PLoS One ; 17(4): e0265609, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35404962

RESUMO

We estimate the lifetime attributable risk (LAR) of lung cancer incidence in symptomatic Coronary Artery Disease (CAD) patients receiving enhanced Coronary Computed Tomography Angiography (CCTA) and the unenhanced Computed Tomography Calcium Scoring (CTCS) examination. Retrospective analysis has been made of CCTA and CTCS data collected for 87 confirmed CAD adult patients. Patient effective dose (E) and organ doses (ODs) were calculated using CT-EXPO. Statistical correlation and the differences between E and ODs in enhanced CCTA and unenhanced CTCS were calculated using the Pearson coefficient and Wilcoxon unpaired t-test. Following BEIR VII report guidance, organ-specific LARs for the cohort were estimated using the organ-equivalent dose-to-risk conversion factor for numbers of cases per 100,000 patients exposed to low doses of 0.1 Gy. Significant statistical difference (p<0.0001) is found between E obtained for CTCS and that of CCTA. The scan length was found to be greater in CCTA (17.5 ± 2.9 cm) compared to that for CTCS (15 ± 2 cm). More elevated values of dose were noted for the esophagus (4.2 ± 2.15 mSv) and thymus (9.6 ± 2.54 mSv) for both CTCS and CCTA. CTCS organ doses were lower than that of CCTA. Per 100,000 patients, female cumulative doses are seen to give rise to greater lung cancer LARs compared to that for males, albeit with risk varying significantly, noticeably greater for females, younger patients and combined CCTA and CTCS scans. While scan parameters and tube-modulation methods clearly contribute to patient dose, mAs offers by far the greater contribution.


Assuntos
Doença da Artéria Coronariana , Neoplasias Pulmonares , Adulto , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/etiologia , Masculino , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Br J Radiol ; 95(1134): 20211197, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35195439

RESUMO

OBJECTIVE: This study aims to establish risk of breast cancer based on breast density among Saudi women and to compare cancer prediction using different breast density methods. METHODS: 1140 pseudonymised screening mammograms from Saudi females were retrospectively collected. Breast density was assessed using Breast Imaging Reporting and Data System (BI-RADS) density categories and visual analogue scale (VAS) of 285 cases and 855 controls matched on age and body mass index. In a subset of 160 cases and 480 controls density was estimated by two automated methods, Volpara Density™ and predicted VAS (pVAS). Odds ratios (ORs) between the highest and second categories in BI-RADS and Volpara density grades, and highest vs lowest quartiles in VAS, pVAS and Volpara Density™, were estimated using conditional logistic regression. RESULTS: For BI-RADS, the OR was 6.69 (95% CI 2.79-16.06) in the highest vs second category and OR = 4.78 (95% CI 3.01-7.58) in the highest vs lowest quartile for VAS. In the subset, VAS was the strongest predictor OR = 7.54 (95% CI 3.86-14.74), followed by pVAS using raw images OR = 5.38 (95% CI 2.68-10.77) and Volpara Density ™ OR = 3.55, (95% CI 1.86-6.75) for highest vs lowest quartiles. The matched concordance index for VAS was 0.70 (95% CI 0.65-0.75) demonstrating better discrimination between cases and controls than all other methods. CONCLUSION: Increased mammographic density was strongly associated with risk of breast cancer among Saudi women. Radiologists' visual assessment of breast density is superior to automated methods. However, pVAS and Volpara Density ™ also significantly predicted breast cancer risk based on breast density. ADVANCES IN KNOWLEDGE: Our study established an association between breast density and breast cancer in a Saudi population and compared the performance of automated methods. This provides a stepping-stone towards personalised screening using automated breast density methods.


Assuntos
Densidade da Mama , Neoplasias da Mama , Neoplasias da Mama/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Modelos Logísticos , Mamografia/métodos , Estudos Retrospectivos , Arábia Saudita
3.
Appl Radiat Isot ; 182: 110141, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35180526

RESUMO

The Raman intensity ratio ID/IG for: (a) graphite-rich pencil rods irradiated using x-ray doses up to 20 Gy; (b) a restricted view of the ID/IG response for the same group of media, limited to x-ray doses of no more than 6 Gy; (c1 and c2) an extended group of graphite-rich media irradiated using 60Co gamma-rays; (d) a restricted view of the ID/IG response for a restricted group of the media shown in (c), with 60Co gamma-ray doses limited to no more than 20 Gy; (e) 2B graphite-rich pencil rods irradiated using 6 MeV electrons, and: (f) irradiation of a subset of the media by thermal (0.025 eV) neutrons. The fluctuation of ID/IG with dose for carbon-rich human hair of nominal diameter 60 µm is indicated by the dashed line in (c) and (d). The values in parentheses indicate the percentage carbon content and the surface area-to-volume ratio of samples. The data are a re-organisation of that included in the studies of Abdul Sani et al. (2020, Bradley et al. (2019, 2021), Mat Nawi et al. (2021a,b), and Lam et al. (2021) such as to illustrate three prime dependencies, viz. surface to volume ratio, carbon content, and linear energy transfer, LET. (g) and (h) are combination graphs as indicated in the key to each.

4.
Materials (Basel) ; 14(12)2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34207950

RESUMO

Cobalt (Co) doped zinc oxide (ZnO) microcrystals (MCs) are prepared by using the hydrothermal method from the precursor's mixture of zinc chloride (ZnCl2), cobalt-II chloride hexahydrate (CoCl2·6H2O), and potassium hydroxide (KOH). The smooth round cylindrical morphologies of the synthesized microcrystals of Co-doped ZnO show an increase in absorption with the cobalt doping. The antibacterial activity of the as-obtained Co-doped ZnO-MCs was tested against the bacterial strains of gram-negative (Escherichia coli, Klebsiella pneumonia) and gram-positive bacteria (Staphylococcus aureus, Streptococcus pyogenes) via the agar well diffusion method. The zones of inhibition (ZOI) for Co-doped ZnO-MCs against E. coli and K. pneumoniae were found to be 17 and 19 mm, and 15 and 16 mm against S. Aureus and S. pyogenes, respectively. The prepared Co-doped ZnO-MCs were thus established as a probable antibacterial agent against gram-negative bacterial strains.

5.
Dose Response ; 19(3): 15593258211028467, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34290574

RESUMO

This work concerns study of self-absorption factor (SAF) and dose rate constants of zirconium-89 (89Zr) for the purpose of radiation protection in positron emission tomography (PET) and to compare them with those of 18F-deoxyglucose (18F-FDG). We analyzed the emitted energy spectra by 18F and 89Zr through anthropomorphic phantom and calculated the absorbed energy using Monte Carlo method. The dose rate constants for both radionuclides were estimated with 2 different fluence-to-effective dose conversion coefficients. Our estimated SAF value of 0.65 for 18F agreed with the recommendation of the American Association of Physicists in Medicine (AAPM). The SAF for 89Zr was in the range of 0.61-0.66 depending on the biodistribution. Using the fluence-to-effective dose conversion coefficients recommended jointly by the American National Standards Institute and the American Nuclear Society (ANSI/ANS), the dose rate at 1 m from the patient for 18F was 0.143 µSv·MBq-1·hr-1, which is consistent with the AAPM recommendation, while that for 89Zr was 0.154 µSv·MBq-1·hr-1. With the conversion coefficients currently recommended by the International Committee on Radiological Protection (ICRP), the dose rate estimates were lowered by 2.8% and 2.6% for 89Zr and 18F, respectively. Also, we observed that the AAPM derived dose is an overestimation near the patient, compared to our simulations, which can be explained by the biodistribution nature and the assumption of the point source. Thus, we proposed new radiation protection factors for 89Zr radionuclide.

6.
Appl Radiat Isot ; 174: 109769, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34048993

RESUMO

Present work builds upon prior investigations concerning the novel use of graphite-rich polymer pencil-lead for passive radiation dosimetry. Working with photon-mediated interactions at levels of dose familiar in radiotherapy, exploratory investigations have now been made using graphite produced commercially in the form of 50 µm thick sheets. Focusing on the relationship between absorbed radiation energy and induced material changes, investigations have been made of thermo- and photoluminescence dose dependence, also of alterations in Raman spectroscopic features. Photoluminescence studies have focused on the degree of structural order of the samples when exposed to incident MeV energy gamma-radiation, supported by crystallite size evaluations. The results are consistent and evident of structural alterations, radiation-driven thermal annealing also being observed. The results, supportive of previous TL, Raman and photoluminescence studies, are readily understood to arise from irradiation changes occurring at the microscopic level. Notwithstanding the non-linearities observed in the conduct of Raman and photoluminescence studies there is clear potential for applications in use of the defect-dependent methods herein, providing sensitive detection of radiation damage in graphite and from it dose determination. Most specifically, the readily available thin graphite sheets can provide the basis of a low-cost yet highly effective system for studies of radiation-driven changes in carbon (and/or carbon based composites), also as a dosimetric probe of skin dose, its atomic number closely matching with the effective atomic number of soft tissues.

7.
Nanomaterials (Basel) ; 11(2)2021 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-33578945

RESUMO

Copper oxide and Zinc (Zn)-doped Copper oxide nanostructures (CuO-NSs) are successfully synthesized by using a hydrothermal technique. The as-obtained pure and Zn-doped CuO-NSs were tested to study the effect of doping in CuO on structural, optical, and antibacterial properties. The band gap of the nanostructures is calculated by using the Tauc plot. Our results have shown that the band gap of CuO reduces with the addition of Zinc. Optimization of processing conditions and concentration of precursors leads to the formation of pine needles and sea urchin-like nanostructures. The antibacterial properties of obtained Zn-doped CuO-NSs are observed against Gram-negative (Pseudomonas aeruginosa, Klebsiella pneumonia, Escherichia coli) and Gram-positive (Staphylococcus aureus) bacteria via the agar well diffusion method. Zn doped s are found to have more effective bacterial resistance than pure CuO. The improved antibacterial activity is attributed to the reactive oxygen species (ROS) generation.

8.
Curr Med Imaging ; 17(2): 296-305, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33045969

RESUMO

INTRODUCTION: The purpose of the present work was to evaluate the imaging characteristics of 89Zr-PET in comparison with those obtained using fluorine-18 Fluorodeoxyglucose (18FFDG) PET (a gold standard tracer in PET imaging) using a small-animal NanoScan PET/CT scanner. METHODS: The system's spatial resolution, sensitivity, uniformity, and image quality were measured on a Nano Scan small-animal PET/CT scanner according to the NEMA NU4-2008 protocols. For reconstruction images, we used 2D and 3D reconstruction algorithms. The reconstruction methods included filter back projection (FBP), the ordered subsets expectation maximization (OSEM) algorithm, and the 3D Tera-Tomo algorithm, which are developed for the NanoScan small-animal PET/CT scanner. RESULTS: The results obtained showed a significant difference in the spatial resolution for 89Zr as compared to 22Na and 18F when using a 2D reconstruction algorithm. The spatial resolution values were much enhanced by using the 3D Tera-Tomo reconstruction for each isotope, the Full width at half maximum (FWHM) values was less than 1 for all isotopes at the center of the field of view (FOV). This difference in spatial resolution is dependent on the positron range, energy, and the reconstruction method. CONCLUSION: The long half-life of 89Zr makes it an ideal positron emitter for performing immuno- PET, which is matched with the biological half-life of intact mAbs.89Zr can also give several advantages over other long half-life positron emitters in relation to the overall imaging performance because of its relatively short positron range and simpler decay scheme. The values of 89Zr sensitivity that were obtained in the present study were less than those of previous studies.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Animais , Fluordesoxiglucose F18 , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons
9.
Dose Response ; 17(2): 1559325819855532, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31236089

RESUMO

The purpose of this study is to investigate the potentiality of Gafchromic external beam therapy 3 (EBT3) film to measure low dosage of solar ultraviolet (SUV; 0-10 600 mJ/cm2) and x-ray (0-750 mGy) radiation. In this experiment, 2 groups of EBT3 films were prepared with size 2 cm × 1 cm. The first group of films was exposed by incremental SUV dose in the middle of the day. The other group was irradiated by x-ray at 100 kVp, 100 mA, and 2 S of tube voltage, tube current, and exposure time, respectively. The measured SUV consists of 90% ultraviolet A (UVA) and 10% ultraviolet B. The film discoloration was represented by visible absorbance spectroscopy technique using Jaz spectrometer from Ocean Optics Inc. Simple linear regression produced high accuracy with coefficients of determination, r 2 of 0.9804 and root mean square error (RMSE) of 434.88 mJ/cm2 for the measurement of SUV dose. On the other hand, r 2 of 0.98 and RMSE of 31 mGy was produced for the measurement of x-ray dose. The application of multiple linear regression enhanced the measurement accuracy with R 2 of 99% and 99.7% and RMSE of 327.06 mJ/cm2 and 15.045 mGy for SUV and x-ray dose, respectively. The spectral analysis shows a promising measurement at selected wavelengths for SUV and x-ray dose.

10.
Health Phys ; 116(6): 789-798, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30889102

RESUMO

The presence of natural radionuclides in the food chain point to a need to assess concentration levels and concomitant radiological risk. Highly popular and forming a staple part of the diet in North Africa, the Arabian Peninsula, and West Asia, palm dates growing naturally there have even greater marketability than simple satisfaction of domestic demand, the palm dates representing a valuable export item. Accurate knowledge of the levels of natural radioactivity in the fruit is thus of importance. In this study, using high-purity germanium gamma-ray spectrometry, quantification has been made of natural radionuclide concentrations in imported dates originating from Iran, Saudi Arabia, and Tunisia. Sample analyses reveal respective mean activity concentrations of 1.4 ± 0.3, 0.8 ± 0.4, and 186 ± 9 Bq kg dry weight for Ra, Ra, and K. For each nuclide, the mean concentration varies little between the dates of the three represented regions. The estimated committed effective dose resulting from the consumption of date fruits for a typical adult was found to be 29.9 µSv y, well below the global internal dose of 290 µSv y assessed by the United Nations Scientific Committee on the Effects of Atomic Radiation to be due to food and water intake. Similarly, the excess lifetime cancer risk due to naturally occurring radioactive material exposure via date fruit consumption is seen to be below the International Commission on Radiological Protection cancer risk factor of 2.5 × 10 based on the additional annual dose limit of 1 mSv for a member of the general public. The results show no significant uptake in the analyzed date fruits.


Assuntos
Dieta , Contaminação Radioativa de Alimentos/análise , Frutas/química , Phoeniceae/química , Radioisótopos de Potássio/análise , Rádio (Elemento)/análise , Humanos , Monitoramento de Radiação
11.
Radiat Prot Dosimetry ; 183(4): 496-501, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30260437

RESUMO

This study sought to assess patient and operator eye lens doses in diagnostic coronary angiography (DCA) and percutaneous coronary interventions (PCI) in a University hospital in Oman. Kerma area product (PkA), cumulative air kerma (CAK) and fluoroscopic time (FT) were retrospectively recorded from the DICOM header for 264 patients. The median (interquartile range) of FT, PKA and CAK were: 5.3 min (2.6-10.5), 60.9 Gy cm2 (41.3-91.4) and 0.86 Gy (0.61-1.29), respectively, for DCA procedures, and they were 20.2 min (13.3-30.1), 174.0 Gy cm2 (113.7-253.3) and 2.6 Gy (1.8-3.9), respectively, for PCI procedures. The results revealed wide variability in patient doses among individual patients. Monitoring and recording patient dose data can be valuable for quality assurance and patient safety purposes. Feedback to the operator may help optimize radiation doses to patients and prompt further action, as needed.


Assuntos
Angiografia Coronária/métodos , Fluoroscopia/métodos , Intervenção Coronária Percutânea/métodos , Exposição à Radiação/análise , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Fatores de Risco
12.
Appl Radiat Isot ; 141: 176-181, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29673719

RESUMO

In previous work we investigated the real-time radioluminescence (RL) yield of Ge-doped silica fibres and Al2O3 nanodot media, sensing electron- and x-ray energies and intensities at values familiarly obtained in external beam radiotherapy. The observation of an appreciable low-dose sensitivity has given rise to the realisation that there is strong potential for use of RL dosimetry in diagnostic radiology. Herein use has been made of P-doped silica optical fibre, 2 mm diameter, also including a 271 µm cylindrical doped core. With developing needs for versatile x-ray imaging dosimetry, preliminary investigations have been made covering the range of diagnostic x-ray tube potentials 30 kVp to 120 kVp, demonstrating linearity of RL with kVp as well as in terms of the current-time (mAs) product. RL yields also accord with the inverse-square law. Given typical radiographic-examination exposure durations from tens- to a few hundred milliseconds, particular value is found in the ability to record the influence of x-ray generator performance on the growth and decay of beam intensity, from initiation to termination.


Assuntos
Exposição Ocupacional/análise , Exposição à Radiação/análise , Dosimetria Termoluminescente/métodos , Humanos , Exposição Ocupacional/efeitos adversos , Fibras Ópticas , Exposição à Radiação/efeitos adversos , Radiografia/efeitos adversos , Dióxido de Silício , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/estatística & dados numéricos
13.
Nucl Med Commun ; 37(12): 1238-1245, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27749774

RESUMO

PURPOSE: Interest in PET imaging using zirconium-89 (Zr) (t1/2=78.41 h)-labeled tracers for the tracking and quantification of monoclonal antibodies (mAbs) is growing, mainly because of its well-matched physical half-life with the biological half-life of intact mAbs. This study aims to evaluate the imaging characteristics of Zr-PET in comparison with those obtained using fluorine-18 fluorodeoxyglucose (F-FDG) PET (gold standard tracer in PET imaging) using a Time-Of-Flight (TOF) PET/computed tomography (CT) scanner. MATERIALS AND METHODS: The system's spatial resolution, sensitivity, scatter fraction (SF), image uniformity, and image quality were measured on a Gemini TOF PET/CT scanner according to the NEMA NU2-2001 protocols. The NEMA 2001 kit was used to carry out these measurements. Timing and energy resolutions were measured using Na and F-FDG point sources only. RESULTS: Spatial resolution in transverse and axial planes measured at 10 mm off access were 4.7 and 4.6 mm for Zr and F-FDG, respectively. At 100 mm, radial, tangential, and axial spatial resolution values were 5.2, 5.1, and 5.2 mm for Zr and 5.1, 4.9, and 5.2 mm for F-FDG, respectively. Sensitivity measured at the center of the field of view was 14.6 and 4.16 cps/kBq for Zr and F-FDG, respectively. SF was 32.6% for Zr in comparison with 31.8% for F-FDG. Image contrast for Zr-PET images was 36.9 and 29.7% for F-FDG for the smallest (10 mm)-sized sphere, and it was 70.6 and 72.8% for Zr and F-FDG, respectively, for the largest (37 mm)-sized sphere. Background variation was 10.3% for Zr and 6.8% for F-FDG for the smallest-sized sphere and 3.4 and 3.8% for Zr and F-FDG, respectively, for the largest-sized sphere. CONCLUSION: In this study, we measured imaging characteristics of Zr on a Gemini TOF PET/CT scanner. Our results show that Zr has lower spatial resolution and noise-equivalent count rate with increased SF and background variation; however, it offered superior sensitivity and improved image contrast in comparison with F-FDG. Zr is an ideal radiotracer for immuno-PET imaging because of its physical half-life, which is well matched with mAbs, in addition to its affinity to be trapped inside the target cell after internalization of the mAbs.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos , Zircônio , Anticorpos Monoclonais/farmacocinética , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Meia-Vida , Humanos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Compostos Radiofarmacêuticos , Espalhamento de Radiação , Sensibilidade e Especificidade
14.
Appl Radiat Isot ; 117: 106-110, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26777569

RESUMO

Graphite ion chambers and semiconductor diode detectors have been used to make measurements in phantoms but these active devices represent a clear disadvantage when considered for in vivo dosimetry. In such circumstance, dosimeters with atomic number similar to human tissue are needed. Carbon nanotubes have properties that potentially meet the demand, requiring low voltage in active devices and an atomic number similar to adipose tissue. In this study, single-wall carbon nanotubes (SWCNTs) buckypaper has been used to measure the beta particle dose deposited from a strontium-90 source, the medium displaying thermoluminescence at potentially useful sensitivity. As an example, the samples show a clear response for a dose of 2Gy. This finding suggests that carbon nanotubes can be used as a passive dosimeter specifically for the high levels of radiation exposures used in radiation therapy. Furthermore, the finding points towards further potential applications such as for space radiation measurements, not least because the medium satisfies a demand for light but strong materials of minimal capacitance.


Assuntos
Materiais Biomiméticos/química , Materiais Biomiméticos/efeitos da radiação , Nanotubos de Carbono/química , Nanotubos de Carbono/efeitos da radiação , Papel , Dosimetria Termoluminescente/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Física Médica/instrumentação , Física Médica/métodos , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
15.
World J Radiol ; 7(5): 89-99, 2015 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-26029351

RESUMO

Medical ultrasound imaging with Doppler plays an essential role in the diagnosis of vascular disease. This study intended to review the clinical use of "to-and-fro" waveform at duplex Doppler ultrasonography (DDU) in the diagnosis of pseudoaneurysms in the arterial vessels of upper and lower extremities, abdominal aorta, carotid and vertebral arteries as well as to review our personal experiences of "to-and-fro" waveform at DDU also. After receiving institutional review board approval, an inclusive literature review was carried out in order to review the scientific foundation of "to-and-fro" waveform at DDU and its clinical use in the diagnosis of pseudoaneurysms in various arterial vessels. Articles published in the English language between 2000 and 2013 were evaluated in this review study. Pseudoaneurysms in arterial vessels of the upper and lower extremities, abdominal aorta, carotid and vertebral arteries characterized by an extraluminal pattern of blood flow, which shows variable echogenicity, interval complexity, and "to-and-fro" flow pattern on color Doppler ultrasonography. In these arterial vessels, Duplex ultrasonography can demonstrate the degree of clotting, pseudoaneurysm communication, the blood flow patterns and velocities. Spectral Doppler applied to pseudoaneurysms lumen revealed systolic and diastolic turbulent blood flow with traditional "to-and-fro" waveform in the communicating channel. Accurate diagnosis of pseudoaneurysm by spectral Doppler is based on the documentation of the "to-and-fro" waveform. The size of pseudoaneurysm determines the appropriate treatment approach as surgical or conservative.

16.
Pol J Radiol ; 80: 131-41, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25806099

RESUMO

BACKGROUND: High-intensity focused ultrasound (HIFU) applies high-intensity focused ultrasound energy to locally heat and destroy diseased or damaged tissue through ablation. This study intended to review HIFU to explain the fundamentals of HIFU, evaluate the evidence concerning the role of HIFU in the treatment of prostate cancer (PC), review the technologies used to perform HIFU and the published clinical literature regarding the procedure as a primary treatment for PC. MATERIAL/METHODS: Studies addressing HIFU in localized PC were identified in a search of internet scientific databases. The analysis of outcomes was limited to journal articles written in English and published between 2000 and 2013. RESULTS: HIFU is a non-invasive approach that uses a precisely delivered ultrasound energy to achieve tumor cell necrosis without radiation or surgical excision. In current urological oncology, HIFU is used clinically in the treatment of PC. Clinical research on HIFU therapy for localized PC began in the 1990s, and the majority of PC patients were treated with the Ablatherm device. CONCLUSIONS: HIFU treatment for localized PC can be considered as an alternative minimally invasive therapeutic modality for patients who are not candidates for radical prostatectomy. Patients with lower pre-HIFU PSA level and favourable pathologic Gleason score seem to present better oncologic outcomes. Future advances in technology and safety will undoubtedly expand the HIFU role in this indication as more of patient series are published, with a longer follow-up period.

17.
Pol J Radiol ; 79: 384-90, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25371765

RESUMO

BACKGROUND: High-intensity focused ultrasound (HIFU) is a highly precise medical procedure used locally to heat and destroy diseased tissue through ablation. This study intended to review HIFU in uterine fibroid therapy, to evaluate the role of HIFU in the therapy of leiomyomas as well as to review the actual clinical activities in this field including efficacy and safety measures beside the published clinical literature. MATERIAL/METHODS: An inclusive literature review was carried out in order to review the scientific foundation, and how it resulted in the development of extracorporeal distinct devices. Studies addressing HIFU in leiomyomas were identified from a search of the Internet scientific databases. The analysis of literature was limited to journal articles written in English and published between 2000 and 2013. RESULTS: In current gynecologic oncology, HIFU is used clinically in the treatment of leiomyomas. Clinical research on HIFU therapy for leiomyomas began in the 1990s, and the majority of patients with leiomyomas were treated predominantly with HIFUNIT 9000 and prototype single focus ultrasound devices. HIFU is a non-invasive and highly effective standard treatment with a large indication range for all sizes of leiomyomas, associated with high efficacy, low operative morbidity and no systemic side effects. CONCLUSIONS: Uterine fibroid treatment using HIFU was effective and safe in treating symptomatic uterine fibroids. Few studies are available in the literature regarding uterine artery embolization (UAE). HIFU provides an excellent option to treat uterine fibroids.

18.
Pol J Radiol ; 79: 344-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25289112

RESUMO

BACKGROUND: The use of pediatric CT that had recently emerged as a valuable imaging tool has increased rapidly with an annual growth estimated at about 10% per year. Worldwide, there is a remarkable increase in the number of CT examinations performed. The purposes of this study are to: (i) to measure the radiation dose and estimate the effective doses to pediatric patients during CT for chest, abdomen and brain. MATERIAL/METHODS: A total of 182 patients were investigated. CT scanners that participated in this study are helical CT scanners (64 slices, 16 slices and dual slices). Organ and surface dose to specific radiosensitive organs were estimated by using software from National Radiological Protection Board (NRPB). RESULTS: For all patients, the age was ranged between 1.12 month-10.0 years while the weight was ranged between 5.0 kg to 29.0 kg. The DLP was 320.58 mGy·cm, 79.93 mGy·cm, 66.63 mGy·cm for brain, abdomen and chest respectively. The effective dose was, 2.05, 1.8, 1.08 mSv for brain, abdomen and chest respectively. CONCLUSIONS: The patient dose is independent of CT modality and depends on operator experience and CT protocol. The study has shown a great need for referring criteria, continuous training of staff in radiation protection concepts. Further studies are required in order to establish a reference level in Sudan.

19.
J Med Ultrason (2001) ; 41(3): 351-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27277910

RESUMO

PURPOSE: This study evaluates using ultrasound the changes that occur in wall thickness, blood flow velocity, and Doppler indices of the common carotid arteries (CCAs) in healthy Saudi adult males who are current smokers. METHODS: A prospective study was performed between May 2011 and May 2013 with a group consisting of nonsmokers (n = 180; 36 %) and current smokers (n = 320; 64 %) with a mean age of 25 ± 2.6 years. In all cases, the CCA ultrasound scanning protocol met the standards established by the American Institute of Ultrasound in Medicine (AIUM) to measure intima media thickness (IMT), peak systolic velocity (PSV), and end diastolic velocity (EDV). The Statistical Package for the Social Sciences (SPSS) was used to analyze the results. RESULTS: Significant linear and positive correlations were noted between the level of daily consumption of cigarettes smoked and carotid mean IMT, PSV, and Doppler indices, while a linear and negative correlation was present between cigarette smoking and mean EDV. These findings were significant when compared with the results for nonsmokers. CONCLUSIONS: Cigarette smoking is associated with CCA morphological changes caused by significant impairment of arterial endothelial function, and an increase in daily cigarette consumption significantly leads to a decrease in the blood flow velocity of CCAs.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiopatologia , Fumar/fisiopatologia , Ultrassonografia Doppler , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Espessura Intima-Media Carotídea , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Arábia Saudita , Índice de Gravidade de Doença , Adulto Jovem
20.
Gastroenterol Res Pract ; 2013: 587574, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23589714

RESUMO

This study intended to optimize the radiation doses for gastroenterologists and patients during therapeutic endoscopic retrograde cholangiopancreatography (ERCP) and to compare the doses based on available data obtained by other researchers. A total of 153 patients were studied in two Gastroenterology Departments, (group A, 111; group B, 42). Thermoluminescent dosimeters (TLD) were used to measure the staff and patients entrance surface air kerma (ESAK) at different body sites. The mean ESAK and effective doses per procedure were estimated to be 68.75 mGy and 2.74 mSv, respectively. Staff was exposed to a heterogonous doses. The third examiner (trainee) was exposed to a high dose compared with other examiners because no shield was located to protect him from stray radiation. Patients and examiners doses were lower compared to the lowest values found in previous studies taking into consideration the heterogeneity of patients and equipment. Staff doses during ERCP are within the safety limit in the light of the current practice.

SELEÇÃO DE REFERÊNCIAS