Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Rev Med Pharmacol Sci ; 21(16): 3563-3575, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28925488

RESUMO

OBJECTIVE: The aim of our report was to review the literature concerning the toxicity of radiation therapy in patients treated for high-risk prostate cancer, and to evaluate the differences in toxicity between conventional fractionation and hypofractionated treatments, in view of different techniques used in high-risk prostate cancer patients. MATERIALS AND METHODS: PubMed database has been explored for studies concerning acute and late urinary/gastrointestinal toxicity in high-risk prostate cancer patients treated with radiotherapy. Prospective studies, concerning potential relationship between acute/late genitourinary (GU)/gastrointestinal (GI) toxicity and prostate radiotherapy in patients with high-risk prostate cancer, were included in the final analysis. Data collected from single arm, phase II non-randomized and randomized studies have been evaluated to perform odds ratio for toxicity risk. Furthermore, meta-analysis randomized prospective trials were considered suitable because they had recruited high-risk prostate cancer patients who didn't undergo surgery, with available data on ≥ G2 toxicity frequency. RESULTS: The initial search provided 606 results, but only 35 manuscripts met all eligibility requirements and were included in this report. In order to perform odds ratio we observed a decrease in late gastrointestinal toxicity for patients treated with hypofractionated schemes compared to CV treated ones. Among patients who underwent conventional treatment, SIB seemed to decrease acute genitourinary side effects; SIB-Hypo treated patients suffered less toxicity than patients treated with hypofractionated- sequential boost schemes. Hypo-SIB schemes would seem less toxic in terms of acute gastrointestinal and late genitourinary side effects than CV-SIB. Therefore, our focus shifted to 6 clinical trials evaluating genitourinary and gastrointestinal toxicity in patients who had been randomized to receive conventional fractionation or hypofractionated treatment, in both cases with IMRT technology. Our meta-analysis of these randomized trials involving patients with high-risk prostate cancer showed a statistically significant increase in late genitourinary toxicity for hypo-treated patients; no difference was observed in acute genitourinary/gastrointestinal toxicity, and in late gastrointestinal toxicity. CONCLUSIONS: Our analysis doesn't want to establish a definitive truth; very few trials assessed only high risk-class patients. Our purpose is to stimulate further randomized prospective trials focusing both on the effectiveness and toxicity profile (toxicity/effectiveness ratio), taking into account the use of different technologies and doses.


Assuntos
Neoplasias da Próstata/radioterapia , Lesões por Radiação/etiologia , Fracionamento da Dose de Radiação , Gastroenteropatias/etiologia , Humanos , Masculino , Radioterapia de Intensidade Modulada , Ensaios Clínicos Controlados Aleatórios como Assunto , Reto/patologia
2.
Oper Dent ; 40(4): 440-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25602350

RESUMO

OBJECTIVE: The aim of the study was to compare in Class V composite restorations marginal leakage measurements obtained with microcomputed tomography (micro-CT) and scanning electron microscopy (SEM) observations. METHODS: Class V cavities were prepared on 10 human molars and restored using Optibond FL (Kerr, Orange, CA, USA) and Premise Flowable (Kerr). Sealing ability was evaluated by assessing silver-nitrate penetration depth along enamel and dentin margins. Leakage was quantified using a scoring system. Micro-CT analysis provided 502 cross-sectional images for each tooth. Microleakage evaluation was performed first on three cross-sections corresponding to the sections examined by SEM, then on all 502 of the obtained micro-CT images. SEM observations were performed first at 20× magnification, then, if showing a zero score, at 80× magnification. Enamel and dentin microleakage scores assigned to corresponding sections through micro-CT and SEM (20×) were compared (Wilcoxon signed-rank test, α=0.05). RESULTS: No statistically significant difference in leakage scores emerged between micro-CT and 20×-magnification SEM. Eight tooth sections that were given a zero score under SEM at 20× magnification showed to be infiltrated at the higher magnification (80×). For five teeth a higher score was assigned following scanning of 502 cross-sections than based on the observation of three sections. CONCLUSIONS: Micro-CT presents as a valid, nondestructive in vitro method to quantitatively evaluate marginal leakage of adhesive restorations.


Assuntos
Resinas Compostas , Infiltração Dentária/diagnóstico por imagem , Restauração Dentária Permanente , Microscopia Eletrônica de Varredura , Microtomografia por Raio-X , Cárie Dentária/terapia , Preparo da Cavidade Dentária , Esmalte Dentário , Adaptação Marginal Dentária , Dentina , Humanos , Dente Molar/anatomia & histologia , Dente Molar/diagnóstico por imagem , Cimentos de Resina
3.
Int Endod J ; 45(12): 1148-55, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22757632

RESUMO

AIM: To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. METHODOLOGY: A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. RESULT: Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). CONCLUSIONS: Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments.


Assuntos
Materiais Revestidos Biocompatíveis , Ligas Dentárias/química , Níquel/química , Preparo de Canal Radicular/instrumentação , Esterilização/métodos , Titânio/química , Análise do Estresse Dentário , Teste de Materiais , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Espectrometria por Raios X , Vapor , Propriedades de Superfície
4.
Int Endod J ; 44(3): 203-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20880135

RESUMO

AIM: To use atomic force microscopy (AFM) to evaluate the effects of sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA) on the surface characteristics of ProTaper rotary nickel-titanium instruments. METHODOLOGY: A total of twenty ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) instruments (S1, S2, F1, F2) were divided into five groups: no immersion, immersion in 5.25% NaOCl for 5 or 10min and immersion in 17% EDTA for 5 or 10min. Twenty surface areas along 3-mm sections at the tip of the files (perfect squares of 1x1µm) were analysed by AFM operating in contact mode under ambient conditions. Three-dimensional images (400x400 lines) were processed using Gwyddion software, and the roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova and paired samples t-test. RESULTS: Three-dimensional AFM images of the surface of ProTaper instruments, including new and those immersed in NaOCl and EDTA solutions, revealed topographic irregularities at the nanometric scale. RMS and Ra values of instruments treated with NaOCl and EDTA solutions were statistically higher than that of the new ones (P<0.05). CONCLUSIONS: Atomic force microscopy three-dimensional images and roughness values indicated that short-term contact between NaOCl and EDTA endodontic irrigants and ProTaper instruments caused alterations in the surface of instruments.


Assuntos
Instrumentos Odontológicos , Ácido Edético/química , Níquel/química , Irrigantes do Canal Radicular/química , Hipoclorito de Sódio/química , Titânio/química , Análise de Variância , Ligas Dentárias/química , Microscopia de Força Atômica , Preparo de Canal Radicular/instrumentação , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA