Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 17: 1057-1066, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37056792

RESUMO

Purpose: To provide extended safety and effectiveness follow-up for eyes treated with circumferential canaloplasty and trabeculotomy (CP+TR) that were included in the 12-month ROMEO study. Setting: Seven multi-subspecialty ophthalmology practices located in 6 states (Arkansas, California, Kansas, Louisiana, Missouri, and New York). Design: Retrospective, multicenter, IRB approved. Subjects: Eligible eyes had mild-moderate glaucoma and were treated with CP+TR with cataract surgery or as a standalone intervention. Methods: Main outcome measures were mean IOP, mean number of ocular hypotensive medications, mean change in number of medications, proportion of patients with a ≥20% reduction in IOP or with IOP ≤18 mmHg, and proportion of patients medication free. Safety outcomes were adverse events and secondary surgical interventions (SSI). Results: Eight surgeons at 7 centers contributed 72 patients stratified by pre-operative intraocular pressure (IOP); >18 mmHg (Grp1), ≤18 mmHg (Grp2). Mean follow-up of 2.1 years (min 1.4, max 3.5). 2-year IOP (SD) was 15.6 mmHg (-6.1 mmHg, -28% from baseline) on 1.4 medications (-0.9, -39%) for Grp1 with cataract surgery; 14.7 mmHg (-7.4 mmHg, -33% from baseline) on 1.6 medications (-0.7, -15%) for Grp1 standalone, 13.7 mmHg (-0.6 mmHg, -4.2%) on 1.2 medications (-0.8, -35%) for Grp2 with cataract surgery, 13.3 mmHg (-2.3 mmHg, -14.7%) on 1.2 medications (-1.0, -46%) for Grp2 standalone. The proportion of patients at 2 years with either a ≥20% IOP reduction or IOP between 6 and 18 mmHg and no increase in medication or SSI was 75% (54 of 72, 95% CI 69.9%, 80.1%). One-third of patients (24 of 72) were medication free whereas 9 of 72 were pre-surgical. No device-related adverse events during extended follow-up; 6 eyes (8.3%) required additional surgical or laser intervention for IOP control after 12 months. Conclusion: CP+TR provides effective IOP control that is sustained for 2 years or more.

2.
Clin Ophthalmol ; 16: 3043-3052, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128338

RESUMO

Purpose: Twelve-month safety and effectiveness results for canaloplasty combined with trabeculotomy using the OMNI surgical system in pseudophakic eyes or combined with cataract surgery in mild-to-moderate open-angle glaucoma (OAG). Setting: Sixteen centers in 11 US states (AL, AR, CA, CT, KS, LA, MO, NY, SD, TN, TX). Design: Retrospective, case series, open-label. Methods: A total of 136 eligible patients from 20 surgeons: mild-to-moderate OAG (visual field mean deviation (MD) not worse than -12 dB), 12-month follow-up, preoperative medicated IOP >18 mmHg and ≤36 mmHg on ≤5 medications. One eye per patient enrolled. Endpoints included proportion with ≥20% reduction in IOP or IOP between 6 and 18 mmHg (inclusive) and on the same or fewer medications without secondary surgical intervention (SSI) (primary success), mean IOP, change in IOP, ocular hypotensive medication use, and proportion of patients with a 20% or greater reduction in IOP at 12 months. Safety: adverse events (AE) and best corrected visual acuity (BCVA). Results: Primary success was met by 71%. Mean IOP was reduced (22.3-15.9 mmHg, p < 0.0001). Medications went from 1.9 ± 1.3 to 1.3 ± 1.2 (p < 0.001). AE were mild and as expected for angle surgery. The most frequent AE were BCVA loss (6%), mild inflammation (4%), IOP elevation (3%), and clinically significant hyphema (3%). There were 4 (3%) SSI. Conclusion: The OMNI system provides effective IOP reduction, sustained IOP control, and meaningful medication reduction for up to 12 months postoperative. The present study confirms and extends the results from ROMEO.

4.
Ophthalmol Glaucoma ; 4(2): 173-181, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33045423

RESUMO

PURPOSE: Provide outcomes up to 12 months postsurgically for sequential canaloplasty and trabeculotomy with the OMNI surgical system (Sight Sciences, Inc) in pseudophakic patients with mild to moderate open-angle glaucoma. DESIGN: Retrospective, multicenter, single-arm study conducted at 10 multi-subspecialty ophthalmology practices and surgery centers located in 7 states (Arkansas, California, Kansas, Louisiana, Missouri, New York, and Texas). PARTICIPANTS: Eligible patients were pseudophakic, with mild/moderate open-angle glaucoma, 12-month follow-up, and medicated intraocular pressure (IOP) ≤36 mmHg on ≤4 medications preoperatively. One eye per patient was enrolled. METHODS: Institutional Review Board approved. All available cases meeting eligibility criteria were enrolled. Analysis of secondary end points was stratified by baseline (BL) IOP (>18 mmHg in group 1 and ≤18 mmHg in group 2) recognizing that treatment goals differed depending on BL IOP. MAIN OUTCOME MEASURES: Primary success was defined as the proportion of patients with ≥20% reduction in IOP from BL or IOP between 6 and 18 mmHg (inclusive) and on the same or fewer medications without secondary surgical intervention (SSI). Other effectiveness end points included mean IOP and number of medications at 12 months. Safety end points were best-corrected visual acuity (BCVA), adverse events (AEs), and SSIs. RESULTS: Forty-eight patients were enrolled, 24 in each group. Primary success was met by 73%. Mean IOP was reduced in group 1 (21.8 to 15.6 mmHg, P < 0.0001) and remained controlled in group 2 (15.4 to 13.9 mmHg, P = 0.24). Medications went from 1.7 ± 1.3 to 1.2 ± 1.3 (P = 0.024) in group 1 and from 2.0 ± 1.3 to 1.3 ± 1.3 (P = 0.003) in group 2. Adverse events were typical for the patient population undergoing angle surgery. Those reasonably related to the procedure were mild inflammation (13%), IOP spikes (6%), hyphema, corneal edema, and BCVA loss (all 4%). Five patients (10%) required an SSI. CONCLUSIONS: The sequential combination of canaloplasty followed by trabeculotomy performed as stand-alone procedures using the OMNI system in pseudophakic patients with open-angle glaucoma provides effective IOP reduction or sustained IOP control and meaningful medication reduction for up to 12 months postoperatively.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Glaucoma de Ângulo Aberto/complicações , Humanos , Pressão Intraocular , Estudos Retrospectivos , Tonometria Ocular
5.
Middle East Afr J Ophthalmol ; 20(2): 126-30, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23741131

RESUMO

Glaucoma represents a leading cause of preventable vision loss in Sub-Saharan Africa. Recent studies evaluating outcomes of glaucoma drainage implant (GDI) surgery suggest an important role for this approach in the African patient population. The Tube Versus Trabeculectomy study demonstrated a higher success rate with non-valved GDI surgery compared to trabeculectomy with mitomycin C after five years. The Ahmed Baerveldt Comparison study showed no difference in surgical failure rates between the Ahmed Glaucoma Valve and the Baerveldt Glaucoma Implant (BGI) but better intraocular pressure outcomes with the BGI at one year. The Ahmed Versus Baerveldt study demonstrated a lower failure rate for the BGI, but also a requirement for more post-operative interventions. Further study of GDI surgery in the Sub-Saharan Africa is necessary to determine its optimal place in the treatment paradigm for glaucoma patients in the region.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , África Subsaariana , Humanos , Pressão Intraocular/fisiologia , Mitomicina , Tonometria Ocular , Trabeculectomia , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA