Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37922163

RESUMO

The assessment of implant status and complications of Total Hip Replacement (THR) relies mainly on the clinical evaluation of the X-ray images to analyse the implant and the surrounding rigid structures. Current clinical practise depends on the manual identification of important landmarks to define the implant boundary and to analyse many features in arthroplasty X-ray images, which is time-consuming and could be prone to human error. Semantic segmentation based on the Convolutional Neural Network (CNN) has demonstrated successful results in many medical segmentation tasks. However, these networks cannot define explicit properties that lead to inaccurate segmentation, especially with the limited size of image datasets. Our work integrates clinical knowledge with CNN to segment the implant and detect important features simultaneously. This is instrumental in the diagnosis of complications of arthroplasty, particularly for loose implant and implant-closed bone fractures, where the location of the fracture in relation to the implant must be accurately determined. In this work, we define the points of interest using Gruen zones that represent the interface of the implant with the surrounding bone to build a Statistical Shape Model (SSM). We propose a multitask CNN that combines regression of pose and shape parameters constructed from the SSM and semantic segmentation of the implant. This integrated approach has improved the estimation of implant shape, from 74% to 80% dice score, making segmentation realistic and allowing automatic detection of Gruen zones. To train and evaluate our method, we generated a dataset of annotated hip arthroplasty X-ray images that will be made available.

2.
Int J Comput Assist Radiol Surg ; 17(4): 649-660, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35157227

RESUMO

PURPOSE: Object classification and localization is a key task of computer-aided diagnosis (CAD) tool. Although there have been numerous generic deep learning (DL) models developed for CAD, there is no work in the literature to evaluate their effectiveness when utilized in diagnosing fractures in proximity of joint implants. In this work, we aim to assess the performance of existing classification systems on binary and multi-class problems (fracture types) using plain radiographs. In addition, we evaluated the performance of object detection systems using the one- and two-stage DL architectures. METHODS: A data set of 1272 X-ray images of Peri-prosthetic Femur Fracture PFF was collected. The fractures were annotated with bounding boxes and classified according to the Vancouver Classification System (type A, B, C) by two clinical specialists. Four classification models such as Densenet161, Resnet50, Inception, VGG and two object detection models such as Faster RCNN and RetinaNet were evaluated, and their performance compared. Six confusion matrix-based measures were reported to evaluate fracture classification. For localization of the fracture, Average Precision and localization accuracy were reported. RESULTS: The Resnet50 showed the best performance with [Formula: see text] accuracy and [Formula: see text] F1-score in the binary classification: fracture/normal. In addition, the Resnet50 showed [Formula: see text] accuracy in multi-classification (normal, Vancouver type A, B and C). CONCLUSIONS: A large data set of PFF images and the annotations of fracture features by two independent assessments were created to implement a DL-based approach for detecting, classifying and localizing PFFs. It was shown that this approach could be a promising diagnostic tool of fractures in proximity of joint implants.


Assuntos
Aprendizado Profundo , Fraturas do Fêmur , Diagnóstico por Computador , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA