH 8.0-8.2, followed by culture in RPMI-1640, 50 mg/mL hypoxanthine, 25 mM HEPES, 29 mM NaHCO(3), 2 mM L-glutamine, and 20% fetal bovine serum at pH 8.4 for 36 hours. Ookinetes were produced in 86% (18/21) of optimized in vitro cultures; yields ranged from 6.5 × 10(4) to 2.8 × 10(6); percent gametocyte conversion ranged from 1.4% to 4.7%. This improved method is suitable for preparation of P. vivax ookinetes in quantities sufficient for biochemical, molecular, and cell biological analysis where basic laboratory facilities are in proximity to patients with vivax malaria.


Assuntos
Técnicas de Cultura de Células/métodos , Plasmodium vivax/fisiologia , Animais , Sangue/parasitologia , Meios de Cultura , Humanos , Malária Vivax , Oogênese , Reprodução/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA