Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ter Arkh ; 96(7): 675-682, 2024 Jul 30.
Artigo em Russo | MEDLINE | ID: mdl-39106510

RESUMO

AIM: To evaluate the efficacy and safety of the advanced technique for positioning the endocardial electrodes of a cardiac contractility modulation (CCM) device. MATERIALS AND METHODS: The CCM system was implanted in 100 patients, of which 60 CCM electrodes were positioned in the most optimal zones of myocardial perfusion, in particular, in the zone of the minor focal-scar/fibrotic lesion (the Summed Rest Score of 0 to 1-2, the intensity of the radiopharmaceutical at least 30%), and in 40 patients according to the standard procedure. Before the implantation of the CCM system, 60 patients underwent tomography (S-SPECT) of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest to determine the most optimal electrode positioning zones and 100 patients underwent transthoracic echocardiography at baseline and after 12 months to assess the effectiveness of surgical treatment. RESULTS: Improved ventricular electrode positioning technique is associated with the best reverse remodeling of the left ventricular myocardium, especially in patients with ischemic chronic heart failure, with less radiation exposure to the surgeon and the patient, and without electrode-related complications. CONCLUSION: At the preoperative stage, it is recommended to perform a synchronized single-photon emission computed tomography of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest before implantation of the CCM device to assess the presence of scar zones/myocardial fibrosis in the anterior and inferior septal regions of the interventricular septum of the left ventricle, followed by implantation of ventricular electrodes in the zone of the minor scar/fibrous lesion, which will allow to achieve optimal stimulation parameters, increase the effectiveness of CCM therapy, reduce the radiation exposure on medical personnel and the patient during surgery.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Idoso , Resultado do Tratamento , Eletrodos Implantados , Volume Sistólico/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Ecocardiografia/métodos , Contração Miocárdica/fisiologia
2.
Kardiologiia ; 63(3): 36-45, 2023 Mar 31.
Artigo em Russo | MEDLINE | ID: mdl-37061859

RESUMO

Aim      To evaluate a possibility of using radiofrequency catheter ablation guided by intracardiac echocardiography (ICE), its efficacy and safety for treatment of ventricular tachycardia (VT) of various etiology.Material and methods  Catheter intervention was performed for 20 enrolled patients with symptomatic VT. Ablation procedures were guided by a 3D electroanatomical mapping system and ICE.Results Mean duration of the procedure was 201.2±62.5 min. The procedure was successful (non-inducibility of VT) in 100% of cases. None of the patients had postoperative complications.Conclusion      Ablation of VT arrhythmogenic substrate guided by 3D electroanatomical navigational mapping and ICE without X-ray is feasible and safe.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pericárdio , Resultado do Tratamento
3.
Ter Arkh ; 94(9): 1078-1084, 2022 Oct 24.
Artigo em Russo | MEDLINE | ID: mdl-36286759

RESUMO

AIM: To evaluate the efficacy, safety and effect on the prognosis of cardiac contractility modulation (CCM) in patients with chronic heart failure (CHF) with reduced left ventricular ejection fraction and atrial fibrillation compared with the group of only optimal drug therapy (ODT) of the 12-month follow-up. MATERIALS AND METHODS: Patients (n=200) were sequentially included in two groups: group 1 patients with CHF who are on ODT in combination with implanted CCM devices (n=100), group 2 comparison patients with CHF who receive only ODT (n=100). Initially and after 12 months, 12-channel electrocardiography (ECG), transthoracic echocardiography, daily ECG-monitoring, determination of the level of NT-proBNP, a six-minute walk test and an assessment of the quality of life according to the Minnesota Questionnaire were performed. RESULTS: In the CCM therapy group, a significant clinical improvement was revealed, which was expressed in the form of a decrease in functional class CHF by NYHA (New York Heart Association), an increase in the distance of a six-minute walk test and an improvement in the quality of life according to Minnesota Questionnaire, as well as an improvement in left ventricle contractile function compared to the ODT group. The absence of a proarrhythmogenic effect of the CCM was shown. There was a significant decrease in the frequency of the readmission due to CHF and the probability of achieving the combined endpoint in the CCM therapy group compared with only ODT. CONCLUSION: The use of CCM in patients with CHF and atrial fibrillation is an effective and safe method of therapy that leads to the development of reverse remodeling of the myocardium, improves the clinical status of patients and reduces the frequency of readmission due to decompensation of CHF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Volume Sistólico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Função Ventricular Esquerda , Qualidade de Vida , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Doença Crônica , Resultado do Tratamento
4.
Ter Arkh ; 92(9): 8-14, 2020 Oct 14.
Artigo em Russo | MEDLINE | ID: mdl-33346425

RESUMO

AIM: to evaluate the effectiveness of cardiac contractility modulation (MSS) in patients with chronic heart failure (CHF) and atrial fibrillation (AF). MATERIALS AND METHODS: The following studies were performed in 40 patients with CHF and AF before implantation of the MSS device and after 2 and 6 months of follow-up: 12-channel ECG, transthoracic EchoCG, 6-minute walk test, determination of the level of Pro-natriuretic N-terminal peptide (NT-proBNP), daily ECG monitoring, and a questionnaire based on the Minnesota quality of life questionnaire for patients with CHF (MHFLQ). All patients received long-term optimal drug therapy for CHF before surgery. RESULTS: The results obtained indicate a statistically significant positive effect of the use of MSS in patients with CHF and AF on LV FV, the functional class of CHF, and levels of NT-proBNP regardless of the etiology of CHF. CONCLUSION: The use of MSS may be promising for the treatment of heart failure in patients with CHF and AF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Fibrilação Atrial/tratamento farmacológico , Doença Crônica , Eletrocardiografia , Humanos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Qualidade de Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA