1.
Ultrasound Med Biol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38714465

RESUMO

OBJECTIVE: Ultrasound speckle tracking enables in vivo measurement of soft tissue deformation or strain, providing a non-invasive diagnostic tool to quantify tissue health. However, adoption into new fields is challenging since algorithms need to be tuned with gold-standard reference data that are expensive or impractical to acquire. Here, we present a novel optimization approach that only requires repeated measurements, which can be acquired for new applications where reference data might not be readily available or difficult to get hold of. METHODS: Soft tissue motion was captured using ultrasound for the medial collateral ligament (MCL) of three quasi-statically loaded porcine stifle joints, and medial ligamentous structures of a dynamically loaded human cadaveric knee joint. Using a training subset, custom speckle tracking algorithms were created for the porcine and human ligaments using surrogate optimization, which aimed to maximize repeatability by minimizing the normalized standard deviation of calculated strain maps for repeat measurements. An unseen test subset was then used to validate the tuned algorithms by comparing the ultrasound strains to digital image correlation (DIC) surface strains (porcine specimens) and length change values of the optically tracked ligament attachments (human specimens). RESULTS: After 1500 iterations, the optimization routine based on the porcine and human training data converged to similar values of normalized standard deviations of repeat strain maps (porcine: 0.19, human: 0.26). Ultrasound strains calculated for the independent test sets using the tuned algorithms closely matched the DIC measurements for the porcine quasi-static measurements (R > 0.99, RMSE < 0.59%) and the length change between the tracked ligament attachments for the dynamic human dataset (RMSE < 6.28%). Furthermore, strains in the medial ligamentous structures of the human specimen during flexion showed a strong correlation with anterior/posterior position on the ligaments (R > 0.91). CONCLUSION: Adjusting ultrasound speckle tracking algorithms using an optimization routine based on repeatability led to robust and reliable results with low RMSE for the medial ligamentous structures of the knee. This tool may be equally beneficial in other soft-tissue displacement or strain measurement applications and can assist in the development of novel ultrasonic diagnostic tools to assess soft tissue biomechanics.

2.
Proc Inst Mech Eng H ; 238(5): 471-482, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38644528

RESUMO

The use of uncemented stems in hip arthroplasty has been increasing, even in osteoporotic patients. The major concerns of uncemented hip-stems, however, are peri-prosthetic fracture, thigh pain, and proximal femoral stress-/strain-shielding. In this study, a novel design of uncemented hip-stem is proposed that will reduce such concerns, improve osseointegration, and benefit both osteoporotic and arthritic patients. The stem has a central titanium alloy core surrounded by a set of radial buttresses that are partly porous titanium, as is the stem tip. The aim of the study was to investigate the mechanical behaviour of the proposed partly-porous design, examining load transfer in the short-term, and comparing its strain-shielding behaviour with a solid metal implant. The long-term effect of implant-induced bone remodelling was also simulated. Computed tomography based three-dimensional finite element models of an intact proximal femur, and the same femur implanted with the proposed design, were developed. Peak hip contact and major muscle forces corresponding to level-walking and stair climbing were applied. The proposed partly-porous design had approximately 50% lower strain-shielding than the solid-metal counterpart. Results of bone remodelling simulation indicated that only 16% of the total bone volume is subjected to reduction of bone density. Strain concentrations were observed in the bone around the stem-tip for both solid and porous implants; however, it was less prominent for the porous design. Lower strain-shielding and reduced bone resorption are advantageous for long-term fixation, and the reduced strain concentration around the stem-tip indicates a lower risk of peri-prosthetic fracture.


Assuntos
Análise de Elementos Finitos , Prótese de Quadril , Desenho de Prótese , Estresse Mecânico , Humanos , Artroplastia de Quadril/instrumentação , Porosidade , Fêmur/cirurgia , Teste de Materiais
3.
Front Bioeng Biotechnol ; 12: 1274496, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38524193

RESUMO

Introduction: Arthroplasty-associated bone loss remains a clinical problem: stiff metallic implants disrupt load transfer to bone and, hence, its remodeling stimulus. The aim of this research was to analyze how load transfer to bone is affected by different forms of knee arthroplasty: isolated partial knee arthroplasty (PKA), compartmental arthroplasty [combined partial knee arthroplasty (CPKA), two or more PKAs in the same knee], and total knee arthroplasty (TKA). Methods: An experimentally validated subject-specific finite element model was analyzed native and with medial unicondylar, lateral unicondylar, patellofemoral, bi-unicondylar, medial bicompartmental, lateral bicompartmental, tricompartmental, and total knee arthroplasty. Three load cases were simulated for each: gait, stair ascent, and sit-to-stand. Strain shielding and overstraining were calculated from the differences between the native and implanted states. Results: For gait, the TKA femoral component led to mean strain shielding (30%) more than three times higher than that of PKA (4%-7%) and CPKA (5%-8%). Overstraining was predicted in the proximal tibia (TKA 21%; PKA/CPKA 0%-6%). The variance in the distribution for TKA was an order of magnitude greater than for PKA/CPKA, indicating less physiological load transfer. Only the TKA-implanted femur was sensitive to the load case: for stair ascent and gait, almost the entire distal femur was strain-shielded, whereas during sit-to-stand, the posterior femoral condyles were overstrained. Discussion: TKA requires more bone resection than PKA and CPKA. These finite element analyses suggest that a longer-term benefit for bone is probable as partial and multi-compartmental knee procedures lead to more natural load transfer compared to TKA. High-flexion activity following TKA may be protective of posterior condyle bone resorption, which may help explain why bone loss affects some patients more than others. The male and female bone models used for this research are provided open access to facilitate future research elsewhere.

4.
Am J Sports Med ; 52(6): 1505-1513, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38551132

RESUMO

BACKGROUND: There is little evidence of the biomechanical performance of medial collateral ligament (MCL) reconstructions for restoring stability to the MCL-deficient knee regarding valgus, external rotation (ER), and anteromedial rotatory instability (AMRI). HYPOTHESIS: A short isometric reconstruction will better restore stability than a longer superficial MCL (sMCL) reconstruction, and an additional deep MCL (dMCL) graft will better control ER and AMRI than single-strand reconstructions. STUDY DESIGN: Controlled laboratory study. METHODS: Nine cadaveric human knees were tested in a kinematics rig that allowed tibial loading while the knee was flexed-extended 0° to 100°. Optical markers were placed on the femur and tibia and displacements were measured using a stereo camera system. The knee was tested intact, and then after MCL (sMCL + dMCL) transection, and loaded in anterior tibial translation (ATT), ER, varus-valgus, and combined ATT + ER (AMRI loading). Five different isometric MCL reconstructions were tested: isolated long sMCL, a short construct, each with and without dMCL addition, and isolated dMCL reconstruction, using an 8 mm-wide synthetic graft. RESULTS: MCL deficiency caused an increase in ER of 4° at 0° of flexion (P = .271) up to 14° at 100° of flexion (P = .002), and valgus laxity increased by 5° to 8° between 0° and 100° of flexion (P < .024 at 0°-90°). ATT did not increase significantly in isolated MCL deficiency (P > .999). All 5 reconstructions restored native stability across the arc of flexion apart from the isolated long sMCL, which demonstrated residual ER instability (P≤ .047 vs other reconstructions). CONCLUSION: All tested techniques apart from the isolated long sMCL graft are satisfactory in the context of restoring the valgus, ER, and AMRI stability to the MCL-deficient knee in a cadaveric model. CLINICAL RELEVANCE: Contemporary MCL reconstruction techniques fail to control ER and therefore AMRI as they use a long sMCL graft and do not address the dMCL. This study compares 5 MCL reconstruction techniques. Both long and short isometric constructs other than the long sMCL achieved native stability in valgus and ER/AMRI. Double-strand reconstructions (sMCL + dMCL) tended to provide more stability. This study shows which reconstructions demonstrate the best biomechanical performance, informs surgical reconstruction techniques for AMRI, and questions the efficacy of current popular techniques.


Assuntos
Cadáver , Instabilidade Articular , Ligamento Colateral Médio do Joelho , Humanos , Fenômenos Biomecânicos , Ligamento Colateral Médio do Joelho/cirurgia , Instabilidade Articular/cirurgia , Instabilidade Articular/fisiopatologia , Masculino , Idoso , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Feminino , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Rotação
5.
Am J Sports Med ; 52(4): 968-976, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38343203

RESUMO

BACKGROUND: Historical MCL (medial collateral ligament) reconstruction (MCLR) techniques have focused on the superficial MCL (sMCL) to restore valgus stability while frequently ignoring the importance of the deep MCL (dMCL) in controlling tibial external rotation. The recent recognition of the medial ligament complex importance has multiple studies revisiting medial anatomy and questioning contemporary MCLR techniques. PURPOSE: To assess whether (1) an isolated sMCL reconstruction (sMCLR), (2) an isolated dMCL reconstruction (dMCLR), or (3) a novel single-strand short isometric construct (SIC) would restore translational and rotational stability to a knee with a dMCL and sMCL injury. STUDY DESIGN: Controlled laboratory study. METHODS: Biomechanical testing was performed on 14 fresh-frozen cadaveric knee specimens using a custom multiaxial knee activity simulator. The specimens were divided into 2 groups. The first group was tested in 4 states: intact, after sectioning the sMCL and dMCL, isolated sMCLR, and isolated dMCLR. The second group was tested in 3 states: intact, after sectioning the sMCL and dMCL, and after single-strand SIC reconstruction (SICR). In each state, 4 loading conditions were applied at 0°, 20°, 40°, 60°, and 90° of knee flexion: 8-N·m valgus torque, 5-N·m external rotation torque, 90-N anterior drawer, and combined 90-N anterior drawer plus 5-N·m tibial external rotation torque. Anterior translation, valgus rotation, and external rotation of the knee were measured for each state and loading condition using an optical motion capture system. RESULTS: sMCL and dMCL transection resulted in increased laxity for all loading conditions at all flexion angles. Isolated dMCLR restored external rotation stability to intact levels throughout all degrees of flexion, yet valgus stability was restored only at 0° of flexion. Isolated sMCLR restored valgus and external rotation stability at 0°, 20°, and 40° of flexion but not at 60° or 90° of flexion. Single-strand SICR restored valgus and external rotation stability at all flexion angles. In the combined anterior drawer plus external rotation test, isolated dMCL and single-strand SICR restored stability to the intact level at all flexion angles, while the isolated sMCL restored stability at 20° and 40° of flexion but not at 60° or 90° of flexion. CONCLUSION: In the cadaveric model, single-strand SICR restored valgus and rotational stability throughout the range of motion. dMCLR restored rotational stability to the knee throughout the range of motion but did not restore valgus stability. Isolated sMCLR restored external rotation and valgus stability in early flexion. CLINICAL RELEVANCE: In patients with anteromedial rotatory instability in the knee, neither an sMCLR nor a dMCLR is sufficient to restore stability.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamentos Colaterais , Instabilidade Articular , Adulto , Humanos , Fenômenos Biomecânicos , Instabilidade Articular/cirurgia , Cadáver , Articulação do Joelho/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Amplitude de Movimento Articular , Ligamentos Colaterais/cirurgia
6.
Sports Med Open ; 9(1): 60, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37466866

RESUMO

Achilles' tendon (AT) injuries such as ruptures and tendinopathies have experienced a dramatic rise in the mid- to older-aged population. Given that the AT plays a key role at all stages of locomotion, unsuccessful rehabilitation after injury often leads to long-term, deleterious health consequences. Understanding healthy in vivo strains as well as the complex muscle-tendon unit interactions will improve access to the underlying aetiology of injuries and how their functionality can be effectively restored post-injury. The goals of this survey of the literature with a systematic search were to provide a benchmark of healthy AT strains measured in vivo during functional activities and identify the sources of variability observed in the results. Two databases were searched, and all articles that provided measured in vivo peak strains or the change in strain with respect to time were included. In total, 107 articles that reported subjects over the age of 18 years with no prior AT injury and measured while performing functional activities such as voluntary contractions, walking, running, jumping, or jump landing were included in this review. In general, unclear anatomical definitions of the sub-tendon and aponeurosis structures have led to considerable confusion in the literature. MRI, ultrasound, and motion capture were the predominant approaches, sometimes coupled with modelling. The measured peak strains increased from 4% to over 10% from contractions, to walking, running, and jumping, in that order. Importantly, measured AT strains were heavily dependent on measurement location, measurement method, measurement protocol, individual AT geometry, and mechanical properties, as well as instantaneous kinematics and kinetics of the studied activity. Through a comprehensive review of approaches and results, this survey of the literature therefore converges to a united terminology of the structures and their common underlying characteristics and presents the state-of-knowledge on their functional strain patterns.

7.
Arthrosc Tech ; 12(2): e167-e171, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36879857

RESUMO

Recently there has been increased focus on the medial collateral ligament (MCL) and the role the medial ligament complex plays in preventing valgus and external rotation, especially in the setting of a combined ligament injury. Multiple surgical techniques purport to reproduce "normal anatomy"; however, only one technique addresses the deep MCL fibers and the prevention of external rotation. Thus we describe the "short isometric construct" MCL reconstruction which is stiffer than the anatomic reconstructions. The "short isometric construct" technique resists valgus throughout range of motion whereas its obliquity resists tibial external rotation, helping to reduce the risk of anterior cruciate ligament graft re-rupture.

8.
Am J Sports Med ; 51(5): 1136-1145, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36917838

RESUMO

BACKGROUND: Injuries to the anterior cruciate ligament (ACL), Kaplan fibers (KFs), anterolateral capsule/ligament (C/ALL), and lateral meniscus posterior root (LMPR) have been separately linked to anterolateral instability. PURPOSE: To investigate the contributions of the ACL, KFs, C/ALL, and LMPR to knee stability and to measure instabilities resulting from their injury. STUDY DESIGN: Controlled laboratory study. METHODS: Ten fresh-frozen human knees were tested robotically to determine restraints of knee laxity at 0° to 90° of flexion. An 88-N anterior-posterior force (anterior and posterior tibial translation), 5-N·m internal-external rotation, and 8-N·m valgus-varus torque were imposed and intact kinematics recorded. The kinematics were replayed after sequentially cutting the structures (order varied) to calculate their contributions to stability. Another 10 knees were tested in a kinematics rig with optical tracking to measure instabilities after sequentially cutting the structures across 0° to 100° of flexion. One- and 2-way repeated-measures analyses of variance with Bonferroni correction were used to find significance (P < .05) for the robotic and kinematics tests. RESULTS: The ACL was the primary restraint for anterior tibial translation; other structures were insignificant (<10% contribution). The KFs and C/ALL resisted internal rotation, reaching 44% ± 23% (mean ± SD; P < .01) and 14% ± 13% (P < .05) at 90°. The LMPR resisted valgus but not internal rotation. Anterior tibial translation increased after ACL transection (P < .001) and after cutting the lateral structures from 70° to 100° (P < .05). Pivot-shift loading increased anterolateral rotational instability after ACL transection from 0° to 40° (P < .05) and further after cutting the lateral structures from 0° to 100° (P < .01). CONCLUSION: The anterolateral complex acts as a functional unit to provide rotatory stability. The ACL is the primary stabilizer for anterior tibial translation. The KFs are the most important internal rotation restraint >30° of flexion. Combined KFs + C/ALL injury substantially increased anterolateral rotational instability while isolated injury of either did not. LMPR deficiency did not cause significant instability with the ACL intact. CLINICAL RELEVANCE: This study is a comprehensive biomechanical sectioning investigation of the knee stability contributions of the ACL, anterolateral complex, and LMPR and the instability after their transection. The ACL is significant in controlling internal rotation only in extension. In flexion, the KFs are dominant, synergistic with the C/ALL. LMPR tear has an insignificant effect with the ACL intact.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Instabilidade Articular , Humanos , Ligamento Cruzado Anterior/cirurgia , Meniscos Tibiais , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Instabilidade Articular/cirurgia , Fenômenos Biomecânicos , Cadáver
9.
Am J Sports Med ; 50(7): 1823-1831, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35511430

RESUMO

BACKGROUND: Although a medial collateral ligament (MCL) injury is associated with anteromedial rotatory instability (AMRI) and often with an anterior cruciate ligament (ACL) injury, there has been little work to develop anteromedial (AM) reconstruction to address this laxity. PURPOSE: To measure the ability of a novel "anatomic" AM reconstruction technique to restore native knee laxity for isolated AM insufficiency and combined AM plus posteromedial insufficiency. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 12 cadaveric knees were mounted in a kinematic testing rig that allowed the tibia to be loaded while the knee flexed-extended 0° to 100° with 88-N anteroposterior translation, 5-N·m internal rotation-external rotation (ER), 8-N·m valgus, and combined anterior translation plus ER to simulate AMRI. Joint motion was measured using optical trackers with the knee intact, after superficial MCL (sMCL) and deep MCL (dMCL) transection, and after AM reconstruction of the sMCL and dMCL with semitendinosus autografts. The posteromedial capsule (PMC)/posterior oblique ligament (POL) was then transected to induce a grade 3 medial injury, and kinematic measurements were repeated afterward and again after removing the grafts. Laxity changes were examined using repeated-measures analysis of variance and post-testing. RESULTS: sMCL and dMCL deficiency increased valgus, ER, and AMRI laxities. These laxities did not differ from native values after AM reconstruction. Additional PMC/POL deficiency did not increase these laxities significantly but did increase internal rotation laxity near knee extension; this was not controlled by AM reconstruction. CONCLUSION: AM reconstruction eliminated AMRI after transection of the dMCL and sMCL, and also eliminated AMRI after additional PMC/POL transection. CLINICAL RELEVANCE: Many MCL injuries occur in combination with ACL injuries, causing AMRI. These injuries may rupture the AM capsule and dMCL. Unaddressed MCL deficiency leads to an increased ACL reconstruction failure rate. A dMCL construct oriented anterodistally across the medial joint line, along with an sMCL graft, can restore native knee ER laxity. PMC/POL lesions did not contribute to AMRI.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamentos Colaterais , Instabilidade Articular , Ligamento Colateral Médio do Joelho , Lesões do Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Ligamento Colateral Médio do Joelho/cirurgia , Amplitude de Movimento Articular , Torque
10.
Am J Sports Med ; 50(7): 1832-1842, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35503457

RESUMO

BACKGROUND: There are many descriptions of medial collateral ligament (MCL) reconstruction, but they may not reproduce the anatomic structures and there is little evidence of their biomechanical performance. PURPOSE: To investigate the ability of "anatomic" MCL reconstruction to restore native stability after grade III MCL plus posteromedial capsule/posterior oblique ligament injuries in vitro. STUDY DESIGN: Controlled laboratory study. METHODS: Twelve cadaveric knees were mounted in a kinematic testing rig to impose tibial displacing loads while the knee was flexed-extended: 88-N anteroposterior translation, 5-N·m internal-external rotation, 8-N·m valgus-varus, and combined anterior translation plus external rotation (anteromedial rotatory instability). Joint motion was measured via optical trackers with the knee intact; after superficial MCL (sMCL), deep MCL (dMCL), and posterior oblique ligament transection; and then after MCL double- and triple-strand reconstructions. Double strands reproduced the sMCL and posterior oblique ligament and triple-strands the sMCL, dMCL, and posterior oblique ligament. The sMCL was placed 5 mm posterior to the epicondyle in the double-strand technique and at the epicondyle in the triple-strand technique. Kinematic changes were examined by repeated measures 2-way analysis of variance with posttesting. RESULTS: Transection of the sMCL, dMCL, and posterior oblique ligament increased valgus rotation (5° mean) and external rotation (9° mean). The double-strand reconstruction controlled valgus in extension but allowed 5° excess valgus in flexion and did not restore external rotation (7° excess). The triple-strand reconstruction restored both external rotation and valgus throughout flexion. CONCLUSION: In a cadaveric model, a triple-strand reconstruction including a dMCL graft restored native external rotation, while a double-strand reconstruction without a dMCL graft did not. A reconstruction with the sMCL graft placed isometrically on the medial epicondyle restored valgus rotation across the arc of knee flexion, whereas a reconstruction with a more posteriorly placed sMCL graft slackened with knee flexion. CLINICAL RELEVANCE: An MCL injury may rupture the anteromedial capsule and dMCL, causing anteromedial rotatory instability. Persistent MCL instability increases the likelihood of ACL graft failure after combined injury. A reconstruction with an anteromedial dMCL graft restored native external rotation, which may help to unload/protect an ACL graft. It is important to locate the sMCL graft isometrically at the femoral epicondyle to restore valgus across flexion.


Assuntos
Instabilidade Articular , Ligamento Colateral Médio do Joelho , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Ligamento Colateral Médio do Joelho/cirurgia , Amplitude de Movimento Articular
11.
J Orthop Res ; 40(4): 799-807, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34191354

RESUMO

The mechanical advantage of the knee extensor mechanism depends heavily on the patellar tendon moment arm (PTMA). Understanding which factors contribute to its variation may help improve functional outcomes following arthroplasty. This study optimized PTMA measurement, allowing us to quantify the contribution of different variables. The PTMA was calculated about the instantaneous helical axis of tibiofemoral rotation from optical tracked kinematics. A fabricated knee model facilitated calculation optimization, comparing four data smoothing techniques (raw, Butterworth filtering, generalized cross-validated cubic spline-interpolation and combined filtering/interpolation). The PTMA was then measured for 24 fresh-frozen cadaveric knees, under physiologically based loading and extension rates. Combined filtering/interpolation enabled sub-mm PTMA calculation accuracy throughout the range of motion (root-mean-squared error 0.2 mm, max error 0.4 mm), whereas large errors were measured for raw, filtered-only and interpolated-only techniques at terminal flexion/extension. Before scaling, the mean PTMA was 46 mm; PTMA magnitude was consistently larger in males (mean differences: 5 to 10 mm, p < .05) and was strongly related to knee size: larger knees have a larger PTMA. However, while scaling eliminated sex differences in PTMA magnitude, the peak PTMA occurred closer to terminal extension in females (female 15°, male 29°, p = .01). Knee size accounted for two-thirds of the variation in PTMA magnitude, but not the flexion angle where peak PTMA occurred. This substantial variation in angle of peak PTMA has implications for the design of musculoskeletal models and morphotype-specific arthroplasty. The developed calculation framework is applicable both in vivo and vitro for accurate PTMA measurement.


Assuntos
Prótese do Joelho , Ligamento Patelar , Fenômenos Biomecânicos , Feminino , Humanos , Joelho , Articulação do Joelho/fisiologia , Masculino , Ligamento Patelar/fisiologia , Amplitude de Movimento Articular/fisiologia
12.
Foot Ankle Surg ; 28(2): 166-175, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33766498

RESUMO

AIMS: To compare the outcomes of early and standard rehabilitation protocols following tendon transfers in the foot and ankle using interference screw fixation (ISF). METHODS: A systematic review was performed for relevant articles (1998 to 2020) reporting foot tendon transfer using ISF in adults. The primary outcome was early tendon failure. Secondary outcomes included function and complications. RESULTS: In total, 21 studies met the inclusion criteria, totalling 494 patients. Seven studies reported early rehabilitation protocols. The rate of early tendon failure was zero for each protocol and studies consistently reported a significant improvement in function. No differences were found comparing different rehabilitation protocols for tendon transfer for Achilles tendon pathology and foot drop. CONCLUSION: Both early and standard rehabilitation protocols are associated with high patient satisfaction and low complication rates, but currently there is a lack of evidence to support early loaded activities or motion. LEVEL OF EVIDENCE: IV Systematic review including case series.


Assuntos
Tendão do Calcâneo , Transferência Tendinosa , Tendão do Calcâneo/cirurgia , Adulto , Tornozelo/cirurgia , Parafusos Ósseos , Humanos , Ruptura/cirurgia , Transferência Tendinosa/métodos , Resultado do Tratamento
13.
Bone Joint Res ; 10(11): 723-733, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34761697

RESUMO

AIMS: Bi-unicondylar arthroplasty (Bi-UKA) is a bone and anterior cruciate ligament (ACL)-preserving alternative to total knee arthroplasty (TKA) when the patellofemoral joint is preserved. The aim of this study is to investigate the clinical outcomes and biomechanics of Bi-UKA. METHODS: Bi-UKA subjects (n = 22) were measured on an instrumented treadmill, using standard gait metrics, at top walking speeds. Age-, sex-, and BMI-matched healthy (n = 24) and primary TKA (n = 22) subjects formed control groups. TKA subjects with preoperative patellofemoral or tricompartmental arthritis or ACL dysfunction were excluded. The Oxford Knee Score (OKS) and EuroQol five-dimension questionnaire (EQ-5D) were compared. Bi-UKA, then TKA, were performed on eight fresh frozen cadaveric knees, to investigate knee extensor efficiency under controlled laboratory conditions, using a repeated measures study design. RESULTS: Bi-UKA walked 20% faster than TKA (Bi-UKA mean top walking speed 6.7 km/h (SD 0.9),TKA 5.6 km/h (SD 0.7), p < 0.001), exhibiting nearer-normal vertical ground reaction forces in maximum weight acceptance and mid-stance, with longer step and stride lengths compared to TKA (p < 0.048). Bi-UKA subjects reported higher OKS (p = 0.004) and EQ-5D (p < 0.001). In vitro, Bi-UKA generated the same extensor moment as native knees at low flexion angles, while reduced extensor moment was measured following TKA (p < 0.003). Conversely, at higher flexion angles, the extensor moment of TKA was normal. Over the full range, the extensor mechanism was more efficient following Bi-UKA than TKA (p < 0.028). CONCLUSION: Bi-UKA had more normal gait characteristics and improved patient-reported outcomes, compared to matched TKA subjects. This can, in part, be explained by differences in extensor efficiency. Cite this article: Bone Joint Res 2021;10(11):723-733.

14.
J Biomech ; 129: 110669, 2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34564041

RESUMO

In vitro models of arthroplasty enable pre-clinical testing and inform clinical decision making. Repeated-measures comparisons maximise resource efficiency, but their validity without testing order randomisation is not known. This study aimed to identify if there were any large testing order effects for cadaveric models of knee and hip arthroplasty. First, the effect of testing order on total knee arthroplasty (TKA) biomechanics was assessed. Extension moments for TKAs (N = 3) implanted into the native knee (TKA-only) were compared to a dataset of TKAs (N = 24) tested after different combinations of partial knee arthroplasty (TKA-last). The effect of repeatedly testing the same knee five times over 36 h on patellofemoral and tibiofemoral kinematics was also quantified. Second, the effect of testing order on capsular ligament function after total hip arthroplasty (THA) was assessed. Randomisation was removed from a previously published dataset to create increasing and decreasing head size groups, which were compared with t-tests. All three TKA-only extension moments fell within the 95% CI of the TKA-last knees across the full range of knee flexion/extension. Repeated testing resulted in root-mean-squared kinematics errors within 1 mm, 1°, or < 5% of total range of motion. Following THA, smaller head-size resulted in greater laxity in both the increasing (p = 0.01) and decreasing (p < 0.001) groups. Testing order did not have large effects on either knee or hip arthroplasty biomechanics measured with in vitro cadaveric models.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese do Joelho , Fenômenos Biomecânicos , Humanos , Cinética , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular
15.
Knee Surg Sports Traumatol Arthrosc ; 29(12): 3902-3909, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34436636

RESUMO

PURPOSE: Persistent acromioclavicular joint (ACJ) instability following high grade injuries causes significant symptoms. The importance of horizontal plane stability is increasingly recognised. There is little evidence of the ability of current implant methods to restore native ACJ stability in the vertical and horizontal planes. The purpose of this work was to measure the ability of three implant reconstructions to restore native ACJ stability. METHODS: Three groups of nine fresh-frozen shoulders each were mounted into a robotic testing system. The scapula was stationary and the robot displaced the clavicle to measure native anterior, posterior, superior and inferior (A, P, S, I) stability at 50 N force. The ACJ capsule, conoid and trapezoid ligaments were transected and the ACJ was reconstructed using one of three commercially available systems. Two systems (tape loop + screw and tape loop + button) wrapped a tape around the clavicle and coracoid, the third system (sutures + buttons) passed directly through tunnels in the clavicle and coracoid. The stabilities were remeasured. The data for A, P, S, I stability and ranges of A-P and S-I stability were analyzed by ANOVA and repeated-measures Student t tests with Bonferroni correction, to contrast each reconstruction stability versus the native ACJ data for that set of nine specimens, and examined contrasts among the reconstructions. RESULTS: All three reconstructions restored the range of A-P stability to that of the native ACJ. However, the coracoid loop devices shifted the clavicle anteriorly. For S-I stability, only the sutures + buttons reconstruction did not differ significantly from native ligament restraint. CONCLUSIONS: Only the sutures + buttons reconstruction, that passed directly through tunnels in the clavicle and coracoid, restored all stability measures (A, P, S, I) to the native values, while the tape implants wrapped around the bones anteriorised the clavicle. These findings show differing abilities among reconstructions to restore native stability in horizontal and vertical planes. (300 words).


Assuntos
Articulação Acromioclavicular , Artroplastia de Substituição , Articulação Acromioclavicular/cirurgia , Clavícula/cirurgia , Humanos , Ligamentos Articulares/cirurgia , Âncoras de Sutura
16.
J Arthroplasty ; 36(11): 3765-3772.e4, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34330602

RESUMO

BACKGROUND: Little is known regarding anterior-posterior stability after anterior cruciate ligament-preserving partial (PKA) and combined partial knee arthroplasty (CPKA) compared to standard posterior cruciate-retaining total knee arthroplasty (TKA). METHODS: The anterior-posterior tibial translation of twenty-four cadaveric knees was measured, with optical tracking, while under 90N drawer with the knee flexed 0-90°. Knees were tested before and after PKA, CPKA (medial and lateral bicompartmental and bi-unicondylar), and then posterior cruciate-retaining TKA. The anterior-posterior tibial translations of the arthroplasty states, at each flexion angle, were compared to the native knee and each other with repeated measures analyses of variance and post-hoc t-tests. RESULTS: Unicompartmental and bicompartmental arthroplasty states had similar laxities to the native knee and to each other, with ≤1-mm differences throughout the flexion range (P ≥ .199). Bi-unicondylar arthroplasty resulted in 6- to 8-mm increase of anterior tibial translation at high flexion angles compared to the native knee (P ≤ .023 at 80-90°). Meanwhile, TKA exhibited increased laxity across all flexion angles, with increased anterior tibial translation of up to 18 ± 6 mm (P < .001) and increased posterior translation of up to 4 ± 2 mm (P < .001). CONCLUSIONS: In a cadaveric study, anterior-posterior tibial translation did not differ from native laxity after PKA and CPKA. Posterior cruciate ligament-preserving TKA demonstrated increased laxity, particularly in anterior tibial translation.


Assuntos
Artroplastia do Joelho , Ligamento Cruzado Posterior , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia
17.
Am J Sports Med ; 49(9): 2351-2360, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34125619

RESUMO

BACKGROUND: Little scientific evidence is available regarding the effect of knee joint line obliquity (JLO) before and after coronal realignment osteotomy. HYPOTHESES: Higher JLO would lead to abnormal relative position of the femur on the tibia, a shift of the joint contact areas, and elevated joint contact pressures. STUDY DESIGN: Descriptive laboratory study. METHODS: 10 fresh-frozen human cadaveric knees (age, 59 ± 5 years) were axially loaded to 1500 N in a materials testing machine with the joint line tilted 0°, 4°, 8°, and 12° varus ("downhill" medially) and valgus, at 0° and 20° of knee flexion. The mechanical compression axis was aligned to the center of the tibial plateau. Contact pressure and contact area were recorded by pressure sensors inserted between the tibia and femur below the menisci. Changes in relative femoral and tibial position in the coronal plane were obtained by an optical tracking system. RESULTS: Both medial and lateral JLO caused significant tibiofemoral subluxation and pressure distribution changes. Medial (varus) JLO caused the femur to subluxate medially down the coronal slope of the tibial plateau, and vice versa for lateral (valgus) downslopes (P < .01), giving a 6-mm range of subluxation. The areas of peak pressure moved 12 mm and 8 mm across the medial and lateral condyles, onto the downhill meniscus and the "uphill" tibial spine. Changes in JLO had only small effects on maximum contact pressures. CONCLUSION: A 4° change of JLO during load bearing caused significant mediolateral tibiofemoral subluxation. The femur slid down the slope of the tibial plateau to abut the tibial eminence and also to rest on the downhill meniscus. This caused large movements of the tibiofemoral contact pressures across each compartment. CLINICAL RELEVANCE: These results provide important information for understanding the consequences of creating coronal JLO and for clinical practice in terms of osteotomy planning regarding the effect on JLO. This information provides guidance regarding the choice of single- or double-level osteotomy. Excessive JLO alteration may cause abnormal tibiofemoral joint articulation and chondral or meniscal loading.


Assuntos
Menisco , Tíbia , Fenômenos Biomecânicos , Cadáver , Fêmur , Humanos , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade
18.
Am J Sports Med ; 49(9): 2387-2395, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34115540

RESUMO

BACKGROUND: Biomechanical studies on anterior cruciate ligament (ACL) injuries and reconstructions are based on ACL transection instead of realistic injury trauma. PURPOSE: To replicate an ACL injury in vitro and compare the laxity that occurs with that after an isolated ACL transection injury before and after ACL reconstruction. STUDY DESIGN: Controlled laboratory study. METHODS: Nine paired knees were ACL injured or ACL transected. For ACL injury, knees were mounted in a rig that imposed tibial anterior translation at 1000 mm/min to rupture the ACL at 22.5° of flexion, 5° of internal rotation, and 710 N of joint compressive force, replicating data published on clinical bone bruise locations. In contralateral knees, the ACL was transected arthroscopically at midsubstance. Both groups had ACL reconstruction with bone-patellar tendon-bone graft. Native, ACL-deficient, and reconstructed knee laxities were measured in a kinematics rig from 0° to 100° of flexion with optical tracking: anterior tibial translation (ATT), internal rotation (IR), anterolateral (ATT + IR), and pivot shift (IR + valgus). RESULTS: The ACL ruptured at 26 ± 5 mm of ATT and 1550 ± 620 N of force (mean ± SD) with an audible spring-back tibiofemoral impact with 5o of valgus. ACL injury and transection increased ATT (P < .001). ACL injury caused greater ATT than ACL transection by 1.4 mm (range, 0.4-2.2 mm; P = .033). IR increased significantly in ACL-injured knees between 0° and 30° of flexion and in ACL transection knees from 0° to 20° of flexion. ATT during the ATT + IR maneuver was increased by ACL injury between 0° and 80° and after ACL transection between 0° and 60°. Residual laxity persisted after ACL reconstruction from 0° to 40° after ACL injury and from 0° to 20° in the ACL transection knees. ACL deficiency increased ATT and IR in the pivot-shift test (P < .001). The ATT in the pivot-shift increased significantly at 0° to 20° after ACL transection and 0° to 50° after ACL injury, and this persisted across 0° to 20° and 0° to 40° after ACL reconstruction. CONCLUSION: This study developed an ACL injury model in vitro that replicated clinical ACL injury as evidenced by bone bruise patterns. ACL injury caused larger increases of laxity than ACL transection, likely because of damage to adjacent tissues; these differences often persisted after ACL reconstruction. CLINICAL RELEVANCE: This in vitro model created more realistic ACL injuries than surgical transection, facilitating future evaluation of ACL reconstruction techniques.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Instabilidade Articular , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Rotação
19.
Knee Surg Sports Traumatol Arthrosc ; 29(2): 659-667, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32322947

RESUMO

PURPOSE: Revision constrained-condylar total knee arthroplasty (CCK-TKA) is often used to provide additional mechanical constraint after failure of a primary TKA. However, it is unknown how much this translates to a reliance on soft-tissue support. The aim of this study was therefore to compare the laxity of a native knee to the CCK-TKA implanted state and quantify how medial soft-tissues stabilise the knee following CCK-TKA. METHODS: Ten intact cadaveric knees were tested in a robotic system at 0°, 30°, 60° and 90° flexion with ± 90  N anterior-posterior force, ± 8 Nm varus-valgus and ± 5 Nm internal-external torques. A fixed-bearing CCK-TKA was implanted and the laxity tests were repeated with the soft tissues intact and after sequential cutting. The deep and superficial medial collateral ligaments (dMCL, sMCL) and posteromedial capsule (PMC) were sequentially transected and the percentage contributions of each structure to restraining the applied loads were calculated. RESULTS: Implanting a CCK-TKA did not alter anterior-posterior laxity from that of the original native knee, but it significantly decreased internal-external and varus-valgus rotational laxity (p < 0.05). Post CCK-TKA, the sMCL restrained 34% of the tibial displacing load in anterior drawer, 16% in internal rotation, 17% in external rotation and 53% in valgus, across the flexion angles tested. The dMCL restrained 11% of the valgus rotation moment. CONCLUSIONS: With a fully-competent sMCL in-vitro, a fixed-bearing CCK-TKA knee provided more rotational constraint than the native knee. The robotic test data showed that both the soft-tissues and the semi-constrained implant restrained rotational knee laxity. Therefore, in clinical practice, a fixed-bearing CCK-TKA knee could be indicated for use in a knee with lax, less-competent medial soft tissues. LEVEL OF EVIDENCE: Controlled laboratory study.


Assuntos
Artroplastia do Joelho/métodos , Tecido Conjuntivo/fisiologia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Ligamentos Articulares/fisiopatologia , Ligamentos Articulares/cirurgia , Masculino , Amplitude de Movimento Articular , Reoperação , Rotação , Tíbia/fisiopatologia , Tíbia/cirurgia , Torque
20.
Bone Joint Res ; 10(1): 1-9, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33380175

RESUMO

AIMS: Unicompartmental knee arthroplasty (UKA) and bicompartmental knee arthroplasty (BCA) have been associated with improved functional outcomes compared to total knee arthroplasty (TKA) in suitable patients, although the reason is poorly understood. The aim of this study was to measure how the different arthroplasties affect knee extensor function. METHODS: Extensor function was measured for 16 cadaveric knees and then retested following the different arthroplasties. Eight knees underwent medial UKA then BCA, then posterior-cruciate retaining TKA, and eight underwent the lateral equivalents then TKA. Extensor efficiency was calculated for ranges of knee flexion associated with common activities of daily living. Data were analyzed with repeated measures analysis of variance (α = 0.05). RESULTS: Compared to native, there were no reductions in either extension moment or efficiency following UKA. Conversion to BCA resulted in a small decrease in extension moment between 70° and 90° flexion (p < 0.05), but when examined in the context of daily activity ranges of flexion, extensor efficiency was largely unaffected. Following TKA, large decreases in extension moment were measured at low knee flexion angles (p < 0.05), resulting in 12% to 43% reductions in extensor efficiency for the daily activity ranges. CONCLUSION: This cadaveric study found that TKA resulted in inferior extensor function compared to UKA and BCA. This may, in part, help explain the reported differences in function and satisfaction differences between partial and total knee arthroplasty. Cite this article: Bone Joint Res 2021;10(1):1-9.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA