Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Oral Implantol (Berl) ; 17(1): 45-57, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501398

RESUMO

PURPOSE: To systematically screen and summarise the available literature on when and how often it is advisable to perform supportive peri-implant care on implant-supported full-arch dental prostheses to maintain peri-implant health. MATERIALS AND METHODS: The authors employed the Preferred Reporting Items for Systematic reviews and Meta-Analyses statement and the Population, Intervention, Comparison and Outcomes tool. A literature search was conducted on PubMed for randomised controlled trials, controlled clinical trials and cohort studies, reporting results on supportive peri-implant care for full-arch dental prostheses with a follow-up period of at least 1 year. The studies were selected in a blind process with an agreement rate of 100%. For all the included studies, quality assessment was performed according to the Cochrane Handbook for Systematic Reviews of Interventions. RESULTS: The application of the search terms on PubMed led to the selection of 915 results. Only 11 studies were included in the review. Eight of these reported the frequency of supportive peri-implant care, and three detailed the procedures adopted. The number of patients included ranged from 15 to 85, with a mean age from 60.4 to 68.4 years. None of the included studies were judged to be at low risk of bias. CONCLUSIONS: Removal of implant-supported prostheses is a crucial aspect in the long-term care of patients rehabilitated with full-arch restorations. Although no specific indications can be drawn with respect to the frequency at which supportive peri-implant care should be delivered and the regime used to do so, practitioners should consider performing professional oral hygiene measures every 6 months and removing prostheses at least once per year. All interventions should be tailored to the patient's risk profile and characteristics.


Assuntos
Implantes Dentários , Humanos , Higiene Bucal
2.
Minerva Dent Oral Sci ; 72(5): 230-238, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37194244

RESUMO

BACKGROUND: The aim of the present observational study was to investigate the application of transmucosal tissue-level implants in immediate loading full-arch rehabilitation with different variables associated. METHODS: Patients needing a full-arch implant rehabilitation were recruited and rehabilitated with four transmucosal tissue level implants. Data related to implants' diameters and lengths, jaw distributions, and presence of angulated abutments were collected. The following outcomes were evaluated: survival rate, marginal bone loss (MBL), Plaque Index (PI), bleeding on probing (BoP), probing depth (PD). Descriptive statistical analysis was reported and univariate linear regression models were built to assess a significant correlation between MBL and the different implant related factors. RESULTS: Twenty patients were rehabilitated for a total implant number of 80; 11 rehabilitations were performed on the maxilla, while 9 were performed on the mandible; 48 implants presented a 3.8 mm diameter and 32 implants presented a 4.25 mm diameter. Implants length varied between 10 to 15 mm; 40 tilted implants were connected to angulated abutment, while 40 straight implants were connected directly to the prostheses (no abutments). At the one year follow-up visit no implants failed resulting in an implant survival rate of 100%. The overall MBL was 1.19±0.30 mm. No statistically significant difference (P>0.05) was highlighted among any of the subgroups analyzed. CONCLUSIONS: Despite different variables associated, tissue level implants seem to represent a valid option when applied in immediate loading full-arch rehabilitation. Further research and longer observational periods are encouraged to confirm the result.

3.
Int J Mol Sci ; 23(24)2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36555385

RESUMO

Dielectrophoresis has recently been used for developing high performance elastomer-based structured piezoelectric composites. However, no study has yet focused on the development of aligned thermoplastic-based piezocomposites. In this work, highly anisotropic thermoplastic composites, with high piezoelectric sensitivity, are created. Molten-state dielectrophoresis is introduced as an effective manufacturing pathway for the obtaining of an aligned filler structure within a thermoplastic matrix. For this study, Poly(Ethylene-co Vinyl Acetate) (EVA), revealed as a biocompatible polymeric matrix, was combined with barium titanate (BaTiO3) filler, well-known as a lead-free piezoelectric material. The phase inversion method was used to obtain an optimal dispersion of the BaTiO3 within the EVA thermoplastic matrix. The effect of the processing parameters, such as the poling electric field and the filler content, were analyzed via dielectric spectroscopy, piezoelectric characterization, and scanning electron microscopy (SEM). The thermal behavior of the matrix was investigated by thermogravimetric analysis (TGA) and differential scanning calorimetry analysis (DSC). Thermoplastic-based structured composites have numerous appealing advantages, such as recyclability, enhanced piezoelectric activity, encapsulation properties, low manufacturing time, and being light weight, which make the developed composites of great novelty, paving the way for new applications in the medical field, such as integrated sensors adaptable to 3D printing technology.


Assuntos
Compostos de Bário , Excipientes , Anisotropia , Bário
4.
Biomedicines ; 10(8)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-36009382

RESUMO

This study focused on a coagulation assessment based on the novel technique of blood-impedance-magnitude measurement. With the impedance characterization of recalcified human blood, it was possible to identify two significative biomarkers (i.e., measurable indicators) related to fibrin formation (1st marker) and clot retraction (2nd marker). The confocal microscopy of clotting blood provided a complete visual analysis of all the events occurring during coagulation, validating the significance of the impedance biomarkers. By analyzing the impedance phase angle (Φ) of blood during coagulation, as well as those of the clot and serum expelled after retraction, it was possible to further clarify the origin of the 2nd marker. Finally, an impedance-magnitude analysis and a rotational thromboelastometry test (ROTEM®) were simultaneously performed on blood sampled from the same donor; the results pointed out that the 1st marker was related to clotting time. The developed technique gives rise to a comprehensive and evolutive insight into coagulation, making it possible to progressively follow the whole process in real time. Moreover, this approach allows coagulation to be tested on any materials' surface, laying the ground for new studies related to contact coagulation, meaning, thrombosis occurring on artificial implants. In a near future, impedance spectroscopy could be employed in the material characterization of cardiovascular prostheses whose properties could be monitored in situ and/or online using effective biomarkers.

5.
Dent J (Basel) ; 10(7)2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35877390

RESUMO

Recently, tissue-level implants with a convergent collar have been introduced. While different studies have investigated the outcomes of this implant design in the rehabilitation of single teeth, its use in full-arch rehabilitation has yet to be investigated. The present case report describes the clinical outcomes of a full-arch immediate loading rehabilitation using tissue-level implants, with and without using implant-abutment units, with 2 years of follow-up. A female patient with mandibular terminal dentition and a high level of bone resorption (distal areas with a few millimeters of residual bone in the vertical dimension and both distal and anterior areas with narrow crestal bone in the horizontal dimension) was seen at the C.I.R Dental School, Turin, Italy. The patient was seeking to be rehabilitated with fixed prosthodontics, and she was found eligible for an immediate loading implant full-arch rehabilitation. Four implants were inserted in the same appointment. The two anterior implants were inserted straight and connected directly to the prosthesis (no abutments); the two distal implants were tilted in order to avoid the alveolar nerve and connected to two 30° angulated abutments. Two years post-implant placement, all of the implants were successfully integrated, resulting in an implant survival rate of 100%. The peri-implant soft tissues were stable at all the implant sites. No differences were highlighted between those implants with and without abutments. Within the limitations of the present clinical report, implant full-arch rehabilitations with tissue-level implants both with and without implant-abutment units showed optimal outcomes after two years of follow-up. Further research is encouraged to confirm whether this implant design may be a valid alternative to traditional implants in this type of rehabilitation, with or without implant-abutment units.

6.
Clin Implant Dent Relat Res ; 24(5): 602-610, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35700161

RESUMO

OBJECTIVE: To compare the clinical outcomes of extra-short implants (≤6.5 mm) inserted with one-stage versus two-stage technique in adjacent sites of the upper or lower jaw. MATERIALS AND METHODS: In this split-mouth multicenter study, implants were randomly divided into two groups according to the healing phase: two-stage and one-stage technique. Primary outcome measures were implant survival, implant success, and prosthodontic complications. Secondary outcome measurements were: implant stability quotient (ISQ) collected at surgery time (T0), and after 3 (T3) and 12 (T12) months, marginal bone level (MBL) evaluated at T0, T3, T6, and T12, marginal bone loss evaluated at T6 and T12, plaque index (PI), probing depth (PD), bleeding on probing (BoP) evaluated at T3, T6, and T12. Significances of differences between groups were tested by linear mixed model with random intercept. RESULTS: Nineteen patients (8 males and 11 females) were included. A total of 38 implants were inserted. At T12 implant cumulative survival and implant success rate were 100% in both groups. No statistically significant differences were recorded for any of the analyzed parameters between the two groups at any time point. ISQ values were similar at T0 (two-stage: mean 67.53 ± SD 19.47; one-stage: mean 66.53 ± 19.07 p = 0.8738) and increased in both groups at the 12-month follow-up appointment (two-stage: 81.1 ± 7.04; one-stage: 81.39 ± 0.9266). MBL values were similar in the two groups at any time point. At T12 marginal bone loss was 0.46 ± 0.41 (two-stage) and 0.45 ± 0.38 (one-stage) mm (p = 0.9417), while mean PD was 2.7 ± 0.85 (two-stage) and 2.69 ± 0.89 (one-stage) mm. CONCLUSIONS: Within the limits of the present short-term report, extra-short implants demonstrated optimal clinical outcomes using the one-stage technique, without statistically significant differences compared with the traditional two-stage approach.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/etiologia , Índice de Placa Dentária , Feminino , Seguimentos , Humanos , Masculino , Mandíbula/cirurgia , Boca , Resultado do Tratamento
7.
Materials (Basel) ; 16(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36614586

RESUMO

Background: The aim of the present multi-center split-mouth randomized control trial was to investigate the effect on peri-implant tissue of abutment with chromium nitride/ niobium nitride (CrN/NbN) coatings (superlattice) compared to traditional machined surface. Methods: Two adjacent posterior implants were inserted in 20 patients. A machined abutment was randomly screwed on either the mesial or distal implant, while a superlattice abutment was screwed on the other one. Implant survival rate, peri-implant probing depth (PPD), plaque index (PI), and bleeding index (BI) were collected 6 months after surgery, while marginal bone loss (MBL) was evaluated at T0 and T6.; Results: Implant survival rate was 97.7%. A total MBL of 0.77 ± 0.50 mm was recorded for superlattice abutments, while a mean MBL of 0.79 ± 0.40 mm was recorded for the abutment with machined surface. A mean PPD of 1.3 ± 0.23 mm was recorded for the superlattice Group, and a mean PPD of 1.31 ± 0.3 was recorded for the machined surface Group. PI was of 0.55 ± 0.51 for superlattice Group and 0.57 ± 0.50 for machined Group, while BI was of 0.47 ± 0.49 for superlattice Group and of 0.46 ± 0.40 for the machined one. No statistically significant difference was highlighted between the two Groups (p > 0.05). Conclusions: After a 6-month observational period, no statistically significant differences were highlighted between superlattice abutment and traditional machined abutment. Further in vitro studies as well as clinical research with longer follow-ups are required to better investigate the surface properties of the novel abutments' superlattice coating and its effect on the oral tissues.

8.
Materials (Basel) ; 14(15)2021 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-34361265

RESUMO

Piezoelectric materials have been used for decades in the field of sensors as transducers and energy harvesters. Among these, piezoelectric composites are emerging being extremely advantageous in terms of production, costs, and versatility. However, the piezoelectric performances of a composite with randomly dispersed filler are not comparable with bulk ferroelectric ceramics and electroactive polymers. In order to achieve highly performing and low-cost materials, this work aims to develop flexible composites made of Lead zirconate titanate (PZT) filler in Polydimethylsiloxane (PDMS) matrix, with a specific internal structure called quasi-1-3 connectivity. Such a structure, comprising particles arranged in columns along a preferred direction, is performed through dielectrophoresis by applying an alternating electric field on the composite before and during the polymerization. The developed flexible material could be introduced into complex structures in various application fields, as sensors for structural monitoring.

9.
Polymers (Basel) ; 13(13)2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34209021

RESUMO

The aim of this paper was to provide insight into the impact of matrix and surfactants on the rheology, morphology, and dielectric and piezoelectric properties of screen-printed BaTiO3/PVDF composites. Two matrices were compared (PVDF-HFP and PVDF-TrFE), and lead-free BaTiO3 microparticles were added in volume fractions of 30% and 60%. Here, we demonstrated that the presence of surfactants, helping to prevent phase separation, was crucial for achieving a decent screen-printing process. Fourier-transform infrared (FTIR) spectroscopy together with scanning electron microscopy (SEM) showed that the two "fluoro-benzoic acid" surfactants established stable bonds with BaTiO3 and improved the dispersion homogeneity, while the "fluoro-silane" proved to be ineffective due to it evaporating during the functionalization process. PVDF-TrFE composites featured a more homogeneous composite layer, with fewer flaws and lower roughness, as compared with PVDF-HFP composites, and their inks were characterized by a higher viscosity. The samples were polarized in either AC or DC mode, at two different temperatures (25 °C and 80 °C). The 30% BaTiO3 PVDF-TrFE composites with two fluorinated surfactants featured a higher value of permittivity. The choice of the surfactant did not affect the permittivity of the PVDF-HFP composites. Concerning the d33 piezoelectric coefficient, experimental results pointed out that PVDF-TrFE matrices made it possible to obtain higher values, and that the best results were achieved in the absence of surfactants (or by employing the fluoro-silane). For instance, in the composites with 60% BaTiO3 and polarized at 80 °C, a d33 of 7-8 pC/N was measured, which is higher than the values reported in the literature.

10.
Clin Implant Dent Relat Res ; 23(4): 562-567, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34219356

RESUMO

BACKGROUND: Although full-arch immediately loaded rehabilitations are widely used nowadays, little information is available on which implant/abutment connection is the most suitable in this type of treatment. PURPOSE: The aim of the present multicentric split-mouth clinical trial was to compare the clinical outcomes of two different implant-abutment connections applied in full-arch immediate loading rehabilitations: external hexagon connection (EHC) versus internal hexagon connection (IHC). MATERIALS AND METHODS: Twenty patients were rehabilitated with immediately loaded fixed full-arch rehabilitations. All the implants presented the same macro- and micro-topography but different implant/abutment connection. IHC were used in one randomly selected side of the jaw and EHC in the other side. Outcome measures were implant survival rate, peri-implant marginal bone loss (MBL), plaque index (PI), probing depth (PD), and bleeding on probing (BoP) evaluated at 3, 6, 12, and 36-month post-loading. Any technical and biological complication was recorded. Kaplan-Meier procedure and linear mixed model were used to perform statistical analysis. RESULTS: Forty-three EHC and 40 IHC implants were inserted. No patients dropped out and two implants failed in the first 6 months. The CSR was 97.7% for EHC and 97.5% for IHC implants. No statistically significant differences were found among the two groups for any of the parameters at any time point. At the 36-month follow-up visit a slight difference was found in MBL with a mean value of 1.7 mm in the EHC and of 1.9 mm in the IHC group (p = 0.355). No biologic complications were identified. Seven loosed abutment screws were identified in the entire follow-up period, two in the EHC, and five in the IHC group without a statistically significant difference (p = 0.394). CONCLUSIONS: After 36 months in function, both internal and external hexagon connections provided good clinical outcomes and were not associated with any significant difference.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Índice de Placa Dentária , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Boca , Resultado do Tratamento
11.
Polymers (Basel) ; 12(2)2020 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-32041111

RESUMO

This paper describes a new class of light transducer-based poly (vinylidene fluoride-trifluoroethylene-chlorotrifluoroethylene) (P(VDF-TrFE-CTFE)) terpolymer doped with 50% wt. phosphor particles that enables to efficiently transform light energy into an electrical signal. Broadband dielectric characterization together with experimental results on photo-electric conversion demonstrated high capacitance variation of the proposed composite under light exposure, confirming promising potential of our sensor device for application in retinal prostheses where the converted electrical signal can affect the biological activity of the neuron system. In addition to the benefit of being light-weight, having ultra-flexibility, and used in a simple process, the proposed photodetector composite leads to fast response and high sensibility in terms of photoelectrical coupling where significant increases in capacitance change of 78% and 25% have been recorded under blue and green light sources, respectively. These results demonstrated high-performance material design where phosphor filler contributes to promote charge-discharge efficiency as well as reduced dielectric loss in P(VDF-TrFE-CTFE), which facilitate the composite for flexible light transducer applications, especially in the medical environment.

SELEÇÃO DE REFERÊNCIAS